• 제목/요약/키워드: load distribution factor

검색결과 411건 처리시간 0.036초

Wind-excited stochastic vibration of long-span bridge considering wind field parameters during typhoon landfall

  • Ge, Yaojun;Zhao, Lin
    • Wind and Structures
    • /
    • 제19권4호
    • /
    • pp.421-441
    • /
    • 2014
  • With the assistance of typhoon field data at aerial elevation level observed by meteorological satellites and wind velocity and direction records nearby the ground gathered in Guangzhou Weather Station between 1985 and 2001, some key wind field parameters under typhoon climate in Guangzhou region were calibrated based on Monte-Carlo stochastic algorithm and Meng's typhoon numerical model. By using Peak Over Threshold method (POT) and Generalized Pareto Distribution (GPD), Wind field characteristics during typhoons for various return periods in several typical engineering fields were predicted, showing that some distribution rules in relation to gradient height of atmosphere boundary layer, power-law component of wind profile, gust factor and extreme wind velocity at 1-3s time interval are obviously different from corresponding items in Chinese wind load Codes. In order to evaluate the influence of typhoon field parameters on long-span flexible bridges, 1:100 reduced-scale wind field of type B terrain was reillustrated under typhoon and normal conditions utilizing passive turbulence generators in TJ-3 wind tunnel, and wind-induced performance tests of aero-elastic model of long-span Guangzhou Xinguang arch bridge were carried out as well. Furthermore, aerodynamic admittance function about lattice cross section in mid-span arch lib under the condition of higher turbulence intensity of typhoon field was identified via using high-frequency force-measured balance. Based on identified aerodynamic admittance expressions, Wind-induced stochastic vibration of Xinguang arch bridge under typhoon and normal climates was calculated and compared, considering structural geometrical non-linearity, stochastic wind attack angle effects, etc. Thus, the aerodynamic response characteristics under typhoon and normal conditions can be illustrated and checked, which are of satisfactory response results for different oncoming wind velocities with resemblance to those wind tunnel testing data under the two types of climate modes.

Finite element bending and buckling analysis of functionally graded carbon nanotubes-reinforced composite beam under arbitrary boundary conditions

  • Belarbi, Mohamed-Ouejdi;Salami, Sattar Jedari;Garg, Aman;Hirane, Hicham;Amine, Daikh Ahmed;Houari, Mohammed Sid Ahmed
    • Steel and Composite Structures
    • /
    • 제44권4호
    • /
    • pp.451-471
    • /
    • 2022
  • In the present paper, the static bending and buckling responses of functionally graded carbon nanotubes-reinforced composite (FG-CNTRC) beam under various boundary conditions are investigated within the framework of higher shear deformation theory. The significant feature of the proposed theory is that it provides an accurate parabolic distribution of transverse shear stress through the thickness satisfying the traction-free boundary conditions needless of any shear correction factor. Uniform (UD) and four graded distributions of CNTs which are FG-O, FG-X, FG- and FG-V are selected here for the analysis. The effective material properties of FG-CNTRC beams are estimated according to the rule of mixture. To model the FG-CNTRC beam realistically, an efficient Hermite-Lagrangian finite element formulation is successfully developed. The accuracy and efficiency of the present model are demonstrated by comparison with published benchmark results. Moreover, comprehensive numerical results are presented and discussed in detail to investigate the effects of CNTs volume fraction, distribution patterns of CNTs, boundary conditions, and length-to-thickness ratio on the bending and buckling responses of FG-CNTRC beam. Several new referential results are also reported for the first time which will serve as a benchmark for future studies in a similar direction. It is concluded that the FG-X-CNTRC beam is the strongest beam that carries the lowest central deflection and is followed by the UD, V, Λ, and FG-O-CNTRC beam. Besides, the critical buckling load belonging to the FG-X-CNTRC beam is the highest, followed by UD and FG-O.

K-EMS 계통해석 어플리케이션을 위한 공통 데이터 모델 구축 (Common Data Model for Network Analysis Applications of K-EMS)

  • 윤상윤;조윤성;이욱화;손진만;남영우;이진;김홍래;김병호;김선구;허성일;이효상;신만철;민경일;최영진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.75-76
    • /
    • 2008
  • 본 논문에서는 한국형 에너지 관리 시스템의 계통 해석용 프로그램을 위한 공통 데이터 모델의 구축에 대해 다루었다. 공통 데이터 모델이란 다양한 어플리케이션이 공유하여 사용할 수 있는 계통 모델의 데이터베이스를 가리키며 본 논문에서는 토폴로지 프로세서(topology processor, TP), 상태추정(state estimator, SE), 급전원 조류계산(dispatcher power flow, DPF), 휴전계획(outage scheduler, OS), 부하 분포계수(bus load distribution factor, BLDF), 송전 손실 민감도 계수(transmission loss sensitivity factor, TLSF) 등을 위한 공통 모델에 대해 다루었다. 공통 모델의 구축을 위해 각 어플리케이션에서 필요한 정보를 수집하여 전력계통의 토폴로지 구조과 계통 설비를 모델링 하였다. 최종적으로 계층적(hierarchy) 구조와 비계층적(non-hierarchy) 구조로 나뉘어진 직접(direct) 및 간접(indirect) 인덱스 코드를 사용하여 데이터로의 빠른 접근이 가능한 실시간 데이터베이스 형태를 제시하였다.

