• 제목/요약/키워드: linear discrepancy

검색결과 97건 처리시간 0.025초

Impact of scanning strategy on the accuracy of complete-arch intraoral scans: a preliminary study on segmental scans and merge methods

  • Mai, Hai Yen;Mai, Hang-Nga;Lee, Cheong-Hee;Lee, Kyu-Bok;Kim, So-yeun;Lee, Jae-Mok;Lee, Keun-Woo;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권2호
    • /
    • pp.88-95
    • /
    • 2022
  • PURPOSE. This study investigated the accuracy of full-arch intraoral scans obtained by various scan strategies with the segmental scan and merge methods. MATERIALS AND METHODS. Seventy intraoral scans (seven scans per group) were performed using 10 scan strategies that differed in the segmental scan (1, 2, or 3 segments) and the scanning motion (straight, zigzag, or combined). The three-dimensional (3D) geometric accuracy of scan images was evaluated by comparison with a reference image in an image analysis software program, in terms of the arch shape discrepancies. Measurement parameters were the intermolar distance, interpremolar distance, anteroposterior distance, and global surface deviation. One-way analysis of variance and Tukey honestly significance difference post hoc tests were carried out to compare differences among the scan strategy groups (α = .05). RESULTS. The linear discrepancy values of intraoral scans were not different among scan strategies performed with the single scan and segmental scan methods. In general, differences in the scan motion did not show different accuracies, except for the intermolar distance measured under the scan conditions of a 3-segmental scan and zigzag motion. The global surface deviations were not different among all scan strategies. CONCLUSION. The segmental scan and merge methods using two scan parts appear to be reliable as an alternative to the single scan method for full-arch intraoral scans. When three segmental scans are involved, the accuracy of complete arch scan can be negatively affected.

가상주행과 실차주행의 운전자 주행행태 차이에 관한 연구 (A Study on the Compensation of the Difference of Driving Behavior between the Driving Vehicle and Driving Simulator)

  • 박진호;임준범;주성갑;이수범
    • 한국도로학회논문집
    • /
    • 제17권2호
    • /
    • pp.107-122
    • /
    • 2015
  • PURPOSES : The use of virtual driving tests to determine actual road driving behavior is increasing. However, the results indicate a gap between real and virtual driving under same road conditions road based on ergonomic factors, such as anxiety and speed. In the future, the use of virtual driving tests is expected to increase. For this reason, the purpose of this study is to analyze the gap between real and virtual driving on same road conditions and to use a calibration formula to allow for higher reliability of virtual driving tests. METHODS : An intelligent driving recorder was used to capture real driving. A driving simulator was used to record virtual driving. Additionally, a virtual driving map was made with the UC-Win/Road software. We gathered data including geometric structure information, driving information, driver information, and road operation information for real driving and virtual driving on the same road conditions. In this study we investigated a range of gaps, driving speeds, and lateral positions, and introduced a calibration formula to the virtual record to achieve the same record as the real driving situation by applying the effects of the main causes of discrepancy between the two (driving speed and lateral position) using a linear regression model. RESULTS: In the virtual driving test, driving speed and lateral position were determined to be higher and bigger than in the real Driving test, respectively. Additionally, the virtual driving test reduces the concentration, anxiety, and reality when compared to the real driving test. The formula includes four variables to produce the calibration: tangent driving speed, curve driving speed, tangent lateral position, and curve lateral position. However, the tangent lateral position was excluded because it was not statistically significant. CONCLUSIONS: The results of analyzing the formula from MPB (mean prediction bias), MAD (mean absolute deviation) is after applying the formula to the virtual driving test, similar to the real driving test so that the formula works. Because this study was conducted on a national, two-way road, the road speed limit was 80 km/h, and the lane width was 3.0-3.5 m. It works in the same condition road restrictively.

