• Title/Summary/Keyword: lines detection

Search Result 578, Processing Time 0.024 seconds

Development of a Technique for Detection of Contact Wire Wear using High-Speed Camera (고속카메라를 이용한 전차선 마모 검측 영상처리 알고리즘 개발)

  • Park, Young;Cho, Yong-Hyeon;Cho, Chul-Jin;Kim, Won-Ha
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.8
    • /
    • pp.632-637
    • /
    • 2010
  • The measurement of contact wire wear in electric railways is one of the key test parameters to increase speed and maintain safety in electric railways. Wear caused by continuous interaction between pantographs and contact wires has a negative effect on current collection quality and severely damaged contact wires might cause hazardous accidents. This paper introduces a non-contact optical-based contact wire wear measuring system that will replace conventional wear detecting methods conducted by maintenance vehicles or workers. The system is implemented by high-speed cameras that can collect images of contact wires during vehicle operation, a laser used to create images profile of the contact wire surface, and a computer used to process the collected images. The proposed system is designed to assist maintenance of overhead contact lines by creating geometrically plotted images of contact wires to detect contact wire wear during operation on conventional lines or high-speed lines.

MAP kinase kinase kinase as a positive defense regulator in rice-blast fungus interactions

  • Kim, Jung-A;Jung, Young-Ho;Lee, Joo-Hee;Jwa, Nam-Soo
    • Proceedings of the Korean Society of Plant Pathology Conference
    • /
    • 2004.10a
    • /
    • pp.48-52
    • /
    • 2004
  • We have found the role of rice mitogen-activated protein kinase kinase kinase (MAPKKK), OsEDR1, as controling hypersensitive response (HR) and increased disease resistance to rice blast fungus Magnaporthe grisea. Generation of transgenic rice plants through introduction of the over-expression construct of OsEDR1 using Agrobacterium-mediated transformation results in lesion mimic phenotype. Up-regulation of defense mechanism was detected through detection of increased transcription level of rice PBZ1 and PR1a. Inoculation of rice blast fungus on the lesion mimic transgenic lines displayed significantly increased resistance. The disease symptoms were arrested like HR responses which are commonly detected in the incompatible interactions. High accumulation of phenolic compounds around developing lesions was detected under UV light. There was variation among transgenic lines on the timing of lesion progression as well as the lesion numbers on the rice leaves. Transgenic lines with few lesions also show increased resistance as well as equal amount of grain yields compared to that of wild type rice cultivar Nipponbare. This is the first report of the MAPKKK as a positive regulator molecule on defense mechanism through inducing HR-like cell death lesion mimic phenotype. The application of OsEDR1 is highly expected for the development of resistant cultivars against rice pathogens.

  • PDF

A Study on the Algorithm for Fault Discrimination in Transmission Lines Using Neural Network and the Variation of Fault Currents (신경회로망과 고장전류의 변화를 이용한 고장판별 알고리즘에 관한 연구)

  • Yeo, Sang-Min;Kim, Chul-Hwan;Choi, Myeon-Song;Song, Oh-Young
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.366-368
    • /
    • 2000
  • When faults occur in transmission lines, the classification of faults is very important. If the fault is HIF(High Impedance Fault), it cannot be detected or removed by conventional overcurrent relays (OCRs), and results in fire hazards and causes damages in electrical equipment or personal threat. The fast discrimination of fault needs to effective protection and treatment and is important problem for power system protection. This paper proposes the fault detection and discrimination algorithm for LIFs(Low Impedance Faults) and HIFs(High Impedance Faults). This algorithm uses artificial neural networks and variation of 3-phase maximum currents per period while faults. A double lines-to-ground and line-to-line faults can be detected using Neural Network. Also, the other faults can be detected using the value of variation of maximum current. Test results show that the proposed algorithms discriminate LIFs and HIFs accurately within a half cycle.

  • PDF

Height & Position Control of a Power Line Inspection Robot Using Various Sensors (다양한 센서를 이용한 배전선 점검 로봇의 높이 및 자세제어)

  • Han, Sun-Sin;Choi, Jae-Young;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.2
    • /
    • pp.169-175
    • /
    • 2009
  • A new wire detection algorithm for power line inspection by a mobile robot has been proposed in this paper. There have been a lot of studies in order to support the high-quality electric power. For the high-quality power supply, it is necessary to investigate the power lines and insulators before the lines or insulators were disconnected or damaged. Although Korea Electric power Corp. has made many efforts for the quality improvement, it is not enough to inspect all the power lines by human inspectors. According to this problem, it is decided to replace the human operators by the power line inspection robot. When the robots are used for the inspection, there could be several advantages, for example, the working efficiency and the prevention of accident. And also the shortage of human power for dangerous jobs can be resolved. In this paper, as a part of the development of power line inspection robot, DICRO, the sensor fusion and fuzzy control algorithms are developed to detect the wire and slope of the wire. The effectiveness of the proposed algorithms is proved by the real experiments with DICRO which is under development so far.