  • PDF

Continuous force excited bridge dynamic test and structural flexibility identification theory

  • Zhou, Liming;Zhang, Jian
    • Structural Engineering and Mechanics
    • /
    • 제71권4호
    • /
    • pp.391-405
    • /
    • 2019
  • Compared to the ambient vibration test mainly identifying the structural modal parameters, such as frequency, damping and mode shapes, the impact testing, which benefits from measuring both impacting forces and structural responses, has the merit to identify not only the structural modal parameters but also more detailed structural parameters, in particular flexibility. However, in traditional impact tests, an impacting hammer or artificial excitation device is employed, which restricts the efficiency of tests on various bridge structures. To resolve this problem, we propose a new method whereby a moving vehicle is taken as a continuous exciter and develop a corresponding flexibility identification theory, in which the continuous wheel forces induced by the moving vehicle is considered as structural input and the acceleration response of the bridge as the output, thus a structural flexibility matrix can be identified and then structural deflections of the bridge under arbitrary static loads can be predicted. The proposed method is more convenient, time-saving and cost-effective compared with traditional impact tests. However, because the proposed test produces a spatially continuous force while classical impact forces are spatially discrete, a new flexibility identification theory is required, and a novel structural identification method involving with equivalent load distribution, the enhanced Frequency Response Function (eFRFs) construction and modal scaling factor identification is proposed to make use of the continuous excitation force to identify the basic modal parameters as well as the structural flexibility. Laboratory and numerical examples are given, which validate the effectiveness of the proposed method. Furthermore, parametric analysis including road roughness, vehicle speed, vehicle weight, vehicle's stiffness and damping are conducted and the results obtained demonstrate that the developed method has strong robustness except that the relative error increases with the increase of measurement noise.

Shaking table test and horizontal torsional vibration response analysis of column-supported vertical silo group silo structure

  • Li, Xuesen;Ding, Yonggang;Xu, Qikeng
    • Advances in concrete construction
    • /
    • 제12권5호
    • /
    • pp.377-389
    • /
    • 2021
  • Reinforced concrete vertical silos are universal structures that store large amounts of granular materials. Due to the asymmetric structure, heavy load, uneven storage material distribution, and the difference between the storage volume and the storage material bulk density, the corresponding earthquake is very complicated. Some scholars have proposed the calculation method of horizontal forces on reinforced concrete vertical silos under the action of earthquakes. Without considering the effect of torsional effect, this article aims to reveal the expansion factor of the silo group considering the torsional effect through experiments. Through two-way seismic simulation shaking table tests on reinforced concrete column-supported group silo structures, the basic dynamic characteristics of the structure under earthquake are obtained. Taking into account the torsional response, the structure has three types of storage: empty, half and full. A comprehensive analysis of the internal force conditions under the material conditions shows that: the different positions of the group bin model are different, the side bin displacement produces a displacement difference, and a torsional effect occurs; as the mass of the material increases, the structure's natural vibration frequency decreases and the damping ratio Increase; it shows that the storage material plays a role in reducing energy consumption of the model structure, and the contribution value is related to the stiffness difference in different directions of the model itself, providing data reference for other researchers; analyzing and calculating the model stiffness and calculating the internal force of the earthquake. As the horizontal side shift increases in the later period, the torsional effect of the group silo increases, and the shear force at the bottom of the column increases. It is recommended to consider the effect of the torsional effect, and the increase factor of the torsional effect is about 1.15. It can provide a reference for the structural safety design of column-supported silos.

해저터널의 불연속체 연계해석 시 잠재적 이완영역 평가 방법의 타당성 연구 (A feasibility study on the estimation of a potential relaxed zone in the discontinuum coupled analysis of a subsea tunnel)

  • 유광호
    • 한국터널지하공간학회 논문집
    • /
    • 제11권2호
    • /
    • pp.141-150
    • /
    • 2009
  • 불연속면이 발달한 암반 내에서 해저터널을 시공할 경우 절리 내의 지하수 흐름이 터널 거동에 커다란 영향을 마치므로 안정성 평가 시 수리-역학적 연계해석이 필요하다. 실무에서는 일반적으로 암반이완하중을 고려하여 터널의 콘크리트 라이닝을 설계한다. 연속체 해석 시 잠재적 이완영역을 터널 주변의 국부안전율 분포를 이용하여 수치해석에 의해 산정하는 방법이 제안된 바 있다. 그러나 절리가 발달한 암반의 경우는 절리의 거동이 터널 전제 거동에 큰 영향을 미친다. 따라서 본 연구에서는 불연속 암반 내에 터널 굴착으로 인해 발생하는 잠재적 이완영역을 산정하는 방법을 제안하고 민감도 분석 및 연속제 해석 결과와 비교를 통해 제안된 방법의 타당성을 검증하였다.

