• Title/Summary/Keyword: liquid flow

Search Result 2,932, Processing Time 0.032 seconds

Numerical analysis of LNG vaporizer heat transfer characteristic in LNG fuel ship (선박용 액화천연가스 기화기의 열전달 특성의 수치해석)

  • Lee, Dae-Chul;Afrianto, Handry;Chung, Han-Shik;Jeong, Hyo-Min
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.22-28
    • /
    • 2013
  • The heat transfer characteristics of LNG(Liquefied Natural Gas) vaporizer on the ship was performed by numerical simulation to get the optimum NG(Natural Gas) generating condition. The glycol-water was used for heating in LNG vaporizer, and the cooling water of main engine was used as heating souse for glycol-water. This cooling water temperature increases again after recirculating from the main engine, and then it can be used to heat the glycol-water. The numerical analysis results has good agreement with the experimental results by liquid nitrogen for validation. So CFD technique was used to simulate the heat transfer characteristics of LNG vaporizer on the ship. The numerical results show that the operation condition of LNG vaporizer shows NG temperature of $6^{\circ}C$ in the outlet of LNG vaporizer, and the mass flow rates of LNG and glycol-water were showed 0.111 kg/s and 1.805 kg/s, respectively.

Characteristics of Chemiluminescence Intensities of Kerosene/Air Swirl Flames (케로신/공기 와류 화염의 화학발광 세기 특성에 관한 실험적 연구)

  • Lee, Hyeonjae;Seo, Seonghyeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.6
    • /
    • pp.485-496
    • /
    • 2015
  • The present study presents experimental results on the characteristics of emission spectra of kerosene/air swirl flames. The aviation fuel Jet A-1, which is used for the liquid rocket engines of the Korea Space Launch Vehicle, is used with three different swirlers to investigate the swirl strength effects. The emission spectra from the flames are measured with a spectrometer as the swirl strength and combustion air temperature are varied. Chemiluminescence intensities of $OH^*$, $CH^*$ and $C_2{^*}$ are identified from the spectra. The chemiluminescence intensities from the kerosene flames show sensitivity to the swirl strength and are affected by changes in the combustion air temperature. Among the three radicals of interest, $C_2{^*}$ show the most significant changes in chemiluminescence intensity with the swirl strength and equivalence ratio. The intensity ratios $I_{OH^*}/I_{CH^*}$ and $I_{C_2{^*}}/I_{CH^*}$ are adequate for indicating changes in the equivalence ratio with the air and fuel mass flow rates, respectively.

Numerical Simulation of Surface Tension-Dominant Multiphase Flows by Using Volume-Capturing Method and Unstructured Grid System (비정렬격자계와 체적포착법을 사용한 표면장력이 지배적인 다상유동 수치해석)

  • Myong, Hyon-Kook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.7
    • /
    • pp.723-733
    • /
    • 2011
  • A numerical method of the CSF(Continuum Surface Force) model is presented for the calculation of the surface tension force and implemented in an in-house solution code(PowerCFD). The present method(code) employs an unstructured cell-centered method based on a conservative pressure-based finite-volume method with volume capturing method(CICSAM) in a volume of fluid(VOF) scheme for phase interface capturing. The application of the present method to a 2-D liquid drop problem is illustrated by an equilibrium and nonequilibrium oscillating drop calculation. It is found that the present method simulates efficiently and accurately surface tension-dominant multiphase flows.

Comparative Analyses of Bioactive Constituents from Forsythia suspensa and Forsythia viridissima by HPLC-DAD

  • Won, Tae-Hyung;Liao, Lijuan;Lee, Seung-Ho;Son, Jong-Keun;Shin, Jong-Heon
    • Natural Product Sciences
    • /
    • v.17 no.4
    • /
    • pp.328-336
    • /
    • 2011
  • A high-performance liquid chromatography (HPLC) with diode array detector (DAD) method was established for the discrimination of a folk medicine Forsythia suspensa and Forsythia viridissima. Five and three representative metabolites of the lignan and phenolic glycoside classes were selected for the analysis from F. suspensa and F. viridissima, respectively. The optimal chromatographic conditions were obtained on an ODS column (5 ${\mu}m$, $4.6{\times}250$ mm) with the column temperature at $40^{\circ}C$. The mobile phase was composed of methanol and 0.3% acetic acid using an isocratic elution with the flow rate 1 mL/min. Detection wavelength was set at 280 nm. All calibration curves showed good linear regression ($r^2$ > 0.996) within test ranges. Limits of detection (LOD) and limits of quantitation (LOQ) values were lower than 0.096 and 0.291 ${\mu}g/mL$, respectively. The developed method provided satisfactory precision and accuracy with overall intra-day and inter-day variations of 0.07-0.63% and 0.14-0.62%, respectively, and the overall recoveries of 97.79-102.46% for all of the compounds analyzed. In addition, effectiveness of diverse extraction methods was compared to each other for the development of standard analytical method. The verified method was successfully applied to the quantitative determination of representative metabolites in fifty-three commercial F. suspensa samples and fifteen commercial F. viridissima samples from diverse sources. The overall analytical results showed the unequivocal differences in bioactive constituents between F. suspensa and F. viridissima.

