• Title/Summary/Keyword: line-heating

Search Result 378, Processing Time 0.026 seconds

CLSM Analysis of Change in Roughness and Physical Properties of Granite after Freeze-Thaw Experiments (CLSM을 이용한 동결/융해 실험 후 화강암 시료의 표면 및 물성변화 분석)

  • Jeong, Jongtaek;Choi, Junghae;Chae, Byung-Gon;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.23 no.3
    • /
    • pp.271-281
    • /
    • 2013
  • Freeze-thaw experiments were conducted to evaluate changes in surface roughness and physical properties in samples of granite from Ilgwang and Imki mines, Korea. The temperature range in the experiments was $-20^{\circ}C$ to $40^{\circ}C$, based on typical summer and winter temperatures in Korea, and the surface was observed every 20 cycles. One cycle comprised 1 hour of heating or cooling of the samples and 1 hour during which the target temperature was maintained. With increasing repetitions of the freeze-thaw experiment, porosity increased by 0.05%-0.15% in the two samples and the dry weight increased, whereas the volume of the soil and saturation weight decreased. Observations by confocal laser scanning microscope (CLSM) revealed that line and surface roughness parameters showed a tendency to increase and decrease, respectively, with elapsed time. Changes in surface roughness were apparent on the CLSM images.

Evaluation of HACCP system implementation in meat packaging industry (식육포장처리업의 HACCP 운용실태 분석)

  • Kang, Cheon-Kun;Hong, Chong-Hae
    • Korean Journal of Veterinary Service
    • /
    • v.36 no.4
    • /
    • pp.291-296
    • /
    • 2013
  • The purpose of this study was to determine food safety practices and procedures based on Hazard Analysis Critical Control Point (HACCP) system and to suggest more effective method of HACCP implementation in meat packaging industry in Korea. We used the non-compliance rate of each evaluation item to compare the weak points of prerequisite requirements and HACCP. The prerequisite items related to facility, equipment, and tools showed inadequate level of requirements or unsanitary conditions for proper HACCP operation. A lack of understanding of sanitation standard operation procedures was identified as a fundamental barrier to HACCP implementation. High rate of non-compliance in HACCP items compared to prerequisite requirements signify that small businesses have potential difficulties of applying HACCP due to lack of technical expertise, financial resources for prerequisite requirements, and available personnel to prepare and operate HACCP plan. Also we suggest to revise and minimize current critical control points (CCPs). Time-temperature control of cold-storage rooms for carcasses and final products could be performed by control points of prerequisite requirements. As the occurrence frequency getting lower, metal detector should be replaced by intensified training of sanitary handling and safety procedure. This will be more effective and preventive measures against physical contaminants including metal particles. In conclusion, control point of prerequisite requirement may replace CCP in the plant with simple processing line and no heating process such as meat packaging industry.

Development of Decision Model and Management System to minimize Pavement Utility Cut for Road Facility (도로시설 재굴착 방지를 위한 의사결정모델 및 관리시스템 개발)

  • Cho, Jin-Young;Jang, Oun-Sung;Lee, Min-Jae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.4
    • /
    • pp.164-171
    • /
    • 2013
  • In urban planning, road facility is used not only for the transportation purpose but also for the utility line space purpose such as electrical, gas, tele communication, heating, water, sewer, and so on. However, since these utilities are built by many different groups, it becomes very difficult to communicate each other. Delay in one party can cause another party's schedule delay but they don't commuicate often. Also, some delay in utility work can cause frequent pavement cut. And, this will impact on construction cost, schedule delay, low quality, user complain and cost. This study developed spatiotemporal decision model to prevent prequent utility cut for mega project such as new urban development project. In addition, this study developed utility cut management system to manage utility cut schedule under pavement. Finally, developed system was applied to new urban development project and verified there effectiveness.

