• 제목/요약/키워드: linear ultrasonic test

검색결과 38건 처리시간 0.028초

충격공진법 및 복합법을 이용한 콘크리트의 강도 평가 기법 (Evaluation Technique of Concrete Strength Using Impact-Resonance and Combined Method)

  • 이광명;이회근;김동수;김지상
    • 콘크리트학회논문집
    • /
    • 제11권4호
    • /
    • pp.157-167
    • /
    • 1999
  • Among several non-destructive testing methods, ultrasonic pulse velocity method and rebound index method have been widely used for the evaluation of concrete strength. However, such methods might not provide accurate estimated results since factors influencing the relationship between strength and either ultrasonic pulse velocity or rebound index are not considered. In this paper, the evaluation method of concrete strength using rod-wave velocity measured by impact-resonance method is proposed. A basic equation is obtained by the linear regression of velocity vs, strength data at specific age and then, aging factor is employed in the equation to consider the difference of the increasing rate between wave velocity and strength. Strengths predicted by the proposed equation agree well with test results. Furthermore, the combined method of rod-wave velocity and rebound index is proposed.

초음파 비파괴시험법을 이용한 데크재의 현장평가 (Ultrasonic Nondestructive On-Site Evaluation of Decks in-Service)

  • 오세창
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권4호
    • /
    • pp.486-493
    • /
    • 2015
  • 설치된 데크재에 대한 성능을 평가하기 위하여 초음파 비파괴시험법을 사용하였다. 먼저 3종류의 데크재에 대해 트랜스듀서의 배치에 따른 직접법과 간접법간의 측정방법간의 차이를 검증하였으며 두 번째로 설치된 데크재의 사용시간의 경과에 따른 초음파속도를 측정 비교하였다. 마지막으로 데크재의 사용수명을 파악하기 위하여 사용시간의 경과에 따른 초음파속도의 변화를 조사하였다. 시험결과 직접법과 간접법간의 측정방법간의 차이는 없는 것으로 나타났으며 직접법에 대한 간접법의 비율은 1.02와 1.05로 각각 나타났다. 설치된 데크재에서 시간의 경과에 따라 초음파 속도는 감소하였으며 이들 간의 관계는 선형으로 나타났다. 시험결과로부터 초음파 비파괴시험법은 설치된 데크재의 유지보수에 관한 효율적인 수단이 될 수 있을 것으로 생각된다.

초음파 세탁과 가정 세탁의 세척성과 직물변형 비교 (Comparison of Detergency and Fabric Deformation between Ultrasonic and Home Laundry)

  • 황나원;정혜원;이광우
    • 한국의류산업학회지
    • /
    • 제25권3호
    • /
    • pp.386-397
    • /
    • 2023
  • In this study, the efficacy of ultrasonic washing in cotton and wool fabrics was compared and evaluated against conventional washing in terms of cleaning properties and fabric deformation. Factors such as washing temperature, time, liquid ratio, and detergent concentration were kept varied, and the cleaning properties of sebum-soiled fabrics were assessed using different detergents such as alcohol ethoxylate, linear alkylbenzenesulfonate, and IEC 60456 Reference Detergent A*. In addition, the effects and emulsification power of enzymes and oxygen bleach were examined. To compare the cleaning properties with general washing, a launder-O-meter was used. To investigate fabric deformation during the washing process, the loosening test cloth, shrinkage test cloth, and mechanical strength test cloth were compared between ultrasonic washing machines and household drum washing machines. The results indicate that ultrasonic washing exhibits superior cleaning properties than launder-O-meter when the temperature is low and the washing time is short. Furthermore, there is less deformation and damage during the washing process. It was also observed that the activity of the detergent increases when ultrasonic waves are applied to the washing process. Considering the increasing tendency to pursue convenience and simplicity in clothing management as well as the anticipated commercialization of smart clothing with built-in electric circuits, ultrasonic laundry could serve as a new alternative to existing laundry methods.

자왜재료를 이용한 선형 작동기의 유한요소 해석 (Finite Element Analysis of Magnetostrictive Linear Actuator)

  • 김윤창;김재환
    • 한국소음진동공학회논문집
    • /
    • 제17권4호
    • /
    • pp.356-362
    • /
    • 2007
  • Magnetostrictive materials have been used for linear actuators due to its large strain, large force output with moderate frequency band in the presence of magnetic field. However their performance analysis is difficult because of nonlinear material behaviors in terms of coupled strain-magnetic field dependence, nonlinear permeability, pre-stress dependence and hysteresis. This paper presents a finite element analysis technique for magnetostrictive linear actuator. To deal with coupled problems and nonlinear behaviors, a simple finite element approach is proposed, which is based on separate magnetic field calculation and displacement simulation. The finite element formulation and an in-house program development are illustrated, and a simulation model is made for a magnetostrictive linear actuator. The fabrication and performance test of the linear actuator are explained, and the performance comparison with simulation result is shown. Since this approach is simple, it can be applied for analyzing magnetostrictive underwater projectors and ultrasonic transducers.

