• Title/Summary/Keyword: loading height

Search Result 518, Processing Time 0.02 seconds

The Influences for Change of energy consumption of normal 20s' adults during gait (20대 정상성인의 발목에 부가된 하중이 보행중 에너지 소모도에 미치는 영향)

  • Kim, Yong-Gun;Han, Dong-Uck
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.1
    • /
    • pp.285-294
    • /
    • 2000
  • 80 persons who don't have past history of cardiopulmonary and neuromuscular disease. The results were as follow; 1. PCI(Physiological Cost Index) value without loading to ankle were significantly increased compared to 1kg, and 2kg (p<0.01). 2. Female Subjects showed more increased PCI value in without loading and lkg, 2kg loading compared to male subjects (p<0.01). 3. In every PCI condition the difference among height groups was observed (p<0.01). 4. The difference among weight groups in each PCI condition was observed (p<0.01). These results showed that energy consumption was increased according to loading on the ankle during gait so weight of orthosis or prosthesis must be considered when choosing them and during gait training with these ones.

  • PDF

System identification and reliability assessment of an industrial chimney under wind loading

  • Tokuc, M. Orcun;Soyoz, Serdar
    • Wind and Structures
    • /
    • v.27 no.5
    • /
    • pp.283-291
    • /
    • 2018
  • This study presents the reliability assessment of a 100.5 m tall reinforced concrete chimney at a glass factory under wind loading by using vibration-based identified modal values. Ambient vibration measurements were recorded and modal values such as frequencies, shapes and damping ratios were identified by using Enhanced Frequency Domain Decomposition (EFDD) method. Afterwards, Finite Element Model (FEM) of the chimney was verified based on identified modal parameters. Reliability assessment of the chimney under wind loading was performed by obtaining the exceedance probability of demand to capacity distribution. Demand distribution of the chimney was developed under repetitive seeds of multivariate stochastic wind fields generated along the height of chimney. Capacity distribution of the chimney was developed by Monte Carlo simulation. Finally, it was found that reliability of the chimney is lower than code suggested limit values.

Optimal design of spoke double-layer cable-net structures based on an energy principle

  • Ding, Mingmin;Luo, Bin;Han, Lifeng;Shi, Qianhao;Guo, Zhengxing
    • Structural Engineering and Mechanics
    • /
    • v.74 no.4
    • /
    • pp.533-545
    • /
    • 2020
  • An optimal design method for a spoke double-layer cable-net structure (SDLC) is proposed in this study. Simplified calculation models of the SDLC are put forward to reveal the static responses under vertical loads and wind loads. Next, based on an energy principle, the relationship among the initial prestress level, cross-sectional areas of the components, rise height, sag height, overall displacement, and relative deformation is proposed. Moreover, a calculation model of the Foshan Center SDLC is built and optimized. Given the limited loading cases, material properties of the components, and variation ranges of the rise height and sag height, the self-weight and initial prestress level of the entire structure can be obtained. Because the self-weight of the cables decreases with increasing of the rise height and sag height, while the self-weight of the inner strut increases, the total weight of the entire structure successively exhibits a sharp reduction, a gradual decrease, a slow increase, and a sharp increase during the optimization process. For the simplified model, the optimal design corresponds to the combination of rise height and sag height that results in an appropriate prestress level of the entire structure with the minimum total weight.

Evaluation of Effective Working Days in a Harbor Considering Harbor Resonance and Moored Ship Motion (항만공진주기와 선박동요량을 고려한 항만가동율 산정)

  • Kwak, Moonsu;Moon, Yongho
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.1
    • /
    • pp.14-24
    • /
    • 2015
  • This study proposed an estimation method of allowable wave height for loading and unloading of the ship and evaluation of effective working days considering moored ship motion that is affected by sip sizes, mooring conditions, wave periods and directions. The method was examined validity by comparison with wave field data at pier $8^{th}$ in Pohang New Harbor. The wave field data obtained with wave height of 0.10~0.75 m and wave period of 7~13 s in ship sizes of 800~35,000 ton when a downtimes have occurred. On the other hand, the results of allowable wave height for loading and unloading of the ship in this method have obtained with wave heights of 0.19~0.50 m and wave periods of 8~12 s for ship sizes of 5,000, 10,000 and 30,000 ton. Thus this method well reproduced the field data respond to various a ship sizes and wave periods. And the results of this in Korea are didn't respond to various the ship sizes and wave periods, and we h method tended to decrease in 16~62 percent when have considered long wave, and it is decreased in 0~46 percent when didn't consider long wave than design standards in case of the ship sizes of 5,000~30,000 ton, wave period of 12 s and wave angle of $75^{\circ}$. The allowable wave heights for loading and unloading of the ship proposed by design standards in Korea have found that overestimated on smaller than 10,000 ton. On the other hand, the rate of effective working days considering ship motion at pier $8^{th}$ in Pohang New Harbor reduced in 6.5 percent when compare with the results without considering ship motion.

