• Title/Summary/Keyword: liquid flow

Search Result 2,932, Processing Time 0.032 seconds

Finite Element Analysis for Forming Process of Semi-Solid Material Considering Induction Heating (유도가열을 고려한 반용융 재료의 성형공정에 관한 유한요소 해석)

  • Park, W.D.;Ko, D.C.;Kim, B.M.;Park, J.C.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.8
    • /
    • pp.82-91
    • /
    • 1997
  • The major objective of this study is to establish analytical technique in order to analyze the behaviour of semi-solid material considering induction heating of the billet. Induction heating process is analyzed by using commerical finite element software. ANSYS. The finite element program, SFAC2D, for the simulation of deformation in semi-solid state is developed in the present study. The semi-solid behaviour is described by a viscoplastic model for the solid phase, and by the Darcy's law for the liquid flow. Simple compression and closed-die compression process considering induction heating are analyzed, and also it is found that the distribution of initial solid fraction of the billet has an important effect on deformation behaviour of semi-solid material. In order to verify the effectiveness of proposed analytical technique the simulation result is compared with experimental result.

  • PDF

Effect of Refrigerant Pipe Length on Sea Water Cooling System Performance (해수냉각시스템 성능에 미치는 냉매배관길이의 영향)

  • Yun, Jeong-In;Jo, Yeong-Je
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.3
    • /
    • pp.346-351
    • /
    • 1998
  • The purpose of this study is analyzing the performance of sea water cooling system under various refrigerant pipe length. In sea water cooling system, the increase of refrigerant pipe length cause increases of pressure drops. These pressure drops cause fresh gas in liquid pipe and increase specific volume in gas pipe outlet, so sea water cooling system capacity is decreased by decrease of refrigerant mass flow rate. Sea water cooling system capacity in refrigerant pipe length 70m is decreased more than 30% when compared with pipe length 10m and the decrease of the coefficient of performance is nearly 20%.

  • PDF

Structural Characteristic of One Dimensional Single Crystalline of InN Nanowires (1차원 InN 단결정 나노선의 구조특성에 대한 고찰)

  • Byeun, Yun-Ki;Chung, Yong-Keun;Lee, Sang-Hoon;Choi, Sung-Churl
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.4 s.299
    • /
    • pp.202-207
    • /
    • 2007
  • High-Quality 1-Dimensional InN single crystalline have been grown by Halide Vapor-Phase Epitaxy on the Au catalyst coated Si substrate using the vapor-liquid-solid growth mechanism. We have been grown 1-dimension InN nanowires having controlled the growth conditions for substrate temperature and gases flow rate. The grown InN nanowire of characteristics for morphologies, crystal structure, and element analysis were carried out by SEM, HR-TEM, and EDS respectively. And the defects of InN crystalline were analyzed by indexing of selective area diffraction pattern with attached HR-TEM. We have successfully obtained the defect-free 1-dimensional InN single crystalline nanowire at the atmosphere pressure.

Fault Detection and Diagnosis of the Deaerator System in Nuclear Power Plants (원전 탈기기 시스템의 수위 측정 센서의 고장 검출 및 진단)

  • Kim, Bong-Seok;Lee, In-Soo;Lee, Yoon-Joon;Kim, Kyung-Youn
    • Journal of IKEEE
    • /
    • v.7 no.1 s.12
    • /
    • pp.107-118
    • /
    • 2003
  • In this paper, dynamic control model is formulated by considering the geometrical structure of the deaerator storage tank in nuclear power plant and input-output flow rate at steady state, and we describe fault detection and diagnosis (FDD) scheme based on the adaptive estimator. The performance and effectiveness of the proposed FDD scheme are evaluated by applying real operating data obtained from the YOUNGKWANG 3 & 4 FSAR.

  • PDF

A Study on Saccharides in Honey via HPLC (HPLC에 의한 벌꿀의 당성분에 관한 연구)

  • 김완구;정희선
    • Journal of Environmental Health Sciences
    • /
    • v.8 no.2
    • /
    • pp.57-65
    • /
    • 1982
  • Saccharides in Korean honey have been analyzed by traditional wet chemical methods and several chromatographic technics gas, paper, column and thin layer chromatography. A simple, rapid and versatile method for the separation and determination of saccharides via high performance liquid chromatography were used eluting with $H_2O : CH_CN$ at 25:75, at a flow rate of 1.0ml/min. Acasia honey contained 36.8% fructose, 31.4% glucose, 1.7% sucrose and bush clover honey held 34.4% fructose, 32.3% glucose and 30% sucrose. Difference on the regional distribution were not found in the quantity of saccharides (42 species). The quality of inferior honey was assumed to contain much maltose, sugar and glucose than common honey.

