• 제목/요약/키워드: load distribution factor

검색결과 411건 처리시간 0.027초

부하패턴을 이용한 손실계수 산정 방법 (The Method of Calculating the Distribution Loss Factor using the Load Current Pattern)

  • 최성훈;김준일;박용업
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.40-45
    • /
    • 2010
  • In order to establish the electric distribution system economically and operate efficiently, it becomes important to calculate energy losses of the system more accurately. This importance is not only related for the engineering of utilities' power network but also for the consumers' electric system. The Distribution Loss Factor (DLF) is the fundamental element of calculating the energy losses occurred through the electric system including the electric lines and equipments. Up to now, the DLF is calculated by empirical formulas using the correlation between the DLF itself and Load Factor. However, these methods have some limitations to reflect the various characteristics of the system and the load. In this regard, the novel method proposed here is developed to yield more accurate result of DLF which actively interacting with the characteristics and load patterns of the system. The improvement of accuracy is very significant according to the results of verification presented at the end of this paper.

캐리어의 핀홀 위치 오차에 따른 유성기어의 하중 분할 및 하중 분포 영향 분석 (Effect Analysis of Carrier Pinhole Position Error on the Load Sharing and Load Distribution of a Planet Gear)

  • 김정길;박영준;이근호;김영주;오주영;김재훈
    • 한국기계가공학회지
    • /
    • 제15권5호
    • /
    • pp.66-72
    • /
    • 2016
  • Gearboxes are mechanical components that transmit power by adjusting input and output speed and torque. Their design requirements include small size, light weight, and long lifespan. We have investigated the effects of carrier pinhole position error on the load sharing and load distribution characteristics of a planetary gear set with four planet gears. The simulation model for a simple planetary gear set was developed and verified by comparing analytical results with a putative model. Then, we derived the load sharing and load distribution characteristics under various pinhole position error conditions using the prototypical simulation model. The results showed that the mesh load factor and face load factor increased with the pinhole position error, which then influenced the safety factor for tooth bending strength and surface durability.

Analysis of the load distribution and contact safety factor of PTO gears of a 71 kW class agricultural tractor

  • Baek, Seung-Min;Kim, Wan-Soo;Kim, Yeon-Soo;Lee, Nam-Gyu;Kim, Nam-Hyeok;Kim, Yong-Joo
    • 농업과학연구
    • /
    • 제47권2호
    • /
    • pp.327-335
    • /
    • 2020
  • The purpose of this study was to analyze the load distribution and contact safety factor for the power take off (PTO) gear of a 71 kW class agricultural tractor. In this study, a simulation model of the PTO gear-train was developed using Romax DESGINER. The face load factor and contact safety factor were calculated using ISO 6336:2006. The simulation time was set at 2,736 hours considering the lifetime of the tractor, and the simulation was performed for each PTO gear stage at the engine rated power conditions. As a result of the simulation, the face load factors for the driving gear at the PTO 1st, 2nd and 3rd stages were 1.644, 1.632, and 1.341, respectively. The contact safety factors for the driving gear at the PTO 1st, 2nd and 3rd stages were 1.185, 1.216, and 1.458, respectively. As the PTO gear stage was increased, the face load factor decreased, and the contact safety factor increased. The load distributions for all the PTO gears were concentrated to the right of the tooth width. This causes stress concentrations and shortens the lifespan of the gears. Therefore, it is necessary to improve the face load factor and the contact safety factor with macro-geometry and micro-geometry.

부하 변동에 의한 전압불평형율의 특성 해석 (Analysis on the Characteristics of Voltage Unbalance Factor by Load Variations)

  • 김종겸;박영진;이은웅
    • 전기학회논문지P
    • /
    • 제54권1호
    • /
    • pp.47-53
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating voltage unbalance. Voltage unbalance factor is mainly affected by load system rather than stable power system. Unbalanced voltage will draw a highly unbalanced current. As a result, the three-phase currents may differ considerably, thus resulting in an increased temperature rise in the machine. This paper presents a scheme on the characteristics of voltage and current unbalance factor under the load variation at the three phase 4-wire system. Load unbalance factor is measured by the power quality measurement apparatus and compared by the current unbalance factor. Two methods are indicated similar results. The voltage unbalance factor of the three-phase 4-wire system is approved by the field measurement. Each phase has an impedance each other by the unbalanced operation pattern and give rise to voltage unbalance.

배전계통에 있어서 최적 손실산정 기법에 관한 연구 (A Study on the Optimal Method of Loss Calculation in Distribution System)

  • 김미영;노대석;황혜미;김광호;신성수;김재언
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권6호
    • /
    • pp.340-349
    • /
    • 2004
  • Recently, the needs and concerns for the power loss are increasing according to the energy conservation at the level of the national policies and power utilities's business strategies. Especially, the issue of the power loss is the main factor for the determining the electric pricing rates in the circumstances of the deregulation of electrical industry. However, because of the lacking of management for power loss load factors (LLF), it is difficult to make a calculation for the power loss and to make a decision for the electric rates. And loss factor(k-factor), which is a most important factor for calculation of the distribution power loss, has been used as a fixed value of 0.32 since the fiscal year 1973. Therefore, This study presents the statistical calculation methods of the loss factors classified by load types and seasons by using the practical data of 65 primary feeders which are selected by proper procedures. Based on the above the algorithms and methods, the optimal method of the distribution loss management classified by facilities such as primary feeders, distribution transformers and secondary feeders is presented. The simulation results show the effectiveness and usefulness of the proposed methods.