Photon Knife 시스템에 근거한 뇌정위 방사선수술에서 표적위치 확인 (Verification of Target Position in Stereotactic Radiosurgery Based on Photon Knife System)

  • 최태진;김진희;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제14권2호
    • /
    • pp.99-107
    • /
    • 2003
  • 선형가속기(Mitsubishi, ML15MDX)를 이용한 방사선수술시스템인 Photon Knife에서 Linac-gram을 통해 선속-표적 위치를 확인하여 신뢰성 있는 시술을 유지하도록 하였다. 선속-레이저광 교정 기구를 제작하여 레이저광의 입사점과 사출점을 조사하여 빔의 위치결정에 이용하였다. 선형가속기에 부착한 보조 콜리메이터의 고정을 확인하기 위해 Isocenter에서 5 cm 떨어진 위치에 팔각형 필름지지체를 두도록 제작하고 확인용 필름(Kodak X-omat V2)을 설치하였다. 필름에 선형가속기의 지지체를 45$^{\circ}$씩 회전조사 하여 필름에 나타난 거리로 보조 콜리메이터의 이동을 확인한 결과 실험 오차내에서 이동이 없음을 확인하였다. 임상에 이용한 체위 표시기는 10 mm 쇠구슬 제도와 납인형을 두어 PKRS 시술시 환부의 체위를 쉽게 확인할 수 있도록 고안제작되었다. 앙와위 및 우측 측와위로 조사한 방사선수술에서 표적 위치기에 있는 양측 쇠구슬과 콜리메이터 조사면과의 일치를 LINAC-gram에서 확인한 결과 CT 영상의 표적좌표와 비교해서 평균 0.8$\pm$0.26 mm 의 오차범위에서 시술하였음을 보이므로 방사선조사의 정확성을 알 수 있다. 선형가속기의 Couch 에 임의의 힘을 가했을 때 위치변동은 좌우 $\pm$5 mm, Couch 축방향으로 $\pm$1 mm, 상하로 $\pm$2 mm 이동할 수 있음을 확인하였다. 이상의 결과로 Photon knife 방사선 수술 시스템은 방사선수술 전 환부의 표적과 선속의 일치를 LINAC-gram을 통해 확인할 수 있어 시술의 신뢰도를 높일 수 있을 것으로 생각된다.

  • PDF

안면 입체영상 중첩시 중첩 기준 범위 설정에 따른 적합도 차이 (VALIDITY OF SUPERIMPOSITION RANGE AT 3-DIMENSIONAL FACIAL IMAGES)

  • 최학희;조진형;박홍주;오희균;최진휴;황현식;이기헌
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권2호
    • /
    • pp.149-157
    • /
    • 2009
  • Purpose: This study was to evaluate the validity of superimposition range at facial images constructed with 3-dimensional (3D) surface laser scanning system. Materials and methods: For the present study, thirty adults, who had no severe skeletal discrepancy, were selected and scanned twice by a 3D laser scanner (VIVID 910, Minolta, Tokyo, Japan) with 12 markers placed on the face. Then, two 3D facial images (T1-baseline, T2-30 minutes later) were reconstructed respectably and superimposed in several manners with $RapidForm^{TM}2006$ (Inus, Seoul, Korea) software program. The distances between markers at the same place of face were measured in superimposed 3D facial images and measurement were done all the 12 makers respectably. Results: The average linear distances between the markers at the same place in the superimposed image constructed by upper 2/3 of the face was $0.92{\pm}0.23\;mm$, in the superimposed image constructed by upper 1/2 of the face was $0.98{\pm}0.26\;mm$, in the superimposed image constructed by upper 1/3 of the face and nose area was $0.99{\pm}0.24\;mm$, in the superimposed image constructed by upper 1/3 of the face was $1.41{\pm}0.48\;mm$, and in the superimposed image constructed by whole face was $0.83{\pm}0.13\;mm$. There were no statistically significant differences in the liner distances of the makers placed on the area included in superimposition range used for partial registration methods but there were significant differences in the linear distances of the markers placed on the areas not included in superimposition range between whole registration method and partial registration methods used in this study. Conclusion: The results of the present study suggest that the validity of superimposition is decreased as superimposition range is reduced in the superimposition of 3D images constructed with 3D laser scanner for the same subject.

