• Title/Summary/Keyword: line resistance

Search Result 1,374, Processing Time 0.028 seconds

Primary Resistance Compensation of Linear Induction Motor Using Thermocouple (Thermocouple을 이용한 선형 유도전동기의 1차측 저항 보상)

  • Kim, Kyung-Min;Park, Seung-Chan
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.742-747
    • /
    • 2006
  • This paper describes online stator-resistance estimation of a linear induction motor(LIM) with cage-type secondary using direct thrust control(DTC), where the resistance value is derived from stator-winding temperature estimation using thermocouple. In this paper, corrected stator resistance has an error in actuality measurement resistance. So compensation coefficient $\kappa$ which is decided through comparison and verifying several times relation of calculated resistance and measured motor line-line resistance. The stator-winding temperature information can also be used for monitoring, protection, and fault-tolerant control of the machine. Also, this paper reports the LIM's responses of the flux measured by the proposed stator resistance compensation algorithm.

  • PDF

Acquired Drug Resistance during Standardized Treatment with First-line Drugs in Patients with Multidrug-Resistant Tuberculosis (다제내성결핵 환자에서 표준 1차 항결핵제 치료 중 발생한 획득 내성)

  • Jeon, Doosoo;Kim, Dohyung;Kang, Hyungseok;Min, Jinhong;Sung, Nackmoon;Hwang, Soohee;Park, Seungkew
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.3
    • /
    • pp.198-204
    • /
    • 2009
  • Background: First-line drugs, if sensitive, are the most potent drugs in the treatment of multidrug-resistant tuberculosis (MDR-TB). This study examined the frequency and risk factors associated with acquired drug resistance to first-line drugs during a standardized treatment using first-line drugs in patients with MDR-TB. Methods: This study included patients who were diagnosed with MDR-TB at the National Masan Tuberculosis Hospital between January 2004 and May 2008, treated with standardized first-line drugs, and for whom the preand post-treatment results of the drug susceptibility test were available. Their medical records were reviewed retrospectively. Results: Of 41 MDR-TB patients, 14 (34.1%) acquired additional resistance to ethambutol (EMB) or pyrazinamide (PZA). Of 11 patients initially resistant to isoniazid (INH) and rifampicin (RFP), 3 (27.3%) acquired additional resistance to both EMB and PZA, and 3 (27.3%) to PZA. Of 18 patients initially resistant to INH, RFP and EMB, 6 (33.3%) acquired additional resistance to PZA. Of 6 patients initially resistant to INH, RFP and PZA, 2 (33.3%) acquired additional resistance to EMB. Ten of the 41 MDR-TB patients (24.4%) changed from resistant to susceptible. No statistically significant risk factors associated with acquired resistance could be found. Conclusion: First-line drugs should be used cautiously in the treatment of MDR-TB in Korea considering the potential acquisition of drug resistance.

Serum miR-19a Predicts Resistance to FOLFOX Chemotherapy in Advanced Colorectal Cancer Cases

  • Chen, Qi;Xia, Hong-Wei;Ge, Xiao-Jun;Zhang, Yu-Chen;Tang, Qiu-Lin;Bi, Feng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7421-7426
    • /
    • 2013
  • Background: Colorectal cancer is the fourth most common cancer worldwide and the second leading cause of cancer-related death. FOLFOX is the most common regimen used in the first-line chemotherapy in advanced colorectal cancer, but only half of the patients respond to this regimen and we have almost no clue in predicting resistance in such first-line application. Methods: To explore the potential molecular biomarkers predicting the resistance of FOLFOX regimen as the first-line treatment in advanced colorectal cancer, we screened microRNAs in serum samples from drug-responsive and drug-resistant patients by microarrays. Then differential microRNA expression was further validated in an independent population by reverse transcription and quantitative real-time PCR. Results: 62 microRNAs expressing differentially with fold-change >2 were screened out by microarray analysis. Among them, 5 (miR-221, miR-222, miR-122, miR-19a, miR-144) were chosen for further validation in an independent population (N=72). Our results indicated serum miR-19a to be significantly up-regulated in resistance-phase serum (p=0.009). The ROC curve analysis showed that the sensitivity of serum miR-19a to discriminate the resistant patients from the response ones was 66.7%, and the specificity was 63.9% when the AUC was 0.679. We additionally observed serum miR-19a had a complementary value for cancer embryonic antigen (CEA). Stratified analysis further revealed that serum miR-19a predicted both intrinsic and acquired drug resistance. Conclusions: Our findings confirmed aberrant expression of serum miR-19a in FOLFOX chemotherapy resistance patients, suggesting serum miR-19a could be a potential molecular biomarker for predicting and monitoring resistance to first-line FOLFOX chemotherapy regimens in advanced colorectal cancer patients.

Characteristics on the Neutral Point Potential of Line-to-Ground Voltage according to Line-to-Ground Fault in Resistance Ground System for Ships (선박의 저항접지 시스템에서 지락 고장에 따른 대지전압 중성점 전위 특성)

  • Lee, Yun-Hyung;Ryu, Ki-Tak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.689-696
    • /
    • 2018
  • System grounding is applied to the neutral point of a power source to secure the from any abnormal voltage and/or grounding fault. System grounding, which is applied mainly in ships is an ungrounded and resistance grounded system. Vessels using the MV power system with 3.3kV, 6.6kV, and 11kV mainly adopt a high resistance grounding system among the resistance grounding systems. The ground fault accounts for 95% of all faults occurring in the electrical system and when a fault occurs, the line-to-ground voltage of the power system is increased excessively, which adversely affects the onboard insulation system. This study analyzed the variation characteristics of the line-to-ground voltage neutral point according to the degree of ground fault in a resistance ground system applied in vessels. For this purpose, the characteristics of the grounding system were first explained, and the modeling of the neutral point potential of the line-to-ground voltage of the resistance grounding system in the vessels was derived. Finally, this study examined how the line-to-ground voltage, line voltage, and neutral point change according to various variable environments through MATLAB simulations.

