• Title/Summary/Keyword: load effects

Search Result 3,945, Processing Time 0.035 seconds

Effect of Supercritical Carbon Dioxide on Physicochemical Properties and Microbial Reduction of Freeze-Dried Bovine Liver (초임계 이산화탄소 처리가 동결 건조된 소간의 이화학적 특성 및 미생물 저감화에 미치는 영향)

  • Kim, Hye-Min;Woo, Sung-Woon;Kim, Ah-Na;Heo, Ho-Jin;Chun, Ji-Yeon;Choi, Sung-Gil
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.12
    • /
    • pp.1847-1855
    • /
    • 2015
  • Supercritical carbon dioxide ($SC-CO_2$) treatment has been becoming an important method for substituting the use of organic solvents for samples extraction prior to analysis due to its low toxicity, ease of handling, low cost of disposal etc. Freeze-dried bovine liver was treated with $SC-CO_2$ under different pressures (200, 300, and 450 bar) in order to investigate effects on physicochemical properties and reduction of microbial load. The yield of lipid extraction from bovine liver by $SC-CO_2$ treatment increased with increasing pressure, with values of 84, 86, and 90% in response to 200, 300, and 450 bar, respectively. Results of high performance liquid chromatography analysis showed that vitamin A and coenzyme $Q_{10}$ ($CoQ_{10}$), which is soluble in lipid, were almost removed from bovine liver by $SC-CO_2$ treatment. Saturated fatty acids ratio of bovine liver decreased with increasing pressure, whereas polyunsaturated fatty acids increased with increasing pressure. Total content of amino acids in bovine liver treated by $SC-CO_2$ was less than that of the control sample without treatment. The number of aerobic bacteria in bovine liver, which was stored at $5^{\circ}C$ for 5 days and freeze-dried, decreased from 6.2 to 4.2 log CFU/g by $SC-CO_2$ treatment at 100 bar for 3 h. Interestingly, coliform bacteria were not found in the bovine liver sample by $SC-CO_2$ at 100 bar for 3 h under all storage conditions. This indicates that $SC-CO_2$ treatment can effectively reduce coliform bacteria in the food matrix even at low moisture. In conclusion, freeze-dried bovine liver by proper $SC-CO_2$ treatment may be used as a potential high protein source, with increasing microbial safety and stability of lipid oxidation.

Channel Changes and Effect of Flow Pulses on Hydraulic Geometry Downstream of the Hapcheon Dam (합천댐 하류 하천지형 변화 예측 및 흐름파가 수리기하 변화에 미치는 영향)

  • Shin, Young-Ho;Julien, Pierre Y.
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.7
    • /
    • pp.579-589
    • /
    • 2009
  • Hwang River in South Korea, has experienced channel adjustments due to dam construction. Hapcheon main dam and re-regulation dam. The reach below the re-regulation dam (45 km long) changed in flow regime, channel width, bed material distribution, vegetation expansion, and island formation after dam construction. The re-regulation dam dramatically reduced annual peak flow from 654.7 $m^3$/s to 126.3 $m^3$/s and trapped the annual 591 thousand $m^3$ of sediment load formerly delivered from the upper watershed since the completion of the dam in 1989. An analysis of a time series of aerial photographs taken in 1982, 1993, and 2004 showed that non-vegetated active channel width narrowed an average of 152 m (47% of 1982) and non-vegetated active channel area decreased an average of 6.6 km2 (44% of 1982) between 1982 and 2004, with most narrowing and decreasing occurring after dam construction. The effects of daily pulses of water from peak hydropower generation and sudden sluice gate operations are investigated downstream of Hapcheon Dam in South Korea. The study reach is 45 km long from the Hapcheon re-regulation Dam to the confluence with the Nakdong River. An analysis of a time series of aerial photographs taken in 1982, 1993, and 2004 showed that the non-vegetated active channel width narrowed an average of 152 m (47% reduction since 1982). The non-vegetated active channel area also decreased an average of 6.6 $km^2$ (44% reduction since 1982) between 1982 and 2004, with most changes occurring after dam construction. The average median bed material size increased from 1.07 mm in 1983 to 5.72 mm in 2003, and the bed slope of the reach decreased from 0.000943 in 1983 to 0.000847 in 2003. The riverbed vertical degradation is approximately 2.6 m for a distance of 20 km below the re-regulation dam. It is expected from the result of the unsteady sediment transport numerical model (GSTAR-1D) steady simulations that the thalweg elevation will reach a stable condition around 2020. The model also confirms the theoretical prediction that sediment transport rates from daily pulses and flood peaks are 21 % and 15 % higher than their respective averages.

