• 제목/요약/키워드: loading rates

검색결과 579건 처리시간 0.031초

고변형율에서 황동 사출금형의 동적 거동 특성 (Dynamic Behavior Characteristics of Brass Mold at High Strain Rates)

  • 김선용;백승엽
    • Design & Manufacturing
    • /
    • 제2권2호
    • /
    • pp.1-5
    • /
    • 2008
  • Mechanical properties of the materials used for mold and industrial machinery under high strain rate loading conditions such as high impact loading are required to provide appropriate safety assessment to varying dynamically loaded mechanical structures. The Split Hopkinson Pressure Bar(SHPB) technique with a special experimental apparatus can be used to obtain the material behavior under high strain rate loading conditions. In this paper, the dynamic deformation behavior of a brass under high strain rate compressive loading conditions has been determined using the SHPB technique.

  • PDF

Cyclic behavior of interior beam-column connections in non-seismic RC frames at different loading rates

  • Dhakal, Rajesh P.;Pan, Tso-Chien
    • Structural Engineering and Mechanics
    • /
    • 제23권2호
    • /
    • pp.129-145
    • /
    • 2006
  • This paper provides an insight into the response of non-seismic reinforced concrete (RC) building frames to excitations of different frequencies through experimental investigation. The results of cyclic loading tests of six full-scale RC beam-column sub-assemblies are presented. The tested specimens did not have any transverse reinforcement inside the joint core, and they were subjected to quasi-static and dynamic loading with frequencies as high as 20 Hz. Some important differences between the cyclic responses of non-seismic and ductile RC frames are highlighted. The effect of excitation frequency on the behavior of non-seismic joints is also discussed. In the quasi-static tests, shear deformation of the joint panel accounted for more than 50% of the applied story drift. The test results also showed that higher-frequency excitations are less detrimental than quasi-static cyclic loads, and non-seismic frames can withstand a higher load and a larger deformation when they are applied faster.

Analysis of time to failure of orthodontic mini-implants after insertion or loading

  • Jeong, Jong-Wha;Kim, Jong-Wan;Lee, Nam-Ki;Kim, Young-Kyun;Lee, Jong-Ho;Kim, Tae-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제41권5호
    • /
    • pp.240-245
    • /
    • 2015
  • Objectives: This study was performed to evaluate patterns of failure time after insertion, failure rate according to loading time after insertion, and the patterns of failure after loading. Materials and Methods: A total of 331 mini-implants were classified into the non-failure group (NFG) and failure group (FG), which was divided into failed group before loading (FGB) and failed group after loading (FGA). Orthodontic force was applied to both the NFG and FGA. Failed mini-implants after insertion, ratio of FGA to NFG according to loading time after insertion, and failed mini-implants according to failed time after loading were analyzed. Results: Percentages of failed mini-implants after insertion were 15.79%, 36.84%, 12.28%, and 10.53% at 4, 8, 12, and 16 weeks, respectively. Mini-implant failure demonstrated a peak from 4 to 5 weeks after insertion. The failure rates according to loading time after insertion were 13.56%, 8.97%, 11.32%, and 5.00% at 4, 8, 12, and 16 weeks, respectively. Percentages of failed mini-implants after loading were 13.79%, 24.14%, 20.69%, and 6.9% at 4, 8, 12, and 16 weeks, respectively. Conclusion: Mini-implant stability is typically acquired 12 to 16 weeks after insertion, and immediate loading can cause failure of the mini-implant. Failure after loading was observed during the first 12 weeks.

Computational viscoelastic modeling of strain rate effect on recycled aggregate concrete

  • Suthee Piyaphipat;Boonchai Phungpaingam;Kamtornkiat Musiket;Yunping Xi
    • Computers and Concrete
    • /
    • 제32권4호
    • /
    • pp.383-392
    • /
    • 2023
  • The mechanical properties of Recycled Aggregate Concrete (RAC) with 100 percent Recycled Coarse Aggregate (RCA) under loading rates were investigated in depth. The theoretical model was validated utilizing the RAC elastic modulus obtained from cylindrical specimens subjected to various strain rates. Viscoelastic theories have traditionally been used to describe creep and relaxation of viscoelastic materials at low strain rates. In this study, viscoelastic theories were extended to the time domain of high strain rates. The theory proposed was known as reversed viscoelastic theory. Normalized Dirichlet-Prony theory was used as an illustration, and its parameters were determined. Comparing the predicted results to the experimental data revealed a high level of concordance. This methodology demonstrated its ability to characterize the strain rate effect for viscoelastic materials, as well as its applicability for determining not only the elastic modulus for viscoelastic materials, but also their shear and bulk moduli.

