• Title/Summary/Keyword: load following

Search Result 940, Processing Time 0.03 seconds

Correlation of Major Scan Findings and Esophageal Varices in Liver Cirrhosis (간경변증에 있어서의 주요 간주사 소견과 식도정맥류와의 상관성에 관하여)

  • Ahn, J.S.;Bahk, Y.W.;Lim, J.I.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.4 no.1
    • /
    • pp.37-42
    • /
    • 1970
  • In an endeavor to help understand some typical scan findings and portal hemodynamics in liver cirrhosis, several commonly occurring scan changes and esophageal varices as demonstrated by esophagram were correlated one another from quantitative and qualitative stand points. Clinical materials consisted of 34 patients with proven diagnosis of liver cirrhosis and esophageal varices. Liver scan was performed with colloidal 198-Au and the changes in the size and internal architecture of the liver, splenic uptake and splenomegaly were graded and scored by repeated double-blind readings. The variceal changes on esophagrams were also graded according to the classification of Shanks and Kerley following modification. Of 34 patients, 91% showed definite reduction in liver volume (shrinkage) constituting the most frequent scan change. The splenic uptake and splenomegaly were noted in 73.5 and 79.4%, respectively. The present study revealed no positive correlation between the graded scan findings including shrinkage of the liver, splenic uptake or splenomegaly and severity of variceal changes of the esophagus. Exceptionally, however, apparently paradoxical correlation was noted between the severity of mottlings and varices. Thus, in the majority (73.5%) of patients mottlings were either absent or mild. This interesting observation is in favor of the view held by Christie et al. who consider the mottlings to be not faithful expression of actual scarring of the cirrhotic liver. This also would indicate that variceal changes are to be the results of intrahepatic arteriovenous shunting of blood with hypervolemic load to the portal system rather than simple hypertension secondary to fibrosis and shrinkage.

  • PDF

Dynamic Simulation of the Water-steam System in Once-through Boilers - Sub-critical Power Boiler Case - (관류보일러 물-증기 계통의 동적 시뮬레이션 - 아임계 동력보일러 사례 -)

  • Kim, Seongil;Choi, Sangmin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.5
    • /
    • pp.353-363
    • /
    • 2017
  • The dynamics of a water-steam system in a once-through boiler was simulated based on the physics-based modeling approach, representing the system in response to large load change or scale disturbance simulations. The modeling considered the mass, energy conservation, and momentum equation in the water pipe and the focus was limited to the sub-critical pressure region. An evaporator tube modeling was validated against the reference data. A simplified boiler system consisting of economizer, evaporator, and superheater was constructed to match a 500 MW power boiler. The dynamic response of the system following a disturbance was discussed along with the quantitative response characteristics. The dynamic response of the boiler system was further evaluated by checking the case of an off-design point operation of the feedwater-to-fuel supply ratio. The results re-emphasized the significance of controlling the feedwater-to-fuel supply ratio and additional design requirements of the water-steam separator and spray attemperator.

Late Cytomegalovirus Disease Causes Ileal Perforation after Kidney trasplantation (신 이식 후 소장 파열을 초래한 후기 cytomegalovirus 질환)

  • Lee, Hee-Woo;Hahn, Hye-Won;Park, Young-Seo
    • Childhood Kidney Diseases
    • /
    • v.15 no.1
    • /
    • pp.76-80
    • /
    • 2011
  • Cytomegalovirus (CMV) is the single most common infection following kidney transplantation and despite prophylactic strategies and the development of new antiviral agents, it still remains a cause of considerable morbidity and mortality. Current literature suggests that CMV infection may trigger rejection. We report a case of late CMV disease in a preemptive seropositive recipient who did not receive CMV prophylaxis. Diarrhea and abdominal cramping persisted after the administration of mycophenolate mofetil (MMF) six months after transplantation and resulted in ileal perforation at eight months after transplantation. The boy recovered after six weeks of treatment with ganciclovir. MMF has been mooted as a risk factor for CMV infection since its introduction, and further investigations are required to confirm its role. More attention to infectious complications is necessary and serial monitoring of viral load is recommended when MMF is administered.

A Study on the Fire Resistance of yLRC Composite Columns with Steel Sheet Forms and Angles (강재 영구거푸집을 사용한 yLRC 합성기둥의 내화성능 연구)

  • Kim, Bo Ram;Kang, Seong Deok;Kim, Hyung Geun;Kim, Myeong Han;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.3
    • /
    • pp.365-375
    • /
    • 2008
  • The main objective of this paper is to study the behaviour of yLRC composite columns at elevated temperatures by experimental test. The effects of load ratios, cross-section size and fire protection for the yLRC columns were investigate d by the test and compared using the heat transfer analysis perfo rmed based on the finite element program ANSYS 10.0 using the ISO834 standard fire curve, following the main guidelines proposed by the EC4 Part 1.2. As heat transfer is the movement of heat by conduction, convection, and radiation, and as temperature inside an object varies by position and time, time. As the steel's thermal conductivity is higher than that of concrete, steel loses its strength rapidly in a high-temperature situation such as a fire. Fire resistance performance of the yLRC composite column under fire conditions was evaluated througheat transfer analysis for parametric study.