Prediction of Concrete Temperature and Its Effects on Continuously Reinforcement Concrete Pavement Behavior at Early Ages (초기재령에서 연속철근콘크리트포장 거동에 콘크리트 온도의 영향과 예측)

  • Kim Dong-Ho;Choi Seong-Cheol;Won Moon-Cheol
    • International Journal of Highway Engineering
    • /
    • v.8 no.2 s.28
    • /
    • pp.55-62
    • /
    • 2006
  • Transverse cracks in continuously reinforced concrete pavement (CRCP) occur at early ages due to temperature and moisture variations. The width and spacing of transverse cracks have a significant effect on pavement performance such as load transfer efficiency and punchout development. Also, crack widths in CRCP depend on 'zero-stress temperature,' which is defined as a temperature where initial concrete stresses become zero, as well as drying shrinkage of concrete. For good long-term performance of CRCP, transverse cracks need to be kept tight. To keep the crack widths tight throughout the pavement life, zero-stress temperature must be as low as practically possible. Thus, temperature control at early ages is a key component In ensuring good CRCP performance. In this study, concrete temperatures were predicted using PavePro, a concrete temperature prediction program, for a CRCP construction project, and those values were compared with actual measured temperatures obtained from field testing. The cracks were also surveyed for 12 days after concrete placement. Findings from this study can be summarized as follows. First, the actual maximum temperatures are greater than the predicted maximum temperature in the ranges of 0.2 to 4.5$^{\circ}C$. For accurate temperature predictions, hydration properties of cementitious materials such as activation energy and adiabatic constants, should be evaluated and accurate values be obtained for use as input values. Second, within 24 hours of concrete placement, temperatures of concrete placed in the morning are higher than those placed in the afternoon, and the maximum concrete temperature occurred in the concrete placed at noon. Finally, from the 12 days of condition survey, it was noted that the rate of crack occurrence in the morning placed section was 25 percent greater than that in the afternoon placed section. Based on these findings, it is concluded that maximum concrete temperature has a significant effect on crack development, and boner concrete temperature control is needed to ensure adequate CRCP performance.

  • PDF

The effects of short-term application of calcium hydroxide on dentin fracture strength (단기간의 수산화 칼슘 적용이 상아질 파절강도에 미치는 영향)

  • Shin, Eun-Jung;Park, Yeong-Joon;Lee, Bin-Na;Jang, Ji-Hyun;Chang, Hoon-Sang;Hwang, In-Nam;Oh, Won-Mann;Hwang, Yun-Chan
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.425-430
    • /
    • 2011
  • Objectives: This in vitro study investigated whether short-term application of calcium hydroxide in the root canal system for 1 and 4 wk affects the fracture strength of human permanent teeth. Materials and Methods: Thirty two mature human single rooted mandibular premolars in similar size and dentin thickness without decay or restorations were hand and rotary instrumented and 16 teeth vertically packed with calcium hydroxide paste and sealed coronally with caviton to imitate the endodontic procedure and the other 16 teeth was left empty as a control group. The apicies of all the samples were sealed with resin, submerged in normal saline and put in a storage box at $37^{\circ}C$ to mimic the oral environment. After 1 and 4 wk, 8 samples out of 16 samples from each group were removed from the storage box and fracture strength test was performed. The maximum load required to fracture the samples was recorded and data were analysed statistically by the two way ANOVA test at 5% significance level. Results: The mean fracture strengths of two groups after 1 wk and 4 wk were similar. The intracanal placement of calcium hydroxide weakened the fracture strength of teeth by 8.2% after 4 wk: an average of 39.23 MPa for no treatment group and 36.01 MPa for CH group. However there was no statistically significant difference between experimental groups and between time intervals. Conclusions: These results suggest that short term calcium hydroxide application is available during endodontic treatment.

