• 제목/요약/키워드: linear accelerometer

검색결과 49건 처리시간 0.029초

ON-LINE DYNAMIC SENSING OF SHIP'S ATTITUDE BY USE OF A SERVO-TYPE ACCELEROMETER AND INCLINOMETERS

  • Tanaka, Shogo;Nishifuji, Seiji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.162-165
    • /
    • 1995
  • For an accurate on-line measurement of the ship's attitude the paper develops an intelligent sensing system which uses one servo-type accelerometer and two servo-type inclinometers appropriately located on the ship. By considering the dynamics of the servo-controlled rigid pendulums of the inclinometers, linear equations for the rolling and pitching of the ship are derived separately from each other. Moreover, one accelerometer is used for extracting the heaving signal. Through the introduction of linear dynamic models and the linear observation equations for the heaving, rolling and pitching, the on-line measurement of the three signals can be reduced to the state estimation of the linear dynamic systems. A bank of Kalman filters is adaptively used to achieve the on-line accurate state estimation and to overcome changes in parameters in the linear dynamic models.

  • PDF

Piezoelectric 6-dimensional accelerometer cross coupling compensation algorithm based on two-stage calibration

  • Dengzhuo Zhang;Min Li;Tongbao Zhu;Lan Qin;Jingcheng Liu;Jun Liu
    • Smart Structures and Systems
    • /
    • 제32권2호
    • /
    • pp.101-109
    • /
    • 2023
  • In order to improve the measurement accuracy of the 6-dimensional accelerometer, the cross coupling compensation method of the accelerometer needs to be studied. In this paper, the non-linear error caused by cross coupling of piezoelectric six-dimensional accelerometer is compensated online. The cross coupling filter is obtained by analyzing the cross coupling principle of a piezoelectric six-dimensional accelerometer. Linear and non-linear fitting methods are designed. A two-level calibration hybrid compensation algorithm is proposed. An experimental prototype of a piezoelectric six-dimensional accelerometer is fabricated. Calibration and test experiments of accelerometer were carried out. The measured results show that the average non-linearity of the proposed algorithm is 2.2628% lower than that of the least square method, the solution time is 0.019382 seconds, and the proposed algorithm can realize the real-time measurement in six dimensions while improving the measurement accuracy. The proposed algorithm combines real-time and high precision. The research results provide theoretical and technical support for the calibration method and online compensation technology of the 6-dimensional accelerometer.

힐버트-황 변환에 통한 Hand Accelerometer 데이터의 핵심 패턴 추출 (Applying Hilbert-Huang Transform to Extract Essential Patterns from Hand Accelerometer Data)

  • 최병석;서정열
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권2호
    • /
    • pp.179-190
    • /
    • 2017
  • Hand Accelerometer는 인간신체 운동 패턴을 실시간으로 파악하는데 널리 사용되고 있다. 그러므로 행동 유형을 정확하게 파악하는 것은 아주 중요하다. 이 과정에서 각 행동유형의 형태를 미리 정확하게 파악하는 것이 중요하다. 인간의 신체 행동은 센서를 통해 수집된 시계열 데이터로 표현된다. 이 데이터는 비안정적, 비선형적 성격을 가지고 있다. 그래서 이런 성격의 데이터의 유형을 효율적으로 추출하는 방법을 찾는 것은 매우 중요하다. 힐버트-황 변환은 비안정적 비선형적 요소를 시계열데이터에서 효율적으로 추출하는 방법이다. 이 방법을 위의 시계열 데이터에 적용한 결과 핵심패턴이 성공적으로 추출되었다.

사용 중 지진 가속도계의 정상 측정과 출력전압 선형비 오차율 관계 분석 (Relationship between Normal Measurement and Error Rate of Output Voltage Linear Ratio of Seismic Accelerometer in Use)

  • 김민준;조성철;정용훈;원정훈
    • 한국안전학회지
    • /
    • 제39권2호
    • /
    • pp.65-74
    • /
    • 2024
  • We analyzed the relationship between the normal measurement of the seismic accelerometer (SA) and the error rate of the output voltage linear ratio to propose an evaluation method to determine whether the SA in use is measuring normally. Utilizing a test bed, the regular operation of SA in use was evaluated using acceleration data measured through impact tests since there are no regulations regarding performance testing of SA in use. For the used SA, the error rate of the output voltage linear ratio, which is a major performance criterion, was evaluated. We analyzed common characteristics of the SA that satisfied the impact test and the performance criteria of the output voltage linear ratio error rate. The results indicated that we must consider the decreasing trend and convergence of the error rate as the measurement angle increases, ensuring that the average value of the output voltage linear ratio error rate is within 1%.

GPS와 가속도계를 이용한 구조물 거동모니터링의 타당성 연구 (Feasibility Study of Structural Behavior Monitoring Using GPS and Accelerometer)

  • 한정헌;류성찬;조두용;박선규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권3호
    • /
    • pp.11-22
    • /
    • 2012
  • 본 연구는 RTK-GPS (Real Time Kinematic-Global Positioning System) 측위법을 이용한 변위 계측 결과, 가속도계를 이용한 변위계측 결과, 그리고 LVDT(Linear variable differential transformer)의 변위계측 결과를 비교하여 RTK-GPS와 가속도계 센서를 구조물에 적용할 때의 문제점들을 파악하였다. 또한, 관측빈도와 측위 정확도를 향상시킨 RTK-GPS와 가속도계를 이용한 변위계측 결과를 통합 계산하여 절대변위인 LVDT와 비교를 통해 생성된 통합 변위의 정확도와 타당성을 확인하였다.

