• Title/Summary/Keyword: load and resistance factor

Search Result 297, Processing Time 0.033 seconds

Material Resistance Factors for Reinforced Concrete Flexural and Compression Members (철근콘크리트 휨부재 및 압축부재의 재료조항계수 적용에 관한 연구)

  • 김재홍;이재훈
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.2
    • /
    • pp.21-30
    • /
    • 2000
  • In the Ultimate Strength Design, the design strength of a member is determined by multiplying the strength reduction factor to the nominal strength. This concept may be a reasonable approach, however it can not consider failure modes appropriately. Moreover, column design strength diagram show an abrupt change at a low level of axial load, which does not seem to be reasonable. This research compares the design strength determined by the strength resistance factors. As the material resistance factors for flexure and compression, 0.65 and 0.90 are proposed for concrete and steel, respectively. The design strength calculation process by applying material resistance factors addresses failure modes more effectively than by applying member strength reduction factor, and provides more resnable design strength for reinforced concrete flexural and compression members.

A Electrical Characteristics of Disk-type Piezotransformer with Electrode Ratio of Driving and Generating Part (디스크형 압전변압기의 전극비에 따른 전기적 특성)

  • 이종필;채홍인;정수현;홍진웅
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.10
    • /
    • pp.458-463
    • /
    • 2003
  • In order to develope piezoelectric transformer for the ballast of fluorescent lamp, a new shape and electrode pattern of piezoelectric transformer has been investigated in this work. The composition of piezoelectric ceramics was 0.95Pb(Zr$_{0.51}$Ti$_{0.49}$)O$_3$+0.03Pb(Mn$_{1}$3/Nb$_{2}$3/)O$_3$+0.02Pb(Sb$_{1}$2/Nb$_{1}$2/)O$_3$. The sample prepared by this composition system showed the characteristics which has about 1200 of relative dielecric constant, 1100 of the mechanical quality factor, 0.53 of the electromechanical coupling coefficient, 320 pC/N of the piezoelectric constant d$_{33}$, 0.3 % of the dissipation factor. Diameter and thickness of disk-type piezoelectric transformer was 45 mm and 4 mm, respectively. The driving and generating electrode with their gap of 1mm were fabricated on the top surface. But the common electrode was fabricated on the whole bottom surface. The electrode surface ratio of driving and generating part on the top surface ranges from 1.4:1 to 3:1. We investigated the electrical characteristics with the variation of the electrode surface ratio of driving and generating part in the range of load resistance of 100 $\Omega$~70 k$\Omega$. The set-up voltage ratio of this piezoelectric transformer increases with increasing both the electrode surface of driving part and the load resistance. The set-up voltage ratio at no load resistance was more than 60 times. On the other hand, the efficiency decreases with increasing the electrode surface of driving part. In the case of the electrode surface of both 1.4:1 and 2:1, maximum efficiency showed above 97 % at load resistance of 2 k$\Omega$. However, in the case of the electrode surface of 3:1, maximum efficiency showed about 94 % at load resistance of 3 k$\Omega$.>.>.>.

Constructing Database and Probabilistic Analysis for Ultimate Bearing Capacity of Aggregate Pier (쇄석다짐말뚝의 극한지지력 데이터베이스 구축 및 통계학적 분석)

  • Park, Joon-Mo;Kim, Bum-Joo;Jang, Yeon-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.8
    • /
    • pp.25-37
    • /
    • 2014
  • In load and resistance factor design (LRFD) method, resistance factors are typically calibrated using resistance bias factors obtained from either only the data within ${\pm}2{\sigma}$ or the data except the tail values of an assumed probability distribution to increase the reliability of the database. However, the data selection approach has a shortcoming that any low-quality data inadvertently included in the database may not be removed. In this study, a data quality evaluation method, developed based on the quality of static load test results, the engineering characteristics of in-situ soil, and the dimension of aggregate piers, is proposed for use in constructing database. For the evaluation of the method, a total 65 static load test results collected from various literatures, including static load test reports, were analyzed. Depending on the quality of the database, the comparison between bias factors, coefficients of variation, and resistance factors showed that uncertainty in estimating bias factors can be reduced by using the proposed data quality evaluation method when constructing database.

A Study on the Comparisom of Load-carrying Capacity by the rating Methods of Bridges (교량평가법에 의한 내하력 비교에 관한 연구)

  • Han, Sang Chul;Yang, Seung Ie
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.5
    • /
    • pp.477-492
    • /
    • 2001
  • About half of bridges in United States are considered to be deficient and therefore are in need of repair or replacement. Half of these are functionally obsolete, and others do not have required strength For these bridges repairs and replacements are needed To avoid the high cost of rehabilitation the bridge rating must corectly report the present load-carrying capacity Rating engineers use Allowable Stress Design(ASD) Load Factor Design(LFD), and Load Resistance Factor Design(LRFD) to evaluate the bridge load carrying capacity In this paper the load rating methods are introduced and bridge load test data are collected. The reasons that make the difference between test results and analytical results are explained for each bridge load test And load rating methods are applied to real bridge. The rating factors from each method are compared.

