• 제목/요약/키워드: load modelling

검색결과 395건 처리시간 0.029초

Centrifuge modelling of rock-socketed drilled shafts under uplift load

  • Park, Sunji;Kim, Jae-Hyun;Kim, Seok-Jung;Park, Jae-Hyun;Kwak, Ki-Seok;Kim, Dong-Soo
    • Geomechanics and Engineering
    • /
    • 제24권5호
    • /
    • pp.431-441
    • /
    • 2021
  • Rock-socketed drilled shafts are widely used to transfer the heavy loads from the superstructure especially in mountainous area. Extensive research has been done on the behavior of rock-socketed drilled shafts under compressive load. However, little attention has been paid to uplift behavior of drilled shaft in rock, which govern the overall behavior of the foundation system. In this paper, a series of centrifuge tests have been performed to investigate the uplift response of rock-socketed drilled shafts. The pull-out tests of drilled shafts installed in layered rocks having various strengths were conducted. The load-displacement response, axial load distributions in the shaft and the unit skin friction distribution under pull-out loads were investigated. The effects of the strength of rock socket on the initial stiffness, ultimate capacity and mobilization of friction of the foundation, were also examined. The results indicated that characteristics of rock-socket has a significant influence on the uplift behavior of drilled shaft. Most of the applied uplift load were carried by socketed rock when the drilled shaft was installed in the sand over rock layer, whereas substantial load was carried by both upper and lower rock layers when the drilled shaft was completely socketed into layered rock. The pattern of mobilized shaft friction and point where the maximum unit shaft friction occurred were also found to be affected by the socket condition surrounding the drilled shaft.

Numerical simulation of masonry shear panels with distinct element approach

  • Zhuge, Y.;Hunt, S.
    • Structural Engineering and Mechanics
    • /
    • 제15권4호
    • /
    • pp.477-493
    • /
    • 2003
  • Masonry is not a simple material, the influence of mortar joints as a plane of weakness is a significant feature and this makes the numerical modelling of masonry very difficult especially when dynamic (seismic) analysis is involved. In order to develop a simple numerical model for masonry under earthquake load, an analytical model based on Distinct Element Method (DEM) is being developed. At the first stage, the model is applied to simulate the in-plane shear behaviour of an unreinforced masonry wall with and without opening where the testing results are available for comparison. In DEM, a solid is represented as an assembly of discrete blocks. Joints are modelled as interface between distinct bodies. It is a dynamic process and specially designed to model the behaviour of discontinuities. The numerical solutions obtained from the distinct element analysis are validated by comparing the results with those obtained from existing experiments and finite element modelling.

Modelling of flange-stud-slab interactions and numerical study on bottom-flange-bolted composite-beam connections

  • Xiaoxiang Wang;Yujie Yu;Lizhong Jiang;Zhiwu Yu
    • Steel and Composite Structures
    • /
    • 제47권2호
    • /
    • pp.203-216
    • /
    • 2023
  • The composite beam connections often encountered fracture failure in the welded bottom flange joint, and a bottom flange bolted connection has been proposed to increase the deformation ability of the bottom flange joint. The seismic performance of the bottom flange bolted composite beam connection was suffered from both the composite action of concrete slab and the asymmetric load transfer mechanisms between top and bottom beam flange joints. Thus, this paper presents a comprehensive numerical study on the working mechanism of the bottom flange bolted composite beam connections. Three available modelling methods and a new modelling method on the flange-stud-slab interactions were compared. The efficient numerical modeling method was selected and then applied to the parametric study. The influence of the composite slab, the bottom flange bolts, the shear composite ratio and the web hole shape on the seismic performance of the bottom flange bolted composite beam connections were investigated. A hogging strength calculation method was then proposed based on numerical results.

기관실 시뮬레이터 제작을 위한 3상유도전동기의 실용적 모델링 설계 (A practical modelling design of 3 phase induction motors for configuring engine room simulators)

  • 최순만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권6호
    • /
    • pp.887-893
    • /
    • 2010
  • 기관실 시뮬레이터에서 3상유도전동기에 대한 모델링을 단순하게 처리하는 경우에는 왜곡된 특성에 의해 각종 전기 기계적 모의 성능 수준이 크게 저하된다. 한편, 전동기 특성을 1, 2차 측 파라미터로 구분하는 기존의 등가회로 방식들은 복잡한 실험을 거치거나 상세 기술 자료가 확보되지 않고는 현장 전동기에 대한 회로에서의 파라미터 값들을 확정하지 못한다는 점에서 정격제원 정도만 주어지는 기관실 시뮬레이터의 개발 작업 환경에서는 사용할 수가 없다. 이러한 문제의 해결을 위해 본 논문에서는 최소 파라미터에 의한 전원 직결의 2 회로정수 방식 등가회로를 제시하였으며 이로부터 정격제원에 의해 회로정수가 결정되기까지의 조건과 과정 및 관련 식들을 해석하였다. 또한 실제 전동기에 이를 적용하여 얻어지는 특성곡선들을 통해 임의의 전동기에 대한 근사특성과 실용성을 확인하였다.

