• Title/Summary/Keyword: load variation

Search Result 2,091, Processing Time 0.033 seconds

Robust tracking controller design for a load variation (부하변화에 견실한 추적 제어기 설계)

  • 김광태;정구락;김재환;박원철;박래석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.629-632
    • /
    • 1991
  • Load Variation effects on the system driving performance. Therefore, this paper presents as a application example of Anti-windup method using general incremental form for a gun servo system of load variation involved. Also, this method can be easily implemented compared to gain scheduling technique.

  • PDF

Development of Vehicle Clutch Discs Cushion Variation Measurement Device Using a Variable Load Electric Press (하중 가변형 전동 프레스를 이용한 차량용 클러치 디스크 쿠션 변위량 측정 장치 개발)

  • Park, Seung-Gyu;Choi, Hae-Woon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.6
    • /
    • pp.64-69
    • /
    • 2016
  • Vehicle clutch measurement for disc cushion variation was developed for the production of high quality Dual clutch transmissions. The developed device is composed of load cells for load measurement and LVDT for measuring the distance variation measurement in cushion variation. The servo motor-driven electric press for flexible loads that was developed was controlled by a PC-based HMI system, LabVIEW, and the device was able to continuously record real time measurement data with the accuracies of ${\pm}0.1\;kgf$ load and ${\pm}5{\mu}m$ cushion amount, which is far above the requirements of commercial vehicle standards.

A Study on Effective Enhancement of Load Power Factor Using the Load Power Factor Sensitivity of Generation Cost

  • Lee Byung Ha;Kim Jung-Hoon
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.3
    • /
    • pp.252-259
    • /
    • 2005
  • Various problems such as increase of power loss and voltage instability may often occur in the case of low load power factor. The demand of reactive power increases continuously with the growth of active power and restructuring of electric power companies makes the comprehensive management of reactive power a troublesome problem, so that the systematic control of load power factor is required. In this paper, the load power factor sensitivity of generation cost is derived and it is used for effectively determining the locations of reactive power compensation devices and for enhancing the load power factor appropriately. In addition, voltage variation penalty cost is introduced and integrated costs including voltage variation penalty cost are used for determining the value of load power factor from the point of view of economic investment and voltage regulation. It is shown through application to a large-scale power system that the load power factor can be enhanced effectively using the load power factor sensitivity and the integrated cost.

Characteristics for Current and Power of Induction Motor by Load Variation (부하변동에 따른 유도전동기 전류와 전력 특성)

  • Kim, Jong-Gyeum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.82-87
    • /
    • 2011
  • Induction motor is most widely used as the driving power in the industrial site. Induction motor current is composed of two parts, magnetizing current and load current. Load current uses energy what is doing the work. Load current varies with load variance but magnetizing current is constant, regardless of load variation. Magnetizing current needs for establishing the rotating magnetic field of induction motor and lags behind the voltage. Generally capacitor is used for power-factor compensation of inductive load. Self-excitation occurs when the capacitive reactive current from the capacitor is greater than the magnetizing current of the induction motor. When this occurs, excessive voltages can result on the terminals of the motor. This excessive voltage can cause insulation degradation and ultimately result in motor insulation failure. In this paper, we analyzed that how the magnetizing current and condenser current is operating at the allowable limit by the load variation. Condenser current is below allowable limit of magnetizing current but magnetizing current is above allowable limit at the lower load operation condition.

A Study on the Improvement of the IM Speed Control Characteristics with Load Torque Variation (부하 변동에 대한 유도 전동기의 속도 제어 특성에 관한 연구)

  • 강문호;김남정;유기윤;박귀태;민경일
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1075-1083
    • /
    • 1994
  • In this paper, a study on the improvement of the IM speed response against load torque variation is presented. A VSCS(Variable Structure Control System) is proposed which gives the desired robustness against load torque variation using a new kind of time-varing switching plane. In order to eliminate the reaching phase of the states from one switching plane to another during variation, the switching plane is varied continuously. To verify the high dynamic performance of the proposed VSCS, simulation and experimental results are presented.

Load Modeling of the Drum Washing Machine Considering the Mechanical Characteristics (역학적 특성을 고려한 드럼세탁기 부하 모델링)

  • Lee, Jung-Hyo;Lee, Won-Chul;Yu, Jae-Sung;Jung, Yong-Chae;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.491-499
    • /
    • 2007
  • The variation of a load characteristic in the motor drive is one of the most important consideration. Because the current flowing into the motor generally varies according to the load variation, it needs to design the motor drive circuit properly in accordance with the load variation. However, the load variation of the drum washing machine is irregular and large due to the water flow and reverse load torque. Therefore, to design the motor drive circuit considering this load pattern, simulation results shows the load pattern modeling of the drum washing machine based on the physical analysis in this paper.

Fuzzy PI Speed Controller of Induction Motor Compensation the Variation of Load Inertia (부하관성모멘트 변화를 보상한 유도전동기의 퍼지 PI 속도제어)

  • Cho, Soon-Bong;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.2
    • /
    • pp.233-243
    • /
    • 1994
  • Generally, fuzzy PI controller that regulates the gains using fuzzy algorithm shows high performance in speed response. However, it has some problems to the load inertia variation, because the change of speed error(CE) is in a fixed range. As load inertia increases, CE is decreased and the usuage of fuzzy table is limited. Therefore, the output of the fuzzy controller has a limited range. This paper proposes an improved fuzzy PI controller. To reduce the speed overshoot, we adapt a control method that selects a proper CE range with respect to the load inertia variation. The proposed controller is applied to the vector controlled system with 2.2kW induction motor. Some simulation and experimental results are exhibited. With these results, we can easily find that proposed PI controller is more robust than the conventional fuzzy PI controller against the load inertia variation.

Load modeling for the drum washing machine system simulation (드럼세탁기 구동시스템 시뮬레이션을 위한 부하 모델링)

  • Lee, Jung-Hyo;Lee, Byoung-Kuk;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.412-414
    • /
    • 2007
  • In motor driving, one of the most important consideration is the load characteristic and variation. Generally, the motor drive should be made enough for the current by load variation, and it should be controlled by the load weight. However, the drum washing machine's load variation is irregular and large. Therefore, we want to make the motor drive that considering this load pattern, this paper describes the drum washing machine's load pattern modeling by the mathematical theory.

  • PDF

A Comparison of Operating Characteristics for Industrial Water Cooler with Variation of Control Methods (제어방식에 따른 산업용 수냉각기의 운전 특성 비교)

  • Baek, Seung-Moon
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.99-105
    • /
    • 2014
  • This paper presents a comparison of operating characteristics for industrial water cooler with variation control methods. The performance analysis regarding the characteristics of condensation capacity, evaporation capacity, compressor load, COP of an on-off type cooler, a hot gas-bypass control type cooler and an inverter control type cooler with respect to the system load is reviewed, respectively. The primary results are as following: the variation of required compressor load of an on-off type cooler with respect to load is 5%, that of hot gas-bypass type is 18% and 66% for an inverter control type cooler. As the result shows, an inverter control type yields relatively huge difference of required compressor load compared to other types of control system. In terms of partial load, COP of an inverter control type cooler presents the highest value, and is considered as the optimized type for the used of the system involving frequent partial load.

The 24 Hourly Load Forecasting of the Election Day Using the Load Variation Rate (부하변동율을 이용한 선거일의 24시간 수요예측)

  • Song, Kyung-Bin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1041-1045
    • /
    • 2010
  • Short-term electric load forecasting of power systems is essential for the power system stability and the efficient power system operation. An accurate load forecasting scheme improves the power system security and saves some economic losses in power system operations. Due to scarcity of the historical same type of holiday load data, most big electric load forecasting errors occur on load forecasting for the holidays. The fuzzy linear regression model has showed good accuracy for the load forecasting of the holidays. However, it is not good enough to forecast the load of the election day. The concept of the load variation rate for the load forecasting of the election day is introduced. The proposed algorithm shows its good accuracy in that the average percentage error for the short-term 24 hourly loads forecasting of the election days is 2.27%. The accuracy of the proposed 24 hourly loads forecasting of the election days is compared with the fuzzy linear regression method. The proposed method gives much better forecasting accuracy with overall average error of 2.27%, which improved about average error of 2% as compared to the fuzzy linear regression method.