• Title/Summary/Keyword: line sources

Search Result 621, Processing Time 0.029 seconds

Source Characteristics of Odorous Compounds in the Ban Wal Industrial Complex and a Preliminary Study of Industry- specific Odor Indices (반월공단내 주요 산업시설물들의 대기배출시설을 중심으로 한 주요 악취성분의 배출특성 및 배출원별 악취인자 선별 방식에 대한 예비연구)

  • Kim K.-H.;Choi YJ;Hong YJ;Sa JH;Park JH;Jeon EC;Choi CR;Koo YS
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.215-226
    • /
    • 2005
  • In this study, we investigated the emission concentrations of 31 odorous compounds from various emission sources of 37 individual companies located within the Ban Wal industrial complex of Ansan city, Korea. In the course of our study, we attempted to evaluate emission characteristics of different industrial activities and relative significance of different odorous components . Based on our measurements of odorous compounds, we were able to find a line of evidence to draw a conclusion that a number of odorous compounds can be used as indices to specifically point out the influence of certain industrial activities. It was found that hydrogen sulfide and trimethyl amine record the highest contribution from leather industry. Likewise, acetaldehyde showed its maximum contribution from food-beverage sector, while ammonia for paper-mill, pulp production sector. On the other hand, the results of styrene and most YOC including BTEX were not useful, as their concentrations were not significantly high enough to judge from such respect.

Does High-Speed Rail Have Superiority over Motorway in Terms of CO2 Emission? (고속철도는 고속도로에 비하여 저탄소 친환경적인가?)

  • Kang, Taeseok;Chang, Hyunho
    • International Journal of Highway Engineering
    • /
    • v.18 no.5
    • /
    • pp.83-93
    • /
    • 2016
  • PURPOSES : The aim of this article is to compare and identify eco-friendly competitiveness between (regional) motorway and high-speed rail(HSR) from the perspective of $CO_2$ emission in the Republic of Korea. METHODS : In order for an analysis of low-carbon competitiveness between the two modes, $CO_2e$ emission, $CO_2eppk$ (equivalent $CO_2$ gram per passenger kilometer), is employed as a comparison index. As for HSR, the index is calculated based on the passenger transport data and the gross of $CO_2e$ produced by Kyungbu high-speed line in 2013. Additionally, the gross of $CO_2e$ is computed by the greenhouse gas emission factors of domestic electricity generation mix. Regarding the index of motorway, it is directly calculated using both the official $CO_2e$ emission factor and the passenger-car occupancy of motorway. RESULTS : The results revealed, in the case of inter-regional transport, that the $CO_2e$ emission of displacement-based cars is 54.9% less than that of HSR, as the domestic electric power systems heavily relies on the thermal power plants over 66%. Note that internal combustion engines commonly used for vehicles are more energy-efficient than steam-driven turbines usually utilized for thermal power generation. CONCLUSIONS : It can be seen, at the very least in our study, that HSR has no superiority over motorway in the case of $CO_2e$ emission under the situations of domestic electricity generation mix. In addition, advanced eco-friendly vehicles have strong advantages over HSR. Therefore, all-out efforts should be made to develop and harvest renewable energy sources in order to achieve low-carbon HSR, sparing fossil fuels.

Application of SFCL on Bus Tie for Parallel Operation of Power Main Transformers in a Fuel Cell Power Systems

  • Chai, Hui-Seok;Kang, Byoung-Wook;Kim, Jin-Seok;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2256-2261
    • /
    • 2015
  • In the power plant using high temperature fuel cells such as Molten Carbonate Fuel Cell(MCFC), and Solid Oxide Fuel Cell(SOFC), the generated electric power per area of power generation facilities is much higher than any other renewable energy sources. - High temperature fuel cell systems are capable of operating at MW rated power output. - It also has a feature that is short for length of the line for connecting the interior of the generation facilities. In normal condition, these points are advantages for voltage drops or power losses. However, in abnormal condition such as fault occurrence in electrical system, the fault currents are increased, because of the small impedance of the short length of power cable. Commonly, to minimize the thermal-mechanical stresses on the stack and increase the systems reliability, we divided the power plant configuration to several banks for parallel operation. However, when a fault occurs in the parallel operation system of power main transformer, the fault currents might exceed the interruption capacity of protective devices. In fact, although the internal voltage level of the fuel cell power plant is the voltage level of distribution systems, we should install the circuit breakers for transmission systems due to fault current. To resolve these problems, the SFCL has been studied as one of the noticeable devices. Therefore, we analyzed the effect of application of the SFCL on bus tie in a fuel cell power plants system using PSCAD/EMTDC.

