• Title/Summary/Keyword: linear source

Search Result 1,139, Processing Time 0.027 seconds

Health Locus of Control in Indonesian Women with Breast Cancer: a Comparison with Healthy Women

  • Iskandarsyah, Aulia;de Klerk, Cora;Suardi, Dradjat R.;Sadarjoen, Sawitri S.;Passchier, Jan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9191-9197
    • /
    • 2014
  • The aims of this study were to assess whether Indonesian women with breast cancer havea higher external health locus of control (HLC) than healthy women, and to explore the association between HLC and symptoms of anxiety and depression. In this study, 120 consecutive women with breast cancer were recruited at the outpatient surgical oncology clinic at the Hasan Sadikin Hospital in Bandung. One hundred and twenty two healthy women were recruited from the Bandung area as controls. A standard demographic form, Form C of the Multidimensional Health Locus of Control, as well as the Hospital Anxiety and Depression Scale and patients' medical records were used. Data were analyzed using descriptive statistics, t-test, Pearson's correlation, MANOVA and multiple linear regressions. Women with breast cancer had higher scores on all external HLC subscales, i.e. chance, doctor, powerful others and God, and lower internal HLC compared to healthy women. High God LHC scores were associated with a high level of anxiety (${\beta}=0.21$, p<0.05), whereas none of the HLC subscales were associated with depression. Our results suggest that women with breast cancer tend to have high external HLC, while healthy women tend to have high internal HLC. A strong belief in an external source of control, i.e. God, might be negatively associated with patient emotional adjustment. Further research is needed to give an insight into the direction of this association.

Study for the Development of an Optimum Hull Form using SQP (SQP법을 이용한 최적선형개발에 대한 연구)

  • Choi, Hee-Jong;Lee, Gyoung-Woo;Kim, Sang-Hoon;Kim, Ho
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.29 no.1
    • /
    • pp.47-53
    • /
    • 2005
  • This paper presents the method for developing an optimum hull form with minimum wave resistance using SQP(sequential quadratic programming) as an optimization technique. The wave resistance is evaluated by a Rankine source panel method with non-linear free surface conditions and the ITTC 1957 friction line is used to predict the frictional resistance coefficient. The geometry of the hull surface is represented and modified using NURBS(Non-Uniform Rational B-Spline) surface patches. To verity the validity of the developed program the numerical calculations for Wigley hull and Series 60(C${_B}$=0.6) hull had been performed and the results obtained after the numerical calculations had been compared with the original hulls.

  • PDF

Packet Classification Using Two-Dimensional Binary Search on Length (길이에 대한 2차원 이진검색을 이용한 패킷분류 구조)

  • Mun, Ju-Hyoung;Lim, Hye-Sook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.9B
    • /
    • pp.577-588
    • /
    • 2007
  • The rapid growth of the Internet has stimulated the development of various new applications and services, and the service providers and the Internet users now require different levels of service qualities rather than current best-effort service which treats all incoming packet equally. Therefore, next generation routers should provide the various levels of services. In order to provide the quality of services, incoming packets should be classified into flows according to pre-defined rules, and this should be performed for all incoming packets in wire-speed. Packet classification not only involves multi-dimensional search but also finds the highest priority rule among all matching rules. Area-based quad-trie is a very good algorithm that constructs a two-dimensional trie using source and destination prefix fields. However, it performs the linear search for the prefix length, and hence it does not show very good search performance. In this paper, we propose to apply binary search on length to the area-based quad-trie algorithm. In improving the search performance, we also propose two new algorithms considering the priority of rules in building the trie.

Studies on Dose Distribution and Treatment Technique of High Energy Electron (고(高)에너지 전자선(電子線) 치료(治療)를 위(爲)한 선량분포(線量分布) 및 기술적(技術的) 문제(問題)의 연구(硏究))

