• Title/Summary/Keyword: loading level

Search Result 1,190, Processing Time 0.098 seconds

Effect of Acute Unilateral Ureteral Obstruction on Handling of $Li^+$ by Contralateral Kidney in Rabbits (급성 일측 수뇨관 폐쇄후 상대신의 $Li^+$처리에 관한 연구)

  • Sung, Ho-Kyung;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.16 no.2
    • /
    • pp.165-175
    • /
    • 1982
  • Changes in handling of $Li^+$ by contralateral kidney during acute $Li^+$ loading were investigated immediately after unilateral ureteral obstruction. Carotid artery, jugular vein, renal vein and ureter of experimental animal were catheterized and renal venous flow was shunted to .external jugular vein. In experimental group right ureter was ligated. One to two hours after operation a single shot of LiCl solution (2 mEq/kg) was intravenously injected and then .arterial, renal venous blood and urine samples were taken sequentially for 1 to $1{\frac{1}{2}}$ hours. Urine volume, plasma and urinary concentrations of $Li^+$, $Na^+$ and $K^+$ were measured and urinary excretion of them were calculated. Results obtained were as follows: 1) In experimental group urine volume, urinary excretion of $Na^+$, and $K^+$ by contralateral kidney after unilateral ureteral obstruction were slightly larger than mean value of both kidney in control group. 2) During acute $Li^+$ loading contralateral kidney in experimental group showed limited $K^+$ excretion, but urinary flow and $Na^+$ excretion were comparable to mean value of both kidney in control group. 3) Urinary osmolar concentration in experimental group was much lower than that in control group, and it was maintained at low level even after Li loading. 4) In experimental group plasma$Li^+$ concentration decreased more slowly than in control group after a single shot of LiCl solution. 5) Urinary excretion of $Li^+$ in experimental group was markedly decreased, even lesseer than mean of both kidney in control group. 6) From the above results it was concluded that immediately after unilateral ureteral obstruction contralateral kidney showed normal water and $Na^+$ diuretic response to Li load but urinay $Li^+$ excretion was decreased and reclaimed $Li^+$ to systemic circulation.

  • PDF

Effect of PVOH or polyDADMAC Addition on Surface Sizing with Oxidized Starch (PVOH와 polyDADMAC 첨가에 의한 산화전분의 표면사이징 효과 변화)

  • Seo, Dongil;Jeong, Young Bin;Jeong, Kwang Ho;Lee, Hak Lae;Youn, Hye Jung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.45 no.4
    • /
    • pp.1-8
    • /
    • 2013
  • High loading of printing and writing grades with fillers has many advantageous aspects in papermaking because it allows decreasing fiber use and reducing manufacturing cost. High loading technology, however, has some disadvantageous aspects as well. It decreases physical properties of papers, especially strength properties. The problem associated with high loading can be reduced by applying surface sizing starch solution onto paper surface. It is important to control the penetration of the surface sizing starch solution into paper web to obtain the desired property improvement. In this study, the effect of the addition of two polymers into starch solution on paper properties has been examined. PVOH and polyDADMAC were used as polymeric additives for surface sizing with oxidized starch. Viscosity of starch solutions and surface roughness of dried starch films on glass slides showed that some interactions between polymeric additives and oxidized starch have been occurred and the most extensive interaction with starch solution was obtained with high molecular weight polyDADMAC. Low molecular weight PVOH was most effective in improving folding endurance and internal bond strength. On the other hand, polymer addition showed no effect on surface strength of paper. This indicates that not the level of starch holdout but the bonding strength of starch itself has predominant influence on surface strength of paper.