Improving International Access to the IARC Monographs Database with Linkage to other Sources of Information

  • Rice, Jerry M.;Waters, Michael D.;Wright, R.Glenn
    • Toxicological Research
    • /
    • v.17
    • /
    • pp.227-236
    • /
    • 2001
  • The IARC Monographs Programme on the Evaluation of Carcinogenic Risks to Humans has reviewed, summarized and evaluated 869 environmental agents and exposures as oj June 2000. This large collection includes all relevant published epidemiological data on cancer in exposed humans and results of bioassays for carcinogenicity in experimental animals. Since 1986. cancer data have been systematically supplemented by summaries of other toxicological data that are relevant to assessments of carcinogenic hazard. These include summaries qf genetic and related effects of chemicals. which have been prepared as Genetic Activity Profiles (GAP) by the U.S. EPA in collaboration with IARC. As the Mono-graphs have proved increasingly valuable and influential worldwide. they have evolved into an encyclopedia on environmental carcinogenic risks to humans. However. the Monographs have historically been prepared only as printed books with limited distribution. and the Monographs Programme has needed to adjust to expectations oj wider availability. Since 1998 the evaluations and summaries have been globally accessible by Internet from IARC (http://www.iarc.fr) and the GAP profiles by Internet from EPA (http://www.epa.gov/gapdb/). with the two web sites linked. Improved EPN/ARC GAP database and software. GAP2000. now link GAP profiles directly to the appropriate IARC web pages for summaries of evaluations of a given compound and its overall IARC classification. During the year 2000. by means of optical character recognition (OCR) technology the entire series of IARC Monographs is being converted to an electronic version. The first edition is now available commercially in CD-ROM format and will soon become available on-line at .

  • PDF

Cost savings for paper machines with automation solution packages (초지기 자동화 해법에 의한 운전비용 절감대책)

  • Sorsa, Jukka
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2007.05a
    • /
    • pp.83-125
    • /
    • 2007
  • Increasing energy costs have caused profitability problems for paper suppliers. Therefore unprofitable lines are being closed down. The actions aiming for improved profits are focused either on cost savings or on increasing the capacity of the remaining machines. The runnability of a paper machine and its total efficiency have a significant effect on energy consumption. Producing one ton of waste paper consumes at least as much energy as producing the same amount of sellable end product. New automation solutions enable significant cost-effective improvements to the total efficiency of a line without large investment projects. The measures focus on minimizing changes, interruptions, interruption recovery times and grade change times. Newest actuators, online quality measurements and wet end analysators create an improvement potential, which can be optimally implemented with the latest machine direction control solutions, based on model predictive control concepts. Equally, drying management is significant to the energy consumption. The newest control strategies optimize the use of various drying actuators for different situations; either by responding to changes as efficiently as possible or by using only the cheapest energy sources in stable situations. An even steam supply, which is vital for paper machines, is achieved with control for the power plant steam network. This makes possible to avoid the delays upon starting the paper machine and assure an even steam supply for the drying section and the actuators. This document describes means which have brought significant energy and raw material savings for paper machines. Metso Automation has provided efficiency improvement packages, which are usually based on optimized control of dry weight and drying in all running conditions. The solutions are based on performance analysis, on which the estimations for improvement potential and the necessary actions are based on. Typically benefits on an annual level have been from hundreds of thousands of euros to over one million euro. For example, variations in dry weight have been decreased more than 50%. The results are presented with a few examples. Additionally, the analysis models, adjustment solutions and the changes in running methods with which the results were achieved, are presented.

  • PDF

Palm-Size-Integrated Microwave Power Module at 1.35-GHz for an Atmospheric Pressure Plasma for biomedical applications

  • Myung, C.W.;Kwon, H.C.;Kim, H.Y.;Won, I.H.;Kang, S.K.;Lee, J.K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.498-498
    • /
    • 2013
  • Atmospheric Pressure Plasmas have pioneered a new field of plasma for biomedical application bridging plasma physics and biology. Biological and medical applications of plasmas have attracted considerable attention due to promising applications in medicine such as electro-surgery, dentistry, skin care and sterilization of heat-sensitive medical instruments [1]. Traditional approaches using electronic devices have limits in heating, high voltage shock, and high current shock for patients. It is a great demand for plasma medical industrial acceptance that the plasma generation device should be compact, inexpensive, and safe for patients. Microwave-excited micro-plasma has the highest feasibility compared with other types of plasma sources since it has the advantages of low power, low voltage, safety from high-voltage shock, electromagnetic compatibility, and long lifetime due to the low energy of striking ions [2]. Recent experiment [2] shows three-log reduction within 180-s treatment of S. mutans with a low-power palm-size microwave power module for biomedical application. Experiments using microwave plasma are discussed. This low-power palm-size microwave power module board includes a power amplifier (PA) chip, a phase locked loop (PLL) chip, and an impedance matching network. As it has been a success, more compact-size module is needed for the portability of microwave devices and for the various medical applications of microwave plasma source. For the plasma generator, a 1.35-GHz coaxial transmission line resonator (CTLR) [3] is used. The way of reducing the size and enhancing the performances of the module is examined.

