• Title/Summary/Keyword: line to line short

Search Result 1,143, Processing Time 0.031 seconds

Artificial line for short-line fault test (근거리선로고장전류 차단시험용 Artificial line)

  • Park, Seung-Jae;Rhyou, Hyeong-Kee;Kang, Young-Sik;Koh, Heui-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1783-1785
    • /
    • 2001
  • With the 4-MJ synthetic testing facilities completed, KERI can perform the circuit breaker testing up to 420 kV, 50 kA ratings. The short-line fault test is one of the necessary test items which are required for the circuit breaker, and in order to perform the short-line fault test KERI(Korea Electrotechnology Institute) has used the "new artificial line" which has small dimension and is easy to generate the saw-tooth wave. This paper describes the following items of the new artificial line. -Description of 4-kinds of artificial lines and determination of the circuit parameter of artificial line. -TRV characteristics of saw-tooth waves for each circuit. -KERI's artificial line.

  • PDF

Suggestion of the morphological characteristic parameters according to the Lee's physical constitution theory using X-ray computed tomography (X선 CT화상을 이용한 사상체질의 형태학적 특징 파라메타의 제안)

  • Jo, Bong-Kwan;Bae, Jong-Il;Ko, Byung-Hee;Saito, Masao
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.11
    • /
    • pp.13-16
    • /
    • 1993
  • In this paper the morphological characteristic parameters according to the Lee's physical constitution theory are suggested using the X-ray computed tomography. The Lee's physical constitution theory is classify into 4 physical constitutional types by the relative degree of visceral function: those are macro-negative(strong liver- weak lung), micro-negative(strong kidney- weak spleen), micro-positive(strong spleen- weak kidney) and macro-positive(string lung- weak liver). The morphological characteristic parameters are the following. The AA-line is the distance between Rt. & Lt. acupuncture point keug-cheun. The BB-line is the length of lung. The CC-line is the longest width of thorax. The DD-line is the vertical distance between the CC-line and the EE-line. The EE-line is the distance between the Rt. and Lt. anterior superior iliac spines. As the results macro-negative(strong liver-weak lung) has the longest CC-line and the short BB-line. Micro-negative(strong kidney-weak spleen) has the longest EE-line and the short CC-line. Micro-positive(strong spleen-weak kidney) has the longest DD-line and the short BB-line. And macro-positive(strong lung-weak kidney) has the longest BB-line and the short EE-line.

  • PDF

Development of Short-Wavelength Transmission Line Employing Periodically Perforated Ground Metal for Application to Miniaturized On-chip Passive Components on Si RFIC (Si RFIC상의 온칩 수동소자에의 응용을 위한 주기적 접지 금속막 선로를 이용한 단파장 전송선로 개발)

  • Joh, Han-Nah;Park, Young-Bae;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.330-335
    • /
    • 2008
  • In this study, highly miniaturized short-wavelength transmission line employing periodically perforated ground metal (PPGM) structures were developed for application to miniaturized on-chip passive component on Si RFIC. The transmission line employing PPGM structure showed shorter wavelength and lower characteristic impedance than conventional coplanar-type transmission line. The wavelength of the transmission line employing PPGM structure was 57% of the conventional coplanar-type transmission line on Si Radio Frequency Integrated Circuit (RFIC) substrate. Basic characteristics of the transmission line employing PPGM structure were also investigated in order to evaluate its suitability for application to a development of miniaturized passive on-chip components. According to the results, it was found that the PPGM structure is a promising candidate for application to a development of miniaturized on-chip passive components on Si RFIC.

A Study on Advanced Fault Locating for Short Fault of a Double Circuit Transmission Line (병행 2회선 송전선로의 선간단락시 고장점 표정의 개선에 관한 연구)

  • Park, Yu-Yeong;Park, Chul-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.28-37
    • /
    • 2016
  • Fault locating is an important element to minimize the damage of power system. The computation error of fault locator may occur by the influence of the DC offset component during phasor extraction. In order to minimize the bad effects of DC offset component, this paper presents an improved fault location algorithm based on a DC offset removal filter for short fault in a double circuit transmission line. We have modeled a 154kV double circuit transmission line by the ATP software to demonstrate the effectiveness of the proposed fault locating algorithm. The line to line short faults were simulated and then collected simulation data was used. It can be seen that the error rate of fault locating estimation by the proposed algorithm decreases than the error rate of fault locating estimation by conventional algorithm.

The Study of Comparison of the Symmetrical Short Circuit Test Current with ANSI/IE Transformers. (변압기의 단락강도 시험 시 ANSI와 IEC 규격에 의한 시험 전류의 비교 연구)

  • Kim, Sun-Koo;Kim, Won-Man;La, Dae-Ryeol;Roh, Chang-Il;Lee, Dong-Jun;Jeong, Heung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.694-696
    • /
    • 2002
  • Transformers together with all equipment and accessories shall be designed and constructed to withstand the mechanical and thermal stresses produced by external short circuit which include three phase, single line-to-ground, double line-to-ground and line-to-line faults etc. Generally the Short Circuit Test of transformers is tested according to the ANSI/IEEE, IEC/JEC, KS etc, in domestic. In this study, it will be showed and compared the difference of symmetrical current for short circuit test of a Pad -mounted transformer according to with ANSI /IEEE and IEC.