An Experimental Study on Silty Clay Subjected to Repeated Loads (반복하중을 받는 실트질 점토에 관한 실험적 연구 -과압밀 점토를 중심으로-)

  • Kim, Pal-Gyu;Kim, Gyeong-Jin;Song, Jeon-Seop
    • Geotechnical Engineering
    • /
    • v.5 no.4
    • /
    • pp.37-46
    • /
    • 1989
  • The object of this paper is to study the general characteristics of overconsolidated silty clays subjected to repeated loading. The samples are first remolded. overconsolidated and a series of strain - controlled triaxial repeated tests are carried out. Generally the relationship of deviator stress - axial strain of overconsolidated clay is similar in pattern to the normally consolidated clay under single load. But the behavior of the pore water pressure build up in the sample subjected to repeated loading is dependent upon the consolidation history and the level of repeated stress. Therefore through the series of the tests, the characteristics of stress -strain relationship of soils which are differentlly overconsolidated are investigated, analysed and then compared with each soils. And also, from the relationship of test results, the strength and strain characteristics of soils are obierved. The equilibrium lines which presents the critical repeated stress and equilibrium state in the sample under repeated loading, are often straight, but may be curved. And the tendency of the equilibrium lines is observed as to the variation of overconsolidation ratio.

  • PDF

STUDY ON RADIOGRAPHIC EVALUATION OF MARGINAL BONE LOSS AROUND OSSEOINTEGRATED IMPLANT AFTER FUNCTIONAL LOADING (기능적 부하 후 임플란트 주변의 골 흡수에 대한 방사선학적 연구)

  • Choi, Su-Jin;Chee, Young-Deok;Koh, Se-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.240-247
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate marginal bone loss to the bone crest functionally loaded for up to eighteen months and also with regard to other variables of interest. Material and Methods: 135 endosseous implants(GS II, Osstem, South Korea) were placed in 35 patients. The design of GS II implant is straight with the microthread. Radiographic examinations were conducted at baseline (implant loading) and 3, 6, 9, 12 and 18 months after loading. Marginal bone level measurement was made from the reference point to the lowest observed point of contact of the marginal bone with the fixture. The reference point of the fixture was the border between the blasted surface and machined surface of the fixture. Results: Implants were on function for a mean 12.7 months(range, 3?18 months). For the 56 maxillary and 79 mandibular implants, mean marginal bone loss was 0.68 mm and 0.70 mm. Implants placed maxillary posterior area displayed more crestal bone loss than the other position. The difference between mesial and distal bone levels was statistically significant (p<0.05) with respective means of 0.51 mm and 0.62 mm. Also, The difference between bone graft group and no-bone graft group was statistically significant(p<0.05) with respective means of 0.38 mm and 0.66 mm. But no statistically significant influence of sex, type of surgery(one or two stage surgery), the implant length was observed(p>0.05). Conclusion: This study indicates the amount of marginal bone loss around implant has maintained a relative stable during follow-up periods.

Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant

  • Yoon, Ki-Joon;Park, Young-Bum;Choi, Hyunmin;Cho, Youngsung;Lee, Jae-Hoon;Lee, Keun-Woo
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.465-471
    • /
    • 2016
  • PURPOSE. The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. MATERIALS AND METHODS. Sixteen external hex implant fixtures were assigned to two groups (CCM and Gold group) and were embedded in molds using clear acrylic resin. Screw-retained prostheses were constructed using CCM UCLA abutment and Gold UCLA abutment. The external implant fixture and screw-retained prostheses were connected using abutment screws. After the abutments were tightened to 30 Ncm torque, 5 kg thermocyclic functional loading was applied by chewing simulator. A target of $1.0{\times}10^6$cycles was applied. After cyclic loading, removal torque values were recorded using a driving torque tester, and the interface between implant fixture and abutment was evaluated by scanning electronic microscope (SEM). The means and standard deviations (SD) between the CCM and Gold groups were analyzed with independent t-test at the significance level of 0.05. RESULTS. Fractures of crowns, abutments, abutment screws, and fixtures and loosening of abutment screws were not observed after thermocyclic loading. There were no statistically significant differences at the recorded removal torque values between CCM and Gold groups (P>.05). SEM analysis revealed that remarkable wear patterns were observed at the abutment interface only for Gold UCLA abutments. Those patterns were not observed for other specimens. CONCLUSION. Within the limit of this study, CCM UCLA abutment has no statistically significant difference in the stability of interface with external hex implant, compared with Gold UCLA abutment.