자기부상 시스템의 디지털 제어 (Digital Control of an Electromagnetic Levitation System)

  • 이승욱;이건복
    • 대한기계학회논문집
    • /
    • 제18권9호
    • /
    • pp.2312-2321
    • /
    • 1994
  • In this work the dynamics of an electromagnetic levitation system is described by a set of three first order nonlinear ordinary differential equations. The objective is to design a digital linear controller which takes the inherent instability of the uncontrolled system and the disturbing force into consideration. The controller is made by employing digital linear quadratic(LQ) design methodology and the unknown state variables are estimated by the kalman filter. The state estimation is performed using not only an air gap sensor but also both an air gap sensor and a piezoelectric accelerometer. The design scheme resulted in a digital linear controller having good stability and performance robustness in spite of various modelling errors. In case of using both a gap sensor and an accelerometer for the state estimation, the control input was rather stable than that in a system with gap sensor only and the controller dealt with the disturbing force more effectively.

관성 센서를 이용한 휴머노이드 로봇용 3축 자세 추정 알고리듬 개발 (Development of 3-Dimensional Pose Estimation Algorithm using Inertial Sensors for Humanoid Robot)

  • 이아람;김정한
    • 제어로봇시스템학회논문지
    • /
    • 제14권2호
    • /
    • pp.133-140
    • /
    • 2008
  • In this paper, a small and effective attitude estimation system for a humanoid robot was developed. Four small inertial sensors were packed and used for inertial measurements(3D accelerometer and three 1D gyroscopes.) An effective 3D pose estimation algorithm for low cost DSP using an extended Kalman filter was developed and evaluated. The 3D pose estimation algorithm has a very simple structure composed by 3 modules of a linear acceleration estimator, an external acceleration detector and an pseudo-accelerometer output estimator. The algorithm also has an effective switching structure based on probability and simple feedback loop for the extended Kalman filter. A special test equipment using linear motor for the testing of the 3D pose sensor was developed and the experimental results showed its very fast convergence to real values and effective responses. Popular DSP of TMS320F2812 was used to calculate robot's 3D attitude and translated acceleration, and the whole system were packed in a small size for humanoids robots. The output of the 3D sensors(pitch, roll, 3D linear acceleration, and 3D angular rate) can be transmitted to a humanoid robot at 200Hz frequency.

Gyroscope Free 관성 항법 장치의 데이터 보정을 위한 퍼지 추론 시스템 (Fuzzy Inference System for Data Calibration of Gyroscope Free Inertial Navigation System)

  • 김재용;김정민;우승범;김성신
    • 한국지능시스템학회논문지
    • /
    • 제21권4호
    • /
    • pp.518-524
    • /
    • 2011
  • 본 논문은 퍼지 추론 시스템(FIS: fuzzy inference system)을 이용하여 자이로스코프를 사용하지 않는 관성 항법 장치(GFINS: gyroscope free inertial navigation system)의 가속도계 데이터를 보정하는 방법에 관한 연구이다. 일반적인 관성항법 장치(INS: inertial navigation system)는 주로 가속도계와 같은 병진운동을 감지하는 관성 센서와 자이로스코프와 같은 회전 운동을 감지하는 관성 센서를 이용하여 위치와 yaw각을 측정하는 장치이다. 하지만 INS는 자이로스코프를 사용하기 때문에 소형화 및 저전력 설계가 어렵다. 이러한 문제를 해결하기 위하여 자이로스코프를 사용하지 않는 GFINS에 대한 연구가 활발히 진행되고 있다. GFINS에 사용되는 가속도계는 적분과 외란에 의한 오차가 시간이 지남에 따라 누적되는 문제가 있다. 따라서 본 논문에서는 가속도계의 누적 오차 문제를 해결하기 위해, 레이저 내비게이션과 가속도계의 선속도 비율과 엔코더와 가속도계의 선속도 비율을 통해 GFINS의 데이터를 보정하는 FIS를 제안한다. 제안된 Fuzzy-GFINS를 평가하기 위해, 직접 제작한 메카넘 휠 AGV(autonomous ground vehicle)에 제안된 GFINS를 적용하였다. 실험 결과, 제안된 방법이 GFINS의 출력 데이터를 효과적으로 보정하는 것을 확인 할 수 있었다.

범프 본딩된 압저항 실리콘 가속도센서의 제조 (Fabriaction of bump bounded piezoresistive silicon accelerometer)

  • 심준환;이상호;이종현
    • 전자공학회논문지D
    • /
    • 제34D권7호
    • /
    • pp.30-36
    • /
    • 1997
  • Bump bonded piezoesistive silicon accelerometer was fabricated by the porous silicon micromachining and th eprocess technique of integrated circuit. The output voltage of the accelerometer fabricated on (111)-oreiented Si substrates with n/n$^{+}$n triple layers showed good linear characteristic of less than 1%. The measured sensitivity and the resonant frequency was about 743 .mu.V/g and 2.04 kHz, respectively. And the transverse sensitivity of 5.2% was measured from the accelerometer. Also, to investigate an influence on the output characteristics of the sensor due to bump bonding, the values of the piezoresistors were measured through thermal-cycling test in the temperature variation form -50 to 120.deg. C. Then, there was 0.014% resistance changes about 3.61 k.ohm., so sthe output charcteristics of the sensor was less affected by bump bonding.g.

  • PDF

관성센서를 이용한 PC 입력장치 개발 (PC Input Device Using Inertial Sensor)

  • 진용;이준호;박찬국
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.79-79
    • /
    • 2000
  • In this Paper, the PC input device using MEMS gyros and accelerometer is newly developed, so that it can measure rotation rate and linear acceleration of the human body in space. In General, the human motion has 6 degree of freedom but 2 degree of freedom is enough PC monitor with 2D display. Therefore the simple method is proposed to achieve minimum degree of freedom. It is also applied to the PC mouse. This method can be expanded to the input device for internet set-top box or internet TV.

  • PDF