• 제목/요약/키워드: linearity test

검색결과 405건 처리시간 0.024초

DEVELOPMENT OF A REVERSE CONTINUOUS VARIABLE DAMPER FOR SEMI-ACTIVE SUSPENSION

  • Yoon, Young-Hwan;Choi, Myung-Jin;Kim, Kyung-Hoon
    • International Journal of Automotive Technology
    • /
    • 제3권1호
    • /
    • pp.27-32
    • /
    • 2002
  • Semi-active suspension systems are greatly expected to be in the mainstream of future controlled suspensions fur passenger cars. In this study, a continuous variable damper for a passenger car suspension is developed. It is controlled actively and exhibits high performance with light weight, low cost, and low energy consumption. To get fast response of the damper, reverse damping mechanism is adapted, and to get small pressure change rate after blow-off, a pilot controlled proportional valve is designed and analyzed. The reverse continuous variable damper is designed as a HS-SH damper which offers good body control with reduced transferred input force from tire, compared with any other type of suspension system. The damper structure is designed, so that rebound and compression damping force can be tuned independently, of which variable valve is placed externally. The rate of pressure change with respect to the flow rate after blow-offbecomes smooth when the fixed orifice size increases. Damping forces are measured with the change of the solenoid current at the different piston velocities to confirm the maximum hysteresis of 20N, linearity, and variance of damping farce. The damping farce variance is wide and continuous, and is controlled by the spoof opening, of which scheme is usually adapted in proportional valves. The reverse continuous variable damper developed in this study is expected to be utilized in the semi-active suspension systems in passenger cars after its performance and simplicity of the design is confirmed through real car test.

HPLC-tandem Mass Spectrometric Analysis of the Marker Compounds in Forsythiae Fructus and Multivariate Analysis

  • Cho, Hwang-Eui;Ahn, Su-Youn;Son, In-Seop;Hwang, Gyung-Hwa;Kim, Sun-Chun;Woo, Mi-Hee;Lee, Seung-Ho;Son, Jong-Keun;Hong, Jin-Tae;Moon, Dong-Cheul
    • Natural Product Sciences
    • /
    • 제17권2호
    • /
    • pp.147-159
    • /
    • 2011
  • A high-performance liquid chromatography-electrospray ionization-tandem mass spectrometric method was developed to determine simultaneously eight marker constituents of Forsythiae fructus, and subsequently applied it to classify its two botanical origins. The marker compounds of Forsythia suspensa were phillyrin, pinoresinol, phillygenin, lariciresinol and forsythiaside; those of F.viridissima were arctiin, arctigenin and matairesinol. Separation of the eight analytes was achieved on a phenyl-hexyl column (150${\times}$2.0 mm i.d., 3 ${\mu}M$) using gradient elution with the mobile phase: (A) 10% acetonitrile in 0.5% acetic acid, (B) 40% aqueous acetonitrile. A few fragment ions specific to the types of lignans, among the product ions generated by collisonally induced dissociation (CID) of molecular ion clusters, such as [M-H]$^-$ or [M+OAc]$^-$ were used not only for fingerprinting analysis but for the quantification of each epimer by using multiple-reaction monitoring mode. It was shown good linearity ($r^2{\geq}$ 0.9998) over the wide range of all analytes; intra- and inter-day precisions (RSD, %) were within 9.14% and the accuracy ranged from 84.3 to 115.1%. The analytical results of 40 drug samples, combined with multivariate statistical analyses - principal component analysis (PCA) and hierarchical cluster analysis (HCA) - clearly demonstrated the classification of the test samples according to their botanical origins. This method would provide a practical strategy for assessing the authenticity or quality of the herbal drug.