탄소섬유복합평판에 낙추충격을 가할 때 적층구성에 미치는 영향에 관한 연구 (A Study on the Influence of Stacking Sequences using CFRP Laminate Plates by Falling Weight Impact)

  • 임광희;박노식;양인영
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 추계학술발표대회 논문집
    • /
    • pp.106-109
    • /
    • 2000
  • Impact tester was build up to evaluate the characterization of CFRP laminate plates under the low velocity impact. The tests were conducted on several laminates of different ply orientation A system was budded for the impact strength of CFRP laminates in consideration of stress wave propagation theory using drop-weight impact tester as one of impact test. Results indicate that absorbed energy of quasi-isotropic specimen having four interfaces is higher than that of orthotropic laminates with two interfaces. Also the damage area was measured with ultrasonic C-scanner on some samples. In the specimens the relationship was linear between damaged area and absorbed energy to some degree. Absorbed energy in the specimen that ply number, interface number and fiber stacking sequences is same but having hybrid is higher than that of orthotropic laminates without hybrid.

  • PDF

Effect of ultrasonic tip designs on intraradicular post removal

  • Aguiar, Anny Carine Barros;de Meireles, Daniely Amorim;Marques, Andre Augusto Franco;Sponchiado, Emilio Carlos Junior;Garrido, Angela Delfina Bitencourt;Garcia, Lucas Da Fonseca Roberti
    • Restorative Dentistry and Endodontics
    • /
    • 제39권4호
    • /
    • pp.265-269
    • /
    • 2014
  • Objectives: To evaluate the effect of different ultrasonic tip designs on intraradicular post removal. Materials and Methods: The crowns of forty human canine teeth were removed, and after biomechanical preparation and filling, the roots were embedded in acrylic resin blocks. The post spaces were made, and root canal molding was performed with self-cured acrylic resin. After casting (Cu-Al), the posts were cemented with zinc phosphate cement. The specimens were randomly separated into 4 groups (n = 10), as follows: G1 - no ultrasonic vibration (control); G2 - ultrasonic vibration using an elongated cylindrical-shaped and active rounded tip; G3 - ultrasonic vibration with a flattened convex and linear active tip; G4 - ultrasonic vibration with active semicircular tapered tip. Ultrasonic vibration was applied for 15 seconds on each post surface and tensile test was performed in a Universal Testing Machine (Instron 4444 - 1 mm/min). Results: G4 presented the highest mean values, however, with no statistically significant difference in comparison to G3 (p > 0.05). G2 presented the lowest mean values with statistically significant difference to G3 and G4 (p < 0.05). Conclusions: Ultrasonic vibration with elongated cylindrical-shaped and active rounded tip was most effective in reducing force required for intraradicular post removal.

위상차-주파수 다중 파라미터 조절에 의한 초음파 모터 속도 특성 (A Speed Characteristics of the Ultrasonic Motor by the Multi-Parameters adjustment with Phase difference-Frequency)

  • 김동옥;강원창;김성철;오금곤;김영동
    • 전기학회논문지P
    • /
    • 제52권1호
    • /
    • pp.20-27
    • /
    • 2003
  • In this study, we designed and made Ultrasonic motor-digital multi controller(USM-DMC) using FPGA chip, A54SX72A made in Actel Corporation. By the minute, USM-DMC can adjust the frequency, duty ratio, and phase difference parameters of USM by digital input to be each 11bit from PC. Therefore, when we use this controller, it is possible to apply typical three parameters individually as well as multi-parameters simultaneously to control the speed and the torque. What is more, the strongest point is that it can trace frequency based on optimized frequency as compared with the phase difference because we can input optimized resonant frequency while in motoring. And we test the speed of USM with the adjustment of multi-parameters, the phase difference-frequency. As the result of the test, in the case of the multi-parameters of the phase difference and frequency, the speed characteristic is more linear and stable, and wider in the range of control than the single-parameter of the phase difference or the frequency.

