• Title/Summary/Keyword: load distribution factors

Search Result 286, Processing Time 0.024 seconds

Application of multi-objective genetic algorithm for waste load allocation in a river basin (오염부하량 할당에 있어서 다목적 유전알고리즘의 적용 방법에 관한 연구)

  • Cho, Jae-Heon
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.6
    • /
    • pp.713-724
    • /
    • 2013
  • In terms of waste load allocation, inequality of waste load discharge must be considered as well as economic aspects such as minimization of waste load abatement. The inequality of waste load discharge between areas was calculated with Gini coefficient and was included as one of the objective functions of the multi-objective waste load allocation. In the past, multi-objective functions were usually weighted and then transformed into a single objective optimization problem. Recently, however, due to the difficulties of applying weighting factors, multi-objective genetic algorithms (GA) that require only one execution for optimization is being developed. This study analyzes multi-objective waste load allocation using NSGA-II-aJG that applies Pareto-dominance theory and it's adaptation of jumping gene. A sensitivity analysis was conducted for the parameters that have significant influence on the solution of multi-objective GA such as population size, crossover probability, mutation probability, length of chromosome, jumping gene probability. Among the five aforementioned parameters, mutation probability turned out to be the most sensitive parameter towards the objective function of minimization of waste load abatement. Spacing and maximum spread are indexes that show the distribution and range of optimum solution, and these two values were the optimum or near optimal values for the selected parameter values to minimize waste load abatement.

The ATC Calculation Method with Thermal Constraints and Voltage Stability Constraints (열적용량과 전압안정도를 고려한 ATC 계산 방법에 관한 연구)

  • Gim, Jae-Hyeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.86-93
    • /
    • 2007
  • This paper proposes two fast calculation methods of ATC. These two methods evaluate ATC with thermal constraints(Thermal ATC) and ATC with voltage stability constraints(Voltage ATC) respectively. The ATC with thermal constraints was based on the linear incremental power flow to account for the line flow thermal loading effects when the n-1 security constraints were included. The ATC with voltage stability constraints used two-bus equivalents of the system to find the maximum load at a load bus before reaching the voltage stability problem. The methods were tested on the IEEE 30bus systems and the results obtained were compared with those found by some other methods.

An Application of the Maximum Principle to Distributive Electrical Circuits (분포정수를 갖는 전기회로에 대한 최대원리의 응용)

  • Yang, Heung-Suk
    • 전기의세계
    • /
    • v.18 no.6
    • /
    • pp.9-22
    • /
    • 1969
  • This thesis has suggested a method of applying the Maximum Principle of Pontryagin to the optimal control of distributive electrical networks. In general, electrical networks consist of branches, nodes, sources and loads. The effective values of steady state currents and voltages are independent of time but only expressed as the functions of position. Moreover, most of the node voltages and branch currents are not predetermined, that is, initially unknown, and their inherent loop characteristics satisfy only Kirchhoff's current and voltage laws. The Maximum Principle, however, needs the initial fixed values of all state variables for its standand way of application. In spite of this inconsistency this thesis has undertaken to suggest a new approach to the successful solution of the above mentioned networks by introducing scaling factors and a state variable change technique which transform the boundary-value unknown problem into the boundary-value partially fixed and partially free problem. For the examples of applying the method suggested, the control problems for minimizing copper quantity in a distribution line have been solved with voltage drop constraint imposed on. In the case of uniform load distribution it has been shown that the optimal wire diameter of the distribution line is reciprocally proportional to the root of distance. For the same load pattern as above the wire diameter giving the minimum copper loss in the distribution line has been shown to be reciprocally proportional to distance.

  • PDF

Transients Analysis for Parameters on Electrical Distribution System (배전시스템에서의 파라미터에 따른 과도현상 분석)

  • 김재철;오정환;임성정
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.3
    • /
    • pp.88-96
    • /
    • 1997
  • This paper analyzes the transients for parameters on electrical distribution system. We analyze the voltage sag and switching surge caused by reclosing and develope a distribution system model of multiground type using a practical data of 22.9(kV) distribution system. It is at customer that we analyze an affecting of reclosing through EMTP (Electromagnetic Transients Program) simulation, present transient phenomena on fault line and parallel line. Also. we analyze the various parameters affecting this phenomena in detail through parametric analysis. These factors include the fault location, load size, load power factor, capacitor bank size, and reclosing angle. And relation between these parameters and transient phenomena is presented.

  • PDF

Contributions to the Impaired Water Bodies by Hydrologic Conditions for the Management of Total Maximum Daily Loads (수질오염총량관리 목표수질 초과지역에 대한 유황별 초과기여도 분석)

  • Park, Jun Dae;Oh, Seung Young
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.574-581
    • /
    • 2012
  • It is important to analyze the status of water quality with relation to the stream flow to attain water quality goal more effectively in the unit watersheds for the management of Total Maximum Daily Loads (TMDLs). This study developed a flow duration-water quality distribution graph to figure out water quality appearances on the flow variation and analyzed contributions of water quality observations to the impaired water bodies quantitatively by hydrologic conditions. Factors relating to water quality variation can be analyzed more precisely and assessed on the base of quantified contributions. It is considered that this approach could be utilized to establish a more effective plan for the water quality improvement including the prioritization of pollution reduction options.