개선된 여과형 시설의 비점오염물질 처리효율 평가 (Treatment Efficiency of Non-Point Source Pollutants Using Modified Filtration System)

  • 강희만;최지연;김이형;배우근
    • 한국습지학회지
    • /
    • 제13권2호
    • /
    • pp.161-169
    • /
    • 2011
  • 본 연구는 여과와 침투기작을 이용한 개선된 여과형 시설의 비점오염물질 처리효율을 평가하고자 수행되었다. 저감시설은 지리학적 기후학적인 인자를 고려하여 기존의 저감시설의 단점을 보완하여 설계되었다. 저감시설의 처리효율 평가는 실험실 규모로 수행되었으며, 3가지 유형의 유속[초기강우(120 mL/min), 일반적인 강우(242 mL/min), 집중호우(500 mL/min)]을 적용하여 실험을 진행하였고, 이를 통하여 수질 분석 및 물수지를 산정하였다. 실험결과, 저감시설의 입자상 물질 제거 효율은 90%이상으로 높게 분석되었다. 3가지의 유속변화 실험 중, 집중호우의 경우에서 11~91% 범위로 낮은 제거효율을 보였는데, 이는 다른 유속에 비해 짧은 체류시간을 갖기 때문으로 판단된다. 또한 저감시설의 물수지 산정결과 침투량은 유출량의 약 1%에 불과하여 향후 저감시설 설계 시, 침투를 증가시키기 위해서 시설하부의 토양치환 등을 통한 침투량 및 저류량을 증가시킬 수 있는 기술적 접근이 필요하며, 이는 오염물질의 저감에 크게 기여할 것으로 판단된다.

폭기식 잠수여상을 이용한 고밀도 양식장의 순환수 처리 -1. 해수중의 암모니아 제거 특성- (The Recycling Water Treatment of High Density Fish Culture System Using the Aerated Submerged Filter -1. Ammonia Removal Characteristics in Sea Water-)

  • 이헌모;이재관;정병곤;양병수
    • 한국수산과학회지
    • /
    • 제26권5호
    • /
    • pp.502-509
    • /
    • 1993
  • Submerged filter process was used to evaluate the nitrifying efficiency of ammonia in the recycling water of marine aquatic culture system. The ammonia removal efficiency was achieved as high as $99\%$ at the hydraulic surface loading rate of up to $4.3{\ell}/m^2-day$. And the nitrite accumulation did not occur in the reactor even when the hydraulic surface loading rate of up to $36.8{\ell}/m^2day$ was applied. In the present study, the relationship between the effluent ammonia concentration and ammonia surface loading rate was formulated as an equation. The attachment rate of biofilm on the filter media at the ammonia surface loading rate of 62.3 and $311.7mg/m^2day$ was 15 and $55mg/m^2-day$, respectively, showing the linear relationship between the attachment rate and ammonia loading rates. Biofilm thickness and density of the filter media were found to be the function of the ammonia loading rate.

  • PDF

미성숙 돼지 난자의 유리화 동결에 관한 연구: Open Pulled Straw(OPS), Electron Microscopic Grid(EMG) 및 Nylon Loop System(NLS)의 비교 (Study of Vitrification of Immatured Pig Oocytes: Compared with Open Pulled Straw(OPS), Electron Microscopic Grid(EMG) and Nylon Loop System(NLS))

  • 김인덕;안미현;석호봉
    • 한국수정란이식학회지
    • /
    • 제19권1호
    • /
    • pp.27-34
    • /
    • 2004
  • This study evaluated the efficiency and compared with different materials of loading vessels for vitrification-plastic/glass, copper grid and nylon. The loading method, vitrification, cryop-reservation and warming method of the oocytes were examined. The loading samples prepared in manual or company-made and sterilized, loaded the COCs selected on each samples and cultured for maturation during 40 hours, and then exposed sequentially to ethylene glycol solution. Thawing method was reversely treated and exposed for warmed oocytes. After oocytes were thawed, fertilized and cultured in vitro for 3-4 hours, rates of development and morphological appearance were examined. The results were as summarized: ㆍOPS from company-made or hand-made of the hematocrit micropipettes, NLS from fishing line and EMG from company-made for EM were used for loading oocytes, respectively. ㆍThe efficiency of freezing method and loading convenience were orderly higher in OPS, NLS and EMG. The optimal capacity per vessel was orderly lowered in NLS, EMG and OPS, respectively. ㆍAfter oocytes were warmed, the recovery rate, morphology and rate of development were orderly higher in OPS, NLS and EMG, respectively. ㆍIn conclusion, OPS has the advantages of achieving a little more survival and preserving results than other two loading methods.

