• Title/Summary/Keyword: loading capacity specification

Search Result 24, Processing Time 0.02 seconds

Determination of Earthquake Loads and Finite Element Analysis of Circular Water Reservoirs with a Large Size over 5,000 ton (5,000톤 이상 대용량 원형 배수지 구조의 지진력 산정 및 유한요소 해석)

  • Lee, Sang-Youl;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.25 no.2
    • /
    • pp.265-272
    • /
    • 2015
  • Finite element analyses were performed on large-sized (>5000 ton) stainless steel circular water reservoirs subjected to earthquake loading for different stainless steel materials. The earthquake load inputs for the analyses were selected by the guidelines in the Korean Standards Association specification KS B 6283. Seismic effects can be heavily dependent on water capacity, especially for large reservoirs. The numerical results show the interactions between the different load combinations and other parameters such as the water capacity and stainless steel materials. Structural performance is also evaluated for the various load combinations.

RRP Loading Patterns and Standard Dimensions for Block Pattern in Membership Wholesale Clubs (Membership Wholesale Club에서의 RRP 적재패턴 및 블록패턴 표준규격에 관한 연구)

  • Jung, Sung-Tae;Han, Kyu-Chul
    • Journal of Distribution Science
    • /
    • v.13 no.7
    • /
    • pp.41-51
    • /
    • 2015
  • Purpose - This study analyzes loading efficiency by loading pattern for package standardization and reduction of logistics costs, along with the creation of revenue for the revenue review panel (RRP) of Membership Wholesale Clubs (MWC). The study aims to identify standard dimensions that can help improve the compatibility of the pallets related to display patterns preferred by the MWC and thereby explore ways to enhance logistics efficiency between manufacturers and retailers through standardization. Research design, data, and methodology - The study investigates and analyzes the current status based on actual case examples, i.e., manufacturer A and Korea's MWC (A company, B company, and C company), and thus devises improvement measures. To achieve this, the case of manufacturer A delivering to MWC was examined, and the actual pallet display patterns for each MWC were investigated by visiting each distribution site. In this study, TOPS (Total Optimization Packaging Software, USA) was used as the tool for pallet loading efficiency simulations the maximum allowable dimension was set to 0.0mm to prevent the pallet from falling outside the parameters, and the loading efficiency was analyzed with the pallet area. In other words, the study focused on dimensions (length x width x height) according to the research purpose and thereby deduced results. Results - The analysis of pallet loading patterns showed that the most preferred loading patterns for loading efficiency according to product specification, such as pinwheel, brick, and block patterns, were used in the case of the general distribution products, but the products were configured with block patterns in most cases when delivered to MWCs. The loading efficiency by loading pattern was analyzed with respect to 104 nationally listed standard dimensions. Meanwhile, No.51 (330 × 220mm) of KS T 1002 (1,100 × 1,100mm) was found to be the dimension that could bring about an improved loading efficiency, over 90.0% simultaneously in both the T-11 and T-12 pallet systems in a loading pattern configuration with the block pattern only, and the loading efficiency simulation results also confirmed this as the standard dimension that can be commonly applied to both the T-11 pallet (90.0%) and the T-12 pallet (90.7%) systems. Conclusions - The loading efficiency simulation results by loading pattern were analyzed: For the T-11 pallet system, 17 standard dimension sizes displayed the loading efficiency of 90.0% or more as block patterns, and the loading capacity was an average of 99.0%. For the T-12 pallet system, 35 standard dimension sizes displayed the loading efficiency of more than 90% as block patterns (the average loading efficiency of 98.6%). Accordingly, this study proposes that the standard dimensions of 17 sizes with the average loading efficiency of 99.0% should be applied in the use of the T-11 pallet system, and those of 35 sizes with the average loading efficiency of 98.6% should be reviewed and applied in the use of the T-12 pallet system.