액체크로마토그래피를 이용한 벌꿀 중 테트라싸이클린계 항생물질의 정량분석 및 잔류조사 (Determination and survey of tetracyclines residue in honey by high performance liquid chromatography)

  • 이성모;박은정;홍지영;김정임;이정구;황현순;김용희
    • 한국동물위생학회지
    • /
    • 제28권3호
    • /
    • pp.203-213
    • /
    • 2005
  • Oxytetracycline, tetracycline, chlortetracycline and doxycycline in honey were separated by solid phase extraction (SPE) and determined with high performance liquid chromatography (HPLC) with UV/Visible detector. Analysis was carried out using following conditions: XTerra $C_8$ column $(3.9\times150mm\;i.d. 5{\mu}m)$, mobile phase composed of 0.01M oxalic acid : methanol : acetonitrile (820 : 80 : 100, v/v/v), isocratic pump at a flow rate of 0.9 ml/min. and $50{\mu}l$ of injection volume, UV/Visible detector with wavelength of 360nm. The calibration curves of four tetracyclines showed linearity $(\gamma^2>0.999)$ at concentration range of $100\~1,000 ng/ml$. The recoveries in fortified honey represented more than $70\%$ with low coefficient of variation $(<10\%)$ for concentration range of four tetracyclines. The detection limits for oxytetracycline, tetracycline, chlortetracycline and doxycycline were 13.8, 14.6, 26.2 and 24.9ng/g in acacia honey. respectively. We also monitored tetracyclines residue in domestic honey [n : 38, acacia (20), wild flower (18) ] and foreign honey [n=22, legally distributed (13), illegally distributed (9)] using modified Charm II screening and HPLC confirmation methods. Seven of the 60 samples $(11.7\%)$ were suspect positive using modified Charm II screening test. Chlortetracycline residue was found in one foreign honey (illegally distributed) tested at concentrations of 0.22 ppm. Conclusively, for more effective control of tetracyclines used in beekeeping should be further survey for residues in honey and also national guidelines (maximum residue limit : MRL) and methods should be obligatory.

형광 크로마토그래피에 의한 콜레스테롤 측정법의 개발 (Development of Total Cholesterol Detection System by Fluorescence Chromatography)

  • 오상욱
    • 한국식품위생안전성학회지
    • /
    • 제24권2호
    • /
    • pp.148-153
    • /
    • 2009
  • 본 연구에서는 심혈관계 질환의 표지인자인 콜레스테롤의 농도를 새롭게 개발한 형광 크로마토그라피 방법에 의하여 측정 하고자 시도하였다. 개발된 측정 시스템은 크로마토그라피 스트립이 들어 있는 카트리지, 발색제 AEC, 콜레스테롤 옥사데이즈 (Cholesterol Oxidase, CO), 콜레스테롤 에스트라아제(Cholesterol Esterase, CE), 호스래 디쉬페록시다아제 (Horseradish peroxidase, HRP)를 포함하는 효소혼합 수용액, 그리고 형광 판독기로 구성되어 었다. 콜레스테롤 농도 변화에 따른 형광 세기 변화로 얻은 상관계수 r= 0.968로 측정 가능한 농도 범위에서 신뢰할 만한 직선성 관계를 제시하여 주었다. 회복률과 Hitachi 747 검사기기와 비교 테스트에서는 각각 106.5-94%와 상관관계 r = 0.939 (p<0.001)로 비교적 높은 유의성을 보여주었다. 따라서 본 연구에서 개발된 새로운 콜레스테롤 농도 측정법은 빠른 반응 시간 (8분)과 적은 시료량 ($5\;{\mu}l$)을 사용하기에 시료를 실험실로 운반할 필요없이 클리닉에서 측정 가능한 준현장검사 플랫폼형으로 개발되었으며 기존의 고가의 자동화 장비를 사용하는 생화학적 진단방식 대체용으로의 응용이 기대된다.

디지털 방식의 인접면 접촉강도 측정장치의 개발 및 평가 (EVALUATION AND DEVELOPMENT OF DIGITAL DEVICE FOR MEASURING PROXIMAL TOOTH CONTACT TIGHTNESS)