Study on Analysis of the Proper Ratio and the Effects of Low Impact Development Application to Sewage Treatment District (하수처리구역 내 LID 적용에 대한 적정비율 및 효과분석 연구)

  • Shin, Hyun Suk;Kim, Mi Eun;Kim, Jae Moon;Jang, Jong Kyung
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.12
    • /
    • pp.1193-1207
    • /
    • 2013
  • Increase of impervious area caused by overdevelopment has led to increase of runoff and then the problem of flooding and NPS were brought up. In addition, as decrease of base flow made groundwater level to decline, a stream that dries up is issued. low impact development (LID) method which is possible to mimic hydrological water cycle, minimize the effect of development, and improve water cycle structure is proposed as an alternative. As introduction of LID in domestic increases, the study on small watershed is in process mainly. Also, analysis of property of hydrological runoff and load on midsize watershed, like sewage treatment district, is required, the study on it is still insufficient. So, area applying LID practices from watershed of Dongrae stream is pinpointed and made the ratio and then expand it to watershed of Oncheon stream. Among low impact development practices, Green Roof, Porous Pavement, and Bio- retention are selected for the application considering domestic situations and simulated with SWMM-LID model of each watershed and improvement of water cycle and reduction of non-point pollution loads was analysed. Improvement of water cycle and reduction of non-point pollution loads were analyzed including the property of rainfall and soil over long term simulation. The model was executed according to scenario based on combination of LID as changing conductivity in accordance with soil type of the watershed. Also, this study evaluated area of LID application that meets the efficiency of conventional management as a criteria for area of LID practices applying to sewer treatment district by comparing the efficiency of LID application with that of conventional method.

Simultaneous Removal of Organic Pollutants, Nitrogen, and Phosphorus from Livestock Wastewater by Microbubble-Oxygen in a Single Reactor (단일반응기에서 마이크로버블-산소를 이용한 가축분뇨의 유기오염물질, 질소 및 인의 동시 제거)

  • Jang, Jae Kyung;Jin, Yu Jeong;Kang, Sukwon;Kim, Taeyoung;Paek, Yee;Sung, Je Hoon;Kim, Young Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.11
    • /
    • pp.599-606
    • /
    • 2017
  • The effects of microbubble-oxygen physicochemical method for the removal of organic pollutants, nitrogen, and phosphorus contained in animal manure were investigated using a laboratory scale single reactor. The characteristics of used livestock manure were $36,894{\pm}5,024mg\;TCOD/L$, $22,031{\pm}2,018mg\;SCOD/L$, $4,150{\pm}35mg\;NH_4-N/L$, and $659{\pm}113mg\;PO_4-P/L$. It was confirmed that the amount of organic pollutants, nitrogen, and phosphorus removal was increased by the use of oxygen rather than air as the gas supplied with the microbubble, and by input of larger oxygen amount. When the oxygen was fed with 600 mL flow rate per minute, TCOD and phosphorus removal were 2.5 times and 5.6 times higher than those of air supplied. As the microbubble-oxygen reaction time was longer, the removal rate of nutrients increased gradually. The removal rates of ammonium and phosphorus reach to $41.03{\pm}0.20%$ and $65.49{\pm}1.39%$, respectively, after 24 hours. When the coagulation treatment method was applied to increase phosphorus removal rate from the effluent of microbubble-oxygen treatment, the phosphorus was removed up to 92.7%. However, the removal rate of organic pollutants (TCOD) was as small as $28.7{\pm}0.2%$ within the first 6 hours, and then the negligible removal of TCOD was recorded. This study suggests that microbubble-oxygen can be applied not only livestock manure but also aeration tank of various wastewater treatment plant, which can reduce the load on the associated unit process and produce stable high-quality effluent.