The Investigation Study of Compaction Density by Waste Composition Change in Landfill Site (매립장의 반입쓰레기 성상변화에 따른 다짐밀도 조사연구)

  • Jung, Byung-Gil;Choi, Young-Ik;Kim, Jung-Kwon
    • Journal of Environmental Science International
    • /
    • v.17 no.4
    • /
    • pp.397-403
    • /
    • 2008
  • The purpose of this study is to investigate weighted compaction density according to a leading density in truck, a compaction density of solid waste and composition ratios of solid waste fur calculation of a capacity of the landfill sites. The experiments for calculations of in-place density at landfill site have been conducted in S landfill site at B City. The size of vessel for measuring the compaction density was $1m^3(1m{\times}1m{\times}1m)$. The experiment tests have been carried out methods (1 time for bulldozer and 4 times for compactor) that do contain all of specification at the landfill site. Average of the loading density at the landfill site was $0.264\;ton/m^3$ ($0.113{\sim}0.487\;ton/m^3$). When the loading density for each compositions was compared, the composition of the highest average loading density ($0.474\;ton/m^3$) was miscellaneous wastes. The composition of the lowest average loading density ($0.120 ton/m^3$) was general solid waste. The reported results indicated that the compaction density at the landfill site was $0.538\;ton/m^3$, which was calculated with weighted incoming ratios of compositions. The ranges of the density for each composition were from $0.021\;ton/m^3$ to $0.221\;ton/m^3$. When the compaction density for each composition was compared, the composition with the highest average compaction density ($0.221\;ton/m^3$) was miscellaneous wastes. The composition with the lowest average compaction density ($0.021\;ton/m^3$) was general solid wastes.

A Study on the Propulsion and Braking Performance of the High Speed Freight Train with Composing the Rolling Stocks Formation (차량편성구성에 따른 고속화물열차의 추진 및 제동성능 분석 연구)

  • Han, Seong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.298-302
    • /
    • 2016
  • Currently, logistics are in small quantities and in diverse forms, and the amounts are continuously increasing. Railway logistics however are losing their market share every year mainly due to low operation speed and loading time, which means the trucks are covering the most of the freights. In order to solve these situations, this paper proposed the high speed freight train as working multi-modality with other modes to make effective transshipment. The high speed freight train has maximum operation speed of 300km/h and electric power to run centralized power supply. There are large dual door system, bogie system covering fluctuating load of 15[ton], automatic loading device, ULD(unit load device) bed and ULD locking system in this freight rolling stock. We calculated the performance of powering and braking capacity for this train and proposed how many vehicles are composed of train set. The results in this paper can help to make a decision to define the technical specification of High-speed freight train for the efficiency of rail freight service.

An Experimental Study on the Fatigue Strength of Repair Welded Joints of Old Steel Bridge (신판교체 보수 용접부의 피로강도에 관한 실험적 연구)

  • Park Hyeon-Chan;Lee Jin-Hyeong;Kim Jae-Hwan;Jang Gap-Cheol;Jang Gyeong-Ho
    • Proceedings of the KWS Conference
    • /
    • 2006.05a
    • /
    • pp.94-96
    • /
    • 2006
  • Recently, steel structures have been increasing because of its brilliant features. In general, cracks and corrosion are produced due to the numerous environmental factors in steel structures. However, the validity of repair method for the damaged steel structures has not been fully verified because of its lack of safety and reliability after application. Moreover, repair method by welding inevitably involves cutting and welding processes and reliability for the safety during the processes has net been established yet. Therefore, this study carried out experiments on the fatigue strength of repair welded joints of old steel bridge to investigate the fatigue characteristics in the repair welded joints. Fatigue tests were conducted by 250kN capacity MIS with the frequency of 5Hz under amplitude loading. From the results, it is known that fatigue strength grade of the repair welded joints was satisfied with C grade which specification requires.

  • PDF

Evaluation of Limiting Temperatures of Rectangular Hollow Sections (각형 강관기둥부재의 한계온도 평가 연구)

  • Kwon, In-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.331-332
    • /
    • 2012
  • Structural steel has been used as a primary materials to columns and beams since 1960's in Korea with an advantages of excellent of load-bearing capacity and design flexibility, and faster construction. However, if the steel columns made of structural steel exposed to fire the load-bearing capacity is going down steadily and finally reach to collapse. Therefore, building regulation requires fire resistance according to building occupation, scales. The fire resistance can be evaluated two categories. One is prescriptive method that is based on building regulation, specification and so on and the other is performance-based fire engineering method. The latter can be designed based on scientific and engineering consequences. The easiest evaluation way using the fire engineering design is comparing to the limiting temperature and maximum temperature calculated based on heat transfer theory. If the limiting temperature of a column exceeds the maximum temperature of it, the column can carry the load during the fire. Therefore, the database of limiting temperature is very essential for evaluation of column. In this paper, to build the database of column made of rectangular hollow sections 8 fire tests with loading were conducted and the relation between the limiting temperature and the applied loads showed in reverse proportion.