  • 최우진;김경화;김진아;강동완;오상호
    • 대한치과보철학회지
    • /
    • 제45권5호
    • /
    • pp.687-695
    • /
    • 2007
  • Statement of problem: The proper contact relation between adjacent teeth in each arch plays an important role in the stability and maintenance of the integrity of the dental arches. Proximal contact has been defined as the area of a tooth that is in close association, connection, or touch with an adjacent tooth in the same arch. Purpose: The aim of this study was to develop a digital device for measuring the proximal tooth contact tightness by pulling a thin stainless steel strip (2mm wide, 0.03mm thick) inserted between proximal tooth contact. Material and method: This device consists of measuring part, sensor part, motor part and body part. The stainless steel strip was connected to a stain gauge. The strain gauge was designed to convert the frictional force into a compressive force. This compressive force was detected as a electrical signal and the electrical signal was digitalized by a A/D converter. The digital signals were displayed by a micro-processor. The pulling speed was 8mm/s. Results: For testing reliability of the device in vivo, two healthy young adults (A, B) participated in this experiment. The tightness of proximal tooth contact between the second premolar and the first molar of mandible (subject A) and maxilla (subject B) was measured fifteen times for three days at rest. We double-checked the accuracy of the device with a Universal Testing Machine. Output signals from the Universal Testing Machine and the measuring device were compared. Regression analysis showed high linearity between these two signals. In vivo test, no significant differences were found between measurements. Conclusion: This device has shown to he capable of producing reliable and reproducible results in measuring proximal tooth contact. Therefore, it was considered that this device was appropriate to apply clinically.

뉴로모픽 시스템용 시냅스 트랜지스터의 최근 연구 동향

  • 남재현;장혜연;김태현;조병진
    • 세라미스트
    • /
    • 제21권2호
    • /
    • pp.4-18
    • /
    • 2018
  • Lastly, neuromorphic computing chip has been extensively studied as the technology that directly mimics efficient calculation algorithm of human brain, enabling a next-generation intelligent hardware system with high speed and low power consumption. Three-terminal based synaptic transistor has relatively low integration density compared to the two-terminal type memristor, while its power consumption can be realized as being so low and its spike plasticity from synapse can be reliably implemented. Also, the strong electrical interaction between two or more synaptic spikes offers the advantage of more precise control of synaptic weights. In this review paper, the results of synaptic transistor mimicking synaptic behavior of the brain are classified according to the channel material, in order of silicon, organic semiconductor, oxide semiconductor, 1D CNT(carbon nanotube) and 2D van der Waals atomic layer present. At the same time, key technologies related to dielectrics and electrolytes introduced to express hysteresis and plasticity are discussed. In addition, we compared the essential electrical characteristics (EPSC, IPSC, PPF, STM, LTM, and STDP) required to implement synaptic transistors in common and the power consumption required for unit synapse operation. Generally, synaptic devices should be integrated with other peripheral circuits such as neurons. Demonstration of this neuromorphic system level needs the linearity of synapse resistance change, the symmetry between potentiation and depression, and multi-level resistance states. Finally, in order to be used as a practical neuromorphic applications, the long-term stability and reliability of the synapse device have to be essentially secured through the retention and the endurance cycling test related to the long-term memory characteristics.

국가 바이오모니터링 프로그램을 위한 소변 중 금속류 동시분석법 개발 및 검증 (Development and Validation of the Simultaneous Analytical Method of Urinary Metals and Metalloids for the National Biomonitoring Programs)

  • 조용민;양민호;임호섭;차상원;이재익;김기훈;한상범
    • 한국환경보건학회지
    • /
    • 제45권6호
    • /
    • pp.594-604
    • /
    • 2019
  • Objectives: This study developed and validated an analysis method of urinary metals and metalloids that can be applied inductively with coupled plasma mass spectrometry (ICP-MS). Methods: 0.3 mL of urine was used to analyze 25 metal and metalloid compounds using ICP-MS. The validation of the analytical method included linearity, accuracy, precision, and the calculation of detection limits. In addition, a comparison test was performed with the graphite furnace atomic absorption spectrometry (GF-AAS) method, which is the current standard method, with urine samples of 66 healthy subjects. Results: The linearities (R2) of calibration curves of all 25 compounds were ≥ 0.999. Of the 25 compounds, the intra-day and inter-day accuracy% of 17 and 20 met ≤15%, respectively. In addition, fifteen compounds showed ≤15% recovery% for certificated reference materials. Intraclass correlation coefficients of the comparison between the current methods and new methods in this study were 0.952 (p-value<0.001) and 0.911 (p-value<0.001) for urinary cadmium and mercury, respectively. Conclusion: This study proposes an efficient simultaneous methodology that can analyze multi elements in smaller sample amounts. More reproduction experiments are needed in the future.