Negative Support Reactions of the Single Span Twin-Steel Box Girder Curved Bridges with Skew Angles (단경간 2련 강박스 거더 곡선교의 사각에 따른 부반력 특성)

  • Park, Chang Min;Lee, Hyung Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.34-43
    • /
    • 2012
  • The behaviors of the curved bridges which has been constructed in the RAMP or Interchange are very complicate and different than orthogonal bridges according to the variations of radius of curvature, skew angle and spacing of shoes. Occasionally, the camber of girder and negative reactions can be occurred due to bending and torsional moment. In this study, the effects on the negative reaction in the curved bridge were investigated on the basis of design variables such as radius of curvature, skew angle, and spacing of shoes. For this study, the twin-steel box girder curved bridge with single span which is applicable for the RAMP bridges with span length(L) of 50.0m and width of 9.0m was chosen and the structural analysis to calculate the reactions was conducted using 3-dimensional equivalent grillage system. The value of negative reaction in curved bridges depends on the plan structures of bridges, the formations of structural systems, and the boundary conditions of bearing, so, radius of curvature, skew angle, and spacing of shoes among of design variables were chosen as the parameter and the load combination according to the design standard were considered. According to the results of numerical analysis, the negative reaction in curved bridge increased with an decrease of radius of curvature, skew angle, and spacing of shoes, respectively. Also, in case of skew angle of $60^{\circ}$ the negative reaction has been always occurred without regard to ${\theta}/B$, and in case of skew angle of $75^{\circ}$ the negative reaction hasn't been occurred in ${\theta}/B$ below 0.27 with the radius of curvature of 180m and in ${\theta}/B$ below 0.32 with the radius of curvature of 250m, and in case of skew angle of $90^{\circ}$ the negative reaction hasn't been occurred in the radius of curvature over 180m and in ${\theta}/B$ below 0.38 with the radius of curvature of 130m, The results from this study indicated that occurrence of negative reaction was related to design variables such as radius of curvature, skew angle, and spacing of shoes, and the problems with the stability including negative reaction will be expected to be solved as taken into consideration of the proper combinations of design variables in design of curved bridge.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

A Study of the Insulin and the C-Peptide Responses to Oral Glucose Load in Nondiabetic and Diabetic Subjects (정상인(正常人) 및 당뇨병환자(糖尿病患者)에서의 경구당부하시(經口糖負荷時) 혈중(血中) Insulin과 C-Peptide의 변동(變動))

