• Title/Summary/Keyword: linewidth

Search Result 206, Processing Time 0.022 seconds

Variations of the Linewidth Enhancement Factor of Strained MQW DFB Laser with Output Power (Strained MQW DFB 레이저의 광출력에 따른 Linewidth Enhancement Factor의 변화)

  • 오윤경;곽계달
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.6
    • /
    • pp.15-20
    • /
    • 1998
  • The linewidth enhancement factor $\alpha$ and fiber dispersion of 1.55 ${\mu}{\textrm}{m}$ strained multi-quantum well laser diodes are measured using small signal power modulation transfer function in a dispersive fiber. The measured fiber dispersion values are between 16.766 and 16.786ps/nm/km and these are the expected values from standard single mode fiber. To measure the $\alpha$ parameter in the actual operational range of the laser diodes, the dependence of $\alpha$ on laser output power is measured. The $\alpha$ parameter increases linearly as the power of the laser diode increases. This result can explain the non-linear gain effect on the $\alpha$ parameter more accurately than any other measurements.

  • PDF

3.2-kW 9.7-GHz Polarization-maintaining Narrow-linewidth All-fiber Amplifier

  • Hang Liu;Yujun Feng;Xiaobo Yang;Yao Wang;Hongming Yu;Jue Wang;Wanjing Peng;Yanshan Wang;Yinhong Sun;Yi Ma;Qingsong Gao;Chun Tang
    • Current Optics and Photonics
    • /
    • v.8 no.1
    • /
    • pp.65-71
    • /
    • 2024
  • We present a Yb-doped narrow-linewidth polarization-maintaining all-fiber amplifier that achieves a high mode-instability (MI) threshold, high output power, and 9.7-GHz spectral linewidth. Six wavelength-multiplexed laser diodes are used to pump this amplifier. First, we construct a high-power fiber amplifier based on a master oscillator-power amplifier configuration for experiments. Subsequently, we examine the MI threshold by individually pumping the amplifier with wavelengths of 976, 974, 981, 974, and 981 nm respectively. The experimental results demonstrate that the amplifier exhibits a high MI threshold (>3.5 kW) when pumped with a combination of wavelengths at 974 and 981 nm. Afterward, we inject an optimized phase-modulated seed with a nearly flat-top spectrum into this amplifier. Ultimately, laser output of 3.2 kW and 9.7 GHz are obtained.

The Study on the control of Pattern Linewidth for the Step and Repeat Projection Imaging (스텝 엔드 리피트 설영로광방식의 미세형상 선폭조절에 관한 연구)

  • 황영모;한맥형
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.4
    • /
    • pp.39-43
    • /
    • 1985
  • The charcterization of optical lithography on the step and repeat projection system is studied. Parameters that influence optical lithography were analyzed and the experiment was performed on the mask of $\pm$ 5rm, the surface flatness. From the experiment, the relationship between linewidth diviation on defocus and linewidth shift on exposure of the small features is obtained. Conditions maintaining good uniformity of small features from these relation-ships is presented.

  • PDF

Magnetic Properties of La-doped YIG Films Prepared by LPE(Liquid Phase Epitaxy) (LPE 성장법으로 성장시킨 La을 첨가한 YIG 막의 자성특성)

  • 김동영;한진우;김명수;이상석
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.3
    • /
    • pp.257-262
    • /
    • 2001
  • Single crystalline films of La doped YIG(yttrium iron garnet) were grown by the liquid phase epitaxy. The lattice constants of films obtained by DCD(double crystalline diffractometer) measurement increased with increasing La contents in films. In particular, lattice constants of films grown wiht Y/La=20 solution were nearly same as those of GGG (gadolinium gallium garnet) substrate. The saturation magnetization measured with VSM (vibrating sample magnetometer) was about 1750Gauss which is the same as that of pure YIG irrespective of La contents in films. FMR(ferromagnetic resonance) linewidth of La doped YIG was smaller than that of pure YIG. Since appropriate La doping decreases the lattice mismatch between film and substrate, the FMR linewidth was Y/La=20 in this experiment.

