• 제목/요약/키워드: living noise

검색결과 290건 처리시간 0.025초

애완동물과의 공생을 고려한 공동주택 계획요소 연구 (A Study on the Planning Elements for Apartment Residents Living with Companion Animals)

  • 김선아;이연숙;이수진
    • KIEAE Journal
    • /
    • 제5권2호
    • /
    • pp.27-34
    • /
    • 2005
  • The purpose of this study were to examine actual conditions of apartment residents living with their companion animals and to identify their residential stress and needs of planning elements under those conditions. Questionnaire survey was adopted in this study, and 100 cases were used for data analysis. The subjects for this study were limited to the residents breeding pets in their apartments. The results of this study are as follows: Most of the residents share their living spaces with pets together like their family without spatial restrictions. They indicated problems related to breeding pets in their residence such as walking the dog, cleaning home, leaving pets alone, noise and unpleasant smell. However, they didn't seem to be stressed a lot for their living environments. In terms of residential planning elements, floor plans for effective natural ventilation, balcony with sufficient sunlight, sound proof system, easy-maintenance interior material, unlash area, rubbish bin, mechanical ventilation and central vacuum system and safe electric outlet were highly indicated.

다부하를 갖는 이중 하프 브릿지 유도가열 조리기 (Dual Half Bridge Induction Heating Cooker With Multiple Loads)

  • 정용채;전효식;한성진;노희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.538-540
    • /
    • 1997
  • A new dual half bridge induction heating cooker circuit with multiple loads is proposed for reducing the acoustics noise which is caused by the difference between operating frequencies q adjacent loads. This circuit has minimum loss due to the zero voltage switching characteristic. According to the mode analysis of the proposed circuit, we explain the operation of the dual half bridge induction heating cooker circuit The proto-type circuit with 2.8kW power consumption is builted and tested to verify the operation q the proposed circuit.

  • PDF

미국거주 한국인의 저층 공동주택 소음 환경에 대한 주관적 평가 - Athens시 중심으로 - (A Subjective Evaluation on the Noise Environment of the Low - rise Multifamily House of Korean lived in Athens, America)

  • 곽경숙
    • 한국주거학회논문집
    • /
    • 제10권2호
    • /
    • pp.203-212
    • /
    • 1999
  • The purpose of this study is to evaluate the Korean residents' subjective opinion of the noise on the lowrise multifamily house in America. The results of this study can be applied for the prevention of noise when planning cities, roads, and multifamily houses in Korea. The subjects of this study are three kinds of multifamily houses and their 124 Korean residents in Athens, America. The results of this study are as follows. The Korean residents felt the noise from lawn mowers and the sound of filter fan of air conditioners were higher than all the other external noise. They were disturbed a little by the external noise. The air borne sound was recognized a little by Korean residents but they only felt moderate sound of building services and household equipment from the solid borne sound of the internal noise. They suffered worse from external noise in the summer and they felt worse from 8~12 o'clock due to external noise and 20~24 o'clock due to internal noise. The Korean residents liked the sound of birds or insects, the sound of cars and trains. However many Korean people in Athens disliked the sounds of birds or insects and lawn mowers more than these sounds in Korea. The Korean residents who were living in the apartment houses felt better than those in the other multifamily houses.

  • PDF

공사장 소음진동 규제기준 개선방안에 관한 연구 (A Study on the improvement plan of regulatory standard for construction noise and vibration)

  • 박영민;김경민
    • 환경영향평가
    • /
    • 제22권4호
    • /
    • pp.369-379
    • /
    • 2013
  • Noise and vibration problems at the construction site, expansion of construction scale and frequency of urban construction is increased, has given the damage to local residents. Also, the result of civil complaint about noise and vibration that occurred in 2011 was 56,244; it is showing an increasing trend of more than 4% annually. In particular, the construction noise and vibration, the civil complaints of around construction site accounts for 64.6%(36,353), are harmful to the tranquility of living environment. As a result, the government has managed to strengthen the regulatory standard of construction noise (65dB(A), Day-time) from 2011. However, the regulatory standard of construction noise and vibration does not meet and also complaints related the construction noise and vibration not decreased. Because the management system can be applied to the construction site is insufficient and a shortage of manpower. In this study, investigated the status and problems of the regulatory standards related to construction noise and vibration, we propose an efficient management plan of construction noise and vibration.