  • Lee, D.H.;Chu, S.S.
    • Journal of Radiation Protection and Research
    • /
    • v.3 no.1
    • /
    • pp.6-22
    • /
    • 1978
  • High energy electron beams took effect for tumor radio-therapy, however, had a lot of problems in clinical application because of various conversion factors and complication of physical reactions. Therefor, we had experimentally studied the important properties of high energy electron beams from the linear accelerator, LMR-13, installed in Yonsei Cancer Center. The results of experimental studies on the problems in the 8, 10, 12 Mev electron beam therapy were reported as following. 1. On the measurements of the outputs and absorbed doses, the ionization type dosimeters that had calibrated by $^{90}Sr$ standard source were suitable as under 3% errors for high energy electrons to measure, but measuring doses in small field sizes and the regions of rapid fall off dose with ionization chambers were difficult. 2. The electron energy were measured precisely with energy spectrometer consisted of magnet analyzer and tele-control detector and the practical electron energy was calculated under 5% errors by maximum range of high energy electron beam in the water. 3. The correcting factors of perturbated dose distributions owing to radiation field, energy and material of the treatment cone were checked and described systematically and variation of dose distributions due to inhomogeneous tissues and sloping skin surfaces were completely compensated. 4. The electron beams, using the scatterers; ie., gold, tin, copper, lead, aluminium foils, were adequately diffused and minimizing the bremsstrahlung X-ray induced by the electron energy, irradiation field size and material of scatterers, respectively. 5. Inproving of the dose distribution from the methods of pendulum, slit, grid and focusing irradiations, the therapeutic capacity with limited electron energy could be extended.

  • PDF

Characteristics of CCD Based Optical CT Scanner for Therapeutic Radiation Dosimetry (치료방사선량평가를 위한 CCD 기반 광학컴퓨터단층촬영 스캐너의 특성)

  • Lee, Jae Choon;Kim, Ae Ran;Ji, Young Hoon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.72-78
    • /
    • 2016
  • A CCD camera and an LED light source were combined to fabricate a compact optical CT scanner for the therapeutic radiation dose evaluation of a polymer gel dosimeter. After the collimated beam emitted by the LED passed through aquarium, gel phantom, and telecentric lens, an image was collected by the CCD camera and reconstructed using MATLAB. By using a stepping motor and LabVIEW, the gel dosimeter was rotated at every $0.72^{\circ}$, and the time for collecting 500 slice images per a revolution was within 20 min. At a spatial frequency of 4.5 lp/mm of the optical CT scanner, the modulation transfer function value was 72%. The linear correlation coefficient of the optical CT scanner for the polymer gel dosimeter was 0.987.

The estimation of thermal diffusivity using NPE method (비선형 매개변수 추정법을 이용한 열확산계수의 측정)

  • 임동주;배신철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1679-1688
    • /
    • 1990
  • The method of nonlinear parameter estimation(NPE), which is a statistical and an inverse method, is used to estimate the thermal diffusivity of the porous insulation material. In order to apply the NPE method for measuring the thermal diffusivity, and algorithm for programing suitable to IBM personal computer is established, and is studied the statistical treatment of experimental data and theory of estimation. The experimental data obtained by discrete measurement using a constant heat flux technique are used to find the boundary conditions, initial conditions, and the thermal diffusivity, and then the final values are compared with the values obtained by some different methods. The results are presented as follows:(1) NPE method is used to establish the estimation of the thermal diffusivity and compared results with experimental output shows, that this method can be applicable to define the thermal diffusivity without considering hear flux types. (2) Because of all of the temperatures obtained by the discrete measurement on each steps of time are used to estimate the thermal diffusivity. Although some error in the temperature measurements of temperature are included in estimating process, its influences on the final value are minimzed in NPE method. (3) NPE method can reduce the experimental time including the time of data collecting in a few minutes and can take smaller specimen compared with steady state method. If the tube-type furnace is used, also the adjusting time of surrounding temperature can be reduced.

Effects of Aspect Ratio on Diffusive-Convection During Physical Vapor Transport of Hg2Cl2 with Impurity of NO (염화제일수은과 일산화질소의 물리적 승화법 공정에서의 확산-대류에 미치는 에스펙트 비율의 영향)

  • Kim, Geug-Tae
    • Applied Chemistry for Engineering
    • /
    • v.26 no.6
    • /
    • pp.746-752
    • /
    • 2015
  • This study investigates the effects of aspect ratio (transport length-to-width) on diffusive-convection for physical vapor transport processes of $Hg_2Cl_2-NO$ system. For a system with the temperature difference of 20 K between an interface at the source material region and growing crystal interface, the linear temperature profiles at walls, the total molar fluxes at Ar = 2 are much greater than Ar = 5 as well as the corresponding nonuniformities in interfacial distributions due to the effect of convection. The maximum total molar flux at the gravitational acceleration of 1 $g_0$ is greater twice than at the level of 0.1 $g_0$, where g0 denotes the gravitational acceleration on earth. With increasing aspect ratio from 2 to 5, a diffusive-convection mode is transited into the diffusion mode, and then the strength of diffusion is predominant over the strength of diffusive-convection.

