• Title/Summary/Keyword: line-scanning method

Search Result 181, Processing Time 0.032 seconds

Effect of Radiation Dosage Changes on the Cell Viability and the Apoptosis Induction on Normal and Tumorigenic Cells (방사선의 선량변화가 수종의 정상세포와 종양세포주의 세포활성도와 apoptosis 유발에 미치는 영향)

  • Park In-Woo;Lee Sam-Sun;Heo Min-Suk;Choi Soon-Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.435-449
    • /
    • 1999
  • Purpose : The study was aimed to detect the differences in the cell viability and the apoptosis induction after irradiation on normal and tumorigenic cells. Materials and Methods : The study. that was generated for two human normal cells(RHEK, HGF-l) and two human tumor cells(KB. HT-1080). was tested using MTT assay at 1 day and 3 day after irradiation and TUNEL assay under confocal laser scanning microscope at 1 day after irradiation. Single irradiation of 0.5. 1, 2. 4. and 8Gy were applied to the cells. The two fractions of 1. 2. 4. and 8Gy were separated with a 4-hour time interval. The irradiation was done with 5.38Gy/min dose rate using Cs-137 irradiator at room temperature. Results and Conclusions : 1. In 3-day group. the cell viability of HGF-1 cell was significantly decreased at 2. 4 and 8Gy irradiation, the cell viability of KB cell was significantly decreased at 8Gy irradiation and the cell viability of HT-I080 cell was significantly decreased at 4 and 8Gy irradiation. 2. There was significant difference between RHEK and KB cell line in the cell viability of 3-day group at 8Gy irradiation. There was significant difference between RHEK and HGF-1 cell line in the cell viability of 3-day group at 4 and 8Gy irradiation. 3. There was a significantly decreased cell viability in 3-day group than those in 1-day group at 2. 4 and 8Gy on HGF-1 cell. at 4 and 8Gy on HT-I080 cell. at 8Gy on KB cell. 4. We could detect DNA fragmented cells only on KB cell. Number of apoptotic cells of KB cell was significantly increased at 4 and 8Gy irradiation. However, there was no correlation between cell viability and apoptosis. 5. On all 4 cell lines, there were no differences between single and split irradiation method in cell viability and apoptosis.

  • PDF

Influence of finish line design on the marginal fit of nonprecious metal alloy coping fabricated by 3D printing, milling and casting using CAD-CAM (CAD-CAM을 이용한 3D printing, milling, casting 방법의 비귀금속 코핑의 지대치 변연 적합도 연구)

  • Seo-Rahng Kim;Myung-Joo Kim;Ji-Man Park;Seong-Kyun Kim;Seong-Joo Heo;Jai-Young Koak
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.1-17
    • /
    • 2023
  • Purpose. The purpose of this study was to examine the correlation between the finish line designs and the marginal adaptation of nonprecious metal alloy coping produced by different digital manufacturing methods. Materials and methods. Nonprecious metal alloy copings were made respectively from each master model with three different methods; SLS, milling and casting by computer aided design and computer aided manufacturing (CAD-CAM). Twelve copings were made by each method resulting in 72 copings in total. The measurement was conducted at 40 determined reference points along the circumferential margin with the confocal laser scanning microscope at magnification ×150. Results. Mean values of marginal gap of laser sintered copings were 11.8 ± 7.4 ㎛ for deep chamfer margin and 6.3 ± 3.5 ㎛ for rounded shoulder margin and the difference between them was statistically significant (P < .0001). Mean values of marginal gap of casted copings were 18.8 ± 20.2 ㎛ for deep chamfer margin and 33 ± 20.5 ㎛ for rounded shoulder margin and the difference between them was significant (P = .0004). Conclusion. Within the limitation of this study, the following conclusions were drawn. 1. The variation of finish line design influences the marginal adaptation of laser sintered metal coping and casted metal coping. 2. Laser sintered copings with rounded shoulder margin had better marginal fit than deep chamfer margin. 3. Casted copings with deep chamfer margin had better marginal fit than rounded shoulder margin. 4. According to the manufacturing method, SLS system showed the best marginal fit among three different methods. Casting and milling method followed that in order.