도로교통소음에 대한 고층건물의 외부 소음분포 예측에 관한 연구 (A study on the Prediction of the Road Traffic Noise Distribution around the High-Rise Building)

  • 정석환;김대웅;임태섭;김병선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1087-1092
    • /
    • 2006
  • Recently, traffic noise level is rapidly increasing, and it is crowed caused by recently overcrowded and overgrown cities, and increasing traffic volume is emerging as a major factor of disrupting the living and working environment. In this situation, citizens are increasingly complaining about the traffic noise. The noise level of in major cities in Korea is serious and affects on citizens physically and psychologically. Many people live in residential areas around crowed roads in major cities, such as Seoul. Accordingly, the purpose of this study is to predict outside noise distribution of building through survey and simulation to make better sound insulation performance research. The result of this study shows that the traffic noise is influenced from ground 50m and analyzed that form of building and arrangement type must be considered to the level of noise decrease.

  • PDF

설문에 의한 철도 진동의 거리별 영향 조사 (Effect of Vibration From Railroad by Distance using Questionare)

  • 유승도;신동석;설증민
    • 소음진동
    • /
    • 제7권3호
    • /
    • pp.419-426
    • /
    • 1997
  • The psychological, physiological, and material effects of ground vibrations induced from railroad were surveyed with the magnitudes of vibration sensing using questionnaire on residents living near railroad. These magnitude of vibration sensing and effects were compared as rate or percent total based on double distances from railraod. Also overall effects of railraod vibrations were compared with vibration levels measured or predicted. The about 70% of residents living within 40m from railroad sense railroad vibration, 15% of residents are influenced phychologically. But physilogical and material effects disappeared beyond 40m.

  • PDF

변압기용 고효율 차음판의 진동 및 소음 비교 (Comparison of vibration and noise of higher utility factor Insulation Panel for Transformer)

  • 정재환;이정환;정한얼;임동수;김진;최병근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.112-116
    • /
    • 2007
  • Highly damped insulation panel for transformer construction is needed in residential area because the making noise from transformer substation in inner city is appeared a lost of problem by increasing to conserve living environment. Therefor in this paper, the vibration and noise characteristic effect of cork-type and sponge-type that is attached between insulation panel and enforce beam in transformer is analized using real size transformer experimentally.

  • PDF

Computer Simulation을 이용한 SIP 항타소음의 예측에 관한 연구 (A Study on the Prediction of SIP Piling Noise by Computer Simulation)

  • 이병윤;윤해동;김재수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2001년도 학술논문발표회
    • /
    • pp.14-21
    • /
    • 2001
  • Recently, with the increasing of construction works, large construction equipment are used to reduce the term of work and labor cost in construction field. Therefore, construction equipment noise has caused much annoyance for a number of dweller in nearby construction field and it has become a very serious problem in our living environment. Nevertheless, in our country, adequite guidelines for the construction equipment noise are very deficiency because of the lack of basic data and insufficient research works. From this point of view, this study attempts to survey the characteristics and prediction of SIP piling noise. On the basis of measurement value, we analysed about prediction possibility of SIP piling noise by computer simulation.

  • PDF

역전파 알고리즘에 의한 덕트내 소음의 능동제어 (Active Control of Sound in a Duct System by Back Propagation Algorithm)

  • 신준;김흥섭;오재응
    • 대한기계학회논문집
    • /
    • 제18권9호
    • /
    • pp.2265-2271
    • /
    • 1994
  • With the improvement of standard of living, requirement for comfortable and quiet environment has been increased and, therefore, there has been a many researches for active noise reduction to overcome the limit of passive control method. In this study, active noise control is performed in a duct system using intelligent control technique which needs not decide the coefficients of high order filter and the mathematical modeling of a system. Back propagation algorithm is applied as an intelligent control technique and control system is organized to exclude the error microphone and high speed operational device which are indispensable for conventional active noise control techniques. Furthermore, learning is performed by organizing acoustic feedback model, and the effect of the proposed control technique is verified via computer simulation and experiment of active noise control in a duct system.

변압기용 고효율 차음판의 진동 및 소음 비교 (Comparison of vibration and noise characteristic of high efficiency Insulation Panel for Transformer)

  • 정재환;장용석;임동수;김진;최병근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.1005-1009
    • /
    • 2008
  • The high efficiency insulation panel for transformer construction is needed in residential area because the making noise from transformer substation in side of city is appeared a lost of problem by increasing to conserve the living environment. Therefor in this paper, first the vibration and noise characteristic of existing insulation panel is analyzed according to attached material, cork and sponge-type. Second the insulation of sound performance is compared between the existing insulation panel. And high efficiency insulation panel that is proposal in this paper.

  • PDF