• 제목/요약/키워드: line tracking

검색결과 656건 처리시간 0.032초

광유도식 AGV를 위한 제어시스템 실현 (Implementation of Control System for Optically Guided AGV)

  • 양직현;이제희;김진환;허욱열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.95-97
    • /
    • 1997
  • This paper deals with design and implementation of the controller for optically guided AGV. When AGV has only three photo sensors in front of body, AGV doesn't know how much the entry angle to guide line is. In this case, it is difficult to compensate the tracking error. To make sure that the AGV does not secede the guide line in tracking, PI controller and fuzzy logic controller is proposed. The proposed controller was verified and experienced through real AGV system.

  • PDF

RFID기반의 Reference Tag를 이용한 쇼핑 고객 위치추적 및 동선분석에 관한 연구 (A Study for Shopping Customer's Location Tracking and Moving Line Analysis Using Reference Tag on based RFID)

  • 임상민;이근왕
    • 한국산학기술학회논문지
    • /
    • 제10권1호
    • /
    • pp.151-157
    • /
    • 2009
  • 본 연구에서는 오프라인 쇼핑몰에서 실시간 위치추적 기술과 USB 메모리와 RF가 융합된 Tag(이하 u-Card라 함)를 이용하여 위치추적 및 동선분석의 한계점을 개선하고 레퍼런스 태그를 이용한 위치추적을 통해 정확하고 신뢰성을 향상시키며 차폐물 간섭에 의한 오차율에 대한 한계점을 개선한 알고리즘 및 위치추적엔진 모듈을 제안한다.

퍼지논리와 유전알고리즘을 이용한 차륜형 이동로봇의 제어기 설계 (A Design of Tracking Controller of Wheeled Mobile Robot using Fuzzy Logic and Genetic Algorithm)

  • 김대준;최영규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2837-2839
    • /
    • 2000
  • We design a stable controller for a mobile robot with variable gains and reference velocity in order to apply the proper gains and reference velocity, which are generated with fuzzy logic in on-line. The stability is guranteed by the Lyapunov theory. The fuzzy logic rules is found in off-line with GA strategy which drives each object function to be the least. The proposed controller is applied smooth path tracking due to the local path planing. Simulation results show robust performances under a different initial conditions.

  • PDF

인공지능에 의한 부하전류파형의 인식으로 화재감지 시스템 (Fire detection system by awareness of load current waveform by Neural Network)

  • 이오걸;송호신;김태우;김민회
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.301-304
    • /
    • 2001
  • In this paper, a method which can detect tracking caused by the insulation deterioration of conduct wiring, is proposed. The computer which take experiment data is learned by neural network algorithm, which has recently been used for the load recognition. The proposed method in our study can be applied to the development of several measuring equipments such as hot-line insulation tester, car earth tester for the detection of tracking under hot-line state.

  • PDF

Robust Adaptive Sliding Mode Control of Robot Manipulators Using a Model Reference Approach

  • Lee, Tae-Hwan;Bae, Jun-Kyung
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권1호
    • /
    • pp.36-44
    • /
    • 1998
  • In this paper, a robust adaptive sliding mode control algorithm for accurate trajectory tracking of robot manipulators is proposed, with unknown parameters being estimated on-line. The controller is designed based on a Lyapunov method, which consists of adaptive feed-forward compensation part and a discontinuous control part. It is shown that, in the presence of the uncertainty and the disturbances arising from the actuator or some other causes, the tracking errors is bound to converge to zero asymptotically. An illustrative example is given to demonstrate the results of the propose method.

  • PDF

MAXIMUM POWER POINT TRACKING CONTROL OF PHOTOVOLTAIC ARRAY USING FUZZY NEURAL NETWORK

  • Tomonobu Senjyu;Yasuyuki Arashiro;Katsumi Uezato;Hee, Han-Kyung
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.987-992
    • /
    • 1998
  • Solar cell has an optimum operating point to extract maximum power. To control operating point of the solar cell, a fuzzy controller has already been proposed by our research group. However, several parameters are determined by trial and error. To overcome this problem, this paper adopts Fuzzy Neural Network (FNN) for maximum power point tracking control for photovoltaic array. The FNN can be trained to perfect fuzzy rules and to find an optimum membership functions on-line.

  • PDF

The Four Points Diagonal Positioning Algorithm for Iris Position Tracking Improvement

  • Chai Duck-Hyun;Ryu Kwang-Ryol
    • Journal of information and communication convergence engineering
    • /
    • 제2권3호
    • /
    • pp.202-204
    • /
    • 2004
  • An improvement of tracking capacity to find a position of the Iris images is presented in this paper. The propose algorithm is used the Four Points Diagonal Positioning algorithm that the image is positioned with arbitrary 4 points on the edge of iris and the selective 4 points are drawn by a diagonal line on the cross. The experiment result shows that the algorithm is efficient to track on the eyelid.

A Study on the Enhancement of Tracking Capability for Iris Image

  • Chai, Duck-Hyun;Kim, Jung-Tae;Hur, Chang-Wu;Ryu, Kwang-Ryol
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2004년도 SMICS 2004 International Symposium on Maritime and Communication Sciences
    • /
    • pp.24-27
    • /
    • 2004
  • An enhancement of tracking capacity to find a position of the Iris images is presented in this paper. The propose algorithm is called FFDP (Four Points Diagonal Positioning) that the image is positioned with arbitrary 4 points on the edge of iris and the selective 4 points are drawn by a diagonal line on the cross. The experiment result shows that the algorithm is efficient to track on the eyelid.

  • PDF

수력 발전기 권선에서의 운전중 부분방전 측정기법 (On-line partial discharge measurement techniques of hydro-generator windings)

  • 황동하;김진봉;김용주;박명수;김택수
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.294-300
    • /
    • 1996
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the endwinding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current and .DELTA.tan.delta. tests has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot dischages may not be found with off-line diagnoses. This paper introduces the on-line partial discharge measurement techniques using frequency spectrum analyzer(FSA) for the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF