• 제목/요약/키워드: load factor rating

검색결과 65건 처리시간 0.027초

The Performance of Large-diameter Bored Piles and Large-section Barrettes in Decomposed Geomaterials in Hong Kong

  • Ng Charles W.W.
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 추계 학술발표회
    • /
    • pp.334-408
    • /
    • 2006
  • In Hong Kong, large-diameter (${\ge}600mm$) bored piles and large-section excavated rectangular barrettes are commonly used to support tall buildings to resist both vertical and horizontal loads. These piles and barrettes penetrate through and may found in saprolitic soils and decomposed rocks. Generally, the design of these large bored piles and barrettes involves considerable amount of uncertainty and design parameters must usually be verified by field tests. In this paper, over 50 full-scale load tests on large-diameter bored piles and over 15 large-section of rectangular barrettes in Hong Kong are reviewed and interpreted critically, in particular the degree of mobilisation of side shear resistance using a mobilization rating (MR) factor and a displacement index (DI) for floating bored piles and barrettes and rock-socketed piles, respectively. The author was heavily involved with many of these load tests. The diameter of the bored piles tested ranges from 0.6m to 1.8m and the depth varies from 12m to 75m. Sizes of barrettes critically reviewed include $2.2m{\times}0.6m,\;2.2m{\times}0.8m,\;2.8m{\times}0.8m\;and\;2.8m{\times}1.0m$ (on plan) and the depth varies from 36m and 63m. Based on these field tests, a new failure load criterion for large-diameter bored piles and barrettes is developed and proposed. The side shear resistance of the bored piles and barrettes is quantitatively analyzed with respect to local displacements, standard penetration tests, unconfined compressive strength (UCS) for rock sockets and using the effective stress principle. In addition, the effects of construction including post-grouting, construction time, side scraping and excavation tools on side shear resistance are investigated and reported.

  • PDF

ALFD방법에 의한 연속합성판형교의 강도평가에 대한 연구 (A Study on the Strength Rating of Continuous Composite Plate Girder Bridges by ALFD)

  • 한상철;정경희
    • 한국강구조학회 논문집
    • /
    • 제11권2호통권39호
    • /
    • pp.213-222
    • /
    • 1999
  • ALFD방법은 연속합성판형교의 과재하중과 최대하중에 대한 강도검토에 있어서 실제적인 거동을 나타낼 수 있는 탄소성해석법이다. 주어진 하중으로 인한 최대 정, 부모멘트단면에서의 항복은 활하중이 통과한 후에 잔류하는 소성회전을 일으킨다. 또한 제조시의 잔류응력으로 인하여 이론적인 항복모멘트 이하에서도 소성변형을 일으킨다. 이러한 국부항복은 다음에 작용되는 과재하중하에서 탄성화되어 정의 자생모멘트를 유발한다. 본 연구에서는 지점과 최대 정모멘트 단면에서의 단위소성회전각으로 인한 자생모멘트를 공액보법과 3연모멘트법에 의하여 구하였고, 9개의 설계경간을 지점단면을 감소시켜가면서 본 연구에서 개발한 전산프로그램에 의하여 연속관계와 모멘트-비탄성회전각 실험곡선과 일치하는 자생모멘트를 구하였다. 또한 한국도로교시방서에 준하여 비조밀단면을 갖는 3경간 연속합성판형교의 평가를 수행하였다.

  • PDF

유니버셜모터 속도제어기의 고조파전류 특성에 관한 연구 (A Study on the Harmonic Current Characteristics of Universal Motro with Speed Controller)

  • 임홍우;박수강;백형래
    • 전력전자학회논문지
    • /
    • 제6권2호
    • /
    • pp.132-140
    • /
    • 2001
  • 유니버셜모터는 소형의 직류 직권전동기와 같은 기계적 구조를 가지며 교류.직류 전원을 양용할 수 있는 장점으로 동급의 일반전동기에 비해 높은 속도로 구동이 가능하므로 핸드드릴이나 진공청소기, 세탁기 등의 가정용 기기 등에 일반적으로 사용된다. 위상각제어기를 이용하여 모터로 입력되는 전압을 제어하는 방법은 간단한 구조 때문에 위상지연으로 인해 입력 역률 및 저차 고조파 전류특성이 좋지 않음에도 불구하고 널리 사용되고 있다. 브리지 정류기를 사용하여 교류 전원을 맥동하는 직류 전원으로 변환한 후 DC 초퍼로써 유니버셜모터에 입력되는 평균전압을 제어하는 방법은 제어기의 효율을 높일 수 있고 저차 고조파전류를 감소시킬 뿐만 아니라 저전력값에 대해서도 부하역률의 저하를 막을 수 있다. 본 논문에서는 기존의 제어기의 방법으로 저가의 위상각 제어기를 구서하고 EH한 저가의 마이크로 컨트롤러를 이용한 DC 초퍼시스템을 각각 구성하여 저차 고조파전류 특성을 비교 분석하였다.

