• 제목/요약/키워드: load-balanced

검색결과 259건 처리시간 0.022초

Behaviour Analysis of Self Excited Induction Generator Feeding Linear and No Linear Loads

  • Moulahoum, Samir;Kabache, Nadir
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1371-1379
    • /
    • 2013
  • Application of induction machines in wind turbine driven generators is a good alternative due to their good characteristics such as efficiency, reliability and low cost. Nevertheless, when isolated operation is required, the application of external capacitive bank, connected to the stator windings, to provide self-excitation results in a rather complex analysis. This paper presents an analysis of self-excited induction generator connected to a load either directly or by an intermediate of a power converter. At first a dynamic model of the induction generator accounting for magnetic saturation is developed. Then a number of balanced and unbalanced capacitors, passive and active loads are verified. Experimental results obtained from laboratory tests are compared to those simulated; the two are shown to be in good agreement.

판금형 해석을 위한 정적/외연적 유한요소 프로그램의 병령화에 관한 연구 (On The Parallel Inplementation of a Static/Explicit FEM Program for Sheet Metal Forming)

  • 진석기;정동원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.625-628
    • /
    • 1995
  • A static/implicit finite element code for sheet forming (ITAS3D) is parallelized on IBM SP 6000 multi-processor computer. Computing-load-balanced domain decomposition method and the direct solution method at each subdomain (and interface) equation are developed. The system of equations for each subdomain are constructed by condensation and calculated on each processor. Approximated operation counts are calculated to set up the nonlinear equation system for balancing the compute load on each subdomain. Th esquare cup tests with several numbers of elements are used in demonstrating the performance of this parallel implementation. This procedure are proved to be efficient for moderate number of processors, especially for large number of elements.

  • PDF

비선형 부하의 증감에 따른 고조파 특성 분석 (Analysis on the Harmonics Characteristics due to increase & decrease of Nonlinear load)

  • 김종겸;이운웅;김일중;김성헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.87-91
    • /
    • 2003
  • Most of the loads in industrial power distribution systems are balanced and connected to three wires power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating a large amount of non-characteristic harmonics. With the advent of power electronics and proliferation of non-linear loads in industrial power applications, power harmonics and their effects on power quality are a topic of concern. Harmonics by the unbalance voltage and non-linear loads, cause the increase of machine loss and heating. In order to allow current harmonic compensation, a filter must be installed. This paper describes the performance of passive filter under the voltage unbalance and non-linear load.

  • PDF

모드 해석을 이용한 등가 지진하중에서의 설계 편심 (Design Eccentricity in Equivalent Seismic Load Using Modal Analysis)

  • 조소훈;이명규
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.268-275
    • /
    • 2001
  • Modal analysis does well predict the elastic dynamic response of the torsionally unbalanced structure. But modal analysis overestimates the rotation of the structure in inelastic range, so one side members require ductility too much and the others require ductility too small in comparison with torsionally balanced structure. In this paper, in order to reduce difference of ductility demand between both side members of the torsionally unbalanced structure, design eccentricity of seismic load is evaluated and the method determining the strength center of structure is proposed using modal analysis. For several cases, the ductility demand of stucture is compared to investigate the propriety of the proposed approach.

  • PDF

Efficient Dual-layered Hierarchical Routing Scheme for Wireless Sensor Networks

  • Yoon, Mahn-Suk;Kim, Hyun-Sung;Lee, Sung-Woon
    • 한국산업정보학회:학술대회논문집
    • /
    • 한국산업정보학회 2008년도 추계 공동 국제학술대회
    • /
    • pp.507-511
    • /
    • 2008
  • Supporting energy efficiency and load balancing in wireless sensor network is the most important issue in devising the hierarchical routing protocols. Recently, the dual layered clustering scheme with GPS was proposed for the supporting of load balancing for cluster heads but there would be many collided messages in the overlapped area between two layers. Thereby, the purpose of this paper is to reduce the collision rate in the overlapped layer by concisely distinguish them with the same number of nodes in them. For the layer partition, this paper uses an equation $x^2+ y^2{\le}(\frac{R}{\sqrt{2\pi}})^2$ to distinguish layers. By using it, the scheme could efficiently distinguish two layers and gets the balanced number of elements in them. Therefore, the proposed routing scheme could prolong the overall network life cycle about 10% compared to the previous two layered clustering scheme.

