• 제목/요약/키워드: linear isolator

검색결과 41건 처리시간 0.029초

수정히스테리틱 Bi-Linear 면진베어린 모델을 사용한 지진응답감소 (Reduction of the Seismetic rRspocses by Using the Modified Hysteretic Bi-Linear Model of the Seismic Isolator)

  • 구경회;이재한;김종범;이형연;유봉
    • 대한기계학회논문집A
    • /
    • 제20권1호
    • /
    • pp.127-134
    • /
    • 1996
  • In general, seismic isolators which are made of laminated rubber and shim plate have characteristics of complex hysteretic behavior. When shear deformation of the seismic isolator is small, the isolator hassimple hysteretic almost bi-linear behabior. But on large shear deformation hardening effects may occur. This paper proposes a moldeling method of the seimic isolator with modified hysteretic bi-linear model which can consider the hardening effects. From the results of the seismic analyses of the isolated system it is shown that the responses are singificantly reduced compared with those of the non-isolated system. The modified hysteretic bi-linear model of the isolator gives larger ZPA(zero period acceleration) than those of the simple hysteretic bi-linear model and the equivalunt spring-damper model.

HSLDS 마그네틱 진동절연체의 절연성능에 대한 설계 파라미터 분석 (Design Parameter Study on the Isolation Performance of the HSLDS Magnetic Vibration Isolator)

  • 신기홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.473-477
    • /
    • 2009
  • In general, the softer the stiffness of a linear vibration isolator the better the performance of isolation can be achieved. However, the stiffness of the isolator cannot be made too soft because it needs a sufficient stiffness to hold the load. This is the most critical limitation of a linear vibration isolator. Recently, a HSLDS (High-Static-Low-Dynamic-Stiffness) magnetic vibration isolator was proposed to overcome this fundamental limitation. The suggested isolator utilizes two pairs of attracting magnets that that introduces negative stiffness. Previously, this new type of vibration isolator was merely introduced and showed a possibility of practical use. In this paper, detailed dynamics of the HSLDS magnetic isolator are studied using computer simulations. Then, the isolation performance is examined for various design parameters to aid the practical use.

  • PDF

HSLDS 마그네틱 진동절연체의 절연성능에 대한 설계 파라미터 분석 (Design Parameter Study on the Isolation Performance of the HSLDS Magnetic Vibration Isolator)

  • 신기홍
    • 한국소음진동공학회논문집
    • /
    • 제20권1호
    • /
    • pp.92-97
    • /
    • 2010
  • In general, the softer the stiffness of a linear vibration isolator the better the performance of isolation can be achieved. However, the stiffness of the isolator cannot be made too soft because it needs a sufficient stiffness to hold the load. This is the most critical limitation of a linear vibration isolator. Recently, a HSLDS(high-static-low-dynamic-stiffness) magnetic vibration isolator was proposed to overcome this fundamental limitation. The suggested isolator utilizes two pairs of attracting magnets that introduces negative stiffness. Previously, this new type of vibration isolator was merely introduced and showed a possibility of practical use. In this paper, detailed dynamics of the HSLDS magnetic isolator are studied using computer simulations. Then, the isolation performance is examined for various design parameters to aid the practical use.

복굴절이 있는 광아이솔레이터의 동작 특성 분석 (Analysis of the operating characteristics of a birefringent optical isolator)

  • 조상연;강현서;이경식
    • 한국통신학회논문지
    • /
    • 제21권10호
    • /
    • pp.2731-2737
    • /
    • 1996
  • The effect of the birefringence existing in the Faraday rotator on the isolation and transmission properties of the isolator was investigated. To maintain isolation of 50dB, both the deviation of the transmission angle between input and output polarizers and the deviation of the Faraday ratation angle are permitted to .+-.0.18.deg. for birefringenceless isolator and to .+-.0.09.deg. for birefringent isolator. This means that the isolator possessing linear birefringence of 0.5.deg. requires 505 more accurage adjustment than that of no birefringence. We also simulated the characteristics of wavelength dependence for both the virefringent isolator and the birefringencelless isolator. It is also found that formward transmission loss doesn't varing much with small birefringence.

  • PDF

설계 파라미터를 고려한 HSLDS 마그네틱 진동절연체의 실험적 성능평가 (Experimental Evaluation of the Performance of the HSLDS Magnetic Vibration Isolator with Consideration of the Design Parameter)

  • 신기홍
    • 한국소음진동공학회논문집
    • /
    • 제21권4호
    • /
    • pp.352-356
    • /
    • 2011
  • The isolation performance of a linear vibration isolator is limited to the ratio of stiffness to mass it supports. The stiffness of the isolator must be large enough to hold the weight. This results in the deterioration of the isolation performance. Recently, to overcome this fundamental limitation, the HSLDS(high-static-low-dynamic-stiffness) magnetic vibration isolator was introduced and its isolation characteristic was investigated theoretically. In this paper, the isolation performance of the HSLDS magnetic isolator is examined experimentally. Considerable amount of experiments are performed by carefully considering nonlinear characteristics. The experimental results verify the practical usability promisingly and agree with the theoretical studies, i.e. its performance is largely dependent on the key design parameter.