Quantitative Analysis of Ellagic Acid in Nymphaea tetragona Georgi Root by HPLC-UVD (HPLC-UVD를 이용한 수련(Nymphaea tetragona Georgi)의 Ellagic Acid 정량 분석)

  • Lee, Dong Young;Jeong, Eun Ju;Jeon, Byung Ju;Sung, Sang Hyun
    • Korean Journal of Pharmacognosy
    • /
    • v.45 no.1
    • /
    • pp.84-87
    • /
    • 2014
  • A high performance liquid chromatography (HPLC) method for the quantitation of ellagic acid in Nymphaea tetragona was developed for the quality control of functional cosmetic ingredient, the extract of N. tetragona. Separation and quantitation were successfully achieved with a Kromasil C18 column ($5{\mu}m$, $250mm{\times}4.6mm$, i.d.) by isocratic elution of a mixture of acetonitrile containing 0.1% trifluoroacetic acid and water containing 0.03% phosphoric acid at a flow rate of 1.0 ml/min. The UV detector was used for the detection and the wavelength for quantitation was set at 254 nm. The presence of ellagic acid in the extract was determined by comparison of retention time and spiking with authentic standard. Analytical results showed good linearity ($R^2=0.99996$) in relatively wide concentration ranges. The R.S.D. for precision test was less than 3.0%. Recovery of the compound was 98.55~101.72% with R.S.D values less than 4.0%. In conclusion, this method has been successfully applied to the determination of ellagic acid in N. tetragona.

Concentration and Environmental Loading of Veterinary Antibiotics in Agricultural Irrigation Ditches

  • Kim, Sung-Chul;Chung, Doug Young;Kim, Kye Hoon;Lee, Ja Hyun;Kim, Hyo Kyung;Yang, Jae E.;Ok, Yong Sik;Almarwei, Yaser A.O.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.6
    • /
    • pp.867-876
    • /
    • 2012
  • The concentration of veterinary antibiotics in aqueous and sediment matrices was measured in agricultural irrigation ditches bordering several animal-feeding operations (AFOs) and then compared to its concentration in the watershed. Analytical determination in aqueous samples was based on solid phase extraction (SPE) and appropriate buffer solutions were used to extract residuals in sediment samples. Separation and detection of extracted veterinary antibiotics were performed with high performance liquid chromatograph tandem mass spectrometry (HPLC/MS/MS). In general, higher concentrations of antibiotic were observed in the aqueous phase of irrigation ditches, with the highest concentration of erythromycin hydrochloride (ETM-$H_2O$) of $0.53{\mu}g\;L^{-1}$, than in aqueous watershed samples. In contrast, higher concentrations were measured in river sediment than in irrigation ditch sediment with the highest concentration of oxytetracycline of $110.9{\mu}g\;kg^{-1}$. There was a high calculated correlation ( > 0.95) between precipitation and measured concentration in aqueous samples from the irrigation ditches for five of the ten targeted veterinary antibiotics, indicating that surface runoff could be an important transport mechanism of veterinary antibiotics from field to environment. Further, environmental loading calculation based on measured concentrations in aqueous samples and flow information clearly showed that irrigation ditches were 18 times greater than river. This result suggests the likelihood that veterinary antibiotics can be transported via irrigation ditches to the watershed. The transport via surface runoff and likely environmental loading via irrigation ditches examined in this study helps identify the pathway of veterinary antibiotics residuals in the environment.

Simultaneous Determination of Paeoniflorin and Glycyrrhizin in Sayuk-san by HPLC/DAD

  • Lee, Mi-Kyeong;Lee, Ki-Yong;Kim, Seung-Hyun;Jeon, Min-Ji;Cho, Jung-Hee;Oh, Mi-Hyun;Baek, Ju-Hyun;Kim, Hyo-Jin;Sung, Sang-Hyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.1
    • /
    • pp.23-27
    • /
    • 2009
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of marker constituents, paeoniflorin and glycyrrhizin was established for the quality control of traditional herbal medicinal preparation, Sayuk-san (SYS). Separation and quantification were successfully achieved with a Waters XTerra RP18 column ($5{\mu}m$, $4.6mm\;I.D.{\times}150mm$) by gradient elution of a mixture of acetonitrile and water containing 0.03% phosphoric acid (pH 2.03) at a flow rate of 1.0 mL/min. The diode-array UV/vis detector (DAD) was used for the detection and the wavelength for quantification was set at 230 nm. The presence of paeoniflorin and glycyrrhizin in this decoction was ascertained by retention time, spiking with each authentic standard and UV spectrum. All two compounds showed good linearity ($r^2$>0.996) in a relatively wide concentration ranges. The R.S.D. for intra-day and inter-day precision was less than 7.3% and the limits of detection (LOD) were less than 55.7 ng. The mean recovery of each compound was $102.3{\sim}111.1%$ with R.S.D. values less than 4.6%. This method was successfully applied to the determination of contents of paeoniflorin and glycyrrhizin in three commercial products of SYS. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial SYS products.