Characteristics of nanolithograpy process on polymer thin-film using near-field scanning optical microscope with a He-Cd laser (He-Cd 레이저와 근접장현미경을 이용한 폴리머박막 나노리소그라피 공정의 특성분석)

  • Kwon S. J.;Kim P. K.;Chun C. M.;Kim D. Y.;Chang W. S.;Jeong S. H.
    • Laser Solutions
    • /
    • v.7 no.3
    • /
    • pp.37-46
    • /
    • 2004
  • The shape and size variations of the nanopatterns produced on a polymer film using a near-field scanning optical microscope(NSOM) are investigated with respect to the process variables. A cantilever type nanoprobe having a 100nm aperture at the apex of the pyramidal tip is used with the NSOM and a He-Cd laser at a wavelength of 442nm as the illumination source. Patterning characteristics are examined for different laser beam power at the entrance side of the aperture($P_{in}$), scan speed of the piezo stage(V), repeated scanning over the same pattern, and operation modes of the NSOM(DC and AC modes). The pattern size remained almost the same for equal linear energy density. Pattern size decreased for lower laser beam power and greater scan speed, leading to a minimum pattern width of around 50nm at $P_{in}=1.2{\mu}W\;and\;V=12{\mu}m/s$. Direct writing of an arbitrary pattern with a line width of about 150nm was demonstrated to verify the feasibility of this technique for nanomask fabrication. Application on high-density data storage is discussed.

  • PDF

Head Mouse System Based on A Gyro and Opto Sensors (각속도 및 광센서를 이용한 헤드 마우스)

  • Park, Min-Je;Yoo, Jae-Ha;Kim, Soo-Chan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.4
    • /
    • pp.70-76
    • /
    • 2009
  • We proposed the device to control a computer mouse with only head movements and eye blinks so that disabilities by car or other accidents can use a computer. The mouse position were estimated from a gyro-sensor which can measure head movements, and the mouse events such as click/double click were from opto sensors which can detect the eyes flicker, respectively. The sensor was mounted on the goggle in order not to disturb the visual field. There was no difference in movement speed between ours and a general mouse, but it required 3$\sim$4 more times in the result of the experiment to evaluate spatial movements and events detection of the proposed mouse because of the low accuracy. We could eliminate cumbersome work to periodically remove the accumulated error and intuitively control the mouse using non-linear relative point method with dead zones. Optical sensors are used in the event detection circuitry designed to remove the influence of the ambient light changes, therefore it was not affected in the change of external light source.

A Novel Fiber Bragg Grating Sensing Interrogation Method Using Bidirectional Modulation of a Mach-Zehnder Electro-Optical Modulator (Mach-Zehnder 광변조기의 양방향 변조를 이용한 새로운 광섬유격자 센서 검출 방법)

  • Mao, Wankai;Pan, Jae-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.7
    • /
    • pp.17-22
    • /
    • 2010
  • We have proposed and experimentally demonstrated a novel fiber Bragg grating (FBG) sensing interrogation method using bidirectional modulation of a Mach-Zehnder electro-optical modulator (MZ-EOM). The proposed structure consists mainly of a broadband light source (BBS), FBG, MZ-EOM, chirped fiber Bragg grating (CFBG), and photodetector (PD). We have obtained the transfer functions of the proposed structure and calculated the time delay from the change in the free spectral range (FSR) for ten wavelengths over the frequency range of 505 MHz to 525 MHz. The results show that the time delay and the wavelength variation have a good linear relationship with a gradient of 12.9 ps/0.2 nm, which can be usefully applied to FBG strain or temperature sensors and other multiplexed sensor applications.