Changes in Forced Expiratory Volume in 1 Second after Anatomical Lung Resection according to the Number of Segments

  • Lee, Sun-Geun;Lee, Seung Hyong;Cho, Sang-Ho;Song, Jae Won;Oh, Chang-Mo;Kim, Dae Hyun
    • Journal of Chest Surgery
    • /
    • 제54권6호
    • /
    • pp.480-486
    • /
    • 2021
  • Background: Although various methods are already used to calculate predicted postoperative forced expiratory volume in 1 second (FEV1) based on preoperative FEV1 in lung surgery, the predicted postoperative FEV1 is not always the same as the actual postoperative FEV1. Observed postoperative FEV1 values are usually the same or higher than the predicted postoperative FEV1. To overcome this issue, we investigated the relationship between the number of resected lung segments and the discordance of preoperative and postoperative FEV1 values. Methods: From September 2014 to May 2020, the data of all patients who underwent anatomical lung resection by video-assisted thoracoscopic surgery (VATS) were gathered and analyzed retrospectively. We investigated the association between the number of resected segments and the differential FEV1 (a measure of the discrepancy between the predicted and observed postoperative FEV1) using the t-test and linear regression. Results: Information on 238 patients who underwent VATS anatomical lung resection at Kyung Hee University Hospital at Gangdong and by DH. Kim for benign and malignant disease was collected. After applying the exclusion criteria, 114 patients were included in the final analysis. In the multiple linear regression model, the number of resected segments showed a positive correlation with the differential FEV1 (Pearson r=0.384, p<0.001). After adjusting for multiple covariates, the differential FEV1 increased by 0.048 (95% confidence interval, 0.023-0.073) with an increasing number of resected lung segments (R2=0.271, p<0.001). Conclusion: In this study, after pulmonary resection, the number of resected segments showed a positive correlation with the differential FEV1.

Customized maxillary incisor position relative to dentoskeletal and soft tissue patterns in Chinese women: A retrospective study

  • Zhou, Xueman;Zheng, Yingcheng;Zhang, Zhenzhen;Zhang, Zihan;Wu, Lina;Liu, Jiaqi;Yang, Wenke;Wang, Jun
    • 대한치과교정학회지
    • /
    • 제52권2호
    • /
    • pp.150-160
    • /
    • 2022
  • Objective: To provide reliable prediction models based on dentoskeletal and soft tissue variables for customizing maxillary incisor positions and to optimize digitalized orthodontic treatment planning. Methods: This study included 244 Chinese women (age, 18-40 years old) with esthetic profiles after orthodontic treatment with fixed appliances (133 in group I: 1° ≤ The angle between the nasion [N]-A point [A] plane and the N-B point [B] plane [ANB] ≤ 4°; 111 in group II: 4° < ANB ≤ 7°). Dental, skeletal, and soft tissue measurements were performed on lateral cephalograms of the participants. Correlation and multiple linear regression analyses were used to determine the influence of dentoskeletal and soft tissue variables on maxillary incisor position. Results: The ideal anteroposterior position of the maxillary incisor varied between sagittal skeletal patterns. The position of the maxillary incisor correlated with the sagittal discrepancy between the maxilla and the mandible (ANB), protrusion of the midface, nasal tip projection, development of the chin, and inclination of both the maxillary and mandibular incisors. Distance from the maxillary central incisor to nasion-pogonion plane predicted using multiple linear regression analysis was accurate and could be a practical measurement in orthodontic treatment planning. Conclusions: Instead of using an average value or norm, orthodontists should customize a patient's ideal maxillary incisor position using dentoskeletal and soft tissue evaluations.

2.5D 전자선 선량계산 알고리즘 개발 (Development of 2.5D Electron Dose Calculation Algorithm)

