• Title/Summary/Keyword: load coefficient

Search Result 1,580, Processing Time 0.02 seconds

A Study on the Evaluation of Probable Snowfall Depth in Korea (우리나라의 확률적설량 산정에 관한 연구)

  • Lee, Jae-Joon;Jung, Young-Hoon;Lee, Sang-Won
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.2 s.25
    • /
    • pp.53-63
    • /
    • 2007
  • This study is to evaluate the probable snowfall depth by the point frequency analysis and to draw the map of probable snowfall depth in Korea. The 14 probability distributions which has been widely used in hydrologic frequency analysis are applied to the annual maximum depth of snowfall data. The parameters of each probability distribution are estimated by method of moments, maximum likelihood method and method of probability weighted moments. The estimated parameters were checked by parameter validity conditions of each assumed probability distribution. Four tests that are $X^2-test$, Kolmogorov-Smirnov test, Cramer von Mises test and probability plot correlation coefficient test are used in this study to determine the goodness of fit of the distributions. Mostly the 2-parameter gamma distribution was determined as appropriate distribution for the annual maximum new snowfall depth. The probable snowfall depth were obtained from appropriate distribution for the selected return periods and the maps of probable snowfall depth were presented. It will be useful to specify the snowfall load for the design of agricultural facilities such as vinyl house and cattle shed.

Estimation of TOC Concentration using BOD, COD in Runoff from Paddy Fields (영농기간동안 논 유출수 BOD, COD 자료를 이용한 TOC 농도 추정)

  • Choi, Dongho;Jung, Jaewoon;Yoon, Kwangsik;Lee, Kyoungsook;Choi, Woojung;Lim, Sangsun;Park, Hana;Yim, Byungjin;Hwang, Taehee
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.813-818
    • /
    • 2012
  • BOD and COD are currently used for water quality indices, but adoption of TOC for TMDL (Total Maximum Daily Load) is being suggested. Estimation of TOC using existing BOD and COD data is very important to diagnosis water quality trend when TOC is used for water quality index of organic matter in the future. The relationships between BOD COD and TOC in runoff from paddy fields were investigated during 2008-2011. The observed mean concentration of EMCs (Event Mean Concentration) for BOD, COD, TOC were 3.87, 10.97, 7.26 mg/L respectively. The correlation coefficients between BOD-TOC and COD-TOC were 0.42, 0.73, respectively. The coefficient of determination of regression equation for BOD-TOC and COD-TOC were 0.18, 0.53 respectively. Even though, conversion of COD data to TOC seems to be rather reliable than that of BOD-TOC, further monitoring is recommended to ensure better interpretation of relationship among BOD, COD and TOC.

Prediction of Water Quality at the Inlet of Saemangeum Bay by using Non-point Sources Runoff Simulation in the Mankyeong River Watershed (만경강 유역의 비점오염물질 유출모의를 통한 새만금 만 유입부의 수질 예측)

  • Ryu, Bum-Soo;Lee, Chae-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.761-770
    • /
    • 2013
  • This study was carried out to forecast the flow rate and water quality at the inlet of the Saemangeum bay in Korea using the SWMM(Storm Water Management Model) and the WASP(Water Analysis Simulation Program), and to analyze the impacts of pollutant loading from non-point source on the water quality of the bay. The calibration and validation of flow rate and water quality were performed using those from two monitoring points in the Mankyeong river administrated by Korean Ministry of Environment as part of the national water quality monitoring network. When the river flow rate was calibrated and validated using the rainfall intensities during 2011-2012, $R^2$ (i.e., coefficient of determination) was ranged from 0.91 to 0.96. For water qualities, it was shown that $R^2$ of BOD(Biochemical Oxygen Demand) was ranged from 0.56 to 0.86, and $R^2$ of T-N(Total Nitrogen) was from 0.64 to 0.75, and $R^2$ of T-P(Total Phosphorus) was from 0.67 to 0.89. The integrated modeling system showed significant advances in the accuracy to estimate the water quality. Finally, further simulations showed that annual average flow of the river running into the bay was estimated to be $1.439{\times}10^9m^3/year$. The discharged load of BOD, T-N, and T-P into the bay were anticipated to be 618.7 ton/year, 331.5 ton/year, and 40.4 ton/year, respectively.

