Hysteresis Loss in a $Sm_1Ba_2Cu_3O_{7-\delta}$ Coated Conductor under Simultaneously Applied Field and Current with Phase Differences (위상차를 갖고 변화하는 자기장과 전류가 동시에 가해진 $Sm_1Ba_2Cu_3O_{7-\delta}$ Coated Conductor의 자기이력 손실)

  • Lee, Sang-Moo;Jung, Ye-Hyun;Kwak, Ki-Sung;Rhee, Joon-Kyu;Yoo, Jae-Un;Youm, Do-Jun;Kim, Ho-Sup;Ha, Hong-Soo;Oh, Sang-Soo
    • Progress in Superconductivity
    • /
    • v.10 no.2
    • /
    • pp.92-98
    • /
    • 2009
  • The magnetic field profiles near the surface of a $Sm_1Ba_2Cu_3O_{7-\delta}$ coated conductor(CC-tape) under magnetic field and current that were applied simultaneously with phase differences ${\phi}s$ were measured using scanning Hall probe method. Measurements were carried out along the elliptic load lines with $\phi=90^{\circ}\;and\;45^{\circ}$ for some $B_{peak},\;I_{peak}$ values. From the measured field profiles, sheet current density J(x, $B_a,\;I_a$) and magnetic flux density $B_0(x,\;B_a,\;I_a)$ profiles in the CC-tape were calculated. Using these J(x, $B_a,\;I_a$) and $B_0(x,\;B_a,\;I_a)$ profiles, we estimated the hysteresis energy loss Q in the CC-tape. The estimated Qs, together with our previous results for $\phi=0^{\circ}$ from [9], were compared with theoretical values based on Brandt's calculation.

  • PDF

Development and Hydraulic Characteristics of Continuous Block System in River Bank Protection (I) - Development and Application Review through Hydraulic Model Test - (일체형 식생호안블록 시스템 개발 및 수리특성 연구(I) -일체형 호안블록 개발 및 수리모형실험을 통한 적용성 검토-)

  • Jang, SukHwan
    • Journal of Wetlands Research
    • /
    • v.10 no.3
    • /
    • pp.87-97
    • /
    • 2008
  • This research focused on development and application feasibility for the coalesced continuous block system in river bank protection. Most of block systems in river bank are pre cast type and have some difficulties against high velocity flood condition or high pressure load, however, the continuous block system can be applied to flood damage recover as well as environmental vegetation block system in river bank. For the application review and analysis of hydraulic condition for this block system, hydraulic physical modeling was carried out. The physical model was built as a scale of 1:50 by Froude similitude measuring the water levels and the water velocities for vegetation application or not. In consequence, the water velocities were observed to decrease meanly 10.1%, and the water depths were to increase meanly 17.8% in case of the of design flood, $Q=200m^3/sec$. To verify the hydraulic physical modeling, the numerical modeling should be conducted for a close examination of vegetation application by one or two dimensional numerical analysis as a next study.

  • PDF

Evaluation of wind loads and wind induced responses of a super-tall building by large eddy simulation

  • Lu, C.L.;Li, Q.S.;Huang, S.H.;Tuan, Alex Y.;Zhi, L.H.;Su, Sheng-chung
    • Wind and Structures
    • /
    • v.23 no.4
    • /
    • pp.313-350
    • /
    • 2016
  • Taipei 101 Tower, which has 101 stories with height of 508 m, is located in Taipei where typhoons and earthquakes commonly occur. It is currently the second tallest building in the world. Therefore, the dynamic performance of the super-tall building under strong wind actions requires particular attentions. In this study, Large Eddy Simulation (LES) integrated with a new inflow turbulence generator and a new sub-grid scale (SGS) model was conducted to simulate the wind loads on the super-tall building. Three-dimensional finite element model of Taipei 101 Tower was established and used to evaluate the wind-induced responses of the high-rise structure based on the simulated wind forces. The numerical results were found to be consistent with those measured from a vibration monitoring system installed in the building. Furthermore, the equivalent static wind loads on the building, which were computed by the time-domain and frequency-domain analysis, respectively, were in satisfactory agreement with available wind tunnel testing results. It has been demonstrated through the validation studies that the numerical framework presented in this paper, including the recommended SGS model, the inflow turbulence generation technique and associated numerical treatments, is a useful tool for evaluation of the wind loads and wind-induced responses of tall buildings.

