• Title/Summary/Keyword: livestock house

Search Result 124, Processing Time 0.032 seconds

Concentrations of Particulate Matter Exposed to Farm Workers in the Broiler Houses (육계사 내 작업자의 미세먼지 노출량 현장모니터링)

  • Seo, Hyo-Jae;Oh, Byung-Wook;Kim, Hyo-Cher;Sin, So-Jung;Seo, Il-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.5
    • /
    • pp.27-37
    • /
    • 2020
  • As domestic meat consumption increases, the broiler production industry has been larger and denser. The concentration of particulate matter (PM) and harmful gases generated is also increasing inside livestock house. However, the current research status of PM exposed to farm workers and the health effects are in the early stage. To understand PM concentration affecting workers in the broiler house, field monitoring was conducted according to its size distributions. Concentrations of PM10, PM2.5, and TD (Total Dust) were monitored using personal air samplers with teflon filter during working and moving periods considering the ventilation systems of 6 broiler houses. The purpose of this study is to monitor the PM concentration in the experimental broiler houses operated by forced ventilation system generally used in Korea and to evaluate the regional concentrations through airflow pattern. The PM concentrations were increased from inlet to outlet vents resulting in 1,872 of TD, 1,385 of PM10, and 209 ㎍/㎥ of PM2.5, respectively. The TD and PM10 concentrations were increased when the workers and broilers were moving. Among them, the particle size that occupied the largest amount of PM was 13.75 ㎛. These results suggest that personal protection equipments are important to reduce the health effect from PM inhalation.

Design for Landfill Gas Appliation by Low Calorific Gas Turbine and Green House Optimization Technology (Low Calorific Gasturbine 매립지 적용 및 유리온실 운용기술 설계)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Lee, Jung-Bin;Rhim, Sang-Gyu
    • New & Renewable Energy
    • /
    • v.6 no.2
    • /
    • pp.27-32
    • /
    • 2010
  • Low Calorific Gas Turbine (LCGT) has been developed as a next generation power system using landfill gas (LFG) and biogas made from various organic wastes, food Waste, waste water and Livestock biogas. Low calorific fuel purification by pretreatment system and carbon dioxide fixation by green house system are very important design target for the optimum applications of LCGT. Main troubles of Low Calorific Gas Turbine system was derived from the impurities such as hydro sulfide, siloxane, water contained in biogas. Even if the quality of the bio fuel is not better than natural gas, LCGT may take low quality gas fuel and environmental friendly power system. The mechanical characterisitics of LCGT system is a high energy efficiency (>70%), wide range of output power (30 kW - 30 MW class) and very clean emission from power system (low NOx). A green house has been designed for four different carbon dioxide concentration from ambient air to 2000 ppm by utilizing the exhaust gas and hot water from LCGT system. LCGT is expected to contribute achieving the target of Renewable Portfolio Standards (RPS).

The Correlation between Ammonia Emissions and Bedding Materials in a Cow House

  • Phan, Nhu-Thuc;Sa, Jae-Hwan;Jeon, Eui-Chan;Lee, Sang-Rak
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.1
    • /
    • pp.33-41
    • /
    • 2010
  • Because ammonia from livestock production may substantially contribute to environmental pollution, emissions from all possible sources (housing systems, manure storage, manure application, outside grazing) should be reduced. The purpose of this study was to investigate the effect of different bedding materials on ammonia emissions in a cow house. By applying a combination of four treatment types: treatment $1-T_1$ (sawdust (50%)+sawdust pellets (50%)), treatment $2-T_2$ (sawdust (50%)+corn stalk pellets (50%)), treatment $3-T_3$ (sawdust (100%)), and treatment $4-T_4$ (sawdust (50%)+palm kernel meal pellets(50%)) as bedding materials in a cow house, the effects of such treatments on ammonia flux were assessed in approximately one month. The magnitude of ammonia emissions (mg $m^{-2}\;min^{-1}$) varied in the following order: $T_1$(2.226), $T_4$(2.052), $T_2$(1.845), and $T_3$(1.712). The patterns of pH had a decreasing trend for all bedding treatments during the experiment, and there was no significant relationship with ammonia flux. The results reveal that the most important factor influencing ammonia emissions is the physical structure of the bedding types.