Studies on the compound spun silk and its fabrics (복합견방사 및 그 제품개발에 관한 연구)

  • 남중희;송기언
    • Journal of Sericultural and Entomological Science
    • /
    • v.18 no.1
    • /
    • pp.27-39
    • /
    • 1976
  • In this study several kinds of spun silk yarn-synthetic filament compounded yarn was manufactured, and several fabrics woven from above mentioned silk compound yarn for evaluation of serviceability as clothing materials. The following results were obtained: 1. Degumming agents are in the order of sodium silicate, sodium hydroxide, sodium carbornate, soap and water. 2. When the concentration of sodium hydroxide is exceeded 3%, degradation of floss silk property is resulted because of excessive dissolving out of silk protein. 3. Degumming effect is much improved by concentration of degumming agent and less by its treating time. 4. Simultaneous application of more the 2 kinds of degumming agent is desirable for improvement of floss silk. 5. Application of natural organic acid brings very good results in keeping original scooping and color of the silk. 6. Load and elongation it increased by compound with synthetic filament yarn. 7. Even the evenness of compound yarn is largely dependent on the quality of floss silk and extent of degumming, the C.V.% of silk compound yarn in the experiment was 8-12%. 8. Single bath dyeing technique was impossible for their cloth, and dyeing was performed in 2 bath system separately for silk and synthetic fiber. 9. Shrinkage ratio due to the dyeing of fabric was 23% in case of polyester and spun silk fabric. 10. The final woven cloth can be applicable to (a) Blouse in care of thin cloth (compound silk fabric) (b) Korean costume for women in case of thick cloth. (compound hand spun silk fabric)

  • PDF

Evaluation of Mechanical Properties by Using Instrumented Indentation Testing for Resistance Spot Welds (비파괴 계장화 압입시험을 이용한 저항 점용접부 물성 평가)

  • Choi, Chul-Young;Kim, Jun-Ki;Hong, Jae-Keun;Yeom, Jong-Taek;Park, Yeong-Do
    • Journal of Powder Materials
    • /
    • v.18 no.1
    • /
    • pp.64-72
    • /
    • 2011
  • Nondestructive instrumented indentation test is the method to evaluate the mechanical properties by analyzing load - displacement curve when forming indentation on the surface of the specimen within hundreds of micro-indentation depth. Resistance spot welded samples are known to difficult to measure the local mechanical properties due to the combination of microstructural changes with heat input. Particularly, more difficulties arise to evaluate local mechanical properties of resistance spot welds because of having narrow HAZ, as well as dramatic changed in microstructure and hardness properties across the welds. In this study, evaluation of the local mechanical properties of resistance spot welds was carried out using the characterization of Instrumented Indentation testing. Resistance spot welding were performed for 590MPa DP (Dual Phase) steels and 780MPa TRIP (Transformation Induced Plasticity) steels following ISO 18278-2 condition. Mechanical properties of base metal using tensile test and Instrumented Indentation test showed similar results. Also it is possible to measure local mechanical properties of the center of fusion zone, edge of fusion zone, HAZ and base metal regions by using instrumented indentation test. Therefore, measurement of local mechanical properties using instrumented indentation test is efficient, reliable and relatively simple technique to evaluate the tensile strength, yield strength and hardening exponent.

Finite Element Analysis for Temperature Distribution Prediction of Steady Rolling Tires with Detailed Tread Pattern (패턴 형상을 고려한 회전하는 타이어의 온도 예측을 위한 유한 요소 해석)

  • Jeong, Kyoung Moon;Kang, Sung Ju;Park, Woo Cheol;Kim, Hyoung Seok;Kim, Kee Woon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.1
    • /
    • pp.117-125
    • /
    • 2014
  • The temperature distribution of steady state rolling tires with detailed tread blocks is numerically predicted using the three dimensional full patterned tire model. A three dimensional periodic patterned tire model is constructed by copying 1-sector mesh in the circumferential direction. Using the static tire contact analysis, the strain cycles during one revolution are approximated with the strains at Guassian points of the elements which are sector-wise repeated within the same circular ring of elements, by neglecting the tire rolling effect. Based upon the multi-axial fatigue theory, the maximum principal strain is used to represent the combined effect of six strain components on the hysteretic loss. In the following, the deformation due to the inflation and vertical load is calculated using ABAQUS. Then heat generation rate in each element is calculated using an in-house code. Lastly, temperature distribution is calculated using ABAQUS again. Through the numerical experiments, the validity of the proposed prediction method is examined by comparing with the experiment and the temperature distribution of a patterned tire model is compared with those of the main-grooved simple tire model.