14 Planck Galactic Cold Clumps in the λ Orionis Complex: No dense cores detected with SCUBA-2

  • Yi, Hee-Weon;Lee, Jeong-Eun;Liu, Tie;Kim, Kee-Tae;Wu, Yuefang
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.73.1-73.1
    • /
    • 2016
  • We present preliminary results of the submillimeter continuum observations of 14 Planck Galactic Cold Clumps (PGCCs), located in the ${\lambda}$ Orionis Complex. This region is the nearest large HII region, which is an ideal site for a study of the stellar feedback to its surroundings. We observed 14 PGCCs with JCMT/SCUBA-2 and used J=1-0 transitions of CO isotopologues from the PMO mapping observation. Several sub-clumps toward three PGCCs were detected at $850{\mu}m$. In order to examine whether these clumps can be candidates for pre-stellar cores, we compared each clump mass calculated from the $850{\mu}m$ continuum map to its Virial mass and Jeans mass calculated from the $^{12}CO$ and $C^{18}O$ (1-0) spectra, respectively. All clumps have masses smaller than their Virial and Jeans masses, indicating that none of them are gravitational bound and thus in the pre-stellar core stage. Also, the CO depletion factor, which has been derived from the dust continuum and the $C^{18}O$(1-0) line and can be an indicator of core evolution, toward the clumps is in the range of 1 to 5, suggesting that they are not very evolved dense pre-stellar cores. In addition, within individual PGCCs, we found clear gradients of velocity (${\sim}1km\;s^{-1}\;pc^{-1}$) and temperature (${\sim}10K\;pc^{-1}$) in the $^{13}CO$ (1-0) first moment map and the $^{12}CO$(1-0) excitation temperature map, respectively. This can be attributed to the compression and external heating by the HII region, which may prevent clumps from forming gravitationally bound structures and eventually disperse clumps. These results could be a hint about the negative effect of stellar feedback on core formation.

  • PDF

A Study on the Thermal Elasto-Plastic Analysis of Plated Structures (판구조물의 열탄소성 해석)

  • Kim, B.I.;Jang, C.D.
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.34 no.1
    • /
    • pp.68-76
    • /
    • 1997
  • The welding-induced initial imperfections such as residual stresses and initial strains in plated structures of ships and offshore structures can be effectively evaluated by the thermal elasto-plastic analysis method proposed in this paper. In the analysis of heat conduction of plate structures, both the analytical method and the numerical method are used. For the thermal elasto-plastic analysis of plates, the finite element analysis is performed, based on the initial strain method. In the plastic domain during incremental process, the 2nd order terms of stress increments and yield stress increments were considered, so that time increment could be controlled for more stable solution. To measure temperature distribution and angular distortion of plates during welding, bead-on-plate experiment are perform with various heat input and plate thickness. Measured data show good agreement with the calculated results.

  • PDF

Defect Diagnosis of Cable Insulating Materials by Partial Discharge Statistical Analysis

  • Shin, Jong-Yeol;Park, Hee-Doo;Lee, Jong-Yong;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.1
    • /
    • pp.42-47
    • /
    • 2010
  • Polymer insulating materials such as cross linked polyethylene (XLPE) are employed in electric cables used for extra high voltage. These materials can degrade due to chemical, mechanical and electric stress, possibly caused by voids, the presence of extrinsic materials and protrusions. Therefore, this study measured discharge patterns, discharge phase angle, quantity and occurrence frequency as well as changes in XLPE under different temperatures and applied voltages. To quantitatively analyze the irregular partial discharge patterns measured, the discharge patterns were examined using a statistical program. A three layer sample was fabricated, wherein the upper and lower layers were composed of non-void XLPE, while the middle layer was composed of an air void and copper particles. After heating to room temperature and $50^{\circ}C$ and $80^{\circ}C$ in silicone oil, partial discharge characteristics were studied by increasing the voltage from the inception voltage to the breakdown voltage. Partial discharge statistical analysis showed that when the K-means clustering was carried out at 9 kV to determine the void discharge characteristics, the amount discharged at low temperatures was small but when the temperature was increased to $80^{\circ}C$, the discharge amount increased to be 5.7 times more than that at room temperature because electric charge injection became easier. An analysis of the kurtosis and the skewness confirmed that positive and negative polarity had counterclockwise and clockwise clustering distribution, respectively. When 5 kV was applied to copper particles, the K-means was conducted as the temperature changed from $50^{\circ}C$ to $80^{\circ}C$. The amount of charge at a positive polarity increased 20.3% and the amount of charge at a negative polarity increased 54.9%. The clustering distribution of a positive polarity and negative polarity showed a straight line in the kurtosis and skewness analyses.

A Study on the Self-Healing Mechanism using Spanning Tree Algorithm for PLC-based Home Network (전력선 홈 네트워크를 위한 스패닝 트리 알고리즘 기반의 자동 중계 기술 연구)

  • Hwang, Min-Tae;Choi, Sung-Soo;Lee, Won-Tae
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.7
    • /
    • pp.986-996
    • /
    • 2008
  • The home network environment based on the power line communication has some unexpected events. The noise source from the home appliances makes the network impedance increased, and the transmission packets distorted. Therefore the packet transmission from the source node may not be delivered to the destination node directly. In this paper we propose a new self-healing mechanism which relays the packet to the directly unreachable destination automatically with the help of intermediate nodes. In order to choose the minimum required intermediate nodes our mechanism makes a spanning tree with both the directly reachable nodes and indirectly reachable nodes via the intermedia nodes. We developed the network simulator in order to compare its performance to the Echelon's repeater selecting mechanism. Though it required more packet relations than Echelon's but the reachable probability to the destination was highly increased about two times.