광중합형 프린터로 제작한 임시 의치용 인공치아의 UV형 초음파 세척에 따른 선형측정 평가 (Linear measurement evaluation according to UV-type ultrasonic cleaning of artificial teeth for temporary dentures manufactured using a light-curing type printer produced by a DLP printer)

  • 김동연;이광영
    • 대한치과기공학회지
    • /
    • 제46권1호
    • /
    • pp.8-14
    • /
    • 2024
  • Purpose: This study compares the deformation of traditional resin dentures to resin dentures printed with digital light processing (DLP). Methods: Eleven edentulous research models were developed. Ten of them were made with traditional resin dentures. The remaining one was prepared for scanning and 3D (three-dimensional) printing. Ten traditional resin dentures were made, with the remaining artificial teeth created using 3D software and a DLP printer. Traditional resin dentures, 3D printed resin denture artificial teeth, and a denture base with artificial teeth were all cleaned simultaneously in an ultrasonic cleaner for 3 minutes. Three groups were assigned four artificial tooth measurement points, which were then measured with digital calipers. The measured data was analyzed using descriptive statistics. The significance test was conducted using a nonparametric test Kruskal-Wallis test due to the small number of specimens (α=0.05). Results: The traditional resin dentures had the lowest strain rate at -0.04%, while the group that manufactured only artificial teeth had the highest strain rate at -0.09%. However, no statistically significant difference was observed between the 3 groups (p>0.05). Conclusion: During ultraviolet-type ultrasonic cleaning, traditional resin dentures (TD group) and denture base with artificial teeth made of DLP (DD group) demonstrated stable durability, whereas the artificial teeth made of DLP (AD group) with only artificial teeth did not show a good deformation rate.

초음파 영상에서 동적영역과 주파수 방식의 설정에 따른 효과 (Effects of Settings in Dynamic Ranges and Frequency Modes on Ultrasonic Images)

  • 양정화;강관석;이경성;팽동국;최민주
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권3호
    • /
    • pp.277-283
    • /
    • 2009
  • 임상에서 정확한 진단을 위해 양질의 초음파 영상을 얻는 것은 중요하다. 본 연구에서는 초음파 진단기의 주파수와 동적 영역(dynamic range, DR) 설정 및 프로브 유형에 따른 초음파 영상의 변화를 관찰하였다. 실험에서 고형 및 낭성 종괴 병변과 유사한 초음파 평가 팬텀(539,551, ATS, USA)의 6가지 LCS(low contrast sensitivity) 표적(-15, -6, -3, +3, +6, +15 dB)에 대한 영상을 대상으로 평가하였다. 초음파 영상은 볼록형(convex, C3-7IM) 및 선형(linear probe, L5-12IM) 두 가지 탐촉자(Probe)에 대해 SA-9900(Medison Ltd, Korea)을 이용하여 얻었다. 주파수는 4가지 방식(gen, pen, res, harmonic), 동적영역은 $40{\sim}100\;dB$ 범위에서 설정을 변화하면서 영상을 취득하였다. 취득한 영상의 질은 표적의 명목상 LCS 값과 영상에서 측정된 LCS을 비교하여 평가 하였다. 실험 결과 볼록형 탐촉자의 경우, 각 LCS 표적에 대해 주파수 방식 별로 동적영역 값을 40, 60, 80, 100 dB로 변화할 때, 초음파 영상의 질은 유의한 변화가 없었다. 그러나 낭종성 병변에 가까운 LCS 표적 -15 dB에서는 동적영역 60 dB과 하모닉 주파수 방식에서 LCS 값이 높게 나타났다. 선형 프로브에서는 -15 dB LCS 표적에서 동적영역 40 dB, 하모닉 방식에서 명목상 값에 근접하였다. LCS관점에서 정량화된 영상의 평가의 한계와 주관적인 평가 즉 심리적인 관점에서의 ROC(Receiver Operating Characteristic) 평가의 필요성에 대해 토의하였다.

  • PDF

압축파 속도를 이용한 콘크리트의 강도 평가 (Evaluation of Concrete Strength Using Compression Wave Velocity)

  • 이회근;이광명;김동수;김지상
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.697-702
    • /
    • 1999
  • Among several non-destructive testing methods, ultrasonic pulse velocity method has been widely used for the evaluation of concrete strength. However, this method might not provide accurate estimated results since factors influencing the relationship between strength and wave velocity is not considered. In this study, the evaluation methods of concrete strength using compression wave velocities measured by either ultrasonic pulse velocity method or impact-resonance method are proposed. A basic equation is obtained by the linear regression with velocity vs. strength data at a specific age and then, ageing factor is employed in the equation to consider the difference of the increasing rate between wave velocity and strength. Strengths predicted by the proposed equation agree well with test results.

  • PDF