  • PDF

The Study of Characteristics evaluation of short-circuit tests for Power Transformers (변압기 단락강도시험 성능평가에 관한 고찰)

  • Roh, Chang-Il;Kim, Sun-Koo;Jung, Heung-Soo;Kim, Won-Man;Lee, Dong-Jun;Kim, Sun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.913-914
    • /
    • 2007
  • Power transformer shall be designed and constructed to withstand the mechanical and thermal stresses produced by external short circuits which include three-phase, single line to ground, double line-to-ground, and line-to-line faults on any one set terminals at a time. This paper presents the method of short-circuit test and means of evaluation during and after each test to judge the results of short-circuit tests.

  • PDF

Travel Behavior Analysis for Short-term Railroad Passenger Demand Forecasting in KTX (KTX 단기수요 예측을 위한 통행행태 분석)

  • Kim, Han-Soo;Yun, Dong-Hee
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1282-1289
    • /
    • 2011
  • The rail passenger demand for the railroad operations required a short-term demand rather than a long-term demand. The rail passenger demand can be classified according to the purpose. First, the rail passenger demand will be use to the restructure of line planning on the current operating line. Second, the rail passenger demand will be use to the line planning on the new line and purchasing the train vehicles. The objective of study is to analyze the travel behavior of rail passenger for modeling of short-term demand forecasting. The scope of research is the passenger of KTX. The travel behavior was analyzed the daily trips, origin/destination trips for KTX passenger using the ANOVA and the clustering analysis. The results of analysis provide the directions of the short-term demand forecasting model.

  • PDF

A LOSSY LINE DISTRIBUTED PARAMETERS CALCULATION USING DATA OF OPEN-SHORT IMPEDANCE MEASURING METHOD (Open-Short 방식의 임피던스 측정에 의한 분포정수의 보정)

  • ANANIEV, Igor P.;Joe, Ki-Yeon;Byun, Young-Bok;Seo, Jeong-Il;Kim, Eun-Soo;Kim, Tae-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2553-2555
    • /
    • 1999
  • The paper contains design formulas and an execution algorithm for calculation of distributed parameters as well as wave and impedance parameters of a uniform transmission line using data of the line input impedance measurements by the OPEN-SHORT method. In difference from published before works on the OPEN-SHORT method application for line parameters determination, in which the lines with small losses are considered /1-3/, the obtained formulas allow to calculate parameters of transmission lines with arbitrary losses. It opens new possibilities of the OPEN-SHORT method utilization for development and application of the probe - type lossy dielectric media parameters meters based on transmission lines, including probe-type moisture material meters.

  • PDF

An innovative geometry control method for short-line match precast segmental bridges

  • Xuzheng Liu;Huibing Xu;Jianyang Yu;Wei Quan
    • Advances in concrete construction
    • /
    • v.16 no.2
    • /
    • pp.79-89
    • /
    • 2023
  • The occurrence of unexpected horizontal offset in the instrument or target will result in accumulated horizontal deviation in segment alignment with traditional short-line match method. A geometry control method, the four-point method, is developed for precast segmental bridges to avoid the influences of unexpected horizontal offset. The concept of the four-point method is elucidated. Furthermore, the detailed instruments and instructions are introduced. Finally, the four-point method is validated through a practical engineering application. According to the survey data, after short-line match precast construction, the vertical deviations on both sides vary between -5 mm and 5 mm in almost all segments, and the horizontal deviations vary between -4 mm and 4 mm in all segments. Without on-site adjustment, the maximum vertical and horizontal closure gaps are 12.3 and 26.1 mm, respectively. The four-point method is suggested to alleviate the issues associated with relatively poor soil conditions in casting yard.

The Design of Lumped Constant Circuit for the Simulation of A Real 22.9 kV-y Distribution Line (22.9 kV-y 실긍장 배전선로 모의를 위한 집중정수회로의 설계)

  • Yun, Chul-Ho;Jeong, Yeong-Ho;Han, Yong-Huei
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1186-1188
    • /
    • 1999
  • When we perform the test related to the power distribution system such as artificial fault test, protective coordination test, distribution automation test in short length test line, Lumped Constant Circuit, a kind of variable impedance, should be attached to the test line in order to make it equivalent to a real line in length electrically. In this paper we designed the positive sequence and zero sequence Lumped Constant Circuit with optimized inductor and resister for the modification of long, 16km, distribution line, when they are attached to the short, 4km, distribution test line.

  • PDF