A Study on the Evaluation of Berthing Energy of Large-Sized Container Ships with the effect of Shallow Waters (대형 컨테이너선의 천수역 영향을 고려한 접안에너지 산출에 관한 연구)

  • Kim Chol-Seong;Lee Yun-Sok;Lee Chung-Ro;Cho Ik-Soon
    • Journal of Navigation and Port Research
    • /
    • v.29 no.8 s.104
    • /
    • pp.673-678
    • /
    • 2005
  • In order to improve the safety of ship berthing and the efficiency of berth operation in the harbour, the berthing energy acting on a ship in berthing maneuver need to be estimated properly. The berthing energy is used as one of the criteria to determine the maximum permissible load q{ fender as well as important factors to establish the berthing speed and the required power of tug-boat for pilot and ship operator. Some problems of berthing energy are discussed on the basis of the hydrodynamic aspects. Then, series calculations of berthing energy are carried out considering the effect of water depth on added mass and the ship shape for container series from 1,600TEU to 12,000TEU.

The Effects of Heat-treatment on the Mechanical Properties of High Chromium Cast Irons (고크롬 주철의 기계적 특성에 미치는 열처리 영향)

  • Kim, Sug-Won;Kim, Ki-Kon;Park, Jin-Sung;Kim, Dong-Keun;Yoon, Young-Gap
    • Journal of Korea Foundry Society
    • /
    • v.25 no.1
    • /
    • pp.23-29
    • /
    • 2005
  • Mechanical characteristics of Hi-Cr cast irons containing 16.8%Cr and 3.0%C were studied with various heat treatments. After as-cast Y-block ingots were annealed fully, the ingots were machined into cylinderical specimens with the size of 9mm in diameter and 20mm in length in order to investigate the effect of heat-treatments on mechanical characteristics of high Cr cast irons. All specimens were heat-treated by quenching- tempering, austempering and cyclic heat at the various temperatures(950, 1000, 1050 and $1100^{\circ}C$) respectively. The wear amount was measured for each heat-treated specimens against the counterpart of a hardened SKD11 steel at the following conditions; wearing velocity: 0.7 m/s, load: 100N and sliding distance: 70 km. After as-cast specimens were annealed, fine $M_{3}C$ carbides were formed, which affected the hardness and the wear resistance of Hi-Cr specimens. High hardness and good wear resistance were appeared on the specimens treated at 950 and $1000^{\circ}C$ and the austempered specimens show excellent wear resistance as well as high hardness.

Investigation of Institutional Improvement through Evaluation of Zero-Energy Buildings (제로에너지 빌딩 평가를 통한 제도적 개선방안에 대한 조사 연구)

  • Chae, Sookwon;Kim, Juhwan;Chae, Hyunbyung
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.83-94
    • /
    • 2016
  • Energy use has been recognized worldwide as a main cause of global warming and it is at the center of climate change. In this study, problems and measures of zero-energy building construction are investigated and analyzed. Based on the results, evaluation criteria of the zero-energy building are suggested. Performance related factors(Q) representing the environmental grade were divided into three categories as outdoor, indoor environment and maintenance. Energy related factors(LR) representing the energy load were divided into an energy, materials & resources, water cycle management, land use and transportation. Detailed fifty three items are listed for the evaluation under the consideration of energy, water cycle management sections gave weight. Upon receiving the first in the environment friendly certification system, Seoul Central Post Office and Seoul Metropolitan Water Supply Center evaluated. The reason why this score difference is due to lack of use of new generation energy building construction is required expensive costs so need expansion of governmental support. This effort is successful zero energy building construction and copes with global warming and climate change.

Numerical Model for Predicting Sand Bar Formation around River Mouth (하구역의 사주 형성 예측을 위한 수치 모델)

  • Kuroiwa, Masamitsu;Matsubara, Yuhei;Suzuki, Yoko;Kuchiishi, Takayuki
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.2
    • /
    • pp.96-102
    • /
    • 2014
  • A three-dimensional beach evolution model was presented to predict morphodynamics around a river mouth. The presented model was based on the depth-averaged (2DH) and quasi three-dimensional (Q-3D) nearshore current modules, and the model took into account shoreline changes, the effect of advection diffusion of suspended load and discharged sediments from the river. First, the 3D beach evolution model was applied to the formation of sand spits and terrace at the river mouth in order to investigate the performance of the model. Secondly, the model was applied to the river mouth at the Ara River, facing the Sea of Japan. The formation of sand spit at the Ara River in winter season was reproduced. The computed result showed qualitatively agreement with field site observation.