Combustion Characteristics of Fuel-rich Gas Generator with Impinging Injector for a Liquid Rocket Engine (액체로켓엔진에서 충돌형 분사기 형태의 연료과잉 가스발생기 연소특성)

  • Han, Yeoung-Min;Kim, Seung-Han;Lee, Kwang-Jin;Moon, Il-Yoon;Seol, Woo-Seok;Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.6
    • /
    • pp.64-70
    • /
    • 2005
  • The overall results of hot firing tests of fuel-rich gas generator with impinging injector at design and off-design points are described. The gas generator consists of an injector head with impinging injector, a water cooled combustor wall, a turbulence ring to enhance mixing, an instrument ring measuring temperature and pressure and a nozzle. The combustion tests were successfully performed without damage of gas generator. Test results show that the outlet temperature is not dependent on residence time of hot gas within 4~6msec but dependent on chamber pressure. The relation between outlet temperature and combustion efficiency resulting from measured pressure, mass flow rate and area of nozzle throat is shown. The overall O/F ratio is the critical parameter to determine the outlet temperature and the linear correlation between two parameters is established.

Antioxidant and Cytoprotective Activity of the Olive Leaf (Olea europaea L. var. Kalamata) Extracts on the Mouse Embryonic Fibroblast Cell

  • Ha, Ju-Yeon;Goo, Sun-Young;Sung, Jung-Suk;Shin, Han-Seung
    • Food Science and Biotechnology
    • /
    • v.18 no.4
    • /
    • pp.965-970
    • /
    • 2009
  • Oleuropein content of olive leaf extracts (OLE; ethanol extract) was evaluated by high performance liquid chromatography analysis. Oleuropein contents were $4.21{\pm}0.57$, $3.92{\pm}0.43$, $0.32{\pm}0.03$, $5.76{\pm}0.32$, and $32.47{\pm}0.25$ mg/100 g for ethanol extract, and hexane, chloroform, ethyl acetate, and butanol fraction, respectively. The removal of DPPH free radical increased in OLE and all 5 fractions of OLE in a concentration dependent manner. In order to investigate the antioxidant effect of OLE in vitro, 80%(v/v) ethanol OLE, $H_2O_2$, or combined treatment of 80%(v/v) ethanol OLE and $H_2O_2$ were applied on mouse embryonic fibroblast (MEF) cells. Cells were damaged by oxidative stress decreased their viability followed by increasing concentration of $H_2O_2$, but co-treatment of OLE and $H_2O_2$ showed an increase in cell growth about 20% compare to the cells treated with $H_2O_2$. OLE suppresses cytotoxicity induced by $H_2O_2$ in dose dependent manner. OLE treatment on MEF cells was also examined by analyzing cell cycle and apoptotic rate using flow cytometry. Apoptotic and necrotic cell accumulation was decreased in addition of OLE to $H_2O_2$ compare to the oxidative damaged cells. Taken together, these results demonstrated that OLE suppresses cytotoxicity induced by $H_2O_2$ and protect cells against oxidative stress on MEF cells.

Modeling and validation of a parabolic solar collector with a heat pipe absorber

  • Ismail, Kamal A.R.;Zanardi, Mauricio A.;Lino, Fatima A.M.
    • Advances in Energy Research
    • /
    • v.4 no.4
    • /
    • pp.299-323
    • /
    • 2016
  • Cylindrical parabolic solar concentrators of small concentration ratio are attractive options for working temperatures around $120^{\circ}C$. The heat gained can be utilized in many applications such as air conditioning, space heating, heating water and many others. These collectors can be easily manufactured and do not need to track the sun continuously. Using a heat pipe as a solar absorber makes the system more compact and easy to install. This study is devoted to modeling a system of cylindrical parabolic solar concentrators of small concentration ratio (around 5) fitted with a heat pipe absorber with a porous wick. The heat pipe is surrounded by evacuated glass tube to reduce thermal losses from the heat pipe. The liquid and vapor flow equations, energy equation, the internal and external boundary conditions were taken into consideration. The system of equations was solved and the numerical results were validated against available experimental and numerical results. The validated heat pipe model was inserted in an evacuated transparent glass tube as the absorber of the cylindrical parabolic collector. A calculation procedure was developed for the system, a computer program was developed and tested and numerical simulations were realized for the whole system. An experimental solar collector of small concentration, fitted with evacuated tube heat pipe absorber was constructed and instrumented. Experiments were realized with the concentrator axis along the E-W direction. Results of the instantaneous efficiency and heat gain were compared with numerical simulations realized under the same conditions and reasonably good agreement was found.