P92와 STS 316L강의 고온 피로 균열 성장에 미치는 하중 파형의 영향 (The Effect of Loading Waveform on the High Temperature Fatigue Crack Propagation in P92 and STS 316L Steel)

  • 김수영;임병수
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.136-140
    • /
    • 2002
  • High temperature fatigue crack growth behavior of P92 and STS 316L steel were investigated under four load conditions using CT type specimens. Loading and unloading times for the low wave forms were combinations of 1 sec. and 50 sec., which were two symmetric wave forms and two unsymmetric wave forms. Their behaviors are characterized using ΔK parameter. In STS 316L, Crack growth rate generally increases as frequency decreases. However, sensitivity of the loading rate to crack growth rate was fecund to be far greater than that of the unloading time. It is because as loading time increases, creep occurs at crack tip causing the crack growth rate to increase. However creep does not occur at the crack tip even if the unloading time is increased. In P92 steel, crack growth rate showed same behavior as in STS 316L. But the increase in loading or unloading time made almost no difference in crack growth rate, suggesting that no significant creep occurs in P92 steel even though loading time increases. After conducting high temperature tensile tests and comparing high temperature fatigue crack growth rates under various wave forms, it was proved that P92 steel has not only good high temperature properties but also improved, better high temperature fatigue properties than STS 316L.

입자 및 필터 대전상태에 따른 입자부하조건에서 공기정화 필터의 여과특성 (Influence of Particle and Filter Charge on Filtration Property of Air Filter under Particle Loading)

  • 지성미;손종렬;박현설
    • 한국대기환경학회지
    • /
    • 제28권6호
    • /
    • pp.644-655
    • /
    • 2012
  • As soon as a new air filter is applied to an air purification process, the filter gets loaded with dust particles. Thus, the study on the particle loading characteristics of air filter is very essential in order to understand the real filtration phenomena during filter use. In this study, we investigated the effect of particle and filter charge on the particle loading property of air filter. Charged filter and uncharged filter prepared by discharging the charged filter by isopropyl alcohol were used as test samples, and three types of particle having different charge states were supplied to filters tested. For neutralized particles there was a big difference in areal mass loading rates between charged and uncharged filters due to the very small amount of particle charge, on the other hand the difference was diminished for atomized particle and finally almost vanished for corona charged particles. The pressure drop of filter loaded with corona charged particles was only half of those for neutralized and atomized particles at the same areal mass loading because of the porous structure of particle deposit formed on filter fibers, caused by the space charge effect between particles.

페닐프로피온산계 해열진통제 고형지질나노입자의 입도분포와 약물봉입 및 용출특성 (Particle Size Distribution, Drug Loading Capacity and Release Profiles of Solid Lipid Nanoparticles of Phenylpropionic Acids)

  • 김윤선;김길수
    • Journal of Pharmaceutical Investigation
    • /
    • 제28권4호
    • /
    • pp.249-255
    • /
    • 1998
  • Solid Lipid Nanoparticle(SLN), one of the colloidal carrier systems, has many advantages such as good biocompatibility, low toxicity and stability. In this paper, the effects of drug lipophilicity and surfactant on the drug loading capacity, particle size and drug release profile were examined. SLNs were prepared by homogenization of melted lipid dispersed in an aqueous surfactant solution. Ketoprofen, ibuprofen and pranoprofen were used as model drugs and tweens and poloxamers were tested for the effect of surfactant. Mean particle size of prepared SLNs was ranged from 100 to 150nm. The drug loading capacity was improved with the most lipophilic drug and low concentration of surfactant. Particle size and polydispersity of SLNs were changed according to the used lipid and surfactant. The rates of drug release were controlled by the loading drug and surfactant concentration. SLN system with effective drug loading efficiency and proper particle size for the intravenous or oral formulation can be prepared by selecting optimum drug and surfactant.

  • PDF