60M급 쌍동형 카페리 구조의 유공판 좌굴강도 연구 (A Study on the Buckling Strength of Perforated Plates for 60M Twin-hull Car-ferry)

  • 서광철;오정모
    • 해양환경안전학회지
    • /
    • 제24권1호
    • /
    • pp.126-132
    • /
    • 2018
  • 본 연구에서는 쌍동형 카페리에 다수 존재하는 유공판의 좌굴강도 설계 수행 결과 및 개선사항을 논의하고 있다. 카페리와 같이 길이가 50미터 이상이고, 길이/폭의 비가 12보다 큰 중/소형 고속선박은 상대적으로 두께가 얇고 연강을 사용함으로서 좌굴강도가 취약해질 가능성이 농후하다. 특히, 작업자의 접근 및 통로로 활용되는 유공판에서 좌굴강도가 취약해질 가능성이 있다. 안전한 구조설계를 위해서는 유공주위의 면내 하중 재 분포에 의한 좌굴강도 및 최종강도에 대한 명확한 검토가 필요하다. 본 연구에서는 유공판의 좌굴 및 최종강도 특성에 영향을 미치는 매개변수의 영향을 종합적으로 고려하기 위하여 유한요소해석 프로그램인 ANSYS를 활용한 비선형시리즈 해석을 수행하였으며, 주요 변수(종횡비, 유공비, 유공형상)들에 대한 영향을 검토하였다. 이 결과를 바탕으로 하여, 유공판의 좌굴강도를 결정짓는 가장 큰 인자는 유공비였으며, 종횡비와 유공의 형상은 그 영향이 미비하였다.

변연골 흡수가 내측연결 임플란트 매식체의 응력분포에 미치는 영향 (Three-dimensional finite element analysis for influence of marginal bone resorption on stress distribution in internal conical joint type implant fixture)

  • 윤미정;윤민철;엄태관;허중보;정창모
    • 대한치과보철학회지
    • /
    • 제50권2호
    • /
    • pp.99-105
    • /
    • 2012
  • 연구 목적: 지금까지 성공적인 임플란트 치료를 위해 많은 연구가 진행되어 왔으며, 임플란트 주변 골 흡수 현상에 대한 연구는 매우 관심이 높은 분야 중 하나이다. 이에 본 연구에서는 삼차원 유한요소응력분석을 이용하여 변연골 흡수가 내측연결 임플란트 매식체의 기계적 안정성에 미치는 영향을 간접적으로 확인하고자 하였다. 연구 재료 및 방법: 악골에 식립된 내측연결 형태의 임플란트 매식체에 티타늄 소재의 임플란트 지대주를 지대주 나사로 연결하고 상부에 금합금관을 장착하는 삼차원 유한요소모형을 설계하였다. 0, 1, 2, 3 mm의 변연골 흡수 상태를 적용하고, 교합면 중심에서부터 3 mm 편측에 300 N의 수직 하중을 가하여 임플란트 매식체에 발생하는 최대 주 응력을 계산하였다. 결과: 유한요소분석결과 변연골 흡수에 따른 임플란트 매식체의 최대 주응력 분포는 유사한 양상을 보였으며, 임플란트 매식체 상단에서 가장 높은 응력 집중이 나타났다. 최대 주응력은 처음 1 mm 변연골 흡수를 가정하였을 때 가장 크게 증가하였고, 이후 변연골 흡수가 증가할수록 응력은 증가하였지만 응력 증가의 폭은 감소하는 경향을 보였다. 결론: 이러한 결과로부터 내측연결 임플란트에서 매식체 두께가 얇은 경부의 노출은 변연골 흡수로 인한 응력 증가에 가장 큰 원인임을 알 수 있었으며, 매식체의 변형, 균열 및 파절 등의 기계적 실패를 감소시키기 위해서는 이에 대한 외과적, 보철적 고려가 필요할 것으로 생각된다.