  • PDF

EEG Fast Beta Sub-band Power and Frontal Alpha Asymmetry under Cognitive Stress

  • Sohn, Jin-Hun;Park, Mi-Kyung;Park, Ji-Yeon;Lee, Kyung-Hwa
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2001년도 춘계학술대회 논문집
    • /
    • pp.225-230
    • /
    • 2001
  • Intensity of background noise is a factor significantly affecting both subjective evaluation of experienced stress level and associated electroencephalographic (EEG) responses during mental load in noisy environments. In the study on 27 subjects we analyzed the influence of the background white noise (WN) intensity on psychophysiological responses during a word recognition test. Electrocortical activity were recorded during baseline resting state and 40 s long performance on 3 similar Korean word recognition tests with different intensities of background WN (55, 70 and 85 dB).. An important finding in terms of physiological reactivity was similarity of all physiological response profiles between 55 and 70dB WN, i.e., none of physiological variables differentiated the two conditions, while 85dB WN resulted in a significantly different profile of reactions (higher fast beta power in EEG spectra). This condition was characterized by highest subjective rating of experienced stress, had more fast beta activity and had tendency of right hemisphere dominance, emphasizing the role of brain lateralization in negative affect control.

Application of numerical models to evaluate wind uplift ratings of roofs: Part II

  • Baskaran, A.;Molleti, S.
    • Wind and Structures
    • /
    • 제8권3호
    • /
    • pp.213-233
    • /
    • 2005
  • Wind uplift rating of roofing systems is based on standardized test methods. Roof specimens are placed in an apparatus with a specified table size (length and width) then subjected to the required wind load cycle. Currently, there is no consensus on the table size to be used by these testing protocols in spite of the fact that the table size plays a significant role in wind uplift performance. Part I of this paper presented a study with the objective to investigate the impact of table size on the performance of roofing systems. To achieve this purpose, extensive numerical experiments using the finite element method have been conducted and benchmarked with results obtained from the experimental work. The present contribution is a continuation of the previous research and can be divided into two parts: (1) Undertake additional numerical simulations for wider membranes that were not addressed in the previous works. Due to the advancement in membrane technology, wider membranes are now available in the market and are used in commercial roofing practice as it reduces installation cost and (2) Formulate a logical step to combine and generalize over 400 numerical tests and experiments on various roofing configurations and develop correction factors such that it can be of practical use to determine the wind uplift resistance of roofs.

오차를 고려한 765kV 변압기 보호 계전 정정룰 고찰 (Investigation into Transformer Protective Relay Setting Rule Considering Error Ratio)

  • 배영준;이승재;최면송;강상희;김상태;최정이;정창현;유영식;조범섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.229-231
    • /
    • 2002
  • The digital current differential relaying scheme is widely used for primary protection of 765(kV) power transformer. The current differential relay pickup the internal fault at the threshold which is set at 30% of rating current. Margin of 30% include current transformer error 5%, relay error 5%, on load tap changer error 7% and margin factor 140% obtained from the field experience. In this paper transformer protection relay and relay setting rule of high voltage power system are discussed. And we verify the correctness of relay setting rule with current differential relay using Matlab simulation.

  • PDF

3상 4선식 저압 수용가의 전압 불평형률 측정 분석 (The Measurement & Analysis of Voltage Unbalance Factor at LV Customer of Three-Phase Four-Wire System)

  • 김종겸;박영진
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.91-99
    • /
    • 2004
  • 대부분의 저압 수용가는 단상 및 3상 부하를 동시에 공급할 수 있는 장점을 지닌 3상 4선식 배전시스템을 적용하고 있다. 이 시스템은 구조적인 간단함 때문에 종래의 단상 및 3상 부하를 분리하는 방식보다 편리하다. 그러나 고르지 못한 부하 불평형이나 낮은 전기품질은 출력저하나 손실과 같은 문제를 발생하고 있다. 본 논문에서는 실제현장에서 전압 및 전류 파형을 측정하여 국제적으로 허용되고 있는 전압불평형 기준과 비교 분석을 실시하였다.