  • PDF

Study on the Bearing Capacity of Helical Pile through Field Load Tests (현장재하시험을 통한 헬리컬파일의 지지력에 관한 연구)

  • Kwon, Gi-Ryeol;Jang, Jeong-Wook;Cho, Song-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.11
    • /
    • pp.669-675
    • /
    • 2020
  • This research has focused on comparing the capacity predicted by the theoretical formula with the one measured by field load tests to examine characteristics of the bearing capacity of a helical pile. The helical pile is featured by a central shaft with one or more helical-shaped bearing plates. Being established by a small rotary attached to an excavator that applies toque, the helical piles can be readily constructed at narrow sites, especially in an urban area with relatively less noise than the others requiring driving and excavation. Although many cases of the helical pile constructions can be recently found, the bearing capacity of the pile has been limitedly studied. To this end, this contribution analyzes and presents comprehensive results of the ten field loading tests with an application of different parameters depending on joint condition and specification of the helical piles, and types of tests and grouting.

Seismic Performance Evaluation of Reinforced Concrete Bridge Piers with Lap Splices (철근의 겹침이음을 고려한 철근콘크리트 교각의 내진성능평가)

  • 김태훈;박현용;김병석;신현목
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.31-38
    • /
    • 2003
  • Lap splices were located in the plastic hinge region of most bridge piers that were constructed before the adoption of the seismic design provision of Korea Highway Design Specification on 1992. But sudden brittle failure of lap splices may occur under inelastic cyclic loading. The purpose of this study is to analytically predict nonlinear hysteretic behavior and ductility capacity of reinforced concrete bridge piers with lap splices under cyclic loading. For this purpose, a nonlinear analysis program, RCAHEST(Reinforced Concrete Analysis in Higher Evaluation System Technology) is used. Lap spliced bar element is developed to predict behaviors of lap spliced bar. Maximum bar stress and slip of lap spliced bar is also considered, The proposed numerical method for seismic performance evaluation of reinforced concrete bridge piers with lap splices is verified by comparison with reliable experimental results.

Evaluation and Application of Pullout Strength of Single Anchor in Plain Concrete According to Edge Distance (연단거리에 따른 무근콘크리트 단일앵커의콘파괴 인발 내력에 관한 적용성 평가)

  • Kim, Young-Ho;You, Sung-Gyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.1
    • /
    • pp.211-220
    • /
    • 2004
  • This paper presents the evaluation of pullout strengths of expansion anchors and wedge anchors that can cause a failure of the concrete on the basis of the design for anchorage. Tests are conducted for heavy-duty anchors and wedge anchors domestically manufactured and to be installed in plain concrete member. The mainly testing parameters reflected the effects of edge distance. Design of post-installed steel anchors is presented by the Concrete Capacity Design(CCD) in European Organization for Technical Approval. This approach is compared to the well-known provisions, ACI 349-90 specification. The use of both methods to predict the concrete failure load of expansion anchor in uncracked concrete under monotonic loading for important applications is compared. In this study, the concrete tension capacity of fastenings with Heavy-duty Anchors and Wedge Anchors in plain concrete predicted by ACI 349-90 and the Concrete Capacity Design method has been compared with the results of tests.

Distortional buckling performance of cold-formed steel lightweight concrete composite columns

  • Yanchun Li;Aihong Han;Ruibo Li;Jihao Chen;Yanfen Xie;Jiaojiao Chen
    • Steel and Composite Structures
    • /
    • v.50 no.6
    • /
    • pp.675-688
    • /
    • 2024
  • Cold-formed steel (CFS) is prone to buckling failure under loading. Lightweight concrete (LC) made of lightweight aggregate has light weight and excellent thermal insulation performance. However, concrete is brittle in nature which is why different materials have been used to improve this inherent behavior of concrete. The distortional buckling (DB) performance of cold-formed steel-lightweight concrete (CFS-LC) composite columns was investigated in this paper. Firstly, the compressive strength test of foam concrete (FC) and ceramsite concrete (CC) was carried out. The performance of the CFS-LC members was investigated. The test results indicated that the concrete-filled can effectively control the DB of the members. Secondly, finite element (FE) models of each test specimen were developed and validated with the experimental tests followed by extensive parametric studies using numerical analysis based on the validated FE models. The results show that the thickness of the steel and the strength of the concrete-filled were the main factors on the DB and bearing capacity of the members. Finally, the bearing capacity of the test specimens was calculated by using current codes. The results showed that the design results of the AIJ-1997 specification were closer to the experimental and FE values, while other results of specifications were conservative.