  • PDF

Rating of steel bridges considering fatigue and corrosion

  • Lalthlamuana, R.;Talukdar, S.
    • Structural Engineering and Mechanics
    • /
    • v.47 no.5
    • /
    • pp.643-660
    • /
    • 2013
  • In the present work, the capacity ratings of steel truss bridges have been carried out incorporating dynamic effect of moving vehicles and its accumulating effect as fatigue. Further, corrosion in the steel members has been taken into account to examine the rating factor. Dynamic effect has been considered in the rating procedure making use of impact factors obtained from simulation studies as well as from codal guidelines. A steel truss bridge has been considered to illustrate the approach. Two levels of capacity ratings- the upper load level capacity rating (called operating rating) and the lower load level capacity rating (called inventory rating) were found out using Load and Resistance Factor Design (LRFD) method and a proposal has been made which incorporates fatigue in the rating formula. Random nature of corrosion on the steel member has been taken into account in the rating by considering reduced member strength. Partial safety factor for each truss member has been obtained from the fatigue reliability index considering random variables on the fatigue parameters, traffic growth rate and accumulated number of stress cycle using appropriate probability density function. The bridge has been modeled using Finite Element software. Regressions of rating factor versus vehicle gross weight have been obtained. Results show that rating factor decreases when the impact factor other than those in the codal provisions are considered. The consideration of fatigue and member corrosion gives a lower value of rating factor compared to those when both the effects are ignored. In addition to this, the study reveals that rating factor decreases when the vehicle gross weight is increased.

The Coefficients of Variation Characteristic of Stress Distribution in Silty Sand by Probabilistic Load (확률론적 하중에 따른 실트질 모래지반 내 지중응력의 변동계수 특성)

  • Bong, Tae-Ho;Son, Young-Hwan;Kim, Seong-Pil;Heo, Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.6
    • /
    • pp.77-87
    • /
    • 2012
  • Recently, Load and Resistance Factor Design (LRFD) based on reliability analysis has become a global trend for economical and rational design. In order to implement the LRFD, quantification of uncertainty for load and resistance should be done. The reliability of result relies on input variable, and therefore, it is important to obtain exact uncertainty properties of load and resistance. Since soil stress is the main reason causing the settlement or deformation of ground and load on the underground structure, it is essential to clarify the uncertainty of soil stress distribution for accurately predict the uncertainty of load in LRFD. In this study, laboratory model test on silty sand bed under probabilistic load is performed to observe propagation of upper load uncertainty. The results show that the coefficient of variation (COV) of soil stress are varied depending on location due to non-linear relationship between upper load increment and soil pressure increment. In addition, when the load uncertainty is transmitted through ground, COV is decreased by damping effect.

Study on the Variation of Reactive Power When Applying the Passive Filter (수동형 필터 적용시 무효전력의 변화에 관한 연구)

  • Kim, Ji-Myeong;Kim, Jong-Gyeum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1626-1631
    • /
    • 2016
  • Generally, the low-voltage customer has been used with a linear load and nonlinear load in the 3-phase 4-wire distribution system. Linear load has usually configured the resistance and inductance, current phase is slower than the voltage phase, so power factor is low. It is required for the power factor correction device prior to the phase of the current than the voltage. The capacitor is connected in parallel to the load in order to ensure a low power factor. Power converter such as an inverter is a typical non-linear load. Non-linear load generates harmonic currents in the energy conversion process. Many electrical equipment may be adversely affected by the harmonic current. There, passive or active filter have been used to reduce these harmonics current. Passive filter consisting of inductor and capacitor generates a reactive power. According to the combination of filter inductor and capacitor, reactive power can be adjusted. In this paper, we analyzed how the combination of inductor and capacitor affects the overall power factor by simulation and measurement.

Load-Carrying Capacity Assessment of Deteriorated Rural Bridge

  • Kim, Han-Joong;Kim, Jong-Ok;Yang, Seung-Ie
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.7
    • /
    • pp.36-45
    • /
    • 2002
  • Most of rural bridges have passed 30 years of age since they were built, which have to support unexpected overload caused by changed design load and excessive amount of transportation. For these rural bridges, repairs and replacements are needed. Even though there have been attempt to estimate the safety of existing bridges deteriorated with major defects, those approaches must rely on the observable damage and subsequent decisions are made subjectively. To avoid the high cost of rehabilitation, the bridge rating must correctly represent the present load-carrying capacity. Rating engineers use a methods such as Allowable Stress Design (ASD), Load Factor Design (LFD), and Load Resistance Factor Design (LRFD) to evaluate the bridge load carrying capacity. In this paper, the load rating methods are introduced, and it is illustrated how to use the load test data from literature survey. Load test is conducted to the bridge that was built 30 years ago in rural area. From load test results, new maintenance method is suggested instead of the bridge replacement.

Effects of Lower-Bound Resistances on Resistance Factors Calibration for Drilled Shafts (하한지지력이 현장타설말뚝의 저항계수에 미치는 영향)

  • Kim, Seok-Jung;Park, Jae-Hyun;Kim, Myoung-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.11
    • /
    • pp.51-60
    • /
    • 2014
  • Load and Resistance Factor Design (LRFD) is one of the limit state design methods, and has been used worldwide, especially in North America. Also, the study for LRFD has been actively conducted in Korea. However, the data for LRFD in Korea were not sufficient, so resistance factors suggested by AASTTO have been used for the design in Korea. But the resistance factors suggested by AASHTO represent the characteristics of bedrocks defined in the US, therefore, it is necessary to determine the resistance factors for designs in Korea, which can reflect the characteristics of bedrocks in Korea. Also, the calculated probabilities of failure from conventional reliability analyses which commonly use log-normal distribution are not realistic because of the lower tail that can be extended to zero. Therefore, it is necessary to calibrate the resistance factors considering the lower-bound resistance. Thus, this study calculates the resistance factors using thirteen sets of drilled shaft load test results, and then calibrates the resistance factors considering the lower-bound resistance corresponding to a target reliability index of 3.0. As a result, resistance factors from conventional reliability analyses were determined in the range of 0.13-0.32 for the shaft resistance, and 0.19-0.29 for the base resistance, respectively. Also, the lower bounds of resistance were determined based on the Hoek-Brown failure criteria (2002) and GSI downgrading. Considering the lower-bound resistances, resistance factors increased by 0~8% for the shaft, and 0~13% for the base, respectively.