  • PDF

Approximated Solution of Model for Three-Phase Fluidized Bed Biofilm Reactor in Wastewater Treatment

  • Choi Jeong-Woo;Min Junhong;Lee Won-Hong;Lee Sang Baek
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.1
    • /
    • pp.65-70
    • /
    • 2000
  • An approximated analytical solution of mathematical model for the three phase fluidized bed bioreactor (TFBBR) was proposed using the linearization technique to describe oxygen utilization rate in wastewater treatment. The validation of the model was done in comparison with the experimental results. Satisfactory agreement was obtained in the comparison of approximated analytical solution and numerical solution in the oxygen concentration profile of a TFBBR. The approximated solutions for three modes of the liquid phase flow were compared. The proposed model was able to predict the biomass concentration, dissolved oxygen concentration the height of efficient column, and the removal efficiency.

  • PDF

Performance of Fire Extinguishing of Water Mist Nozzle for Power Transformer Fire Scenario (주 변압기실 화재시나리오에 적용한 미세물분무 노즐의 소화성능)

  • Lee, Kyoung-Duck
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.6 s.78
    • /
    • pp.46-54
    • /
    • 2006
  • Fire extinguishing experiment was conducted with water mist nozzle in case of the pool fire, cascade fire and spray fire on flammable liquid of class B whether water mist system can be effective system for power transformer fire scenario. In the event of a pool fire, flow rate and time to extinguish was inclined to be increased according to the obstruction rate of ignition space. Furthermore, the performance of fire extinguishing depended upon the spraying angle of the nozzles. In case of cascade fire, the effect of extinguishment was began to show from a combustion pan filled with fuel and fuel flowing plate later on.

Numerical Study of Droplet Motion in a Microchannel with defferent contact angles (접촉각에 따른 마이크로채널 내에서의 액적 거동에 대한 수치적 연구)

  • Choi, Ji-Young;Son, Gi-Hun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.656-657
    • /
    • 2008
  • The droplet dynamics in a hydrophilic/hydrophobic microchannel, which is applicable to a typical proton exchange membrane fuel cell (PEMFC), is studied numerically by solving the equations governing conservation of mass and momentum. The liquid-gas interface or droplet shape is determined by a level set method which is modified to treat contact angles. The matching conditions at the interface are accurately imposed by incorporating the ghost fluid approach based on a sharp-interface representation. The effects of contact angle, inlet flow velocity, droplet size and side wall on the droplet motion are investigated parametrically. Based on the numerical results, the droplet dynamics including the sliding and detachment of droplets is found to depend significantly on the contact angle. Also, a droplet removal process is demonstrated on the combination of hydrophilic and hydrophobic surfaces.

  • PDF

The Development of a Heat Balance Evaluation Program for the Main Steam Line of LNG Carrier (LNG선 주증기계통의 열평형산전용 전산프로그램 개발)

  • 최순호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.854-861
    • /
    • 1998
  • The demand of LNG as a cheap and clean energy which does not cause an environmental problem has sharply been increased in Korea. In general LNG is stored in a cargo tank specially designed as a liquid state below $-162^{\circ}C$. The main engine of a LNG carrier is generally a steam boiler because LNG is a highly flammable fluid with the possibility of explosion. The main engine of a cargo ship has to be capable of the propulsion load and various auxiliary loads for the safe navigation since it is the primary energy source. Therefore the evaluation of a main boiler's energy capacity is a key design point in the planning of LNG carrier's construction. This research is to develop the computational program for the analysis of steam boiler Heat balance for LNG carrier.

  • PDF

Effect of Boundary Slip Phenomena in Nanoimprint Lithography Process (나노임프린트 리소그래피 공정에서 Slip에 의한 경계 효과)

  • Lee, Young-Hoon;Kim, Nam-Woong;Sin, Hyo-Chol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.18 no.2
    • /
    • pp.144-153
    • /
    • 2009
  • It is widely known that no-slip assumptions are often violated on regular basis in micrometer- or nanometer-scale fluid flow. In the case of cavity-filling process of nanoimprint lithography(NIL), slip phenomena take place naturally at the solid-to-liquid boundaries, that is, at the mold-to-polymer or polymer-to-substrate boundaries. If the slip or partial slip phenomena are promoted at the boundaries, the processing time of NIL, especially of thermal-NIL which consumes more tact time than that of UV-NIL, can be significantly improved. In this paper it is aimed to elucidate how the cavity-filling process of NIL can be influenced by the slip phenomena at boundaries and to what degree those phenomena increase the process rate. To do so, computational fluid dynamics(CFD) analysis of cavity filling process has been carried out. Also, the effect of mold pattern shape and initial thickness of polymer resist were considered in the analysis, as well.