Probabilistic condition assessment of structures by multiple FE model identification considering measured data uncertainty

  • Kim, Hyun-Joong;Koh, Hyun-Moo
    • Smart Structures and Systems
    • /
    • v.15 no.3
    • /
    • pp.751-767
    • /
    • 2015
  • A new procedure is proposed for assessing probabilistic condition of structures considering effect of measured data uncertainty. In this procedure, multiple Finite Element (FE) models are identified by using weighting vectors that represent the uncertainty conditions of measured data. The distribution of structural parameters is analysed using a Principal Component Analysis (PCA) in relation to uncertainty conditions, and the identified models are classified into groups according to their similarity by using a K-means method. The condition of a structure is then assessed probabilistically using FE models in the classified groups, each of which represents specific uncertainty condition of measured data. Yeondae bridge, a steel-box girder expressway bridge in Korea, is used as an illustrative example. Probabilistic condition of the bridge is evaluated by the distribution of load rating factors obtained using multiple FE models. The numerical example shows that the proposed method can quantify uncertainty of measured data and subsequently evaluate efficiently the probabilistic condition of bridges.

A Numerical Study on Load Distribution Factors for Simplified Composite H-Beam Panel Bridges (강합성 초간편 H형강 교량의 하중분배계수에 관한 해석적 연구)

  • Park, Jong Sup;Kim, Jae Heung
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.3
    • /
    • pp.221-232
    • /
    • 2009
  • The load distribution factor (LDF) values of simplified composite H beam panel bridges (SCHPBs) that were subjected to one lane and two lane loads were investigated using three dimensional finite element analyses with the computer program ABAQUS (2007). This study considered some design parameters such as the slab thickness, the steel plate thickness, the span length, and the continuity of the SCHPBs in the development of new LDFs. The distribution values that were obtained from these analyses were compared with those from the AASHTO Standard, LRFD, and the equations presented by Tarhini and Frederick, Huo et al., Back and Shin, and Cai. The AASHTO Standard distribution factors for SCHPBs were found to be very conservative. Sometimes, the distribution values from the finite element analyses for interior girders were similar to the results of the AASHTO LRFD, whereas the values for exterior girders were conservative in most cases. The new distribution values that were presented in this study produced LDFs that are more conservative than those from the finite element method. For the simple application of the design to SCHPBs, bridge engineers can use 0.42 for the interior girder and 0.32 for the exterior girder. The proposed values improve the current design procedure for the LDF problem and increase SCHPB design efficiency.

A Study on the Manufacturing of a High-Efficiency Load Cell Using a Single Surface Design (단일면으로 디자인한 고성능 로드셀 제작에 관한 연구)

  • Lee, Jung-Hyun;Lee, Woo-Ram
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.6
    • /
    • pp.724-730
    • /
    • 2010
  • A load cell is a converter that generates voltage signals when a certain force is effected in a given direction. An essential measurement device for electronic scales that indicate weight by numbers. These load cells are being applied in various areas such as daily life, distribution, laboratory and industrial. Recently the study to manufacture load cells in a more simple method while increasing performance is being persisted. In this study based on the comparison of load cells manufactured through single surface processing using strain gauges. Those manufactured through dual surface processing using strain gauges. Ultimately persist a more simple method of load cell manufacturing while increasing its performance. The elements that were compared were linearity, hysteresis, creep and eccentricity which are short tenn performance factors. The conclusion was that single surface processing showed almost identical data as that of dual surface processing, and the load cell error rate(0.005%) also excess regulation. The manufacturing time was shortened while mass-production was possible. Which indicates a development in the weighing industry.

Characteristics of wind loads on roof cladding and fixings

  • Ginger, J.D.
    • Wind and Structures
    • /
    • v.4 no.1
    • /
    • pp.73-84
    • /
    • 2001
  • Analysis of pressures measured on the roof of the full-scale Texas Tech building and a 1/50 scale model of a typical house showed that the pressure fluctuations on cladding fastener and cladding-truss connection tributary areas have similar characteristics. The probability density functions of pressure fluctuations on these areas are negatively skewed from Gaussian, with pressure peak factors less than -5.5. The fluctuating pressure energy is mostly contained at full-scale frequencies of up to about 0.6 Hz. Pressure coefficients, $C_p$ and local pressure factors, $K_l$ given in the Australian wind load standard AS1170.2 are generally satisfactory, except for some small cladding fastener tributary areas near the edges.

A review of seismic design recommendations in Jordan

  • Saffarini, Hassan S.
    • Structural Engineering and Mechanics
    • /
    • v.9 no.3
    • /
    • pp.257-268
    • /
    • 2000
  • The seismic design recommendations of the Jordan Code for Loads and Forces (JC) are evaluated, based on comparisons with analytical studies and the Uniform Building Code. It was established that the overall safety ensured by the implementation of these recommendations is not consistent with the established seismic risk in Jordan and the intended objectives of the code. A new zoning map is proposed with effective peak ground acceleration values. The different period formulae of the code were studied and were found to grossly underestimate the fundamental period when compared with analytically derived values or other codes' formulae. Other factors including the dynamic, soil, importance and behavior factors are discussed. It was determined that the JC's lateral load distribution formulae clearly lead to smaller internal forces than both dynamic analysis and UBC loads, even when those loads are normalized to give the same base shear. The main reason for this is attributed to the limited allowance for a backlash force in the JC.