  • Lee, Myung-Chul;Choi, Sung-Jae;Kim, Eung-Jin;Min, Hun-Ki;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.11 no.1
    • /
    • pp.17-32
    • /
    • 1977
  • The present study was undertaken to evaluate the significance of the insulin and the C-peptide rseponse to oral glucose loads in normal and diabetic subjects and to establish the effects of the obesity. In this study, the authors have measured plasma insulin and C-peptide by means of radioimmunoassay in 10 nonobese normal, 5 obese normal, 13 nonobese moderate diabetic patients, 9 obese moderate diabetic patients and 9 severe diabetic patients. The results obtained were as follows; 1. In 10 nonobese normal subjects, the plasma insulin level at fasting state and at 30, 60, 90, and 120 min after oral glucose loads were $15.7{\pm}3.4,\;48.3{\pm}9.8,\;40.4{\pm}6.7,\;37.4{\pm}6.5\;and\;26.0{\pm}4.2uU/ml(Mean{\pm}S.E.)$ and C-peptide were $1.9{\pm}0.3,\;3.9{\pm}0.6,\;6.3{\pm}0.6,\;5.7{\pm}0.5\;and\;4.0{\pm}0.5ng/ml$. The change of C-peptide was found to go almost parallel with that of insulin and the insulin value reaches to the highest level at 30 min whereas C-peptide reaches to its peak at 60min. 2. The plasma insulin level in 5 obese normal subjects were $38.9{\pm}12.3,\;59.5{\pm}12.3,\;59.2{\pm}17.1,\;56.1{\pm}20.0\;and\;48.4{\pm}17.2uU/ml$ and the C-peptide were $5.5{\pm}0.4,\;6.8{\pm}0.5,\;7.9{\pm}0.8,\;7.9{\pm}0.8\;and\;7.8{\pm}2.0ng/ml$. The insulin response appeared to be greater than nonobese normal subjects. 3. In 13 nonobese moderate diabetic patients, the plasma insulin levels were $27.1{\pm}4.9,\;44.1{\pm}6.0,\;37.3{\pm}6.6,\;35.5{\pm}8.1\;and\;34.7{\pm}10.7uU/ml$ and the C-peptide levels were $2.7{\pm}0.4,\;4.9{\pm}0.7,\;6.5{\pm}0.5,\;7.0{\pm}0.3\;and\;6.7{\pm}1.0ng/ml$. There was little significance compared to nonobese normal groups but delayed pattern is noted. 4. In 9 obese moderated diabetic patients, the plasma insulin levels were $22.1{\pm}7.9,\;80.0{\pm}19.3,\;108.0{\pm}27.0,\;62.0{\pm}17.6\;and\;55.5{\pm}10.1uU/ml$ and the C-peptide levels were $5.2{\pm}0.4,\;8.0{\pm}1.0,\;10.4{\pm}1.6,\;10.4{\pm}1.7\;and\;10.1{\pm}1.0ng/ml$ and its response was also greater than that of nonobese moderate diabetic patients. 5. The plasma insulin concentrations in 9 severe diabetic subjects were $8.0{\pm}3.8,\;12.1{\pm}3.5,\;16.8{\pm}4.6,\;19.6{\pm}5.2\;and\;15.0{\pm}5.0uU/ml$ and the C-peptide levels were $1.6{\pm}0.3,\;2.4{\pm}0.4,\;4.1{\pm}0.6,\;4.0{\pm}0.8\;and\;4.5{\pm}0.7ng/ml$ and the insulin and C-peptide responses were markedly reduced in severe diabetic groups. 6. There were-significant differences between each groups of patients on the magnitude of total insulin or C-peptide areas, the insulinogenic index and the C-peptide index.

  • PDF

Development of water quality and aquatic ecosystem model for Andong lake using SWAT-WET (SWAT-WET을 이용한 안동호의 수질 및 수생태계 모델 구축)

  • Woo, Soyoung;Kim, Yongwon;Kim, Wonjin;Kim, Sehoon;Kim, Seongjoon
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.9
    • /
    • pp.719-730
    • /
    • 2021
  • The objective of this study is to develop the water quality and aquatic ecosystem model for Andong lake using SWAT-WET (Soil and Water Assessment Tool-Water Ecosystem Tool) and to evaluate the applicability of WET. To quantify the pollutants load flowing into Andong lake, a watershed model of SWAT was constructed for Andong Dam basin (1,584 km2). The calibration results for Dam inflow and water quality loads (SS, T-N, T-P) were analyzed that average R2 was more than 0.76, 0.69, 0.84, and 0.60 respectively. The calibrated SWAT results of streamflow and nutrients concentration was used into WET input data. WET was calibrated and validated for water temperature, dissolved oxygen, and water quality concentration (T-N, T-P) of Andong lake. The WET calibrated results was analyzed that PBIAS was +19%, -13%, +4%, and +26.5% respectively and showed that it was simulated to a significant level compared with the observation data. The observed dry weight (gDW/m2) of zoobenthos was less than 0.5, but the average value of simulation was analyzed to be 0.8, which is because the WET model considers zoobenthos with a broader concept. Although accurate calibration is difficult due to the lack of observed data, SWAT-WET can analyze the effects of environmental change in the upstream watershed on the lake based on long-term simulation based on watershed model. Therefore, the results of this study can be used as basic data for managing the aquatic environment of Andong lake.