  • PDF

Developments of performance-based evaluation criteria of utility tunnel (성능중심의 공동구 평가 기준 개발)

  • Byun, Yo-Seph;Seong, Joo-Hyun;Cho, Gey-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.715-724
    • /
    • 2022
  • With the enforcement of the infrastructure management act, the importance of utility tunnels that jointly accommodate life-lines such as electricity, communication, water supply, and heating facilities has increased. The currently applied utility tunnel maintenance system is managed in an accident-preventive safety-based evaluation method. However, this evaluation method has limitations in effective maintenance. In this study, performance evaluation items were derived through the Delphi method to suggest a criterion for quantitatively evaluating the performance of utility tunnels, and the weights for each item were calculated through the Analytic Hierarchy Process (AHP) method. In the future, it is judged that a more reasonable performance evaluation standard of utility tunnel can be prepared if modifications and supplements are made through field application.

Basic Performance Test of a Three Phase AC Arc Plasma Torch System for Plasma Gas Reforming (플라즈마 가스 개질 응용을 위한 3상 아크 플라즈마 토치 시스템 특성 실험)

  • DONG-HYUN LEE;DARIAN FIGUERA-MICHAL;HAE-WON PARK;NAM-KI LEE;SANG-YUN PAEK;SHIYOUNG YANG;JUN-HO SEO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.1
    • /
    • pp.8-16
    • /
    • 2023
  • In this work, we report basic performance test results of a lab-scale three phase alternative current (AC) arc plasma torch system for plasma gas reforming applications. The suggested system primarily consists of three graphite electrodes inclined at 12.5° to the central axis, a 𝞥 150 mm cylindrical gas path and a three phase-60 Hz AC power supply. At air flow rate of 50 Lpm and arc currents of 100-175 A, test results revealed that plasma resistances were decreasing from 1.08 Ω to 0.53 Ω with the increase of plasma power from 9.3 kW to 13.8 kW, causing the decrease of power factor and increase of the line voltages. However, the injected air can be heated quickly up to the temperatures of >1,200℃ when injecting AC arc plasma powers of >10 kW.

A Development of Automation System and a Way to use Solar Energy System Efficiently in Greenhouse(1) - Study on temperature variation of soil heating in greenhouse - (시설원예용 태양열 시스템의 효율적 이용과 자동화 장치개발(1) - 시설재배시 지중가온의 온도변화 연구 -)

  • 김진현;김철수;명병수;최중섭;구건효;김태욱
    • Journal of Bio-Environment Control
    • /
    • v.7 no.1
    • /
    • pp.15-24
    • /
    • 1998
  • The greenhouse temperature controls in general have been managed by the above-ground part environment, But the temperature of root zone was known very important factor for the 9rofth and the yield of vegetables in greenhouse. The purpose of this study is to develop a good method for cultivation using solar energy which can apply warming soil and to develop the greenhouse soil temperature automatic control system. Followings are summary of this study:1 When the greenhouse inner temperature changes were about 24$^{\circ}C$ during a day in October, the temperature of non-warmed soil was differenced 6$^{\circ}C$ in the depth 10cm and 3$^{\circ}C$ in the depth 20cm. 2. When water supply temperature was kept at 40, 50 and 6$0^{\circ}C$, the lowest soil temperature in the depth of 10cm is 2$0^{\circ}C$ and that of 20cm was 23$^{\circ}C$. and when the water supply temperature was over 4$0^{\circ}C$, the space heating temperature did not affect the temperature variation of soil. 3. In comparison with conditions of the warmed and non-warmed soil, when the water supply temperature is 28$^{\circ}C$, soil temperatures had the high temperature of 4$0^{\circ}C$~7$^{\circ}C$ in the depth of 10cm to 20 cm. 4. The line of boundary area was appeared in the depth of 15~20cm, 13~19cm and 12~17cm. when the water supply temperature was 4$0^{\circ}C$, 5$0^{\circ}C$ and 6$0^{\circ}C$. 5. When th inner greenhouse air temperature is maintained over 11$^{\circ}C$ and the water supply temperature is supported 28$^{\circ}C$, the lowest temperature is kept up over 2$0^{\circ}C$.

  • PDF