• Title/Summary/Keyword: linear plasma

Search Result 394, Processing Time 0.032 seconds

A Direct Reading Atomic Emission Spectrometer for Chemical Analysis in the Iron and Steels (직독식 원자방출분광기를 이용한 철강중의 성분원소 분석)

  • Kim, Yeong Man;Jeong, Chan Lee;Kim, Seon Tae;Choe, Beom Seok
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.11
    • /
    • pp.800-807
    • /
    • 1994
  • A method to determine the iron and steels employing a Direct Reading Atomic Emission Spectrometer was investigated. Matrix effect was removed by two correction methods which utilize linear and curvilinear functions. Although two methods gave different sets of matrix correction coefficients, the analytical results by the two methods gave the same results. The analytical results obtained by the present work were well agreed with those obtained by inductively coupled plasma spectrometry.

  • PDF

롤투롤 시스템을 적용한 메탈 메쉬 전극 소재의 특성 향상 연구

  • Byeon, Eun-Yeon;Choe, Du-Ho;Kim, Do-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.133.2-133.2
    • /
    • 2016
  • 차세대 디스플레이로 유연하고 투명한 기능들이 요구되면서 Indium Tin Oxide(ITO)를 대체하기 위한 투명전극 개발 연구가 많이 수행되고 있다. ITO는 높은 투과도와 낮은 저항으로 현재 가장 많이 활용되고 있는 투명전극 소재이지만 유연성이 떨어져 유연 터치 패널 소재로 활용하기 어렵다. 이러한 문제 해결을 위해 ITO 대체 물질로 CNT, Graphene, Metal mesh, Ag nano wire, 전도성 고분자 등의 차세대 투명 전극 소재가 대두되고 있다. 본 연구에서는 메탈 메쉬 전극 소재로 사용하기 위해 Cu 박막 증착 시 플라즈마 표면처리를 통해 밀착력 및 저항을 개선하였다. Cu 금속 박막의 양산화를 위한 공정으로 자체 제작한 Linear Ion Source(LIS)가 부착된 roll to roll 시스템을 적용하여 플라즈마 전처리 공정 및 Ni buffer layer 도입 이후 Cu 박막을 형성하였다. 그 결과 PET 기판과 Cu 박막 사이의 밀착력을 0 degree에서 5 degree까지 향상시킬 수 있었고, 플라즈마 표면처리를 시행함으로써 저항 또한 감소되는 결과를 얻을 수 있었다. 본 연구를 통해서 폴리머 기판 소재에 in-situ로 표면처리 및 Cu 금속 박막을 증착함으로써 금속 박막의 밀착력 및 전기적 특성이 향상되는 공정 기술을 개발하였다.

  • PDF

Electrical Properties of Silicon Nitride Thin Films Formed (ECR 플라즈마에 의해 형성된 실리콘 질화막의 전기적 특성)

  • 구본영;전유찬;주승기
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.10
    • /
    • pp.35-41
    • /
    • 1992
  • Ultra-thin silicon nitride films were fabricated with ECR(Electron cyclotron Resonance) nitrogen plasma at room temperature. Film thickness was about 50$\AA$ after nitridation for 1min at microwave power of 1000W, RF power of 500W, and NS12T pressure of ${\times}10^{-3}$ torr. 50$\AA$ fo nitride film was grown within 1 min and no appreciable growth occured thereafter. Dielectric breakdown strength and leakage current density in Al/SiN/Si structure were measured to be about 7-11 MV/cm and ${\times}10^{-10}~5{\times}10^{-10}A/cm^{2}$, respectively. Observed linear relationship in 1n(J/E)-vs-E$^{1/2}$ and no polarity-dependence of the leakage current indicated that the Poole-Frenkel emission is mainly responsible for the conduction in this nitrided silicon films.

  • PDF

Potentiometric Sensor for the Determination of Dibucaine in Pharmaceutical Preparations and Electrochemical Study of the Drug with BSA

  • Ensafi, Ali A.;Allafchian, A.R.
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2722-2726
    • /
    • 2011
  • Plasticized poly(vinyl chloride), PVCs, with different membrane compositions tested for use in the construction of an ion-selective sensor for the determination dibucaine. A prepared membrane with dioctyl phthalate-PVC and ion-pair of N-(1-naphthyl)ethylenediamine dihydrochloride-tetraphenyl borate had a good potential to acts as a potentiometric sensor for the analysis of dibucaine. A linear relationship was obtained between potential and logC varying between $1.0{\times}10^{-6}$ and $1.0{\times}10^{-2}$ M dibucaine with a good repeatability and reproducibility. The sensor was applied for the determination of the drug in pharmaceuticals and biological fluids such as plasma and urine samples with satisfactory results. The drug electrode has also been used to study the interaction of bovine serum albumin (BSA) with dibucaine. The saturated quantities of dibucaine binding were 13.04, 5.30 and 9.70 mol/mol in 0.01, 0.02 and 0.1% of protein, respectively.

Pharmacokinetics of Furosemide in Rabbits with Renal Failure (신장장해 가토에서 Furosemide의 약물동태)

  • Choi, Jun-Shik;Choi, Tou-Ma;Lee, Jin-Hwan;Burm, Jin-Pil
    • YAKHAK HOEJI
    • /
    • v.34 no.6
    • /
    • pp.401-406
    • /
    • 1990
  • The Pharmacokinetics of furosemide (5 mg/kg iv) was investigated in rabbits with folate (75 mg/kg, 150 mg/kg 300 mg/ug, iv) induced renal failure. The plasma concentration was increased and urinary excretion was decreased significantly compared with those of normal rabbits. ${\alpha},\;{\beta}\;and\;K_{12},\;K_{21},\;K_{10}$ were decreased, $t_{1/2}$ and AUC were increased significantly. Correlation of serum creatinine concentration and AUC, renal clearance have linear relationship respectively. In short, dosage regimen of furosemide is considered to be adjusted in the dose size and the dosing interval by degree of serum creatinine concentration.