거더교에서의 윤하중분배에 대한 연석과 중앙분리대의 영향에 관한 연구 (Influence of Curbs and Median Strip on Wheel Load Distribution in Girder Bridges)

  • 오병환;임춘근;유영;김광수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.455-460
    • /
    • 2001
  • Generally, the contribution of curbs and median strip is not considered carefully in analysing and designing the girder bridges. There being curbs, the load given on interior girder relatively reduced and on exterior girder increased. Curbs and median strip reduce the load distribution factor by distributing the load given on girder fairly, In this paper, the Influence of curbs and median strip in wheel distribution through parameter study and lateral distribution test of PSC girder bridge was investigated. Finite-element analysis was performed with parameterizing the flexural rigidity of the girder, span length, girder spacing, median strip, curbs. The influence of curbs and median strip would increase with lowering rigidity of girder. In addition, curbs lower the load distribution factor of exterior and interior girders.

  • PDF

동적재하시험을 통한 PSC 거더교의 횡분배 측정 (Lateral Load Distribution Estimation of a PSC Girder Bridge from Dynamic Loading Test)

  • 김성완;정진환;김성도;박재봉;이명진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권3호
    • /
    • pp.60-68
    • /
    • 2017
  • 교량은 사회간접시설물의 핵심이 되는 도로의 주요 시설물이므로 공용기간 동안 안정성과 사용성이 확보될 수 있도록 건설되며, 교량의 안전성 확보를 위하여 현재 상태에서 건전성을 평가하는 것은 유지관리 업무에서 중요한 과제이다. 일반적으로 교량의 내하력 평가를 위해 차량재하시험을 통하여 횡분배율을 측정함으로써 교량의 중첩거동 및 대칭거동을 확인할 수 있다. 그러나 공용중인 교량의 횡분배율을 측정하기 위하여 정적재하시험을 수행하고 있으며 교통통제의 어려움이 있다. 따라서 본 연구에서는 동적재하시험 및 상시진동시험에서 측정된 교량의 변위응답 데이터를 경험적 모드분해기법을 이용하여 정적 성분의 변위를 추출하였다. 추출된 정적 성분의 변위를 이용하여 횡분배율을 추정하였으며, 정적재하시험에서 측정된 횡분배율과 비교하였다.

분산형전원이 도입된 배전계통의 손실산정기법에 관한 연구 (A Study on the Optimal Distribution toss Management Using toss factor in Power Distribution Systems)

  • 노대석
    • 한국산학기술학회논문지
    • /
    • 제6권3호
    • /
    • pp.231-240
    • /
    • 2005
  • 본 연구에서는 분산형전원이 연계된 배전계통에서 배전 손실을 설비별로 산정하는 알고리즘과 통계적인 방법에 의하여 배전손실 계수를 산정하는 알고리즘을 제시하여 배전 손실 관리의 정확도를 제고하는 방안을 마련하고자 한다. 먼저, 배전손실에 대한 개념을 정의하고 배전손실 산정시의 문제점에 대하여 분석하고, 배전손실 산정에서 가장 중요한 자료 추출 방법과 대상자료의 유효성 검증하는 방법을 제시한다. 그리고 통계적인 방법에 의한 부하특성계수를 산정하는 알고리즘을 제시하고, 배전손실 요소들간의 상호관계를 규명하며, 배전 설비별(고압배전선로, 배전용변압기, 저압배전선로) 손실계산 알고리즘을 개발한다.

  • PDF

선형 및 비선형 부하 사용시 전류 및 부하불평형률에 대한 연구 (A Study on the Current & Load Unbalance Factor in using Linear & Nonlinear Load)

  • 김종겸;김지명
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1291-1296
    • /
    • 2017
  • Single-phase and three-phase load can be used together in 3-phase 4-wire system. Single-phase and three-phase loads can be classified as linear loads without harmonics and nonlinear with harmonics. Single-phase linear loads are linear loads such as lamps and heat, and single-phase nonlinear loads are power converters such as rectifiers. It is recommended that the distribution of loads in the 3-phase, 4-wire distribution lines be evenly distributed within a certain range. However, harmonic currents generated in a nonlinear load flow on the neutral line and affect the phase current magnitude. The difference in the magnitude of the individual phase current due to the influence of the harmonic current present in the neutral line can produce a difference in current and load unbalance. In this study, current unbalance ratio and load unbalance ratio which can occur when a combination of linear and nonlinear loads are applied to 3-phase 4-wire distribution line are calculated.

전압, 전류 및 부하 불평형율에 대한 비교 연구 (The Comparison Study for Voltage, Current and Load Unbalance Factor)

  • 김종겸;박영진;이은웅
    • 전기학회논문지P
    • /
    • 제54권2호
    • /
    • pp.88-93
    • /
    • 2005
  • Most of the LV customer have been applied the distribution system of 3-phase four wire system because of its advantage of supplying both of 1-phase & 3-phase loads simultaneously. Due to its structural simplicity, it is more convenient for use rather than the conventional separated scheme. But uneven load distribution or unclean voltage quality has occurred various problems such as de-rating, losses increase and vibration, etc. In this paper, voltage, current and power waveform in the actual fields have measured and analyzed in relation with internationally allowable voltage unbalance limits and compared the current unbalance factor with the load unbalance factor.