• Title/Summary/Keyword: liquid chromatography mass spectrometry

Search Result 888, Processing Time 0.027 seconds

Multichannel Liquid Phase Microextraction System (다채널 액상 미세 추출 시스템 설계 및 제작)

  • Zhang, XinJie;Cheng, Shuo;Piao, Xiang Fan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.10
    • /
    • pp.1-7
    • /
    • 2020
  • In this study, a multichannel gas-liquid microextraction system is designed by integrating the automatic elution of extraction line and multichannel gas-purging liquid phase microextraction. The system uses an injection pump and inert gas to push the extraction solvent to a sample bottle of a gas-phase color autosampler and then implements multichannel gas-liquid microextraction and gas chromatography-mass spectrometry. The system also employs a three-way integrated micro-high-temperature heater, syringe pump, and microflow controller to realize the simultaneous processing of multiple groups of samples, thus improving the sample pretreatment speed and reproducibility and reducing human error. Autoinjection experiments were implemented with polycyclic aromatic hydrocarbon standard samples. The experiments show that the average recovery rate of the system exceeds 70%, and the relative standard among the channels is less than 15%.

A Simple and Efficient Method to Determine Rivaroxaban in Rat Plasma Using Liquid-Liquid Extraction and LC-MRM

  • Lee, Hyo Chun;Kim, Dong Yoon;Choi, Min-Jong;Jin, Sung Giu;Choi, Yong Seok
    • Mass Spectrometry Letters
    • /
    • v.10 no.2
    • /
    • pp.66-70
    • /
    • 2019
  • Rivaroxaban (RRN) is the first available active direct factor Xa inhibitor (anticoagulant) with oral administration. Due to its success in market, there have been efforts to develop various RRN formulations, and the development of good analytical methods for its in vivo evaluation is an essential prerequisite. Thus, here, a simple and efficient method to determine RRN in rat plasma using liquid-liquid extraction (LLE) and liquid chromatography and multiple reaction monitoring (LC-MRM) was presented. The use of ethyl acetate as the LLE solvent results appropriate extraction and purification of RRN and it also helps the significant reduction of rat plasma volume required for RRN quantitation. The developed method showed good analytical performance including specificity, linearity ($r^2{\geq}0.999$ within 0.5 - 500 ng/mL), sensitivity (the lower limit of quantitation at 0.5 ng/mL), accuracy (89.3 - 107.0%), precision (${\geq}12.7%$), and recovery (89.2 - 105.7%). Additionally, RRN in sample extracts showed good stability. Finally, the applicability of the validated method to the PK evaluation of RRN was confirmed after its oral administration to normal rats. The present method is the first analytical method employing LLE for the simple and efficient extraction and purification of RRN in rat plasma. Therefore, the present method can contribute to the development of new RRN formulations as well as to the monitoring of RRN in special clinical situations through its efficient determination in various samples with or without minor modification.

Quantitative Analysis of Eleutherosides B and E Using HPLC-ESI/MS (HPLC-ESI/MS를 이용한 Eleutheroside B와 E의 정량)

  • Choi, Young-Hae;Kim, Jin-Woong
    • Korean Journal of Pharmacognosy
    • /
    • v.33 no.2 s.129
    • /
    • pp.88-91
    • /
    • 2002
  • Liquid-chromatography coupled with electrospray-ion trap mass spectrometry was applied to the analysis of the eleutherosides B and E in the Eleutherococcus senticosus cortexes. The optimum ESI/MS results were obtained in the positive ion mode using extracted ion chromatogram targeting Na-adduct molecular ion of each compound. This method allowed rapid and simple gradient separation of underivatized eleutherosides B and E without pre-purification steps at very low concentration.

