• Title/Summary/Keyword: linear meridian

Search Result 16, Processing Time 0.027 seconds

A study on Twelve meridian Biaoben(標本) pulse diagnosis method among the ancient meridian diagnosis method (고대(古代)의 경맥진단법(經脈診斷法) 중(中) 십이경표본맥진법(十二經標本脈診法)에 관(關)한 연구(硏究))

  • Lee, Dong-hee;Hwang, Min-seob;Yoon, Jong-hwa
    • Journal of Acupuncture Research
    • /
    • v.21 no.1
    • /
    • pp.21-32
    • /
    • 2004
  • Objective: A study on $\ll$Lingchui, 靈樞 Weiqi, 衛氣$\gg$ which descripted Twelve meridian Biaoben(標本) pulse diagnosis method. Methods: A study on Twelve meridian Biaoben(標本) pulse diagnosis method which has the cognizance of Biaoben(標本) on upper and low twelve meridian as linear upper and low pulse diagnosis point. Results: Twelve meridian Biaoben(標本) pulse diagnosis method is derived from using each twelve meridian pulse diagnosis and it can be explained that the ben(本) pulse point on wrist ankle and the biao(標) pulse point on thorax axillary neck head face correspond to upper and low part of meridian for diagnosis and treatment which become the theory of "treat upper disease on low part, treat low disease on upper part". Conclusions: Twelve meridian Biaoben(標本) pulse diagnosis method started confirming the general concept of Jue-symptom(厥症) and Jue-symptom(絶症) and developed upper and low pulse diagnosis point or acupuncture point to treatment.

  • PDF

Development of PEMWE MEA & System for Discrete Regenerative Fuel Cell (분리형 재생 연료전지를 위한 수전해 MEA 및 시스템 개발)

  • CHOI, NAKHEON;YOON, DAEJIN;HAN, CHANGHYUN;LEE, JUNYEONG;SONG, MINAH;JUNG, HYEYOUNG;CHOI, YUNKI;MOON, SANGBONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.4
    • /
    • pp.335-340
    • /
    • 2016
  • Hydrogen production through proton exchange membrane water electrolysis (PEMWE) is expeditiously receiving international attention for renewable energy sources as well as energy storage system applications due to its environmentally friendly uses. A series of $Ir_{0.2}Ru_{0.8}O_2$ $Ir_{0.5}Ru_{0.8}O_2$ & $IrO_2$ catalysts were synthesized and electrochemically evaluated by using linear sweep voltammetry (LSV) technique. Furthermore, the PEMWE performances of full cells were evaluated by recording I-V Curves. The developed PEMWE stack was also operated in combination with a proton exchange membrane fuel cell (PEMFC) to demonstrate the discrete regenerative fuel cell (DRFC) performances. Produced hydrogen and oxygen from PEMWE were used as a fuel to operate PEMFC to establish a DRFC system.

The Morphology Study of Organ Surface BongHan Ducts and Corpuscle (장기표면의 내외봉한관과 봉한소체의 형태학적 관찰)

  • Ahn, Seong-Hun;Kim, Min-Su;Lee, Sang-Hun;Kwon, O-Sang;Kim, Jae-Hyo;Soh, Kwang-Sup;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.26 no.1
    • /
    • pp.79-84
    • /
    • 2009
  • Objective : In 1960's Bonghan Kim's team found BongHan(BH) ducts which were presumed as acupuncture meridians and BH corpuscles. They asserted Bonghan theory and SanAl theory which was involved in cell division and cell restoration. However, many other experiments which had been operated to demonstrate and find the existence of BH ducts had failed because of the secret of blue stain drugs. During the last several years, BongHan theory has been revived through experimental researches to find the anatomical structures of BH ducts and corpuscles by Soh's Biomedical Physics Lab. Soh's research team used the staining with Janus Green B, Alcian blue, nanoparticles and Acridine Orange. We used DAPI staining to find the existence of BH ducts and the corpuscles and to observe nuclear arrangement. Methods : We used japan white rabbits as experimental animals. BH ducts and corpuscles were stained with DAPI. The nucleus configuration in BH ducts stained with DAPI were observed with microscope. Results : In this study, we found thread like structures in silver white color distinguished from the blood vessels, nerves and lymph vessels. These thread like vessels in the linear duct shape were connected to same colored mass in the ball shape. Thread like structures we found could be separated easily from the surrounding other organ mass. The nuclei of the thread like structure in DAPI staining, are about 10${\sim}$20${\mu}m$ length, in rod shape and linear arrangement. Conclusion : We concluded that the thread like structure we found was same vessel reported by Soh's research team, BongHan ducts and corpuscle.