Evaluation of the Accuracy of Distance Measurements on 3D Volume-rendered Image of Human Skull Using Multi-detector CT: Effects of Acquisition Section Thickness and Reconstruction Section Thickness

  • Haijo Jung;Kim, Hee-Joung;Lee, Sang-Ho;Kim, Dong-Wook;Soonil Hong;Kim, Dong-Hyeon;Son, Hye-Kyung;Wonsuk Kang;Kim, Kee-Deog
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.457-460
    • /
    • 2002
  • The image quality of three-dimensional (3D) images has been widely investigated by the qualitative analysis method. A need remains for an objective and quantitative method to assess the image quality of 3D volume-rendered images. The purpose of this study was to evaluate the quantitative accuracy of distance measurements on 3D volume-rendered images of a dry human skull by using multi-detector computed tomography (MDCT). A radiologist measured five times the twenty-one direct measurement line items composed among twelve reference points on the skull surface with a digital vernier caliper. The water filled skull specimen was scanned with a MDCT according to the section thicknesses of 1.25, 2.50, 3.75, and 5.00 mm for helical (high quality; pitch 3:1) scan mode. MDCT data were reconstructed with its acquisition section thickness and with 1.25 mm section thickness for all scans. An observer also measured seven times the corresponding items on 3D volume-rendered images with measuring tools provided by volumetric analysis software. The quantitative accuracy of distance measurements on the 3D volume-rendered images was statistically evaluated (p-value < 0.05) by comparatively analyzing these measurements with the direct distance measurements. The accuracy of distance measurements on the 3D volume-rendered MDCT images acquired with 1.25, 2.50, 3,75 and 5.00 mm section thickness and reconstructed with its section thickness were 48%, 33%, 23%, and 14%, respectively. Meanwhile, there were insignificant statistical differences in accuracy of distance measurements among 3D volume-rendered images reconstructed with 1.25 mm section thickness for the each acquisition section thickness. MDCT images acquired with thick section thickness and reconstructed with thin section thickness in helical scan mode should be effectively used in medical planning of 3D volume-rendered images. The quantitative analysis of distance measurement may be a useful tool for evaluating the quantitative accuracy and the defining optimal parameters of 3D volume-rendered CT images.

  • PDF

Finite Element Simulation of Laser-Generated Ultrasound and Interaction with Surface Breaking Cracks (유한요소법을 이용한 레이저 유도 초음파와 표면 균열과의 상호작용 모델링)

  • Jeong, Hyun-Jo;Park, Moon-Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • A finite element method is used to simulate interaction of laser-based ultrasounds with surface breaking tracks in elastic media. The laser line source focused on the surface of semi-infinite medium is modeled as a shear dipole in 2-D plane strain finite elements. The shear dipole-finite clement model is found to give correct directivity patterns for generated longitudinal and shear waves. The interaction of surface waves with surface breaking cracks (2-D machined slot) is considered in two ways. Both the source and receiver are fixed with respect to the cracks in the first case, while the source is moving in another case. It is shown that the crack depth tested in the range of 0.3-5.0mm $({\lambda}_R/d=0.21{\sim}3.45)$ can be measured using the corner reflected waves produced by the fixed laser source. The moving laser source is found to cause a large amplitude change of reflected waves near crack, and the crack whose depth is one order lower than the wavelength ran be detected from this change.

Sensitive High-Resolution Melting Analysis for Screening of KRAS and BRAF Mutations in Iranian Human Metastatic Colorectal Cancers

  • Niya, Mohammad Hadi Karbalaie;Basi, Ali;Koochak, Aghigh;Tameshkel, Fahimeh Safarnezhad;Rakhshani, Nasser;Zamani, Farhad;Imanzade, Farid;Rezvani, Hamid;Adib sereshki, Mohammad Mahdi;Sohrabi, Masoud Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.12
    • /
    • pp.5147-5152
    • /
    • 2016
  • Background: Investigations of methods for detection of mutations have uncovered major weaknesses of direct sequencing and pyrosequencing, with their high costs and low sensitivity in screening for both known and unknown mutations. High resolution melting (HRM) analysis is an alternative tool for the rapid detection of mutations. Here we describe the accuracy of HRM in screening for KRAS and BRAF mutations in metastatic colorectal cancer (mCRCs) samples. Materials and Methods: A total of 1000 mCRC patients in Mehr Hospital, Tehran, Iran, from Feb 2008 to May 2012 were examined for KRAS mutations and 242 of them were selected for further assessment of BRAF mutations by HRM analysis. In order to calculate the sensitivity and specificity, HRM results were checked by pyrosequencing as the golden standard and Dxs Therascreen as a further method. Results: In the total of 1,000 participants, there were 664 (66.4%) with wild type and 336 (33.6%) with mutant codons 12 and/or 13 of the KRAS gene. Among 242 samples randomly checked for the BRAF gene, all were wild type by HRM. Pyrosequencing and Dxs Therascreen results were in line with those of the HRM. In this regard, the sensitivity and specificity of HRM were evaluated as 100%. Conclusion: The findings suggest that the HRM, in comparison with DNA sequencing, is a more appropriate method for precise scanning of KRAS and BRAF mutations. It is also possible to state that HRM may be an attractive technique for the detection of known or unknown somatic mutations in other genes.