Stability of 13C-urea/PEG capsules by LC-APCI-MS

  • Kim, Kyoung-Soon;Park, You-Mie;Lee, Sang-Hyun;Moon, Dong-Cheul;Kim, Bak-Kwang
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.280.2-280.2
    • /
    • 2003
  • The applicability of liquid chromatography-atmospheric-pressure chemical-ionization mass spectrometry (LC-APCI-MS) for the determination of 13C-urea in 13C-urea/PEG capsules has been studied. It is essential to assess the stability of a newly developed low-dose (38 mg) 13C-urea/PEG capsule. which will be used for 13C-urea breath test (13C-UBT) to detect Helicobacter pylori infection. (omitted)

  • PDF

Determination of nucleosides in human urine by high-performance liquid chromatography with electrospray ionization mass spectrometry(LC/ESI-MS)

  • Lee, Sang-Hee;Jung, Byung-Hwa;Kim, Sun-Yeou;Kim, Ho-Cheol;Chung, Bong-Chul
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.290.1-290.1
    • /
    • 2003
  • Oxidative DNA damage has been associated with many disease. Quantation of DNA adducts is considered to be a useful biomarker of oxidative DNA damage because its formation can also be induced by oxidative stress. Extensive efforts have been taken to identify the analytical methods for minimizing the artifactual formation of oxidative DNA damage. We have done direct analysis of DNA adducts using LC/ESI-MS without urine sample extraction. (omitted)

  • PDF

Production and Characterization of a New ${\alpha}$-Glucosidase Inhibitory Peptide from Aspergillus oryzae N159-1

  • Kang, Min-Gu;Yi, Sung-Hun;Lee, Jong-Soo
    • Mycobiology
    • /
    • v.41 no.3
    • /
    • pp.149-154
    • /
    • 2013
  • An ${\alpha}$-glucosidase inhibitor was developed from Aspergillus oryzae N159-1, which was screened from traditional fermented Korean foods. The intracellular concentration of the inhibitor reached its highest level when the fungus was cultured in tryptic soy broth medium at $27^{\circ}C$ for five days. The inhibitor was purified using a series of purification steps involving ultrafiltration, Sephadex G-25 gel permeation chromatography, strong cation exchange solid phase extraction, reverse-phase high performance liquid chromatography, and size exclusion chromatography. The final yield of the purification was 1.9%. Results of the liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis indicated that the purified ${\alpha}$-glucosidase inhibitor was a tri-peptide, Pro-Phe-Pro, with the molecular weight of 360.1 Da. The IC50 value of the peptide against ${\alpha}$-glucosidase activity was 3.1 mg/mL. Using Lineweaver-Burk plot analysis, the inhibition pattern indicated that the inhibitor acts as a mixed type inhibitor.

Expression of Antihypertensive Peptide, His-His-Leu, as Tandem Repeats in Escherichia coli

  • Jeong, Do-Won;Shin, Dong-Seok;Ahn, Chang-Won;Song, In-Sang;Lee, Hyong-Joo
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.6
    • /
    • pp.952-959
    • /
    • 2007
  • His-His-Leu (HHL), a tripeptide derived from a Korean soybean paste, is an angiotensin-I-converting enzyme (ACE) inhibitor. We report here a method of producing this tripeptide efficiently by expressing tandem multimers of the codons encoding the peptide in E. coli and purifying the HHL after hydrolysis of the peptide multimers. The HHL gene, tandemly multimerized to a 40-mer, was ligated with ubiquitin as a fusion gene (UH40). UH40 was inserted into vector pET29b; the UH40 fusion protein was then produced in E. coli BL21. The recombinant UH40 protein was purified by cation-exchange chromatography with a yield of 17.3mg/l and analyzed by matrixassisted laser desorption ionization (MALDI) time-of-flight (TOF) mass spectrometry and protein N-terminal sequencing. Leucine aminopeptidase was used to cleave a 405-Da HHL monomer from the UH40 fusion protein and the peptide was purified using reverse-phase high-performance liquid chromatography (HPLC) on a C18 HPLC column, with a final yield of 6.2mg/l. The resulting peptide was confirmed to be HHL with the aid of MALDI-TOF mass spectrometry, glutamine-TOF mass spectrometry, N-terminal sequencing, and measurement of ACE inhibiting activity. These results suggest that our production method is useful for obtaining a large quantity of recombinant HHL for functional antihypertensive peptide studies.