  • PDF

Visual Fields Reflecting Effects of Target Size, Color and Meridian in Visual Tasks (시각작업의 설계와 평가를 위한 표적의 크기, 색과 위치에 따른 시각영역)

  • Kee, Do-Hyung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.27 no.2
    • /
    • pp.190-196
    • /
    • 2001
  • This study aims to develop three types of the visual fields: stationary field, eye field, and head field, which are classified depending upon the eye and head movements. A visual experiment taking target size, target color, and meridian into account was conducted, in which the L32 orthogonal array was employed. The results showed that target size and meridian were significant at ${\alpha}$=0.01 in all three visual fields. Contrary to expectation, target color was significant at ${\alpha}$=0.10 only in the head field. Furthermore, the differences in size of the head field depending upon four target colors were negligibly small. Three linear regression models were provided to generate visual fields which are appropriate for given visual task's characteristics. In addition, a simple method using adjusting factor was also proposed so that anyone without knowledge for human factors/ergonomics can easily generate and use them when designing or evaluating visual tasks. It is expected that the visual fields presented in this study can be easily used even by non-ergonomic experts in real situations due to their simplicity.

  • PDF

Wound Healing Activity of Gamma-Aminobutyric Acid (GABA) in Rats

  • Han, Dong-Oh;Kim, Hee-Young;Lee, Hye-Jung;Shim, In-Sop;Hahm, Dae-Hyun
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.10
    • /
    • pp.1661-1669
    • /
    • 2007
  • Gamma-aminobutyric acid (GABA) is a non-protein amino acid. It is well known for its role as an inhibitory neurotransmitter of developing and operating nervous systems in brains. In this study, a novel function of GABA in the healing process of cutaneous wounds was presented regarding anti-inflammation and fibroblast cell proliferation. The cell proliferation activity of GABA was verified through an MTT assay using murine fibroblast NIH3T3 cells. It was observed that GABA significantly inhibited the mRNA expression of iNOS, IL-$1{\beta}$, and TNF-${\alpha}$ in LPS-stimulated RAW 264.7 cells. To evaluate in vivo activity of GABA in wound healing, excisional open wounds were made on the dorsal sides of Sprague-Dawley rats under anesthesia, and the healing of the wounds was apparently assessed. The molecular aspects of the healing process were also investigated by hematoxylineosin staining of the healed skin, displaying the degrees of re-epithelialization and linear alignment of the granulation tissue, and immunostaining and RT-PCR analyses of fibroblast growth factor and platelet-derived growth factor, implying extracellular matrix synthesis and remodeling of the skin. The GABA treatment was effective to accelerate the healing process by suppressing inflammation and stimulating re-epithelialization, compared with the epidermal growth factor treatment. The healing effect of GABA was remarkable at the early stage of wound healing, which resulted in significant reduction of the whole healing period.

Comparative study between proportional method and directional method in locating acupoints at forearm (전완부(前腕部) 경혈(經穴) 취혈(取穴)에서 골도분촌법(骨度分寸法)과 일부법(一夫法)의 비교(比較) 연구(硏究))

  • Park, Hi-Joon;Chae, Youn-Byoung;Cha, Wung-Seok;Park, Jong-Bae;Lee, Hye-Jung;Lee, Hyang-Sook;Yin, Chang-Sik;Koh, Hyung-Kyun;Kim, Su-Young;Choe, Il-Hwan;Kim, Kang-Sik;Moon, Jung-Bae;Bae, Ki-Tae;Rheu, Kyoung-Hwan;Yook, Keun-Yung;Jeong, Byeong-Ju;Sohn, In-Chul;Lim, Sabina
    • Korean Journal of Acupuncture
    • /
    • v.21 no.4
    • /
    • pp.31-41
    • /
    • 2004
  • Background : The cun measurement system, an essential and convenient method in locating acupoints, has been widely used in the practice of acupuncture. However, traditional cun measurement has been criticized for its lack of reliability. Objectives : The purposes of this study are to determine if one cun measured by the directional methods have a consistency with that of proportional methods and to investigate which factors are related with these differences, especially in forearm. Methods : The distance between the elbow crease and the wrist crease of forearm was compared to a reference value of one cun obtained by the directional method. In this method, one cun is one third of the distance between index finger and small finger of a subject, measured at proximal interphalangeal joint. In addition, to investigate the factors influencing the differences between these two methods, we measured the height and body weight and calculated body mass index (BMI). Finally we analyzed the factors correlated with these lengths by linear regression test. Results : The results showed that one cun obtained by the directional methods were significantly different from one cun by the proportional methods in forearm. It was demonstrated that the length acquired with the directional method was more correlated with body weight and body mass index, while the length obtained by the proportional method was more correlated with the height. Conclusion : These findings suggest that the directional method is less likely dependable in locating acupoints than the proportional method because the influencing factors are different.

