• 제목/요약/키워드: linear density

검색결과 1,530건 처리시간 0.027초

Piecewise Continuous Linear Density Estimator

  • Jang, Dae-Heung
    • Journal of the Korean Data and Information Science Society
    • /
    • 제16권4호
    • /
    • pp.959-968
    • /
    • 2005
  • The piecewise linear histogram can be used as a simple and efficient tool for the density estimator. But, this piecewise linear histogram is discontinuous function. We suppose the piecewise continuous linear histogram as a simple and efficient tool for the density estimator and the alternative of the piecewise linear histogram.

  • PDF

Design of PM Excited Transverse Flux Linear Motor of Inner Mover Type

  • Kang Do-Hyun;Ahn Jong-Bo;Kim Ji-Won;Chang Jung-Hwan;Jung Soo-Jin
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권2호
    • /
    • pp.137-141
    • /
    • 2005
  • A transverse flux, PM-exited linear motor (TFM-LM) with inner mover was designed and built. Its output power density is higher and its weight is lower than those of the conventional PM exited linear synchronous motors (PM LSM). To obtain the maximum thrust force under the given volume, the thrust force density with respect to the ratio of the slot width and the length of pole pitch is analyzed by the 3-dimension finite element method (FEM). Finally, calculated static thrust forces was compared with the experimental values. The calculated and measured performance of the transverse flux, PM-exited linear motor with inner mover revealed great potential for system improvements by reducing the mass of the linear motor. For examples, when this motor was applied to a ropeless elevator, it was possible to increase the power density by more than 400% over the conventional PM-LSM. The results of this study recommend this type of motor for the ropeless elevator or gearless direct linear driving system.

등가자기회로를 이용한 리니어모터의 추력밀도계산 (Calculation of Force Density in Linear Motor Using Equivalent Magnetic Circuit)

  • 홍정표;강도현;주수원;한성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.96-98
    • /
    • 2001
  • In this paper, the equivalent magnetic circuit and FEM are used to calculate force density of linear BLDC motor. The equivalent magnetic circuit is hard to exact compose for analysis model and it is just applied to linear system. To flexible design and reducing the calculated and analyzed time, magnetic circuit has to be used for designing the linear BLDC motor and deducing equation of force density. Force density as parameter of permanent magnet and coil-side width that are important to determined force density can be estimated using equation of force density. FEM is used to prove reliability of equation of force density and to consider the nonlinear system. Equivalent magnetic circuit and result of FEM are similar, but it is little different by friction loss at the experiment.

  • PDF

Bayes Prediction Density in Linear Models

  • Kim, S.H.
    • Communications for Statistical Applications and Methods
    • /
    • 제8권3호
    • /
    • pp.797-803
    • /
    • 2001
  • This paper obtained Bayes prediction density for the spatial linear model with non-informative prior. It showed the results that predictive inferences is completely unaffected by departures from the normality assumption in the direction of the elliptical family and the structure of prediction density is unchanged by more than one additional future observations.

  • PDF

Robustness of Minimum Disparity Estimators in Linear Regression Models

  • Pak, Ro-Jin
    • Journal of the Korean Statistical Society
    • /
    • 제24권2호
    • /
    • pp.349-360
    • /
    • 1995
  • This paper deals with the robustness properties of the minimum disparity estimation in linear regression models. The estimators defined as statistical quantities whcih minimize the blended weight Hellinger distance between a weighted kernel density estimator of the residuals and a smoothed model density of the residuals. It is shown that if the weights of the density estimator are appropriately chosen, the estimates of the regression parameters are robust.

  • PDF

Modified Local Density Estimation for the Log-Linear Density

  • Pak, Ro-Jin
    • Communications for Statistical Applications and Methods
    • /
    • 제7권1호
    • /
    • pp.13-22
    • /
    • 2000
  • We consider local likelihood method with a smoothed version of the model density in stead of an original model density. For simplicity a model is assumed as the log-linear density then we were able to show that the proposed local density estimator is less affected by changes among observations but its bias increases little bit more than that of the currently used local density estimator. Hence if we use the existing method and the proposed method in a proper way we would derive the local density estimator fitting the data in a better way.