Stability of A Surcharged Tunnel under the Effect of Pre-Loading on the Adjacent Braced Wall (근접한 흙막이벽체에 가하는 선행하중의 영향을 받는 상재하중 재하 터널의 안정)

  • Kim, IL;Lee, Sang Duk
    • Journal of the Society of Disaster Information
    • /
    • v.4 no.2
    • /
    • pp.10-27
    • /
    • 2008
  • When the ground is excavated adjacent to the existing tunnel, which is loaded by the surcharge on the ground surface, the tunnel stability would be very sensitive to the deformation of the ground induced by the horizontal displacement of braced wall. The stability of the existing surcharged tunnel could be controlled by pre-loading on the braced wall. In this paper, it was investigated, if it would be possible to keep the existing surcharged tunnel stable by preventing the horizontal displacement of a braced wall by imposing the pre-loading during the ground excavation. For this purpose, large scale model tests were performed in a scale 1/10 at the test pit which was 2.0m in width and 6.0m in height and 4.0m in length. Isotropic test ground was constructed homogeneously by wet sand. Model tunnel was constructed in the test ground. Surcharge was loaded on the ground surface above the tunnel. During the tests, the behavior of model tunnel and model braced wall was measured. Numerical analyses were also performed in the same condition as the tests. And their results were compared to that of the model tests. Consequently, the effect of a surcharge could be compensated by imposing the pre-loading on the braced wall. The existing tunnel and the braced wall could be kept stable by preventing the horizontal displacement of the braced wall through pre-loading, although the tunnel is surcharged.

  • PDF

Low velocity impact behavior of concrete beam strengthened with CFRP strip

  • Kantar, Erkan;Anil, Ozgur
    • Steel and Composite Structures
    • /
    • v.12 no.3
    • /
    • pp.207-230
    • /
    • 2012
  • Nowadays CFRP (Carbon Fiber Reinforced Polymer) became widely used materials for the strengthening and retrofitting of structures. Many experimental and analytical studies are encountered at literature about strengthening beams by using this kind of materials against static loads and cyclic loads such as earthquake or wind loading for investigating their behavior. But authors did not found any study about strengthening of RC beams by using CFRP against low velocity impact and investigating their behavior. For these reasons an experimental study is conducted on totally ten strengthened RC beams. Impact loading is applied on to specimens by using an impact loading system that is designed by authors. Investigated parameters were concrete compression strength and drop height. Two different sets of specimens with different concrete compression strength tested under the impact loading that are applied by dropping constant weight hammer from five different heights. The acceleration arises from the impact loading is measured against time. The change of velocity, displacement and energy are calculated for all specimens. The failure modes of the specimens with normal and high concrete compression strength are observed under the loading of constant weight impact hammer that are dropped from different heights. Impact behaviors of beams are positively affected from the strengthening with CFRP. Measured accelerations, the number of drops up to failure and dissipated energy are increased. Finite element analysis that are made by using ABAQUS software is used for the simulation of experiments, and model gave compatible results with experiments.