  • 조병철;고영은;오도훈;배훈식
    • 한국의학물리학회지:의학물리
    • /
    • 제10권3호
    • /
    • pp.133-140
    • /
    • 1999
  • 본 연구에서는 외부조사 전자선에 대한 3 차원 선량계산 알고리즘 모델을 개발하기 위한 기초연구로서 기존의 2D 펜실빔 알고리즘을 확장시켜 3 차원 geometry를 적절히 고려할 수 있는 선량계산 모델을 개발하고자 한다. 선량계산 모듈은 IDL5.2(Reseach Systems Inc. 미국)를 사용하여 프로그램하였으며, Hogstrom의 펜실빔 모델에 의한 선량계산에 필요한 중심축 상의 깊이선량분포는 Siemens M6740의 12MeV 전자선에 대한 측정치를 사용하였고, 전자선의 공기 및 불에서의 선형저지능 (linear stopping power), 선형산란능 (linear scattering power) 은 ICRU 보고서 35로부터 인용하여 사용하였다. 선량계산의 정확도를 확인하기 위하여 정형 조사면에 대한 선량분포 공기 간격 효과 인체 외곽 보정에 대해 전리함, 필름 등을 사용하여 얻은 측정값과 비교, 분석하였다. PC(Pentium III 450MHz) 상에서 프로그램 실행 결과 단일 조사 빔에 대한 선량계산에 약 120초가 소요되어, 선량계산 알고리즘의 최적화를 통한 선량계산 시간 단축이 필요하다 하겠다. 선량 평가에 대한 비교 결과, 정형 및 비정형 조사변에 대한 선량분포는 선량변화가 급격한 반음영 (penumbra) 영역에서 $\pm$3mm 이내의 오차를 보였으며, 측방 선량분포에 따른 비교 결과, 측정치와 5% 이내에서 일치하였다. 또한 공기 간격 및 인체 외곽선 보정의 경우, $\pm$10% 내외에서 측정값과 일치하였다. 결론적으로, 전자선에 대한 2 차원 펜실빔 모델을 확장하여 3 차원 치료계획에 적합하게 3 차원상의 임의의 단변 선량계산이 가능하도록 구현되었다. 또한 비정형 조사변에 대한 선량계산 뿐만 아니라, 인체외곽 및 공기 간격 등과 같이 3 차원적 geometry에 대한 보정이 필요한 경우에 대하여도 이를 선량계산 시 적절히 고려함을 확인할 수 있었다. 추후, CT를 통한 비균질 보정방식을 구현할 계획이며, 이들 선량계산 모듈은 교육 및 연구용으로 적절히 활용할 수 있을 것으로 기대된다.

  • PDF

6MV 광자선에서 측정 조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교 (The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams)

  • 김회남;박성용;서태석;권수일;윤세철
    • 한국의학물리학회지:의학물리
    • /
    • 제8권2호
    • /
    • pp.87-102
    • /
    • 1997
  • 목적 : 방사선량 측정시 에너지, 매질, 측정기 등의 측정 조건과 측정 프로토콜에 따라 절대 흡수선량값이 결정된다. 본 연구에서는 이러한 측정 조건의 변화와 측정 프로토콜의 차이에 따른 절대 선량 값을 구하여 비교 분석 하고자 한다. 방법 : 시멘스 선형가속기에서 발생하는 6MV 광자선을 이용하여 3개의 다른 매질(물, 고체 물팬텀, 폴리스틸렌팬텀)내에서 2개의 전리함 (PTW ion chamber, NEL ion chamber)과 2개의 전기계(Victoreen electrometer, Keithley electrometer)를 사용하여 흡수선량을 측정하였다. 매질, 전리함, 전기계등의 측정 조건을 달리하여 서로 다른 조합에 대한 측정값을 TG21, IAEA 프로토콜에 의해 각각 분석하였다. 결과 및 결론 : 2개의 전기계와 2개의 전리함 조합에 따른 TG2l 및 IAEA 의 Ngas,, ND값의 비는 평균적으로 1% 이내에서 일치하였다. 3개의 서로 다른 매질, 4개의 서로 다른 전리함 및 전기계 조합에 따른 12 가지 측정조건에 대한 흡수선량의 변화는 평균 0.6%의 차이를 보여 주였으며 임의의 전리함 및 전기계 조합에 대하여 물팬텀 및 고체물팬텀에 대한 TG21, MEA 측정법에 의한 흡수선량비의 변화 양상이 같은 양상을 보여주고 있으나 그 차이가 평균 1.96%를 보임으로서 고체물팬텀이 절대 흡수선량 측정에는 적절치 않은 것으로 사료된다. TG21 측정법에 따른 물팬텀과 폴리스틸렌팬텀을 이용한 절대 흡수선량값이 1.54%의 차이를 보임으로서 팬텀 매질에 대한 비교 factor가 필요할 것으로 사료된다. 측정매질, 전리함, 전기계 등의 여러 조건에 대한 흡수선량값의 차이가 TG21, IAEA 프로토콜에서 1% 이내의 차이를 보여 주고 있으며 상대적인 변화 양상이 측정법에 상관없이 같은 경향으로 변함으로서 측정조건이 측정법에 영향을 주지 않았음을 알 수 있다. 다만 표준 측정법을 사용할 때 팬텀에 의한 차이는 많이 날 수 있으므로 측정법에서 사용하는 표준 팬텀을 사용 할 것을 권장하며 이것이 어려운 경우는 병원에서 사용하는 팬텀에 대한 보정값을 자체적으로 구하여 사용하는 것이 오차를 줄일 수 있을 것으로 사료된다.