Numerical modelling of stress and deflection behaviour for welded steel beam-column

  • Soy, Ugur
    • Steel and Composite Structures
    • /
    • 제12권3호
    • /
    • pp.249-260
    • /
    • 2012
  • In this study, stress and deflection behaviours of T-type welding joint applied to HE200M steel beam and column were investigated in finite element method (FEM) under different distributed loads. In the 3D-FEM modelling, glue option was used to contact between steel materials and weld nuggets. Geometrical model was designed as 3-dimensional solid in ANSYS software program. After that, homogeneous, linear and isotropic properties were used to design to materials of model. Solid-92 having 3-dimensional, 4 faced and 10-noded was selected as element type. In consequence of mesh operation, elements of 13285 and nodes of 28086 were occurred. Load distribution was applied to top surface of steel beam to determine behaviours of stress and deflection. As a result of FEM analysis applied with the loads of 55,000 N, 110,000 N and 220,000 N, maximum values were obtained as 116 N/$mm^2$, 232 N/$mm^2$ and 465 N/$mm^2$ for stress and obtainedas 1,083 mm, 2,166 mm and 4.332 mm for deflection, respectively. When modelling results and classical calculation values were compared, it was obtained difference of 10 % for stress values and 2.5% for deflection values.

모델링 오차와 파라미터변동을 고려한 상태 관측기 설계 (State Observer Design Considering Modelling Errors and Parameter Variations)

  • 김찬기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2078-2081
    • /
    • 1997
  • IP speed controller is used as a main controller and it makes the system low overshoot and easy controllability. Load torque is estimated by Kalman filter algorithm and parameter controller is used against a rotor inertia negative variations. Parameter Controller (PC) is equipped with a torque observer implemented by software of a digital signal Processor. PC is a parameter controller which selects a moment of inertia J in responding to a load torque to control the system response.

  • PDF

Grid Independent Photovoltaic Fuel-Cell Hybrid System: Design and Control Strategy

  • Islam Saiful;Belmans Ronnie
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권4호
    • /
    • pp.399-404
    • /
    • 2005
  • In this paper, a hybrid photovoltaic fuel-cell generation system employing an electrolyzer for hydrogen generation and battery for storage purpose is designed and simulated. The system is applicable for remote areas or isolated DC loads. Control strategy has been considered to achieve permanent power supply to the load via the photovoltaic/battery or the fuel cell based on the power available from the sun. MATLAB and SIMULINK have been used for the simulation work. A sensitivity analysis is conducted for various load level based on availability of solar radiation.

주퇴충격하중을 받는 궤도차량 구조물의 천이응력해석 (Transient stress analysis of tracked vehicle structures under recoil impact load)

  • 이영신;김용환;김영완;김동수;성낙훈
    • 오토저널
    • /
    • 제15권3호
    • /
    • pp.111-119
    • /
    • 1993
  • In this study, the transient impact structural stress analysis of tracked vehicle structures under recoil impact load is investigated. ANSYS, ABAQUS Code are used for modelling and analytical procedures. The highest maximum Tresca stress occurs on race ring portion and its stress level is (.sigma.$_{T}$)$_{max}$ =20-40kgf/m $m^{2}$. The second highest stress occurs on upper plate of chassis and down plate of turret. The maximum stress level increases with loading direction and elevation angle. The results from liner static load analysis are very much different with impact analysis. Therefore, the practical solutions of structures under impact load can be obtained by only nonlinear transient impact analysis. The impact stress analysis of the steel vehicle structures is conducted. The maximum stress level is less than (.sigma.$_T/)$_{max}$m $m^{2}$. So, the design concept of steel structures can be adapted for new alternatives.s.s.s..s.

  • PDF

각형 CFT 단주의 하중-변형도 관계 모델 (Modelling of Load-Strain Curves for CFT Stub Columns)

  • 강현식;유영찬;문태섭
    • 한국강구조학회 논문집
    • /
    • 제12권1호통권44호
    • /
    • pp.9-16
    • /
    • 2000
  • 본 연구는 중심 압축을 받는 각형 CFT 단주의 하중-변형도 관계를 추정하기 위한 재료의 응력도-변형도 관계 모델화에 관한 것이다. 수정된 모델은 미일공동연구 결과식 형태를 기본으로 하여 본 연구자가 수행했던 실험결과로 수정된 것이다. 궁극적인 목적은 콘크리트와 강관의 강도 변화에 따른 거동 특성을 평가하기 위한 기초 자료의 제공에 있다.

  • PDF

추진인버터 시험을 위한 실시간 부하 시뮬레이터에 관한 연구 (Study on Real-Time Load Simulator for Testing Propulsion Inverter Test)

  • 김길동;신정렬;이우동;한석윤;박기준
    • 한국철도학회논문집
    • /
    • 제7권1호
    • /
    • pp.1-8
    • /
    • 2004
  • A newly-built inverter has to undergo a series of stress tests in the final stage of production line. This can be achieved by connecting it to a dynamometer consisting of a three-phase machine joined by a rigid shaft to a DC load machine. The latter is controlled to create some specific load characteristic needed for the test. In this paper a test method is proposed, in which no mechanical equipment is needed. The suggested test stand consists only of a inverter to be tested and a simulator converter. Both devices are connected back-to-back on the AC-side via smoothing reactors. The simulator operates in real-time as an equivalent load circuit, so that the device under test will only notice the behaviour of a three-phase machine under consideration of the load. In oder to prove rightness of the suggested test method, the simulation and actural experiment carried out emulation for a 2.2kW induction motor.