Study on the Management Level of Pathogenic Bacteria in HACCP System Implemented Animal Farms (HACCP 적용 농장의 병원성 세균 관리수준에 관한 연구)

  • Lee, Gi-Yun;Lee, Joo-Yeon;Back, Seung-Hee;Hwang, In-Jin;Lee, Kyung-Soon;Kim, Young-Su;Kim, Byoung-Hoon;Kim, Hyun-Soo;Kang, Soo-Cheol;Cho, Jea-Jin;Park, Min-Seo;Suk, Hee-Jin;Nam, In-Sik
    • Journal of Animal Science and Technology
    • /
    • v.53 no.1
    • /
    • pp.67-74
    • /
    • 2011
  • The aim of this study was to understand the management level of pathogenic bacteria in HACCP system implemented animal farms. Microbial samples were collected from manure, floor, compost depot, manure on belt, low milk tank, dust in laying house and egg collector in HACCP system implemented Korean beef cattle, dairy cattle, swine, and laying Hens farms. O157, O111 and O26 strains of E. coli were not detected in HACCP system implemented Korean beef cattle farm. The detection rate of E. coli from manure and floor in HACCP system implemented cattle farms (Korean beef cattle and dairy farm) was lower than those of non-HACCP system implemented cattle farm. Salmonella spp. was detected in HACCP system implemented cattle farms (Korean beef cattle and dairy farm). Compared with pervious studies, lower detection rate of Salmonella spp. at floor and compost depot in HACCP system implemented swine and commercial layer farms were indicated. In conclusion, implementation of HACCP system in animal farms would enhance the management level of biological hazard compare to normal animal farms.

Correlation Analysis between the Breeding Value of Carcass Traits in Hanwoo (Korean Brown Cattle), Bos Taurus, L. and Spot Intensity on Two-dimensional Gel Electrophoresis

  • Seo, Kang Seok;Shen, Y.N.;Salces, A.J.;Yoon, D.H.;Lee, H.G.;Kim, S.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.10
    • /
    • pp.1404-1408
    • /
    • 2006
  • In order to investigate the genetic marker associated with economic performance in Hanwoo (Korean Brown Cattle), proteomic approach was used. Breeding values were estimated from performance tested steers. The top 20 and bottom 19 steers based on carcass weight (CW), eye muscle area (EMA), backfat thickness (BF) and marbling score (MS) evaluation for one progeny testing period was used. Meat samples dissected from longissimus dorsi muscles were taken from the slaughter house and analyzed for two-dimensional gel electrophoresis. A total of 102 significant spots out of total 146 on each gel were detected and compared with the reference gel (synthetic gel) to be evaluated. Four candidate spots for marbling score were identified: 205, 84, 204 and 198. The study confirmed the relationship between breeding values of economic traits of Hanwoo cattle and spot intensity.

Analysis of Airflow Characteristics in an Enclosed Nursery Pig House (무창자돈사의 공기유동 특성 분석)

  • Song, Jun-Ik;Choi, H.L.;Yang, C.B.;Kim, H.T.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.107-114
    • /
    • 2005
  • Experiments were carried out to evaluate the air speed distribution of an enclosed nursery pig bay in summer and winter. The data taken by experiments were compared to validate with the calculated air speeds by a commercial CFD code, FLUENT. Air basically enters into the bay through perforated circular ducts overhanged on the ceiling, leaves through a exhaust fan attached on the end-wall of the bay. Air speeds were measured as 2 ${\sim}$ 2.5 mls at the perforated holes in the duct in winter and 7 mls in summer. The validation showed that a CFD simulaton is one of feasible methods to predict airspeed distribution in the nursery pig bay.

Effect of pH on Hydrogen Fermentation of Food Waste with Livestock Wastewater (음식물쓰레기 수소발효 시 pH 영향 및 축산폐수와의 혼합 발효)

  • Jang, Hae-Nam
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.4
    • /
    • pp.5-9
    • /
    • 2016
  • In the modern industrial society, huge amount of organic wastes have exceeded the society's self-cleaning capability, caused pollution of the whole environment, including water quality, soil, and the air, and become a big burden of waste treatment. Moreover, the emission of green house gases brought by the continual combustion of fossil fuels has facilitated the global warming. The simultaneous effect of initial and operational pH on $H_2$ yield was expressed using mathematical equation and optimized. The optimal initial and cultivation pH was 7.50 and 6.01, respectively. Addition of livestock wastewater to food waste substantially decreased the amount of alkali requirement and also improved the $H_2$ fermentation performance.