  • PDF

On the Merger of Korean Mid Front Vowels: Phonetic and Phonological Evidence

  • Eychenne, Julien;Jang, Tae-Yeoub
    • 말소리와 음성과학
    • /
    • 제7권2호
    • /
    • pp.119-129
    • /
    • 2015
  • This paper investigates the status of the merger between the mid front unrounded vowels ㅔ[e] and ㅐ[${\varepsilon}$] in contemporary Korean. Our analysis is based on a balanced corpus of production and perception data from young subjects from three dialectal areas (Seoul, Daegu and Gwangju). Except for expected gender differences, the production data display no difference in the realization of these vowels, in any of the dialects. The perception data, while mostly in line with the production results, show that Seoul females tend to better discriminate the two vowels in terms of perceived height: vowels with a lower F1 are more likely to be categorized as ㅔ by this group. We then investigate the possible causes of this merger: based on an empirical study of transcribed spoken Korean, we show that the pair of vowels ㅔ/ㅐ has a very low functional load. We argue that this factor, together with the phonetic similarity of the two vowels, may have been responsible for the observed merger.

전압 불평형에서 콘덴서와 리액터의 직렬 연결시의 콘덴서의 특성 분석 (A Study on Condenser Characteristics at the Series Connection of Condenser and Reactor Under Voltage Unbalance)

  • 김일중;김종겸;박영진;김성헌
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.325-329
    • /
    • 2010
  • Capacitor has been used principally for the power factor compensation long ago. However now it does as passive filter to reduce harmonics of nonlinear load with reactor. Most of the customer's low-voltage feeder has been designed with approximately balanced and connected at the 3 phase four wire system. But voltage and current unbalance is appeared by the mixing operation of single or three phase load etc. The addition of reactor at the condenser may rise its terminal voltage. Voltage and current values above rating can act on electrical stress on the condenser. In this paper, we calculated and measured that voltage, current and capacity of condenser are changed under the voltage balance. We conclude that magnitude and deviation of phase voltage act on major point of electrical stress.

불평형 전압 운전시의 역률보상용 커패시터 특성 연구 (A Study on the Characteristics for Power Capacitor under the Voltage Unbalance Operation)

  • 김일중;김종겸
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.36-40
    • /
    • 2008
  • Most of the low-voltage feeder are designed with approximately balanced and connected at the three phase four wire systems. However, Most of the power distribution systems' load which is composed of single or three phase are unbalanced by generating load unbalance. Unbalanced current will draw a highly unbalanced voltage. The power factor of an induction motor at rated operation is between 25 and 90%, depending on the size and speed of the motor. However, many induction motors operate below the nominal rating, resulting in poor power factor. This condition needs power factor improvement. Addition of power capacitor at the motor terminal may draw to stress due to voltage unbalance. This paper presents operation characteristics on steady states of a three-phase induction motor under unbalanced voltages with power capacitor. The existence of voltage unbalance have an effect on stress of power capacitor.

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Journal of Power Electronics
    • /
    • 제3권3호
    • /
    • pp.151-158
    • /
    • 2003
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other This may result in wiring failure of the neutral conductor and overloading of the distribution transformer In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system This remedies overloading and power loss of the system The experimental results on a prototype validate the proposed control approach.

온라인 무정전전원장치의 병렬운전 제어기술 (Parallel Operation Control Technique of On-line UPS System)

  • 조준석;강병희;고재석;최규하;김진홍;정석언
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.501-505
    • /
    • 2001
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between inverters on synchronous d-q reference frame.

  • PDF