  • PDF

Measurement of Effective Linewidth for Ca-Zr Substituted YIG (Ca-Zr치환 YIG의 유효 선폭 측정)

  • 김약연;한진우;한기평;김덕준;이상석;최태구
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • The effective linewidth was measured using the conventional cavity perturbation method at 9.43 GHz in room temperature for Ca-Zr substituted yttrium iron garnet plate. The experimental set-up consists of the network analyzer, the electromagnet and the cylimdrical TE001 cavity. Measurement was performed in the static magnetic field perpendicular to the sample plane. The real and imaginary parts of diagonal component of the microwave susceptibility tensor are obtained from the resonance frequency and the quality factor Q of the cavity. Variations of the effective linewidth was qualitatively explained with the spin wave scattering theory.

  • PDF

Complex Permittivity and Linewidth Measurements of Microwave Ferrites Using the Cavity Perturbation Method (공진기 섭동방법을 이용한 마이크로파 페라이트의 복소 유전율과 선폭 측정)

  • 엄동진;오호석;박동철;윤상원
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.4
    • /
    • pp.11-19
    • /
    • 1993
  • The complex permittivity and the linewidth of microwave ferrites are measured using the well known cavity perturbation method. The cavity perturbation method has been widely used for the measurement of complex permittivity and conductivity of low loss magnetic and dielectric materials at microwave frequencies. TT1-2000, TT73-2200, and G-113 samples ordered from Trans-Tech Inc, are tested. TE$_{103}$ and TE$_{106}$ rectangular waveguide cavities are fabricated and the ferrite sample of cylidrical rod and sphere shapes are prepared. The error between the measurement values and the supplier's data is less than 1 percent in case of $\varepsilon$’ and about 10 percent in case of linewidth ($\Delta$H). Worst case error analysis shows that our measured results are well within the error bound calculated from the accuracy specification of the measuring instruments.

  • PDF

Analysis of Ferromagnetic Resonance Linewidth in Ni Thin Film Fabricated by Electrodeposition Method (전기 도금법으로 제작한 Ni 박막의 강자성 공명 선폭 분석)

  • Kim, Dong Young;Yoon, Seok Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.2
    • /
    • pp.60-65
    • /
    • 2014
  • We obtained resonance field ($H_{res}$) and linewidth (${\Delta}H_{PP}$) from measured ferromagnetic resonance signal in the functions of polar angle (${\Theta}_H$) in Ni thin film of 240 nm thickness fabricated by electrodeposition method. The angular dependence of $H_{res}$ was well fitted with the calculated ones. We confirmed that the g-factor and effective demagnetization field were 2.18 and 445 emu/cc by the theoretical analysis of the resonance field, respectively. The angular dependence of ${\Delta}H_{PP}$ showed very large values at in-plane direction (${\Theta}_H=90^{\circ}$), which could not explained by the homogenous linewidth due to the Gilbert damping and inhomogeneous linewidth due to the angular variations and magnetization variations by the surface layer. Therefore, we considered the spin wave scattering (two magnon scattering) process in order to analyze the measured inhomogeneous linewidth, which was appeared in thicker film than the critical thickness of 50 nm. The defect medicated spin wave scattering played a key role in the electrodoposited Ni thin film of 240 nm thickness.

Single-Frequency $Er^{3+}$-Doped Fiber Ring Laser with 0.7 kHz Linewidth (0.7 kHz 선폭의 단일 주파수 어븀첨가 광섬유 레이저)

  • 이정찬;김명욱;전영민;김봉규;고성윤;이상배;김상국;최상삼;이상선
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1998.08a
    • /
    • pp.88-89
    • /
    • 1998
  • 0.7 kHz linewidth, single-frdquency operation was achieved in apolarization-maintaining Er3+-doped filber ring laser at 1547.7 nm with a compact strure using a filber bragg grating (FBG) and a circulator. The single-frequency operation optput power was 3 mW.

  • PDF