발사충격을 고려한 수동충격저감기의 위상최적설계 (Topology Optimization of Passive Shock Isolator with Application to Ballistic Shock)

  • 왕세명;임국희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.406-410
    • /
    • 2006
  • Topology optimization of improved passive shock isolator by controlling its force-deflection relation is proposed. And the final design which is optimized using topology optimization is obtained using shape optimization. The proposed methods are applied to a numerical example using two dimensional-axisymmetric condition. And the performance of finally optimized design is verified through transient analysis using LS-DYNA. The ballistic shock isolator model is developed as a result of topology optimization. The optimized design has more improved shock absorbing capability comparing to the linear shock isolator by about 20%.

  • PDF

비선형 진동절연 시스템의 근사적 응답을 구하는 방법 (Methods to Obtain Approximate Responses of a Non-Linear Vibration Isolation System)

  • 이건명
    • 한국기계가공학회지
    • /
    • 제19권6호
    • /
    • pp.23-28
    • /
    • 2020
  • A non-linear vibration isolation system composed of a non-linear spring and a linear damper was presented in a previous study. The advantage of the proposed isolator is the simple structure of the system. When the base of the isolator is harmonically excited, the response component of the mass at the excitation frequency was approximated using three different methods: linear approximation, harmonic balance, and higher-order frequency response functions (FRFs). The method using higher-order FRFs produces significantly more accurate results compared with the other methods. The error between the exact and approximate responses does not increase monotonously with the excitation amplitude and is less than 2%.

소형 인공위성 발사체 충격저감용 PTFE(테프론) 소재 아이솔레이터 연구 (The study of PTFE isolator equipped to small satellite launch vehicle to reduce the separation shock)

  • 정호경;윤세현;서상현;장영순;이영무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.358-362
    • /
    • 2006
  • Pyro-shock generally refers to the severe mechanical transients caused by the detonation of an ordnance device on a structure. Such device on a structure, including linear explosive, and point explosive are widely used to accomplish in-flight separation of structural elements on aerospace vehicle. And they are a significant cause of launch vehicle failures. The launch vehicle being developed in Korea also uses the explosive for separation events. In this paper, the isolator equipped to small satellite launch vehicle made of PTFE(Teflon) is developed to reduce the separation shock. The test to measure dynamic stiffness of PTFE isolator is performed. This test enables us to find the frequency range of PTFE isolator. And,, pyre-shock test using explosive to evaluate the performance of PTFE isolator is executed. from this study, the isolator conformed to frequency range and load requirement is developed using PTFE instead of rubber.

  • PDF

스핀밸브를 이용한 선형 GMR 아이솔레이터의 모델링 (Modeling of a linear GMR Isolator Utilizing Spin Valves)

  • 박승영;조순철
    • 한국자기학회지
    • /
    • 제14권6호
    • /
    • pp.232-235
    • /
    • 2004
  • 아날로그 형태의 신호를 전송하기에 적합한 특성을 보이는 선형 GMR(giant magnetoresistance) 아이솔레이터를 모델링하여 입력전류에 따른 출력전압과 전류를 조사하였다. GMR 아이솔레이터를 자기적 부분과 전기적 부분으로 나누고 선택된 스핀밸브 소자의 MR(magnetoresistance) 결과를 대입하여 출력전압을 구할 수 있는 순서도를 설정하였다. 자기적 모델링으로는 평판 코일의 3차원 모델을 FEM방법으로 해석하여 입력전류에 의해 생성되는 자장의 세기를 구하였으며, 여기에서 자기코어층이 있는 경우 50% 이상 더 커지는 결과를 얻었다. 그리고 아이솔레이터의 출력전압파형을 계산한 결과 입력 코일 전류에 따른 궤환 코일 전류가 $I_{out}$ = $I_{in}$ -5 mA의 선형함수와 비교시 평균 $\pm$0.25 mA 이내의 차이로 근사한 값으로 계산되었다. 또한 입력되는 코일 전류가 구형파일 때, 출력전압의 반응시간과 파형을 계산하였으며, 이때 최저전압에서 최대 전압까지 상승 및 하강하는 시간은 연산증폭 기의 slew rate가 0.3 V/${\mu}\textrm{s}$ 일 때, 최저전압에서 최대 전압까지 상승 및 하강하는 시간은 6 ${\mu}\textrm{s}$였다.

면진구조물 내 층응답스펙트럼 작성을 위한 고려사항 (Considerations for the Generation of In-Structure Response Spectra in Seismically Isolated Structures)

  • 이승재;김정한
    • 한국지진공학회논문집
    • /
    • 제26권2호
    • /
    • pp.95-103
    • /
    • 2022
  • In order to evaluate the earthquake safety of equipment in structures, it is essential to analyze the In-Structure Response Spectrum (ISRS). The ISRS has a peak value at the frequency corresponding to the structural vibration mode, but the frequency and amplitude at the peak can vary because of many uncertain parameters. There are several seismic design criteria for ISRS peak-broadening for fixed base structures. However, there are no suggested criteria for constructing the design ISRS of seismically isolated structures. The ISRS of isolated structures may change due to the major uncertainty parameter of the isolator, which is the shear stiffness of the isolator and the several uncertainty parameters caused by the nonlinear behavior of isolators. This study evaluated the effects on the ISRS due to the initial stiffness of the bi-linear curve of isolators and the variation of effective stiffness by the input ground motion intensity and intense motion duration. Analyzing a simplified structural model for isolated base structure confirmed that the ISRS at the frequency of structural mode was amplified and shifted. It was found that the uncertainty of the initial stiffness of isolators significantly affects the shape of ISRS. The variation caused by the intensity and duration of input ground motions was also evaluated. These results suggested several considerations for generating ISRS for seismically isolated structures.