An Assessment Study of Seismic Resistance of Two-story Wood-frame Housing by Shaking Table Tests

  • Ni, Chun;Kim, Sang-Yeon;Chen, Haijiang;Lu, Xilin
    • Land and Housing Review
    • /
    • v.3 no.1
    • /
    • pp.79-82
    • /
    • 2012
  • While there exists a relatively large body of technical information for the engineered design of wood-frame buildings to resist seismic ground motions, the quantitative assessment of seismic resistance of conventional houses built by prescriptive requirements is less well understood. Forintek Canada Corp., in collaboration with other research and industry partners, has embarked on a research project to address this topic. This paper will report on the seismic shake table tests of a full-scale wood-frame building. The two-story specimen, $6m{\times}6m$ in plan, was built on the seismic shake table at Tongji University in Shanghai, China, according to Part 9 of the 1995 National Building Code of Canada and shaken uni-directionally in each of the two principal directions. Three different seismic table motions were applied at increasing peak ground motion amplitudes up to 0.40 and 0.50 g. The specimen was repaired after the above sets of seismic table motions, and successive runs were conducted for increased door openings. Measurements included specimen accelerations, displacements and anchorage forces. Static stiffness of the specimen was measured at low force levels, and natural frequencies were measured after each seismic loading stage by applying low-level random excitation. The results presented consist of the capacity spectra of the shake table tests, changes in specimen stiffness and natural frequencies with increasing seismic loading. These results and those from other recent shake table tests elsewhere will be compared with simplified engineering calculations based on codified values of strength, and on that basis preliminary conclusions will be drawn on the adequacy of the current code provisions and design guides in Canada and the USA for conventional wood-frame construction.

Tension-Compression Asymmetry in the Off-Axis Nonlinear Rate-Dependent Behavior of a Unidirectional Carbon/Epoxy Laminate at High Temperature and Incorporation into Viscoplasticity Modeling

  • Kawai, M.;Zhang, J.Q.;Saito, S.;Xiao, Y.;Hatta, H.
    • Advanced Composite Materials
    • /
    • v.18 no.3
    • /
    • pp.265-285
    • /
    • 2009
  • Off-axis compressive deformation behavior of a unidirectional CFRP laminate at high temperature and its strain-rate dependence in a quasi-static range are examined for various fiber orientations. By comparing the off-axis compressive and tensile behaviors at an equal strain rate, the effect of different loading modes on the flow stress level, rate-dependence and nonlinearity of the off-axis inelastic deformation is elucidated. The experimental results indicate that the compressive flow stress levels for relatively larger off-axis angles of $30^{\circ}$, $45^{\circ}$ and $90^{\circ}$ are about 50 percent larger than in tension for the same fiber orientations, respectively. The nonlinear deformations under off-axis tensile and compressive loading conditions exhibit significant strain-rate dependence. Similar features are observed in the fiber-orientation dependence of the off-axis flow stress levels under tension and compression and in the off-axis flow stress differential in tension and compression, regardless of the strain rate. A phenomenological theory of viscoplasticity is then developed which can describe the tension-compression asymmetry as well as the rate dependence, nonlinearity and fiber orientation dependence of the off-axis tensile and compressive behaviors of unidirectional composites in a unified manner. It is demonstrated by comparing with experimental results that the proposed viscoplastic constitutive model can be applied with reasonable accuracy to predict the different, nonlinear and rate-dependent behaviors of the unidirectional composite under off-axis tensile and compressive loading conditions.