  • PDF

Stimulation of Blood Flow Needs a Parallel Magnetic Field and Psycho-physics acupuncture

  • Oh, Hung-Kuk
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.105-112
    • /
    • 2000
  • The conventional model did not take momentum conservation into consideration when the electron absorbs and emits the photons. II-ray provides momentum conservations on any directions of the entering photons, and also the electrons have radial momentum conservations and fully elastic bouncing between two atoms, in the new atom model. Conventional atom model must be criticized on the following four points. (1) Natural motions between positive and negative entities are not circular motions but linear going and returning ones, fur examples sexual motion, tidal motion, day and night etc. Because the radius of hydrogen atom's electron orbit is the order of 10$^{-11}$ m and the radia of the nucleons in the nucleus are the order of 10$^{-l4}$m and then the converging $\pi$-gamma rays to the nucleus have so great circular momentum, the electron can not have a circular motion. We can say without doubt that any elementary mass particle can have only linear motion, because of the $\pi$-rays' hindrances, near the nucleus. (2) Potential energy generation was neglected when electron changes its orbit from outer one to inner one. The h v is the kinetic energy of the photo-electron. The total energy difference between orbits comprises kinetic and potential energies. (3) The structure of the space must be taken into consideration because the properties of the electron do not change during the transition from outer orbit to inner one even though it produces photon. (4) Total energy conservation law applies to the energy flow between mind and matter because we daily experiences a interconnection between mind and body. Any magnet absorbs n-rays to S pole and sends out the $\pi$-rays from N pole. Proton are constructed with the closed n-rays quantum-mechanically. The crystallizing n-bonding makes two $\pi$-far infrared rays of one wave length between two protons if two $\pi$-rays are supplied to each proton. It is easily done for a $\pi$-ray to be absorbed to a proton if there is a parallel magnetic flow to the blood flow because a $\pi$-ray advances axially under a magnetic field and a proton looks like a sphere. A axially advancing disk-like $\pi$-ray can meet more easily the coming spheres than from the other directions. The blood crystals stimulate the autonomous nerves on the blood vessels during the flow by their mechanical sliding collisions. SM n-ray meridian therapy and SMACN $\pi$-ray meridian therapy show the stimulation of blood flow and also combinational experiment between SM $\pi$-ray meridian therapy and n-ray psycho-physics acupuncture shows more clearly that magnet is forcing to make $\pi$-rays absorbed to the nucleons.s.ons.

  • PDF

Optimal failure criteria to improve Lubliner's model for concrete under triaxial compression

  • Lei, Bo;Qi, Taiyue;Wang, Rui;Liang, Xiao
    • Computers and Concrete
    • /
    • v.28 no.6
    • /
    • pp.585-603
    • /
    • 2021
  • The validation based on the experimental data demonstrates that the concrete strength under triaxial compression (TC) is overestimated by Lubliner-Oller strength criterion (SC) but underestimated by Lubliner-Lee SC in ABAQUS. Moreover, the discontinuous derivatives of failure criterion exists near the unexpected breakpoints. Both resulted from the piecewise linear meridians of the original Lubliner SC with constants γ. Following the screen for the available failure criteria to determine the model parameter γ of Lubliner SC, Menétrey-Willam SC (MWSC) is considered the most promising option with a reasonable aspect ratio Kc but no other strength values required and only two new model parameters introduced. The failure surface of the new Lubliner SC based on MWSC (Lubliner-MWSC) is smooth and has no breakpoints along the hydrostatic pressure (HP) axis. Finally, predicted results of Lubliner-MWSC are compared with other concrete failure criteria and experimental data. It turns out that the Lubliner-MWSC can represent the concrete failure behavior, and MWSC is the optimal choice to improve the applicability of the concrete damaged plasticity model (CDPM) under TC in ABAQUS.

A Study on Damage-Assessment of RC Large Cooling Tower Shells (RC 대형 냉각탑 셀의 손상추정에 관한 연구)

  • Noh, Sam-Young
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2004.05a
    • /
    • pp.279-286
    • /
    • 2004
  • An accumulated crack damage which propagates progressively with time was frequently observed on several engineering structures, This paper numerically demonstrates this damage process on large cooling tower shells under thermal and wind loads. Damage states under varying loads are investigated and the influence of this progressive damage process on the life-cycle of cooling towers discussed. The paper presents briefly some fundamentals of the geometrically and physically non-linear numerical analysis employed for reinforced concrete, especially concerning the models used for concrete, steel reinforcement and the bond between them. As a numerical example an existing cooling tower with noticeable meridian crack damage is analysed. The existing damage state of the cooling tower is determined by quasi-static analyses for temperature, hygric and cyclic wind leading. The change in the dynamical behaviour of the structure as mirrored in its natural frequencies and mode shapes is presented and discussed. Finally, the example shows that such damage processes develop progressively over the life-time of the structures.

  • PDF

Two Node Meridional Strain-based Axisymmetric Shell Elements (자오 변형률에 근거한 2절검 축대칭 셸요소)

  • Ryu, Ha-Sang;Sin, Hyo-Chol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.6
    • /
    • pp.925-932
    • /
    • 1997
  • Two shear-flexible curved axisymmetric shell elements with two nodes, LCCS(linear curvature and constant strain) and CCCS(constant curvature and constant strain) are designed based on the assumed meridional strain fields and shallow shell geometry. At the element level, meridional curvature, membrane strain and shear strain fields are assumed by using polynomials and the displacement fields are obtained by integrating the assumed strain fields along the shallowly curved meridian. The formulated elements have high order displacement fields consistent with the strain field. Several test problems are given to demonstrate the performance of the two elements. Analysis results obtained reveal that the elements are very accurate in the displacement and the stress predictions.