Rearing managements of pig farms and survey on pneumonia of slaughtered pigs (양돈장 사양관리와 도축돈 폐 병변조사)

  • Chu Keum-Suk;Yuk Hyun-Su;Chon Hee-Woong;Song Hee-Jong
    • Korean Journal of Veterinary Service
    • /
    • v.29 no.1
    • /
    • pp.27-36
    • /
    • 2006
  • This studies were carried out to investigate the rearing managements of pig farms and survey on pneumonia of the slaughtered pigs from 5 selected herds located in Jangsu, Jeonbuk. Isolated aerobic microorganisms from pneumonic lung were examined antibiotic susceptibility and tested serological antibody titers of the herd base. Prevalence rate of pneumonia were examined according to rearing and health management conditions of pig farms. Prevalence rate of pneumonia were detected in 78.8% and enzotic pneumonia. In 47.7%, pleuropneurnonia in 31.1%. In serological antibody titers showed the positive reaction with 54.4% in Actinobacillus pleuropneumonia serotype 5, 44.8% in Pasteurella multocida, 36.8% in A pleuropneurnonia serotype 2, 13.6% in Mycoplasmal pneumonia. Isolated aerobic microorganisms were examined antibiotic susceptibility and showed the high activity in gentamicin (58.3%), enrofloxacin (53.3%), norfloxacin (51.6%), cephalothin (41.7%) and low activity in amoxycillin (98.3%), oxytetracycline (98.3%), penicillin G (90.0 %), tetracycline (88.4%), ampicillin (88.3%). Farm managements were deficient effect of humidity in swine house but ammonia gas all appeared the 10 ppm that were recommendation density, below.

The comparative study on Newcastle disease virus antibody titer by hemagglutination inhibition test and enzyme-linked immunosorbent assay (혈구응집억제반응과 효소면역측정법을 이용한 닭 뉴캣슬병 바이러스에 대한 혈중항체가 비교)

  • Han, Sung-Tae;Lee, Cheong-San;Kwak, Hak-Koo;Song, Jong-Han;Lee, Jong-In
    • Korean Journal of Veterinary Service
    • /
    • v.26 no.3
    • /
    • pp.215-219
    • /
    • 2003
  • This study was conducted to investigate the similarity between hemagglutination inhibition (HI) test and enzyme-linked immunosorbent assay(ELISA) titers and sample to positive ratio (S/P ratio) of Newcastle disease(ND) virus. To perform this study, the 372 sera of broiler chicks and 120 sera of layers and breed chicks were collected from slaughter house and farms, respectively. As a result of HI test out of different chicks, the positive percentage of ND antibody titer of broiler, layer and breeder, when a standard positive HI titer were '2', was 84.4%, 100% and 100%, respectively. The positive percentage of ND antibody titer by ELISA was shown 38.4%, 100% and 100% and S/P ratio were also shown 81.5%, 98.2% and 99.2%, respectively. The results of comparative survey with same sera by two experimental methods were as follows; In low HI titer, ELISA titer was not similar to HI titer, but S/P ratio was similar to it. In high HI titer, ELISA titer was not similar to HI titer. Therefore, HI titer was more similar to S/P ratio than ELISA titer.

Efficiency Evaluation of Nozawa-Style Black Light Trap for Control of Anopheline Mosquitoes

  • Lee, Hee-Il;Seo, Bo-Youl;Shin, E-Hyun;Burkett, Douglas A.;Lee, Jong-Koo;Shin, Young-Hack
    • Parasites, Hosts and Diseases
    • /
    • v.47 no.2
    • /
    • pp.159-165
    • /
    • 2009
  • House-residual spraying and insecticide-treated bed nets have achieved some success in controlling anthropophilic and endophagic vectors. However, these methods have relatively low efficacy in Korea because Anopheles sinensis, the primary malaria vector, is highly zoophilic and exophilic. So, we focused our vector control efforts within livestock enclosures using ultraviolet black light traps as a mechanical control measure. We found that black light traps captured significantly more mosquitoes at 2 and 2.5 m above the ground (P<0.05). We also evaluated the effectiveness of trap spacing within the livestock enclosure. In general, traps spaced between 4 and 7m apart captured mosquitoes more efficiently than those spaced closer together (P>0.05). Based on these findings, we concluded that each black light trap in the livestock enclosures killed 7,586 female mosquitoes per trap per night during the peak mosquito season (July-August). In May-August 2003, additional concurrent field trials were conducted in Ganghwa county. We got 74.9% reduction (P<0.05) of An. sinensis in human dwellings and 61.5% reduction (P>0.05) in the livestock enclosures. The black light trap operation in the livestock enclosures proved to be an effective control method and should be incorporated into existing control strategies in developed countries.