Evaluation and Seed Increase of Sources of Resistance to Phytophthora capsici in Pepper (고추 역병 저항성 재료의 특성평가와 종자 증식)

  • Kim, Dong-Woo;Kim, Byung-Soo;Bae, Su-Yeon;Han, Jeong-Hye
    • Current Research on Agriculture and Life Sciences
    • /
    • v.20
    • /
    • pp.83-90
    • /
    • 2002
  • Resistance to Phytophthora Capsici and horticultural characteristics of selections from the resistance sources such as PI123469, PI201234, PI201232, AC2258 (=Line 29), CM334, KC268, KC358, KC820, KC821, KC822, KC823 (Line 29), KC462, KC463, KC464 were evaluated and recorded in the process of seed increase. Selections of PI123469, PI201234, PI201232, AC2258, KC823 (Line 29 = AC2258) of them showed the highest level of resistance. A considerable difference in the level of resistance was observed between lines selected from the same sources. The variation between selections derived from the same source was thought to be attributable to natural cross-pollination that may have occurred during the seed increase. Therefore, securing self-pollinated seed by wrapping the flower buds before anthesis would be necessary to obtain genetically pore resistant lines. The next alternative would be to increase the seed in small net houses for single line or field cage.

  • PDF

A Study on the Resistance Performance Under Hull Form of 18ft Leisure Boat with Carbon Composite Materials (탄소복합소재를 적용한 18ft급 레저보트의 수선하부 저항성능에 관한 연구)

  • Shin, Guk Hwan;Song, Jun Hee
    • Composites Research
    • /
    • v.34 no.6
    • /
    • pp.350-356
    • /
    • 2021
  • When a ship with a planing line operates or turns in a straight line, the floating position and trim change according to the speed, and a large resistance is generated on the hull. In this paper, the resistance to a planing line was estimated through the computational fluid dynamics of a leisure boat with improved hull weight and durability by applying a carbon composite material to the hull. The resistance performance of the bow and stern of the 18ft class leisure boat was checked and the flow field of the entire vessel was estimated, and the stability of the planing line was confirmed by comparing the resistance of each trim through numerical analysis. In addition, it was confirmed that the designed planing line could withstand it sufficiently because the force applied to the hull was not large, and The stability of the boat was analyzed by calculating the wavelength of the wave and the length of the ship as the ratio of gravity to the inertial force and checking how much force the rolling occurred.

Resistive displacement transducer enhanced measurement resolution by electrical line contact (선형 전기접촉으로 계측해상도가 향상된 저항성 변위센서)

  • Kim, Kyung-Ah;Choi, Seong-Su;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.263-269
    • /
    • 2007
  • Although variable resistance displacement transducer is widely applied for its technical simplicity, electrical point contact limits measurement resolution (precision). The present study introduced roller shaped structure for electrical line contact. Proto-type transducer was developed and measurement characteristics were compared with a commercialized product. When the displacement was varied with steps of 5 mm, 1 mm, and down to 0.1 mm, the correlation coefficient between resistance and displacement decreased lower than 0.9 in the commercialized product while the proto-type transducer maintained values higher than 0.99. Therefore, the measurement resolution was enhanced by approximately 10 times. Since manufacturing also seemed easier, the present results would enable more accurate and less expensive manufacturing of variable resistance displacement transducer.

Parameters On-line Identification of Dual Three Phase Induction Motor by Voltage Vector Injection in Harmonic Subspace

  • Sheng, Shuang;Lu, Haifeng;Qu, Wenlong;Guo, Ruijie;Yang, Jinlei
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.3
    • /
    • pp.288-294
    • /
    • 2013
  • This paper introduces a novel method of on-line identifying the stator resistance and leakage inductance of dual three phase induction motor (DTPIM). According to the machine mathematical model, the stator resistance and leakage inductance can be estimated using the voltage and current values in harmonic subspace. Thus a method of voltage vector injection in harmonic subspace (VVIHS) is proposed, which causes currents in harmonic space. Then the errors between command and actual harmonic currents are utilized to regulate the machine parameters, including stator resistance and leakage inductance. The principle is presented and analyzed in detail. Experimental results prove the feasibility and validity of proposed method.

Verification of Reliability by the Induced Voltage of a Downscaled and Simulated 22.9kV-Y Distribution Line (축소 모의된 22.9 kV-Y 배전선로의 유도 전압에 대한 신뢰성 검증)

  • Kim, Jeom-Sik;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.26-31
    • /
    • 2015
  • The purpose of this paper is to measure the induced voltage of the downscaled and simulated overhead ground wire of a 22.9kV-Y distribution line. This study performed a test of the downscaled and simulated distribution line according to whether it is grounded or not and the value of the ground resistance. In order to verify the reliability of the data measured by the test, the data was analyzed using the Minitab 17 program. It was found that the induced voltage of the downscaled and simulated distribution line is influenced by the value of the ground resistance. It was also found that the ground resistance obtained at a certain point is closely related to whether electric poles are grounded or not. The analysis results of the measured test data with a statistical method showed that the Anderson Darling (AD) was analyzed to be the smallest as 0.188 when the ground resistance of the electric poles had been maintained at $10{\Omega}$. In addition, the P value analyzed to be 0.894 which is in the proximity of the theoretical value of 1 and verified the reliability of the test data. It could be seen that the data measured by the downscaled simulation test forms a linear graph. It is thought that if a distribution line is installed in the same manner as the downscaled, simulated distribution line, the mean induced voltage will be reduced and reliability will be increased.