Fatigue Evaluation for the Socket Weld in Nuclear Power Plants

  • Choi, Young Hwan;Choi, Sun Yeong;Huh, Nam Soo
    • Corrosion Science and Technology
    • /
    • v.3 no.5
    • /
    • pp.216-221
    • /
    • 2004
  • The operating experience showed that the fatigue is one of the major piping failure mechanisms in nuclear power plants (NPPs). The pressure and/or temperature loading transients, the vibration, and the mechanical cyclic loading during the plant operation may induce the fatigue failure in the nuclear piping. Recently, many fatigue piping failure occurred at the socket weld area have been widely reported. Many failure cases showed that the gap requirement between the pipe and fitting in the socket weld was not satisfied though the ASME Code Sec. III requires 1/16 inch gap in the socket weld. The ASME Code OM also limits the vibration level of the piping system, but some failure cases showed the limitation was not satisfied during the plant operation. In this paper, the fatigue behavior of the socket weld in the nuclear piping was estimated by using the three dimensional finite element method. The results are as follows. (1) The socket weld is susceptible to the vibration if the vibration levels exceed the requirement in the ASME Code OM. (2) The effect of the pressure or temperature transient load on the socket weld in NPPs is not significant because of the very low frequency of the transient during the plant lifetime operation. (3) 'No gap' is very risky to the socket weld integrity for the specific systems having the vibration condition to exceed the requirement in the ASME OM Code and/or the transient loading condition. (4) The reduction of the weld leg size from $1.09*t_1$ to $0.75*t_1$ can affect severely on the socket weld integrity.

Marco and Microscopic Observations of Fatigue Crack Growth Behavior in API 2W Gr. 50 Steel Joints (API 2W Gr. 50 강재 용접부의 피로균열전파거동의 거시적 및 미시적 관찰)

  • Sohn, Hye-Jeong;Kim, Seon-Jin
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.5
    • /
    • pp.73-80
    • /
    • 2012
  • It is well known that a considerable amount of scatter is shown in experimental results relating to fatigue crack growth even under identical and constant amplitude cyclic loading conditions. Moreover, flux cored arc welding (FCAW) is a common method used to join thick plates such as the structural members of large scale offshore structures and very large container ships. The objective of this study was to investigate the macro- and microscopic observations of the fatigue crack growth (FCG) behavior of the FCAWed API 2W Gr. 50 steel joints typically applied for offshore structures. In order to clearly understand the randomness of the fatigue crack growth behavior in the materials of three different zones, the weld metal (WM), heat affected zone (HAZ), and base metal (BM), experimental fatigue crack growth tests for each of five specimens were performed on ASTM standard compact tension (CT) specimens under constant amplitude cyclic loading. Special focus was placed on the fatigued fracture surfaces. As a result, a different behavior was observed at the macro-level, depending on the type of material property: BM, HAZ, or WM. The variability in the fatigue crack growth rate for WM was higher than that of BM and HAZ.

Improvement in Sensitivity by Increasing the Frequency of SAW Sensors for DNA Detection (DNA 측정용 SAW 센서의 주파수 증대에 의한 감도향상)

  • Sakong, Jung-Yul;Kim, Jae-Ho;Lee, Soo-Suk;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.42-47
    • /
    • 2007
  • In this paper. we have studied improvement in sensitivity by increasing the frequency of SAW sensors for detecting the immobilization and hybridization of DNA. The sensor consists of twin SAW delay lines operating at 200MHz, a sensing channel and a reference channel. fabricated on $36^{\circ}$ rotated Y-cut X-propagation $LiTaO_3$ crystals. The optimum concentration of probe and target DNA was decided for the improvement of detection mechanism. and digital syringe pump system was used to reduce the human errors. The hybridization between immobilized probe DNA and target DNA on the gold-coated delay line results in mass loading on the delay line of the sensing channel. Thus, the relative frequency change was monitored in relation to the mass loading. The measurement results showed a good response of the sensor to the DNA hybridization with a maximum sensitivity level up to 0.066ng/m1/Hz.