  • PDF

Effects of Aluminum and Silicon as Additive Materials for the Zinc Anode in Zn-Air Batteries

  • Lee, Yong-Seok;Ryu, Kwang-Sun
    • Journal of the Korean Electrochemical Society
    • /
    • v.21 no.1
    • /
    • pp.12-20
    • /
    • 2018
  • To solve low cycle efficiency of the zinc anode in Zn-air batteries by corrosion, this study examined the effects of Al as a cathodic protection additive to Zn. The Al-mixed Zn anodes were produced by mixing Zn and Al powder (1, 2, and 3 wt. %). To compare the effects of the Al additive, Si was selected under the same conditions. The morphology and elemental composition of the additives in the Zn were characterized by scanning electron microscopy, energy dispersive X-ray spectroscopy, and inductively coupled plasma - mass spectrometry. The anti-corrosion effects of the Al and Si-mixed Zn anodes were examined by linear polarization. Cyclic voltammetry and charge-discharge tests were conducted to evaluate the electrochemical performance of the Al and Si-mixed Zn anodes. As a result, the Al-mixed Zn anodes showed highest corrosion resistance and cycling performance. Among these, the 2 wt.% Al-mixed Zn anodes exhibited best electrochemical performance.

Simultaneous Determination of Plasma Lactate, Pyruvate, and Ketone Bodies following tert-Butyldimethylsilyl Derivatization using GC-MS-SIM

  • Yoon, Hye-Ran
    • Biomedical Science Letters
    • /
    • v.21 no.4
    • /
    • pp.241-247
    • /
    • 2015
  • Lactate and ketone bodies are considered biological markers for ketosis and several inherited metabolic disorders. In the current study, the specific ratios of lactate and ketone bodies as analytical tools for differential diagnosis of various lactic acidosis were devised. The study included a protein precipitation step following tert-butyldimethylsilyl derivatisation. Total run time was approximately 30 min including sample preparation and GS/MS analysis. The limits of detection were below 0.1 pg/mL over the targeted 4 analytes. The calibration curve was linear over the concentration range of $0.001{\sim}250{\mu}g/mL$ for pyruvate, beta-hydroxybutyrate, and acetoacetate ($R^2$ > 0.99). Inter-day accuracy and precision were 87.7~94.8% with RSD of 2.5~5.7% at 2 levels. Absolute recoveries (%) of target analytes were 87.0~98.4%. The method was validated for the quantification of lactate and ketone bodies for differentiation of lactic acidosis.

Determination of Tungsten Target Parameters for Transmission X-ray Tube: A Simulation Study Using Geant4

  • Nasseri, Mohammad M.
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.795-798
    • /
    • 2016
  • Transmission X-ray tubes based on carbon nanotube have attracted significant attention recently. In most of these tubes, tungsten is used as the target material. In this article, the well-known simulator Geant4 was used to obtain some of the tungsten target parameters. The optimal thickness for maximum production of usable X-rays when the target is exposed to electron beams of different energies was obtained. The linear variation of optimal thickness of the target for different electron energies was also obtained. The data obtained in this study can be used to design X-ray tubes. A beryllium window was considered for the X-ray tube. The X-ray energy spectra at the moment of production and after passing through the target and window for different electron energies in the 30-110 keV range were also obtained. The results obtained show that with a specific thickness, the target material itself can act as filter, which enables generation of X-rays with a limited energy.

Porous Bio-degradable Nano-fiber Machining by Femtosecond Laser (다공성 친바이오 나노섬유 극초단 레이저 가공특성 연구)

  • Choi, Hae-Woon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.3
    • /
    • pp.339-345
    • /
    • 2012
  • Electrospun meshed poly-caprolactone PCL was patterned by femtosecond laser with linear grooves. As parametric variables, focus spot size, pulse energy, and scanning speed were varied to determine the affects on groove size and the characteristics of the electrospun fiber at the edges of these grooves. The femtosecond laser was seen to be an effective means for flexibly structuring the surface of ES PCL scaffolds and the width of the ablated grooves was well controlled by laser energy and focus spot size. The ablation threshold was measured to be $14.9J/cm^2$ which is a little higher than other polymers. These affects were attributed to optical multiple reflections inside nano-fibers. By the laser-induced plasma at higher pulse energies, some melting of fibers was observed.

Effect of a Magnetic Field on Electrical Conductivity of a Partially Ionized Plasma

  • Yun, Hong-Sik
    • Journal of The Korean Astronomical Society
    • /
    • v.8 no.1
    • /
    • pp.29-34
    • /
    • 1975
  • Solar electrical conductivity has been calculated, making use of Yun and Wyller's formulation. The computed results arc presented in a tabulated form as functions of temperature and pressure for given magnetic field strengths. The results of the calculation show that the magnetic field does not play any important role in characterizing the electrical conductivity of the ionized gas when the gas pressure is relatively high (e.g., $P{\geq}10^4\;dynes/cm^2$). However, when the gas pressure is low (e.g., $P{\leq}10\;dynes/cm^2$), the magnetic field becomes very effective even if its field strength is quite small (e.g., $B{\leq}0.01$ gauss). It is also found that, except for lower temperature region (e.g., $T{\leq}10^{4^{\circ}}K$), there is a certain linear relationship in a log- log graph between the pressure and the critical magnetic field strength, which is defined as a field strength capable of reducing the non-magnetic component of the electrical conductivity by 20%.

  • PDF