Fundamental Output Voltage Enhancement of Half-Bridge Voltage Source Inverter with Low DC-link Capacitance

  • Elserougi, Ahmed;Massoud, Ahmed;Ahmed, Shehab
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.116-128
    • /
    • 2018
  • Conventionally, in order to reduce the ac components of the dc-link capacitors of the two-level Half-Bridge Voltage Source Inverter (HB-VSI), high dc-link capacitances are required. This necessitates the employment of short-lifetime and bulky electrolytic capacitors. In this paper, an analysis for the performance of low dc-link capacitances-based HB-VSI is presented to elucidate its ability to generate an enhanced fundamental output voltage magnitude without increasing the voltage rating of the involved switches. This feature is constrained by the load displacement factor. The introduced enhancement is due to the ac components of the capacitors' voltages. The presented approach can be employed for multi-phase systems through using multi single-phase HB-VSI(s). Mathematical analysis of the proposed approach is presented in this paper. To ensure a successful operation of the proposed approach, a closed loop current controller is examined. An expression for the critical dc-link capacitance, which is the lowest dc-link capacitance that can be employed for unipolar capacitors' voltages, is derived. Finally, simulation and experimental results are presented to validate the proposed claims.

고가교 경량화에 따른 성능개선 (Performance Improvement of Overpass Bridge by Weight Reduction)

  • 김성배;남상혁;김장호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.51-60
    • /
    • 2011
  • 본 연구에서는 환경적인 요인으로 인한 성능저하현상으로 내구성 저하가 예상되는 건대-구의간 고가교의 현재 상태를 분석하고 내구성 저하로 인한 내구연한의 감소를 막기 위하여 고가교 구조물의 경량화를 통한 성능개선을 수행하고자 한다. 경량화 작업은 콘크리트 방음벽을 경량재 방음벽으로, 도상을 자갈도상에서 콘크리트 도상으로, 마지막으로 트라프를 경량화 함으로써 고가교 전체의 경량화를 유도한다. 이러한 고가교 경량화에 따른 정적 및 동적 거동 변화와 성능개선 효과를 분석하고, PSC I 형교 구간의 내하율 증진에 의한 구조안전성을 확인한다. 경량화 결과 구조물의 처짐이 2.6mm가 감소하고 1.07MPa의 인장응력이 감소된 것으로 평가되어 대상 구조물의 구조성능이 효과적으로 개선되었음을 알 수 있다. 고유진동수도 경량화에 따라 약 30% 증가하여 진동이 감소하고 동적거동이 향상되었다. 또한, 해석 및 계측 결과를 근거로 하여 대상교량의 내하력을 평가한 결과, 경량화에 따라 내하율이 1.82에서 1.93으로 증가하여 경량화에 따른 성능개선 효과가 우수한 것으로 판명되었다.

허가차량 통행에 대한 교량의 안전성 평가를 위한 허가차량 분류 체계 개발 (Development of Permit Vehicle Classification System for Bridge Evaluation in Korea)

  • 유상선;김경현;백인열;김지현
    • 한국산학기술학회논문지
    • /
    • 제21권12호
    • /
    • pp.845-856
    • /
    • 2020
  • 이 연구에서는 분리불가능한 허가차량의 통행에 대한 교량의 안전성 평가 체계를 정립하여 제안하였다. 대상으로 하는 허가차량의 하중효과와 도로교설계기준(한계상태설계법)의 설계차량하중의 계수하중효과를 비교하여, 허가차량의 체계를 일상허가와 두 개의 특별허가로 분류하였다. 일상허가 및 특별허가 1에서는 일반차량과 동시 통행하도록 제안하였으며, 특별허가 2에서는 허가차량이 단독 통행하도록 제안하였다. 허가차량의 전후에 동시 통행하는 일반차량의 연행을 고려하기 위하여 도로교설계기준의 표준차로하중을 이용하여 허가 하중 모형을 제안하였다. 제안된 허가 하중 모형을 적용하여 공용중인 프리스트레스트빔교 및 강박스교의 구조해석을 수행하였으며, 도로교설계기준의 하중·저항계수를 이용하여 허가하중 및 설계차량하중의 내하율 계산을 수행하였다. 교량 거더의 휨 및 전단에 대한 내하율 검토 결과 모든 차량하중의 내하율이 크게 계산되어 통행 가능한 것으로 확인되었다. 허가하중 및 설계차량하중의 휨 및 전단에 대한 교량의 신뢰도해석을 수행하여 신뢰도관점에서 충분한 안전성을 확보하는지 여부를 확인하였다. 도로교설계기준의 하중·저항계수를 이용하여 허가하중에 대한 최소요구강도를 계산하였으며, 최소요구강도의 신뢰도해석을 수행하였다. 최소 요구강도의 신뢰도해석 결과 대부분의 허가차량에 대하여 도로교설계기준의 목표신뢰도지수를 확보하는 것으로 확인되었다.