Analysis of Geospatial Information Construction Efficiency by 3D Laser Scanner Integrated with Total Station (3D 레이저 스캐너와 토털스테이션 통합에 의한 공간정보 구축의 효율성 분석)

  • Park, Joon-Kyu;Lee, Keun-Wang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.638-643
    • /
    • 2017
  • The 3D laser scanner operates by measuring the distance from the sensor to the target and operates on the same principle as Electronic Distance Measuring (EDM). Recently, 3D laser scanning technology has been rapidly developed in line with the strongly increasing demand for 3D information acquisition. Therefore, it is now possible to more easily acquire geometric information of various objects existing in real space. In this study, we constructed geospatial information by using new equipment which integrated 3D laser scanner and total station, and we suggest the possibility of using new technology for geospatial information construction by comparing and analyzing with existing methods. In the study result, we demonstrated the efficiency of the geospatial information constructed by integration of 3D laser scanner and total station. The proposed method is expected to shorten the time required for data acquisition compared to the existing method using the existing total station. Furthermore, it is possible to use various methods such as cross section analysis and volume calculation using the acquired data. In the future, spatial information construction by integration of 3D laser scanner and total station will help improve work efficiency in related fields.

The Development of Image Processing System Using Area Camera for Feeding Lumber (영역카메라를 이용한 이송중인 제재목의 화상처리시스템 개발)

  • Kim, Byung Nam;Lee, Hyoung Woo;Kim, Kwang Mo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.37-47
    • /
    • 2009
  • For the inspection of wood, machine vision is the most common automated inspection method used at present. It is required to sort wood products by grade and to locate surface defects prior to cut-up. Many different sensing methods have been applied to inspection of wood including optical, ultrasonic, X-ray sensing in the wood industry. Nowadays the scanning system mainly employs CCD line-scan camera to meet the needs of accurate detection of lumber defects and real-time image processing. But this system needs exact feeding system and low deviation of lumber thickness. In this study low cost CCD area sensor was used for the development of image processing system for lumber being fed. When domestic red pine being fed on the conveyer belt, lumber images of irregular term of captured area were acquired because belt conveyor slipped between belt and roller. To overcome incorrect image merging by the unstable feeding speed of belt conveyor, it was applied template matching algorithm which was a measure of the similarity between the pattern of current image and the next one. Feeding the lumber over 13.8 m/min, general area sensor generates unreadable image pattern by the motion blur. The red channel of RGB filter showed a good performance for removing background of the green conveyor belt from merged image. Threshold value reduction method that was a image-based thresholding algorithm performed well for knot detection.

Errors of Surface Image Due to the Different Tip of Nano-Indenter (나노인덴터 압입팁의 특성에 따른 표면 이미지 오차 연구)

  • Kim, Soo-In;Lee, Chan-Mi;Lee, Chang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.5
    • /
    • pp.346-351
    • /
    • 2009
  • Due to the decrease of line width and increase of the integration level of the device, it is expected that 'Bottom-up' method will replace currently used 'Top-down' method. Researches about 'Bottom-up' device production such as Nanowires and Nanobelts are widely held on. To utilize these technologies in devices, properties of matter should be exactly measured. Nano-indenters are used to measure the properties of nano-scale structures. Additionally, Nano-indenters provide AFM(Atomic Force Microscopy) function to get the image of the surface and get physical properties for exact position of nano-structure using this image. However, nano-indenter tips have relatively much bigger size than ordinary AFM probes, there occurs considerable error in surface image by Nano-Indenter. Accordingly, this research used 50nm Berkovich tip and 1um $90^{\circ}$ Conical tip, which are commonly used in Nano-Indenter. To find out the surface characteristics for each kind of tip, we indented the surface of thin layer by each tip and compared surface image and indentation depth. Then, we got image of 100nm-size structure by surface scanning using Nano-Indenter and compared it with surface image gained by current AFM technology. We calculated the errors between two images and compared it with theoretical error.