Detection of Ocean Tide Loading Constituents Based on Precise Point Positioning by GPS (GPS 정밀단독측위기법을 이용한 해양조석하중 분조성분 검출)

  • Won, Ji-Hye;Park, Kwan-Dong
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.4
    • /
    • pp.511-520
    • /
    • 2009
  • In this study, the Ocean Tide Loading (OTL) constituents were detected by the Precise Point Positioning (PPP) technique using GPS. Then, the GPS estimates of OTL constituents were compared with the predictions of the ocean tide models. We picked three permanent GPS stations as test sites and they are ICNW, SEOS, and CJUN. To detect the OTL constituents using GPS, we created vertical coordinate time series at 10-minute intervals using the PPP approach implemented in the GIPSY software. Through the tidal harmonic analysis of this height time series, the four major constituents ($M_2$, $S_2$, $K_1$, $O_1$) were determined. The amplitude obtained from the GPS height time series of the OTL constituents showed best match with the model predictions at CJUN, while the phase showed closest match at ICNW. The amplitude accuracy of the $M_2$, which is the dominant factor out of the 11 major constituents, was 24.8% on average.

Flexural Behavior of Steel-Concrete Composite Beams Strengthened by Post Tension Method (포스트 텐션 공법으로 보강된 SC 합성보의 휨 거동)

  • Ryu, Soo-Hyun;Kim, Heui-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.3
    • /
    • pp.186-195
    • /
    • 2010
  • This study has attempted to suggest a proper reinforcement method by strengthening unbonded post -tensioning through height of an anchorage hole, form of a saddle, and loading time point as parameters and evaluating the reinforcement method through a bending experiment. The result of this experiment indicated effects of reinforcement since the maximum strength ratio(the ratio of an experimental value to theoretical value) of SC composite beams before prestressed was 0.97 and after prestress were 1.00~1.21. As a result of analysis on displacement and strain, irrespective of height of an anchorage hole and loading time point, the D120-series specimen where an anchorage hole was installed on the neutral axis after reinforcement showed that its deflection continuously increased without sudden load reduction after maximum load and it stably behaved with relatively low strain of each part. In terms of reinforcement effects, the maximum strength of SCR-UD120 specimen prestressed after pre-loading was increased 1.72 times comparing to SC composite beams so SCR-UD120 specimen prestressed after pre-loading was shown to be the best.

Required Time for Isotopic and Ko Consolidation of Marine Clay in Triaxial Cell (삼축셀에서 해성점토의 등방 및 Ko 압밀소요 시간)

  • Lee, Kyeong-Jun;Jung, Du-Hwoe;Im, Jong-Chul
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.8
    • /
    • pp.137-147
    • /
    • 2007
  • Isotropic (instant loading) and Ko (gradual increase loading) consolidation tests were conducted in triaxial test equipment using cylindrical sample (5.0 cm in diameter and 10.0 cm in height) on two marine clay deposits. The duration of primary consolidation was estimated by two curve fitting methods using measured strain. A differential equation of consolidation for drainage in the radial and vertical direction was solved by the implicit finite difference scheme. The results of two curve fitting methods were compared with the numerical solutions to evaluate the appropriate axial loading rate of Ko consolidation and the primary consolidation periods. In addition, primary consolidation periods of the samples with a diameter of 35 mm and a height of 70 mm were calculated. The relation of radial and vertical consolidation coefficients is also presented.

Assessment of Equivalent Heights of Soil for the Lateral Earth Pressure Against Retaining Walls Due to Design Truck Load by 3D Numerical Analysis (3차원 수치해석에 의한 표준트럭하중에 의해 옹벽에 작용하는 수평토압의 등가높이 산정)

  • Seo, Seunghwan;Jin, Hyunsik;Kim, Dongwook;Chung, Moonkyung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.75-85
    • /
    • 2019
  • The lateral load from traffic depends on standard truck's axle loads and locations, loading distance from the inner wall. The method of limit state design has been adopted and used for design of roads in the Republic of Korea since 2015. The concept of equivalent height of soil accounting for traffic loading is often used for design of retaining walls to quantify the traffic loads transmitted to the inner wall faces. Due to the different characteristics of the standard design trucks between Korea and US (AASHTO), the direct use of the guidelines from AASHTO LRFD leads to incorrect estimation of traffic load effects on retaining walls. This paper presents the results of evaluation of equivalent height of soil to reflect the standard truck of the nation, based on the findings from analytical solutions using 3D finite element method. Compare to US, the standard truck loading has a structure where the axle load is concentrated so that the equivalent load height is estimated to be slightly larger than AASHTO for lower retaining wall height. It would be reasonable to present the equivalent load height in Korea more conservatively than AASHTO in terms of securing long term stability of the retaining wall structure.