YIG-VCO를 사용한 산업용 마이크로파 거리계의 개발 (Development of a Microwave Level Meter Using YIG-VCO for Industrial Process)

  • 김정목;임종수;전중창;김태수;안광호;이승학
    • 한국전자파학회논문지
    • /
    • 제11권1호
    • /
    • pp.18-25
    • /
    • 2000
  • 본 논문에서는 YIG 발진기(YTO)를 사용한 산업용 FM-CW 마이크로파 거리계를 설계 제작하여, 그 측정 겸과를 제시하였다.YTO는 주파수 선형성이 매우 우수하므로 거리계의 구성에서 별도의 선형화 장치를 필요로 하지 않는다. 운용환경 주변의 장애물로부터 발생되는 반사 선호를 제거하기 위해서 중간주파 선호에 디지털 대역통과 필터를 적용하였다. 이를 위해서 Kaiser window를 사용한 FIR 필터가 설계되었다. 거리 측정 테스트는 4 40m까지 측정할 수 있는 야외 시험장에서 1m 간격으로 실시되었으며, 측정오차의 표준편차가2.33 cm인 측정 결과플 얻었다 본 논문에서 제작된 마이크로파 거리계는 제철소의 용선 운반 차량과 같이 사람이 접근하기 어 려운 산업 시설에서 거리측정용으로 사용될 수 있다

  • PDF

Study on mapping of dark matter clustering from real space to redshift space

  • Zheng, Yi;Song, Yong-Seon
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.38.2-38.2
    • /
    • 2016
  • The mapping of dark matter clustering from real to redshift spaces introduces the anisotropic property to the measured density power spectrum in redshift space, known as the Redshift Space Distortion (hereafter RSD) effect. The mapping formula is intrinsically non-linear, which is complicated by the higher order polynomials due to the indefinite cross correlations between the density and velocity fields, and the Finger-of-God (hereafter FoG) effect due to the randomness of the peculiar velocity field. Furthermore, the rigorous test of this mapping formula is contaminated by the unknown non-linearity of the density and velocity fields, including their auto- and cross-correlations, for calculating which our theoretical calculation breaks down beyond some scales. Whilst the full higher order polynomials remains unknown, the other systematics can be controlled consistently within the same order truncation in the expansion of the mapping formula, as shown in this paper. The systematic due to the unknown non-linear density and velocity fields is removed by separately measuring all terms in the expansion using simulations. The uncertainty caused by the velocity randomness is controlled by splitting the FoG term into two pieces, 1) the non-local FoG term being independent of the separation vector between two different points, and 2) the local FoG term appearing as an indefinite polynomials which is expanded in the same order as all other perturbative polynomials. Using 100 realizations of simulations, we find that the best fitted non-local FoG function is Gaussian, with only one scale-independent free parameter, and that our new mapping formulation accurately reproduces the observed power spectrum in redshift space at the smallest scales by far, up to k ~ 0.3 h/Mpc, considering the resolution of future experiments.

  • PDF

감마선 검출용 $HgI_2$ 소자 제작 및 특성 평가 (Fabrication and Test of a $HgI_2$ Gamma Ray Detector)

  • 최명진;이홍규;강영일;임호진;최승기
    • Journal of Radiation Protection and Research
    • /
    • 제16권2호
    • /
    • pp.1-6
    • /
    • 1991
  • 상온에서 사용할 수 있는 감마선 검출 소자로서 $HgI_2$ 소자의 응용성을 판단하기 위하여 기상 성장법으로 $HgI_2$ 단결정을 성장시켰고 이를 이용하여 검출 소자를 제작한 후 감마선 검출 특성을 조사하였다 성장된 단결정의 비저항과 전하 운반자 포획 밀도는 상온에서 각각 $10^{11}{\Omega}\;cm$$1.8{\times}10^{14}/cm^3$였으며 단결정의 Photoluminescence를 측정한 결과 성장된 $HgI_2$ 단결정의 밴드갭의 온도계수는 20K부터 77K에서 $-1.53{\times}10^{-4}eV/K$였다. 감마선 검출실험 결과 제작된 $HgI_2$ 검출 소자는 상온에서 우수한 계수 특성과 시간에 대한 선형적 축적 계수 특성을 나타내었으나 온도변화에 따라 계수의 특성의 변화는 심하였다.

  • PDF