Wear Characteristics of SiC by Sintered Temperature and SiO2 Contents (소결온도 및 SiO2 첨가량에 따른 탄화규소의 마모 특성)

  • Park, Sung-Ho;Park, Won-Jo;Yoon, Han-Ki
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.11
    • /
    • pp.1003-1009
    • /
    • 2008
  • In this study, liquid phase sintered SiC (LPS-SiC) materials were made by hot pressing method. The particle size of nano-SiC powder was 30nm. Alumina ($Al_2O_3$), yttria ($Y_2O_3$) and silica ($SiO_2$) were used for sintering additives. To investigate effects of $SiO_2$, ratios of $SiO_2$ contents were changed by five kinds. Materials have been sintered for 1 hour at $1760^{\circ}C$, $1780^{\circ}C$ and $1800^{\circ}C$ under the pressure of 20MPa. The system of sintering additives which affects a property of sintering as well as the influence depending on compositions of sintering additives were investigated by measurement of density, mechanical properties such as flexural strength, vickers hardness and sliding wear resistance were investigated to make sure of the optimum condition which is about matrix of $SiC_f$/SiC composites. The abrasion test condition apply to load of 20N at 100RPM for 20min. Sintered density, flexural strength of fabricated LPS-SiC increased with increasing the sintering temperature. And in case of LPS-SiC with low $SiO_2$, sliding wear resistance has very excellent. Monolithic SiC $1800^{\circ}C$ sintering temperatures and 3wt% have excellent wear resistance.

Wear Properties of Nuclear Graphite IG-110 at Elevated Temperature (원자력용 흑연 IG-110 에 대한 고온 마모 특성 평가)

  • Wei, Dunkun;Kim, Jaehoon;Kim, Yeonwook
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.5
    • /
    • pp.469-474
    • /
    • 2014
  • The high temperature gas-cooled reactor (HTR-10) is designed to produce electricity and hydrogen. Graphite is used as reflector, support structures, and a moderator in reactor core; it has good resistance to neutron and is a suitable material at high temperatures. Friction is generated in the graphite structures for the core reflector, support structures, and moderator because of vibration from the HTR-10 fuel cycle flow. In this study, the wear characteristics of the isotropic graphite IG-110 used in HTR-10 were evaluated. The reciprocating wear test was carried out for graphite against graphite. The effects of changes in the contact load and sliding speeds at room temperature and $400^{\circ}C$ on the coefficient of friction and specific wear rate were evaluated. The wear behavior of graphite IG-110 was evaluated based on the wear surfaces.

Humidity-Sensitive Characteristics and Reliabilities of Polymeric Humidity Sensors Using 2-Methacryloxyethyl dimethyl 2-hydroxyethyl ammonium brornide (2-Methacryloxyethyl dimethyl 2-hydroxyethyl ammonium bromide를 이용한 고분자 습도센서의 감습 특성 및 신뢰성)

  • Lee, Chil-Won;Gong, Myoung-Seon
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.461-466
    • /
    • 1999
  • The humidity sensor containing ammonium salt was prepared from the copolymer of 2-methacryloxyethyl dimethyl 2-hydroxyethyl ammonium bromide (MDHAB)/MMA/DAEMA = 6/3/1. The humid membrane was fabricated on the gold/alumina electrode by dipping. The impedances were $298k{\Omega},\;11k{\Omega}$, and $2.3k{\Omega}$ at 40%RH, 70%RH and 90%RH, respectively, at $5^{\circ}C$ and the humidity-sensitive characteristics were suitable for low temperature humidity sensor. The temperature-dependent coefficient between $5^{\circ}C$ and $20^{\circ}C$ was found to be $-0.80%RH/^{\circ}C$ and the hysteresis falled in the ${\pm}2%RH$ range. The response time was found to be 38 sec for the relative humidity ranging from 34%RH to 88%RH at $20^{\circ}C$. The reliabilities such as temperature cycle, humidity cycle, high temperature and humidity resistance, electrical load stability, stability of long-term storage and water durability were measured and evaluated for the application as a humidity sensor.

  • PDF

The Dynamic Performance Analysis of Foil Journal Bearings Considering Coulomb Friction: Rotating Unbalance Response (마찰을 고려한 포일저널베어링의 동특성해석: 회전불균형 응답)

  • Kim, Kyung-Woong;Lee, Dong-Hyun;Kim, Young-Cheol
    • Tribology and Lubricants
    • /
    • v.23 no.5
    • /
    • pp.219-227
    • /
    • 2007
  • The dynamic performance of air foil bearings relies on a coupling between a thin air film and an elastic foil structure. A number of successful analytical techniques to predict dynamic performance have been developed. However, the evaluation of its dynamic characteristic is still not enough because of the mechanical complexity of the foil structure and strong nonlinear behavior of friction force. This work presents a nonlinear transient analysis method to predict dynamic performance of foil bearings. In this method, time dependent Reynolds equation is used to calculate pressure distribution and a finite element method is used to model the bump foil structure. The analysis is treated with a direct implicit integration technique that can handle nonlinear problems and the stick-slip algorithm is used to consider friction force. Using this method the response to the mass unbalance excitation is investigated for various design parameters and operating conditions. The results of analysis show that foil bearing is very effective on the restriction of vibration at the resonance frequency compared to the rigid surface bearings and the effectiveness depends on the operating conditions, static load and a amount of mass unbalance. In addition, there exist optimum values of friction coefficient, bump foil stiffness and number of circumferential slit with regards to minimizing dynamic response at the resonance frequency. These optimum values are system dependent.