  • PDF

선형가속기 ML-15MDX의 각 Applicator에 대한 전자선 출력선량 계수 결정 (Determination of Electron Beam Output Factors of Individual Applicator for ML-15MDX Linear Accelerator)

  • Park, Tae-Jin;Kim, Ok-Bae
    • 한국의학물리학회지:의학물리
    • /
    • 제5권1호
    • /
    • pp.87-99
    • /
    • 1994
  • 목적 : 선형가속기 ML-15MDX의 전자선에너지 대한 출력선량계수가 Applicator크기에 따라 결정되도록 하며 각 Applicator에서 정방형조사면과 직사각형조사변에 대한 출력선량계수는 측정값으로 부터 다항식을 이용하여 결정되었다. 방법 : 실험에서, 출력선량의 측정은 전자선에너지 4, 6, 9, l2MEV대해 2$\times$2$cm^2$에서 20$\times$20$cm^2$까지 이루어졌다. 출력선량계수는 각 아프리케이터의 조사면중심선속의 최대선량에 대한 임의 조사면의 최대선량의 비로 얻어졌고 각 아프리케이터의 출력선량계수는 기준 아프리케이터(10$\times$10$cm^2$)와 비교되었다. 전자선조사면의 차폐는 모든 실험에너지 영역에서 균등하게 10mm 두께의 Lipowitz(밀도 9.4g/$cm^2$)를 사용하였으며, 조사면크기 및 모양 결정이 용이하도록 고안하여 사용되었다. 임의의 전자선조사면에 대한 출력선량계수는 조사면의 한변을 고정한 직사각형의 출력선량 계수를 이용한 1-Dimension방법에 의한 다항식으로 부터 구하였다. 결과 : 직사각형의 전자선조사면에 대한 출력선량계수는 4$\times$4$cm^2$에서 20$\times$20$cm^2$의 범위에서는 2%이내의 불확실성을 보였으며, 이들 보다 작은 직사각형조사면에서는 약 3%의 오차를 보였다. 결론 : 전자선에너지의 정사각형 및 직사각형조사변에 대한 출력선량계수가 실험자료를 이용한 다항식으로 부터 실제값에 매우 근사한 예상값을 얻을 수 있었다.

  • PDF

제주에서 적산온도를 이용한 볼록총채벌레 세대별 발생최성기 예측모형 (Models of Forecasting the Generation Peak Time of Scirtothrips dorsalis (Thysanoptera: Thripidae) adults Based on Degree-days on Jeju Island, Korea)

  • 황록연;현재욱;김동순
    • 한국응용곤충학회지
    • /
    • 제52권4호
    • /
    • pp.415-425
    • /
    • 2013
  • 볼록총채벌레는 제주도 감귤에서 경미한 피해만 보고되다가 2007년부터 다발생하여 그 피해가 갈수록 심각해지고 있다. 본 연구는 적산온도를 이용하여 볼록총채벌레 각 발생세대의 발생최성기를 예측할 수 있는 모형을 개발하고자 수행하였다. 볼록총채벌레 성충 발생세대수를 독립변수(x)로 취급하고 세대별 발생최성기의 적산온도를 종속변수(y)로 취급하여 직선 회귀식을 추정하였다. 감귤원에서 유살된 자료와 녹차 또는 키위과원에서 얻은 자료를 기반으로 각각 감귤기반모형(y = 310.9x + 69.0, $r^2$=0.99) 녹차기반모형(y = 285.7x + 84.1, $r^2$=0.99)을 개발하였다. 각 모형의 예측값과 독립된 포장 실측자료와의 잔차자승합을 토대로 모형의 적합성을 평가하였으며, 녹차기반모형의 적합력이 좋았다. 본 예측모형을 통한 계산값과 실측치의 불일치에 대한 원인과 모형의 포장 활용도에 대하여 고찰하였다.