Full-scale tests and finite element analysis of arched corrugated steel roof under static loads

  • Wang, X.P.;Jiang, C.R.;Li, G.Q.;Wang, S.Y.
    • Steel and Composite Structures
    • /
    • v.7 no.4
    • /
    • pp.339-354
    • /
    • 2007
  • Arched Corrugated Steel Roof (ACSR) is a kind of thin-walled steel shell, composing of arched panels with transverse small corrugations. Four full-scale W666 ACSR samples with 18m and 30m span were tested under full and half span static vertical uniform loads. Displacement, bearing capacities and failure modes of the four samples were measured. The web and bottom flange in ACSR with transverse small corrugations are simplified to anisotropic curved plates, and the equivalent tensile modulus, shear modulus and Poisson's ratio of 18m span ACSR were measured. Two 18 m-span W666 ACSR samples were analyzed with the Finite Element Analysis program ABAQUS. Base on the tests, the limit bearing capacity of ACSR is low, and for half span loading, it is 74-75% compared with the full span loading. When the testing load approached to the limit value, the bottom flange at the sample's bulge place locally buckled first, and then the whole arched roof collapsed suddenly. If the vertical loads apply along the full span, the deformation shape is symmetric, but the overall failure mode is asymmetric. For half span vertical loading, the deformation shape and the overall failure mode of the structure are asymmetric. The ACSR displacement under the vertical loads is large and the structural stiffness is low. There is a little difference between the FEM analysis results and testing data, showing the simplify method of small corrugations in ACSR and the building techniques of FEM models are rational and useful.

Piezoelectric Energy Harvesting Characteristics of Hard PZT Interdigitated Electrode (IDE) Unimorph Cantilever (Hard PZT IDE 유니몰프 캔틸레버의 압전 에너지 하베스팅 특성)

  • Lee, Min-seon;Kim, Chang-il;Yun, Ji-sun;Park, Woon-ik;Hong, Youn-woo;Cho, Jeong-ho;Paik, Jong-hoo;Park, Yong-ho;Jang, Yong-ho;Choi, Beom-jin;Jeong, Young-hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.8
    • /
    • pp.501-507
    • /
    • 2017
  • A unimorph piezoelectric cantilever generator with an interdigitated electrode (IDE) was developed for vibration energy harvester applications driven in the longitudinal mode. Hard lead zirconate titanate (PZT) ceramic with a high $Q_m$ of 1,280 was used as the piezoelectric active material. Ten PZT sheets produced by tape casting were laminated and co-fired with an Ag/Pd IDE at $1,050^{\circ}C$ for 2 h. The approximately $280{\mu}m$-thick co-fired PZT laminate with the IDE was attached to a stainless steel substrate with an adhesive epoxy for the fabrication of an IDE unimorph cantilever. Its energy harvesting characteristics were evaluated: an output power of $1.1{\mu}W$ at 120 Hz across the resistive load of $700k{\Omega}$ was obtained, corresponding to a normalized power factor of $4.1{\mu}W/(G^2{\cdot}cm^3)$.

Improving Detection Method of Pseudomonas aeruginosa, an Important Index Organism of Bottled Water Quality (먹는샘물의 녹농균 분포 및 검사방법 개선에 관한 연구)

  • 정현미;김동빈
    • Korean Journal of Microbiology
    • /
    • v.36 no.3
    • /
    • pp.242-248
    • /
    • 2000
  • Since the official allowance of bottled water at Korean domestic market in 1995, Pseudomo~zas aemginosu has been detected from 2.3% and 1.2% of source and products of bottled water sa~nple tested, respectively. according to the nation-wide dala froin May 1995 to December 1996. Therefore, P aeivginosa was the second most important parameter, next to colifoi~ns, anlong the bacieriological parameters regulated for bonled water. The official standard method initially adopted the Japanese officlal method and Standard Methods of the US, w~hich is using aspai-agiii-acetamid mnedia(A-A method). how eve^; the method showed low specificity regardless of the high sensitivity. The $42^{\circ}C$ growth test was the best biochemical featu1-e differentiating the P uelarginosu 6-om P aei-uginosa-like species such as P puririir and P Jhoi.escens amo1zg the other characierisiics such as fluorescence pigment_ pyocyanin, casein hy&olysis, etc. Thel-efore, addition of the $42^{\circ}C$ growth Lest in advance ofthe biochemical identification test, when sainple is positive by A-A method, should strengthen the spec~IiclQ w~tli ~ninin~um addition of testing load.

  • PDF