Microstructural Change of Implant Surface conditioned with Tetracycline-HCI;SLA and TB surface implant (표면처리 시간에 따른 임플란트 미세구조의 변화;SLA와 TB 표면 임플란트)

  • Woo, Jung-A;Herr, Yeek;Kwon, Young-Hyuk;Park, Joon-Bong;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.921-937
    • /
    • 2005
  • Mechanical and chemical methods are the two ways to treat the implant surfaces. By using mechanical method, it is difficult to eliminate bacteria and by-products from the rough implant surface and it can also cause the structural change to the implant surface. Therefore, chemical method is widely used in order to preserve and detoxicate the implant surface more effectively. The purpose of this study is to evaluate the effect of tetracylcline- HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, SLA surface and $TiO_2blasted$ surface were used in this study. Implant surface was rubbed with sponge soaked in 50mg/ml tetracycline - HCl solution for $\frac{1}{2}$ min., 1min., $1\frac{1}{2}$ min., 2 min., and $2\frac{1}{2}min.$ respectively in the test group and with no treatment in the control group. The sponge was soaked in every 30 seconds. Then, the specimens were processed for scanning electron microscopic observation. Based upon the analysis of photographs by three dentists who are not related with this study, the results were obtained as follows; 1. In the pure titanium machined surfaces, the control specimen showed a more or less rough machined surface composed of alternating positive and negative lines corresponding to grooves and ridges. After treatment, machining line was more pronounced for the control specimens. but in general, test specimens were similar to control. 2. In the SLA surfaces, the control specimen showed that the macro roughness was achieved by large-grit sandblasting. Subsequently, the acid-etching process created the micro roughness, which thus was superimposed on the macro roughness. Irrespective of the application time of 50mg/ml tetracycline - HCl solution, in general, test specimens were similar to control. 3. In the $TiO_2blasted$ surfaces, the control specimen showed the rough surface With small pits. The irregularity of the $TiO_2blasted$ surfaces with 50mg/ml tetracycline - HCl solution was lessened and the flattened areas got wider after 1 minute.

Effects of Cryptotympana pustulata on the expression of cytokine genes in human monocytes of THP-1 (선퇴가 인간의 THP-1 단핵구에서 사이토카인 유전자 발현에 미치는 영향)

  • An, Jong-Hyun;Kim, Kyung-Jun
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.23 no.1
    • /
    • pp.94-110
    • /
    • 2010
  • Objective : This study was performed to evaluate the effect of immune reaction inductive substances such as phorbol-myristate-acetate(PMA), lipopolysaccharide(LPS), dermato-phagoides pteronyssus crude extract(DPE), dinitrochloro-benzene(DNCB) and Cryptotympana pustulata(CP), the Cryptotympana pustulata extracting substance at simultaneously on the translocation of nuclear factor-kappa B(NF-${\kappa}B$) towards to the nucleus and the mRNA expression patterns of various cytokine genes in Human acute monocytic leukemia cell line(THP-1 cells), monocytes of human. Experiment : To analyze cytokine genes expression patterns, the RT-PCR method was used, measuring tumor necrosis factor(TNF)-$\alpha$ that had been secreted during cell culture in the ELISA method. The morphological change in the cell observed during THP-1 cell culture was observed using a scanning electron microscope (SEM) and the quantitative distribution in the cell NF-${\kappa}B$ was analyzed through immunocytochemistry and a confocal microscopy. Result : CP showed different influences onto the mRNA expression patterns of cytokine genes with PMA, LPS. DPE and DNCB according to the types of immune inductive substances in the THP-1 cells. The expressions of inter-leukin(IL)-10, interferon(INF)-$\gamma$, TNF-$\alpha$ and monocyte chemoattractantant protein(MCP)-1 induced by PMA were suppressed by CP while the expression of transforming growth factor(TGF)-$\beta$ was promoted. Regarding the secretion pattern of TNF-$\alpha$ according to PMA processing, its secretion amount was increased by CP concurrent processing, in case of processing CP onto PMA and LPS, We discovered that the secretion amount of TNF-$\alpha$ was increased. Upon processing PMA and LPS on the THP-1 cell strain at the same time or either additionally processing CP thereon, the movement increase towards the nucleus from the NF-${\kappa}B$ cell cytoplasm, a transcription factor was able to be observed. Conclusion : In this study, Cryptotympana pustulata extracting substance was confirmed that it had an influence on expression patterns of cytokine genes according to the actions of a variety kinds of immune reaction inductive substances processed on the monocyte THP-1 cell of humans. Therefore, additional studies as for the immune adjusting function of Cryptotympana pustulata are considered to be able to offer important materials for curing immune abnormal diseases such as atopy dermatitis afterward.