  • PDF

밸브구동용 선형 포스모터 설계를 위한 해석 연구 (A Study of Analyzing for Design of a Linear Force Motor for Hydraulic Valve)

  • 박창순;허준영
    • 유공압시스템학회논문집
    • /
    • 제8권1호
    • /
    • pp.26-31
    • /
    • 2011
  • To drive hydraulic valve is used Linear force motor, whose force and direction are controlled by electronic signals. Linear force motor has complicated figure and its force produced by changing of flux density which is produced by permanent magnet and electrical winding. Therefore it is needed an exact calculation of the flux density. In this paper a Linear force motor is designed and analysed by 3d program Flu calculating the flux density in air gap and in yoke, Force by different current. The analysed data will be tested by prototype Linear force motor. The data and analysing method can be used for designing Linear force motor.

휴대용 파워팩을 위한 소형 세라믹 리니어 엔진 설계 및 동적 특성에 관한 연구 (A Study of Design and Dynamic Characteristics of Compact Linear Engine for Porable Powerpack)

  • 오용일;김강출;임옥택
    • 한국수소및신에너지학회논문집
    • /
    • 제22권4호
    • /
    • pp.512-519
    • /
    • 2011
  • Current rechargeable battery cannot provide high energy density and the operational durations required. But linear engine/generators provide high energy density for portable power applications because fuel is more high density. In this paper, we suggest that basic design of powerpack using linear engine for assisting power output. Efficiency is relatively high because linear engine don't have crank mechanism compared with rotary engine. We made prototype engine and had experiments to know moving characteristic about the Linear Engine. It was possible to operate velocity at 50 Hz at the firing and pressure in cylinder was 16bar.

Design and Analysis of a Dual-Stator Spoke-Type Linear Vernier Machine for Wave Energy Extraction

  • Khaliq, Salman;Kwon, Byung-il
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1700-1706
    • /
    • 2016
  • In this paper, a dual-stator, spoke-type linear vernier machine (DSSLVM) for wave energy extraction application was proposed. This machine is capable of producing a competitively high thrust force and force density at a low operation speed in direct drive systems. The operation principal and working of the proposed DSSLVM were studied. The stator core height is adjusted to improve the overall force density of the proposed machine while reducing the force ripple. To evaluate the advantages of the proposed DSSLVM, the main performance was compared with that of a recently developed linear primary permanent magnet vernier machine (LPPMVM). The proposed machine exhibited greater thrust force and force density, an improved power factor and lower force ripple with the same permanent magnet (PM) volume compared to the LPPMVM.

도시고속도로의 진입연결로 접속부내 선형의 밀도예측모형 구축에 관한 연구 (The Linear Density Predictive Models on the On-Ramp Junction in the Urban Freeway)

  • 김태곤;신광식;김승길;김정서
    • 대한토목학회논문집
    • /
    • 제26권1D호
    • /
    • pp.59-66
    • /
    • 2006
  • 이 연구는 도시고속도로의 진입연결로 접속부내 선형의 밀도예측모형 구축에 관한 연구로서 실시간 교통특성분석과 선형의 밀도예측모형 구축 및 검증을 통해 밀도예측모형 구축에 있어서 결정계수($R^2$)값이 대체적으로 0.7이상으로 나타나 선형회귀모형구축에 상당히 높은 설명력을 보이는 것으로 나타났고, 선형모형검증에 있어서 상관계수(r)값도 대체적으로 0.8 이상으로 상당히 높은 상관성을 보이는 것으로 나타났다. 따라서 향후 선형의 밀도예측모형을 이용하여 도시고속도로의 진입연결로 접속부내 차량의 밀도추정 및 지체분석에 상당히 유효할 것으로 판단된다.