Effect of Surface Cover on the Reduction of NPS Pollution at a Vegetable Field (야채재배 밭에서 지표피복의 비점오염원 저감효과)

  • Shin, Minhwan;Jang, Jeongryeol;Won, Chulhee;Choi, Younghun;Shin, Jaeyoung;Lim, Kyoung Jae;Choi, Joongdae
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.436-443
    • /
    • 2012
  • This research was focused on the effect of rice straw and rice straw mat on the reduction of upland field non-point source (NPS) pollution discharges. Six experimental plots of $5{\times}22m$ in size and 3% in slope prepared on gravelly sandy loam soil were treated with control, rice straw cover and rice straw mat cover. Radish in Spring growing seasons were cultivated. NPS pollution discharge was monitored and compared with respect to the treatments. The surface cover rate of rice straw and rice straw mat right after the treatments was 64.7% and 73.7%, respectively. Rainfall of the 16 monitored events ranged from 12.8 mm to 538.2 mm. Runoff coefficient of the events was 0.01~0.67 in control plot, 0~0.63 in rice straw plot and 0~0.45 in rice straw mat plot. The reduction of runoff compared to the control plot was 5.4~99.7% in rice straw plot and 32.9~100% in rice straw mat plot. The reduction of NPS pollution load was 52.0% for SS, 28.5% for T-N and 35.2% for T-P in rice straw plot and 79.8% for SS, 68.3% for T-N and 53.3% for T-P in rice straw mat plot. This research revealed that rice straw mat cover on the soil surface could not only increase the crop yield and farmer's income but also reduce the NPS pollution loads significantly.

Determination of EMC and Unit Loading of Rainfall Runoff from Forestry-Crops Field (산림과 밭 지역 강우 유출수의 EMC 및 원단위 산정)

  • Won, Chul-hee;Choi, Yong-hun;Seo, Ji-yeon;Kim, Ki-cheol;Shin, Min-hwan;Choi, Joong-dae
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.615-623
    • /
    • 2009
  • The research of the determination of event mean concentration (EMC) was focussed combined sewer overflows and highway runoff in korea. But those of non-urban areas are few. In this study, EMC and unit loading on land use types in Nogok watershed were estimated by runoff loading of non-point source (NPS) on non-urban area. Two monitoring sites were equipped with an automatic velocity meter, flow meter, and water sampler. Monitoring was conducted at two monitering site during the rainy season. The results show that the EMC ranges in forest land use are 1.3~2.6 mg/L for BOD, 2.0~16.1 mg/L for SS, 0.1~2.1 mg/L for TN, and 0.12~0.49 mg/L for TP. The unit loading of NPS in this study was difficult to compare directly with that used conventionally because of the difference of field investigation. In near future, it needs to conduct more systematic and long-term research about NPS within the watershed. The results of this research can be used to estimate the total pollution load management system (TPLMS) program in korea.

The Joining Quality of High Strength Bolt, Nut and Washer Set (A490) in the Extreme Conditions (극한 상태에서 A490 고장력 볼트 세트의 체결 품질 연구)

  • Suk, Han-Gil;Cho, In-Seup;Hong, Hyeon-Sun
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.1
    • /
    • pp.21-25
    • /
    • 2011
  • This test focuses on the correlation between the lubrication, ductility and strength through the change of nut lubricant which decides joining angle for A490 bolt sets required in the AASHTO (American Association of State Highway & Transportation Officials). Because the lubrication of high tension bolt, nut, washer sets becomes an important factor to ductility and joining load, the quality improvement is required for improving reliability and securing enough lubrication of maker and user. This study examines the quality characteristics required in the specification through tests because only this standard specifies joining quality in the extreme conditions (as much about two times of the joining angle on site as normal condition). Moreover, this study is limited to the test on joining axial force required in the AASHTO for the three nut lubrication conditions of A490 bolt set. It is concluded that the nuts should be coated or waxed enough for the improvement of the joining axial force and ductility of bolts required in the standards. It is shown that in the case of plain high tension bolt sets, a rust preventing lubricative oil shall be applied and the torque coefficient value for A490 bolt sets should be maintained below 0.175.