풍화토 지반에 근입된 현장타설말뚝의 Cyclic p-y 곡선의 감소계수 제안 (Proposed Reduction Factor of Cyclic p-y Curves for Drilled Shafts in Weathered Soil)

  • 김병철;정상섬;고준영
    • 한국지반공학회논문집
    • /
    • 제31권2호
    • /
    • pp.47-63
    • /
    • 2015
  • 본 연구에서는 풍화토에 근입된 현장타설말뚝을 대상으로 수평 반복하중에 대한 말뚝-지반의 상호거동을 파악하기 위하여 현장타설말뚝 재하시험 및 3차원 유한요소 해석을 수행하였다. 현장재하시험은 국내에 널리 분포하고 있는 풍화토 지반에 근입된 현장타설말뚝을 재하시험 대상으로 하였다. 반복하중의 방향을 달리하여 일방향과 양방향으로 반복하중을 재하 하였으며, 반복하중의 방향에 따른 시험말뚝의 수평변위 및 휨모멘트를 분석하였다. 또한, 지반 물성이 말뚝-지반의 상호거동에 미치는 영향과 반복하중의 횟수, 방향 등, 하중특성 인자들의 영향 정도를 살펴보기 위하여 3차원 유한요소 모델링 및 해석을 수행하였으며, 국내 외에서 수행된 현장재하시험의 사례들 및 기존에 제안된 경험적 반복하중 p-y 곡선 함수들과 비교 분석함으로서 3차원 유한요소 모델링의 타당성을 확인하였다. 3차원 유한요소해석 결과, 풍화토에 근입된 현장타설말뚝에 작용하는 반복하중의 방향성을 고려할 수 있는 쌍곡선 형태의 p-y 곡선 함수식을 제안하였다. 또한 쌍곡선 형태의 정적하중 p-y 곡선 함수식에 반복하중에 의한 지반반력계수와 지반의 극한저항력의 감소 효과를 동시에 고려할 수 있는 감소계수를 도출하여, 말뚝의 변위와 지반의 극한 저항력의 관계를 하나의 함수식으로 표현하였다. 사질토에 근입된 말뚝의 반복하중 재하시험 사례들을 이용하여 결과를 비교 분석한 결과, 제안된 p-y 곡선 함수는 현장 실측치와 비교적 잘 일치하였으며, 기존의 경험적 반복하중 p-y 곡선 함수보다 말뚝-지반의 수평거동 특성을 더 적절히 예측함을 알 수 있었다.

역류식 충전탑에서 Raschig Super-ring Random Packing의 수력학적 특성에 대한 연구 (A Study on the Hydraulic Characteristics of Rashig Super-Ring Random Packing in a Counter-Current Packed Tower)

  • 강성진;임동하
    • 청정기술
    • /
    • 제26권2호
    • /
    • pp.102-108
    • /
    • 2020
  • 오늘날 석유화학, 정밀화학, 대기오염 방지산업 등에서 증류, 흡수, 추출, 탈거 등 물질분리 단위공정으로 주로 충전탑을 사용해 왔다. 충전탑은 가스-액체, 가스-가스 시스템에서의 물질들과의 접촉에 의해 운전되어 진다. 이러한 충전탑은 낮은 압력손실, 경제적 효율, 고온성 액체물질 적용, 유지보수 용이, 유해가스 처리 등의 운영에서 장점들을 가진다. 충전탑의 성능은 충진물을 통해 가스와 액체를 고르게 분산함으로써 우수한 성능을 보이며, 이는 충전탑 설계에 있어 중요한 인자로 고려되어진다. 본 실험에서는 충진물에 대한 액체부하 및 가스용량인자에 따른 건조압력손실, 수력학적 압력손실, 액체함량 변화에 대한 기하학적 특성에 대하여 연구하였다. 결과로부터 설계인자와 운전조건 등의 유해가스 처리에 필요한 인자를 도출하였다. 임의 충진물인 raschig super-ring에 대한 건조압력손실을 측정한 결과, 가스용량인자가 증가할수록 일정하게 선형적으로 증가하였고, 가스용량인자가 0.630 ~ 3.448 kg-1/2 m-1/2 S-1에서 건조압력손실은 1.892 ~ 47.312 mmH2O m-1로 기존 산업현장에서 보편적으로 사용되는 35 mm pall-ring보다도 낮은 압력손실을 보였다. 그리고 raschig super-ring에 대한 수력학적 압력손실을 측정한 결과, 고유 액체부하에 대하여 가스용량인자가 증가할수록 압력손실도 함께 증가함을 확인하였고, 액체부하 변화에 따른 가스용량인자가 1.855 ~ 2.323 kg-1/2 m-1/2 S-1으로 20% 증가할 때, 압력손실은 약 17% 증가하는 것으로 나타났다. 마지막으로, 충진물 체적에 관한 액체함량은 가스용량인자에 의존된 액체부하 매개변수로서 액체부하 변화에 따른 가스용량인자 약 3.84 kg-1/2 m-1/2 S-1까지는 거의 일정한 액체함량을 보였으나, 그 이상에서는 급격하게 증가하였다.