  • PDF

The Relationships between Health Behaviors, Mental Health and Smoking among Korean Adolescents (한국 청소년의 건강행태 및 정신건강과 흡연의 관련성)

  • Song, Hye-Young;Doo, Eun Young;Choi, Sujin
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.7
    • /
    • pp.557-570
    • /
    • 2017
  • This study, as a secondary analysis research, bases its source upon on raw data from the on-line survey of the Korean adolescents' health behaviors in 2015. This study was conducted to clarify the relevance of Korean adolescents' smoking with their health behaviors and mental health, and thus further to provide basic sources of effective education for their smoking prevention and for program development. The results of the study showed that Korean adolescents' smoking was significantly affected by the adolescents' sex, grades, school achievements, types of schools, allowances, economic status, parents' educational background (p<0.001). Meanwhile, smoking based on the characteristics of health behaviors was significantly different according to alcohol consuming experience, families' and friends' smoking, physical activity and subjective health status, and BMI (p<0.001). Smoking characterized by mental health showed the significant difference in their stress recognition, subjective sleep patterns, depressed experiences, suicidal ideation, and subjective sense of happiness (p<0.001). Based on all the factors regarding youth smoking, there should be development and provision of educational program for smoking prevention and cessation, including healthy behavior and mental health improvement for Korean adolescent.

Methodology for the International Standardization of Hydrogen using FMEA (FMEA를 이용한 수소 국제표준 제정의 방법론)

  • Ku, Yeon-Jin;Kang, Byung-IK;Yim, Sang-Sik;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.7-12
    • /
    • 2018
  • Hydrogen energy has been attracting attention as an alternative energy source for petroleum and stoneware. In addition, the benefits of hydrogen energy, such as no dust, abundant energy source and no ecological impact, were to compare favorably with other renewable energy sources. However, unclear product development standards and usage of hydrogen energy increase the risk of accidents in hydrogen energy related product lines. And, the high energy level of hydrogen has implications for large social problems in the event of an accident. Therefore, this study suggests the standardization method of fast hydrogen energy to help secure the safe market of hydrogen energy related products, which are mostly developed new products.

Operating Characteristic Analysis of Optic Temperature Sensor for Overheat Detection in Panel Board (분전함에서 이상발열 감지를 위한 광온도센서의 동작특성 분석)

  • Moon, Hyun-Wook;Kim, Dong-Woo;Gil, Hyung-Jun;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.100-106
    • /
    • 2009
  • In this study, methods of overheat detection at the coupling or wire in electrical facility are investigated, operating characteristic about the optic temperature sensor for continuous on-line temperature monitoring in diagnostics system of electrical facility is analyzed. Heating sources in the experiment for operating characteristics of optic temperature sensor use black body and hot plate, output voltage of optic temperature sensor in accordance with temperature variation is analyzed. Overheat generation due to poor contact at the circuit breaker in panel board detects using a thermocouple, infrared thermal camera and optic temperature sensor, and experiment results are analyzed. The effect of optic temperature sensor is the same that of other methods. These results expect to use basic research material for adjusting field of electrical diagnostics system using RFID type optic temperature sensor in the near future.

Performance of membrane filtration in the removal of iron and manganese from Malaysia's groundwater

  • Kasim, Norherdawati;Mohammad, Abdul Wahab;Abdullah, Siti Rozaimah Sheikh
    • Membrane and Water Treatment
    • /
    • v.7 no.4
    • /
    • pp.277-296
    • /
    • 2016
  • The aim of this research was to investigate the ability of nanofiltration (NF) and ultrafiltration (UF) membranes as a filtration unit for groundwater treatment for drinking water resources. Commercial membranes denoted as TS40, TFC-SR3 and GHSP were used to study the performance based on rejections and fluxes. The investigation has been conducted using natural groundwater obtained from a deep tube well with initial concentration of iron (Fe) and manganese (Mn) at 7.15 mg/L and 0.87 mg/L, respectively. Experimental results showed that NF membranes exhibited higher fluxes than UF membrane with pure water permeability at 4.68, 3.99 and $3.15L.m^{-2}.h^{-1}.bar^{-1}$, respectively. For metal rejection, these membranes have performed higher removal on Fe with TS40, TFC-SR3 and GHSP membranes having more than 82%, 92% and 86% respectively. Whereas, removal on Mn only achieved up to 60%, 80% and 30%, for TS40, TFC-SR3 and GHSP membranes respectively. In order to achieve drinking water standard, the membranes were efficient in removing Fe ion at 1 and 2 bar in contrast with Mn ion at 4 and 5 bar. Higher rejection of Fe and Mn were achieved when pH of feed solution was increased to more than 7 as TFC-SR3 membrane was negatively charged in basic solution. This effect could be attributed to the electrostatic effect interaction between membrane material and rejected ions. In conclusion, this study proved that NF membrane especially the TFC-SR3 membrane successfully treated local groundwater sources for public drinking water supply in line with the WHO standard.