• Title/Summary/Keyword: line sampling

Search Result 374, Processing Time 0.033 seconds

목시조사에 의한 2002년 동해안 밍크고래의 분포와 풍도에 관한 연구

  • 손호선;김장근;박영철;정의철
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2002.10a
    • /
    • pp.263-263
    • /
    • 2002
  • 동해안에 서식하는 밍크고래의 분포와 풍도를 알기 위해서 거리표집법(Distance sampling)의 일종인 직선횡단선 조사법 (Line transect method)을 적용하여 5월 14일부터 6월 7일까지 25일간 동해일원에서 국립수산과학원 조사선 탐구 3호 (360 G/T)를 이용하여 조사를 하였다. 동해안을 연안과 외양으로 구분하여 7개의 소해역으로 나눈 뒤에, 각 소해역의 조사선 (Survey line)을 설정하였는데, 조사선의 시작점은 무작위로 선정하여 지그재그로 조사선을 결정하였다. (중략)

  • PDF

Preconcentration of Cd by Continuous Hydroxide Precipitation-Dissolution in Atomic Emission Spectrometry

  • 연평흠;허걸;박용남
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.7
    • /
    • pp.766-770
    • /
    • 1998
  • On-line preconcentration by direct precipitation with hydroxide has been developed and applied for the analysis of Cd in Inductively Coupled Plasma Atomic Emission Spectrometry. Cadmium is continuously precipitated with hydroxide and dissolved by nitric acid in on-line mode. Currently, the enrichment factor is more than 90 times for 20.0 mL of sample and could be further increased very easily. For a large sample throughput, 1.0 mL of sample loop is used and the enrichment factor is 4.5 with the sampling speed of 15/hr. The method has been applied to the analysis of NIST reference sample and has yielded good results with the certified value.

Reliability Improvement of Insulation Diagnosis Using the Hydro-Generator On-Line Partial Discharge Monitoring System (수력발전기 On-line 부분방전 측정 시스템을 이용한 절연상태 진단의 신뢰성 향상)

  • Ok, Yeon-Ho;Lee, Eun-Woong;Lim, Jae-Il;Park, Ji-Kun;Kwak, Won-Ku;Lee, Jae-Heung;Shin, Jae-Pil;Shin, Byoung-Chol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.469-475
    • /
    • 2009
  • Accident dangerousness of domestic hydro power generators which are operated in Korea is on the increase because of use at the long term. On this, the Off-line diagnosis techniques developed to the On-line by continued domestic technical development since 2000. Especially, On-line insulation diagnosis of domestic hydro power generator is possible by localization of partial electric discharge sensor and On-line insulation diagnosis system. This paper shows the diagnosis result that is applied localized Ceramic Coupler and PDMS-HG(Partial Discharge Monitoring System for Hydro Generator) at four Chung-ju hydro Generator used for 25 years. Particularly, the confidence of insulation diagnosis is improved by using high frequency filter and sampling the partial discharge signals which occur in site. For reviewing the confidence of On-Line insulation diagnosis system, we measured the outside noises and partial discharge signals during practical operation by using the partial discharge diagnosis system of the Full A/D process. And we reviewed the confidence of the On-Line insulation diagnosis system by comparing and analyzing these data.

FREQUENCY HISTOGRAM MODEL FOR LINE TRANSECT DATA WITH AND WITHOUT THE SHOULDER CONDITION

  • EIDOUS OMAR
    • Journal of the Korean Statistical Society
    • /
    • v.34 no.1
    • /
    • pp.49-60
    • /
    • 2005
  • In this paper we introduce a nonparametric method for estimating the probability density function of detection distances in line transect sampling. The estimator is obtained using a frequency histogram density estimation method. The asymptotic properties of the proposed estimator are derived and compared with those of the kernel estimator under the assumption that the data collected satisfy the shoulder condition. We found that the asymptotic mean square error (AMSE) of the two estimators have about the same convergence rate. The formula for the optimal histogram bin width is derived which minimizes AMSE. Moreover, the performances of the corresponding k-nearest-neighbor estimators are studied through simulation techniques. In the absence of our knowledge whether the shoulder condition is valid or not a new semi-parametric model is suggested to fit the line transect data. The performances of the proposed two estimators are studied and compared with some existing nonparametric and semiparametric estimators using simulation techniques. The results demonstrate the superiority of the new estimators in most cases considered.

Downward and Upward Air Flow Effects on Fume Particle Dispersion in Laser Line Cutting of Optical Plastic Films

  • Kim, Kyoungjin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.2
    • /
    • pp.37-44
    • /
    • 2020
  • In improving laser cutting of optical plastic films for mass production of optoelectronics display units, it is important to understand particle contamination over optical film surface due to fume particle generation and dispersion. This numerical study investigates the effects of downward and upward air flow motions on fume particle dispersion around laser cut line. The simulations employ random particle sampling of up to one million fume particles by probabilistic distributions of particle size, ejection velocity and angle, and fume particle dispersion and surface landing are predicted using Basset-Boussinesq-Oseen model of low Reynolds number flows. The numerical results show that downward air flow scatters fume particles of a certain size range farther away from laser cut line and aggravate surface contamination. However, upward air flow pushes fume particles of this size range back toward laser cut line or sucks them up with rising air motion, thus significantly alleviating surface contamination.