A Study on The Non-Point Source Pollutant Load Routing Method (비점원 오염부하량 산정에 관한 연구)

  • Kim, Young-Seob;Lee, Gwan-Young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.11 no.1
    • /
    • pp.11-18
    • /
    • 2008
  • After execute quantitative analysis that choose station and compose floodgate quality of water net and use floodgate data and quality of water data analysis target Sign of the cock as 1 dimension access for Non-point pollution source pollution and estimate of Gaeuncheon's at Kyongsangbukdo report to the Throne in this research, presented parameter conclusion notation model (AGNPS) in real condition of our agricultural area through comparison with spot value and result is as following in reply. With result observation and analysis result of the AGNPS model the comparison which it will pay from the hazard which it analyzes 2005, the rainfall thought which is used in the analysis to select 8 heavy rain thoughts 2005 July - is data until of September. Actual amount of rainfall 6.0~195.0 mm one time the antecedent precipitation showed API5 case 0.0~507.0mm and were observed peak flows (Qpeak) each from the P-1 $0.026m^3/sec{\sim}9.265m^3/sec$, from the P-2 $0.010m^3/sec-2.747m^3/sec$ and from the P-3c $0.064m^3/sec-13.482m^3/sec$ to show. Also amendment AMC condition it will be cool and it uses and the AGNPS model conference the result which it occurs, analysis and regression analysis of actual flow for as 0.992 very the possibility of getting the result which is good there was a decisive coefficient which is cool. But the gun is (T-P) with the total nitrogen (T-N) decisive coefficient each as 0.794 and 0.849 the presumption which is reliability generally will pay and with the fact that it will be the possibility of getting it is judged.

  • PDF

Characteristics of Pollutant Loading into Streams from Flooded Paddies -On The Special Reference to Total Kjeldahl Nitorgen and Total phosphorous- (농경지로부터의 오염물질 유출부하특성 - 전Kjeldahl 질소 및 전인을 중심으로)

  • 홍성구;권순국
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.31 no.3
    • /
    • pp.93-102
    • /
    • 1989
  • With an objective to provide basic information for the management and the prediction of eutrophication in lentic water Systems, total amount of Kjeldahl nitrogen(T-N) and phosphorous(T-P) from irrigated water and drained water from flooded paddies were investigated during the rice growing period of 1988. A 29.3 ha paddies near Jungnam-myun, HwaSung-gun, Gyungi Province, Korea was instrumented for measuring runoff and sampling irrigated water and drained water from paddies. The following conclusions may be drawn from the result of this study. 1.During 115 days of investigation, T-N load for paddies was 362.6kg and T-P 63.44kg.These would be converted to 12.4kg T-N/ha and 2.17kg T-P/ha, respectively. 2.The T-N and T-P loadings in different periods showed a significant difference. The 25% of T-N loading was drained soon after fertilization period and 60% was drained during the rainy season from July 5 to July 24. 3.Annual loadings from paddies could be calculated to 30kg T-N/ha/year and 52kg T-P/ha/year considering non-measurement periods. 4.After the rainy season, the nutrient loads from drained water showed much less than those from irrigated water, and it may be suggested that the paddies would act as a stabilization pond. 5.The average concentrations of nutrients at 0.9km downstream from investigated paddies were 2.02(T-N) mg/l and 0.52(T-P) mg/I, which were 1.82(T-N) mg/l and 0.056(T-P)mg/l lower than those of drained water from paddies.

  • PDF

Effect of lower limb's support type on pectoralis major and erector spinae muscle activity during flat bench press (플랫 벤치 프레스 동작 시 하지의 지지유형이 대흉근과 척추기립근의 근 활성에 미치는 영향)

  • Lee, Sengu-Young;Ryu, Jong-Wook;Kim, Jai-Jeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.940-947
    • /
    • 2018
  • The purpose of this study was to obtain data to support applied motions of bench press and to provide basic data for the efficient execution of the exercise by analyzing muscular activation through measuring electromyogram of pectoralis major and erector spinae when flat bench pressing with feet on the ground versus feet on the bench. For this study, 4 amateur bodybuilders and 2 health trainers were chosen as subjects. Surface electrodes were attached on the measuring muscles; pectoralis major and erector spinae. Motion phases were defined for the flat bench press and each subject, with a 10RM load, performed a set with feet on the ground and another set with feet on the bench. Data was analyzed in SPSS 20.0 and the following results were obtained. The placement of the feet did not affect the muscular activation of the pectoralis major during the flat bench press. however, the muscular activation of the erector spinae was different between the two positions.