Design and Implementation of Wideband Microstrip Antenna with Resistive and Inductive Loading (저항성 및 유도성 부하를 가진 평판형 광대역 안테나의 설계 및 제작)

  • Jeon, Sang-Bong;Ahn, Chang-Hoi
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1111-1116
    • /
    • 2007
  • Antennas of the near field detection radar require little distortion in time domain caused by multi reflections between feed and open ends of the antenna, so that help to discriminate the target signal from the clutters. The resistive loading techniques have been used to reduce the late time distortions in order to prevent masking of target. In this paper, we design a microstrip antenna with two arms having sloted lines, which have inductance loading effect. Implemented antenna shows better performance on reducing late-time ringing, and the peak value of the received signal becomes 45% greater than the one by the antenna with two non-sloted lines.

Detection of Anticancer Activity from the Root of Angelica gigas In Vitro

  • Ahn, Kyung-Seop;Sim, Woong-Seop;Kim, Ik-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.5 no.2
    • /
    • pp.105-109
    • /
    • 1995
  • Anticancer activity of a fraction of the ethanol extract from the root of Korean angelica (Angelica gigas Nakai) was recognized in human cancer cell lines HeLa $S_3$, K-562, and Hep $G_2$. The extract blocked the phorbol ester-inducing megakaryocytic differentiation of K-562 cells, which indicated the modification of protein kinase C (PKC) activity. In vitro assay showed the activation of PKC by the extract. An effective fraction of the Angelica gigas extract, of which $R_f$ value was 0.64 in a thin layer chromatography, was a different component from those of European angelicas. The $ED_50$ value of the fraction was 8, 9, and $16\;\mu\textrm{m}/ml$ against HeLa $S_3\;Hep\;G_2$, and K-562 cells, respectively, while the fraction showed higher $ED_50$ values against normal cell lines.

  • PDF

A Study on Distance Relay of Transmission with UPFC Using Artificial Neural Network (신경회로망을 이용한 UPFC가 연계된 송전선로의 거리계전기에 관한 연구)

  • Park, Jeong-Ho;Jung, Chang-Ho;Shin, Dong-Joon;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.196-198
    • /
    • 2002
  • This paper represents a new approach for the protective relay of power transmission lines using a Artificial Neural Network(ANN). A different fault on transmission lines need to be detected, classified and located accurately and cleared as fast as possible. However, The protection range of the distance relay is always designed on the basis of fixed settings, and unfortunately these approach do not have the ability to adapt dynamically to the system operating condition. ANN is suitable for the adaptive relaying and the detection of complex faults. The backpropagation algorithm based multi-layer perceptron is utilized for the learning process. It allows to make control to various protection functions. As expected, the simulation result demonstrate that this approach is useful and satisfactory.

  • PDF

A Study on the Detection of Transient Fault and Permanent Fault in Transmission Lines Using Wavelet Transform (Wavelet 변환을 이용한 송전선로의 일시고장과 영구고장 검출에 관한 연구)

  • Cho, Seong-Bin;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1366-1368
    • /
    • 1999
  • With conventional single pole auto-reclosure (SPAR), unsuccessful reclosure using a fixed dead time in the case of transient fault, or reclosure onto a permanent fault. may aggravate the potential damage to the system and equipment. In this respect, the research is needed to implement SPAR effectively. In this paper, we present a wavelet transform approach to detect and discriminate between transient fault and permanent fault in transmission lines.

  • PDF

A Study on the Fault Detection and Discrimination of Transmission Line using Fault-generated high frequency signals (고주파를 이용한 송전선로의 사고 검출 및 판별에 관한 연구)

  • Lim, Byung-Ho;Kim, Chul-Hwan;Lee, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1376-1378
    • /
    • 1999
  • Most conventional protection relays are based on processing information in the spectrum that is close to or at power frequency. It is, however, widely known that faults on transmission lines produce frequency components of a wide range In this respect, this paper describes the basis of a Protection technique for transmission lines which utilises high-frequency components. Fault-generated signals caused by post-fault and the signal derived from stack tuner is connected to the coupling capacitor of CVT. Digital signal processing is then applied to the captured information to determine whether the fault is inside or outside the Protected zone, and to discriminate the fault type on transmission line.

  • PDF

The Response of QTL in Generation during Selection (선발과정에서의 세대별 QTL 좌위 고정에 관한 연구)

  • Lee Ji-Woong
    • Journal of Embryo Transfer
    • /
    • v.20 no.3
    • /
    • pp.217-232
    • /
    • 2005
  • The objective of this study was to determine the response of QTL in each generation during selection to develop inbred lines. The simulation program was written in Fortran. Magnitude of QTL effects, base population size, number of QTL assigned to population, and the allelic frequency for the positive allele at each major QTL were highly associated with number of generations to fixation of QTLs during selection. Populations with larger QTL effects and larger base population size had more individuals with fixed QTL. However, a smaller number of QTL assigned to population had a higher fraction of individuals with fixed QTL at each generation compared with more populations with QTL. This simulation study will help to design biological experiments for detection of QTL-marker association using inbred population and to determine optimum number of lines with fixed QTL during inbred line development. To complement this study, additional simulation should be need with abundant replicates, more various population sizes, magnitude of QTL effects, and recombination between markers and QTLs.