Induction Motor Drive Using a Line Commutated Inverter with a Forced-Commutated Circuit (장제전류회로를 갖는 타려식 인버터를 이용한 유도적 성질)

  • 정연택;심재명
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.6
    • /
    • pp.588-599
    • /
    • 1992
  • This paper describes the variable speed drive of an induction motor by the line commutated inverter, which is operated in the forced commutation mode from start-up to operating point of load commutation. A novel forced-commutation circuit is proposed in this paper. The selection range of leading condenser to decide load commutation starting point is simulated by the sampling data of a general purpose IM and a high speed IM. The experiment to drive IM by a line commutated inverter with the proposed forced commutated circuits is performed. There was no problem in driving IM from standstill to starting point of load commutation by a line commutated inverter with forced commutation.

Probabilistic Evaluation of Voltage Quality on Distribution System Containing Distributed Generation and Electric Vehicle Charging Load

  • CHEN, Wei;YAN, Hongqiang;PEI, Xiping
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1743-1753
    • /
    • 2017
  • Since there are multiple random variables in the probabilistic load flow (PLF) calculation of distribution system containing distributed generation (DG) and electric vehicle charging load (EVCL), a Monte Carlo method based on composite sampling method is put forward according to the existing simple random sampling Monte Carlo simulation method (SRS-MCSM) to perform probabilistic assessment analysis of voltage quality of distribution system containing DG and EVCL. This method considers not only the randomness of wind speed and light intensity as well as the uncertainty of basic load and EVCL, but also other stochastic disturbances, such as the failure rate of the transmission line. According to the different characteristics of random factors, different sampling methods are applied. Simulation results on IEEE9 bus system and IEEE34 bus system demonstrates the validity, accuracy, rapidity and practicability of the proposed method. In contrast to the SRS-MCSM, the proposed method is of higher computational efficiency and better simulation accuracy. The variation of nodal voltages for distribution system before and after connecting DG and EVCL is compared and analyzed, especially the voltage fluctuation of the grid-connected point of DG and EVCL.

Analysis and Design of a Separate Sampling Adaptive PID Algorithm for Digital DC-DC Converters

  • Chang, Changyuan;Zhao, Xin;Xu, Chunxue;Li, Yuanye;Wu, Cheng'en
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2212-2220
    • /
    • 2016
  • Based on the conventional PID algorithm and the adaptive PID (AD-PID) algorithm, a separate sampling adaptive PID (SSA-PID) algorithm is proposed to improve the transient response of digitally controlled DC-DC converters. The SSA-PID algorithm, which can be divided into an oversampled adaptive P (AD-P) control and an adaptive ID (AD-ID) control, adopts a higher sampling frequency for AD-P control and a conventional sampling frequency for AD-ID control. In addition, it can also adaptively adjust the PID parameters (i.e. $K_p$, $K_i$ and $K_d$) based on the system state. Simulation results show that the proposed algorithm has better line transient and load transient responses than the conventional PID and AD-PID algorithms. Compared with the conventional PID and AD-PID algorithms, the experimental results based on a FPGA indicate that the recovery time of the SSA-PID algorithm is reduced by 80% and 67% separately, and that overshoot is decreased by 33% and 12% for a 700mA load step. Moreover, the SSA-PID algorithm can achieve zero overshoot during startup.

Increase of Cell Concentration by the Automatic Analysis and Addition of glucose with an On-line Flow Injection Analysis System int he Cultivation of Saccharomyces cerevisiae Using a Korean Paper Digestion Wastewater (한지자숙폐액을 이용한 Saccharomyces cerevisiae의 배양에서 온-라인 FIA시스템에 의한 Glucose의 자동분석 및 첨가에 의한 증균)

  • 이형춘
    • KSBB Journal
    • /
    • v.15 no.4
    • /
    • pp.388-392
    • /
    • 2000
  • An on-line glucose flow injection analysis system was developed and used for the automatic analysis and addition of glucose in the cultivationof a Saccharomyces cerevisiae in a korean paper digestion wastewater in order to increase the cell concentration. The system was composed of a ceramic sampler a sampling valve an injection valve an immobilized glucose oxidase column a debbble a flow cell with platinum electrodes a potentiostat a computer and interface system and tubing pumps. The glucose concentration of the wastewater medium was mainitained at the low concentration of $176{\pm}31 mg/L$ with the on-line FIA system and by adding glucose and $>(NH_4)_2S0_4$ the cell concentration as total cell count can be increased by 3.1times.

  • PDF

Parametric Equation of Hough Transform for Log-Polar Image Representation (로그폴라 영상 표현을 위한 매개변수 방정식의 Hough 변환)

  • Choi, Il;Kim, Dong-su;Chien, Sung-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.4
    • /
    • pp.455-461
    • /
    • 2002
  • This paper presents a new parametric log line equation of polar form for Hough transform in log-polar plane, in which it can remove the well-known unboundedness problem of Hough parameters. Bolduc's method is used to generate a log-polar image dividing the fovea and periphery from a Cartesian image. Edges of the fovea and periphery are detected by using the Sobel mask and the proposed space-variant gradient mask, and are combined in the log-polar plane. The sampled points that might constitute a log line are quite sparse in a deep peripheral region due to severe under-sampling, which is an inherent property of LPM. To cope with such under-sampling, we determine the values of cumulative cells in Hough space by using the space-variant weighting. In our experiments, the proposed method demonstrates its validity of detecting not only the lines passing through both the fovea and periphery but also the lines in a deep periphery.