• Title/Summary/Keyword: line load

Search Result 1,862, Processing Time 0.029 seconds

A Study on Utility Interactive Energy System using PWM Converter (PWM 컨버터를 이용한 계통연계 에너지시스템에 관한 연구)

  • Kim, Gil-Dong;Lee, Han-Min;Hong, Yong-Ki;Kim, Dea-Gyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.288-291
    • /
    • 2007
  • Since the residential load is an AC load and the output of solar cell is a DC power, the photovoltaic system needs the DC/AC converter to utilize solar cell. In case of driving to interact with utility line, in order to operate at unity power factor, converter must provide the sinusoidal wave current and voltage with same phase of utility line. Since output of solar cell is greatly fluctuated by insolation, it is necessary that the operation of solar cell output in the range of the vicinity of maximum power point. In this paper, DC/AC converter is three phase PWM converter with smoothing reactor. And then, feedforward control used to obtain a superior characteristic for current control and digital PLL circuit used to detect the phase of utility line.

  • PDF

A Study on Parallel Operation Between Inverter System and Utility Line (인버터 시스템과 상용 전력 계통과의 병렬 운전에 관한 연구)

  • 천희영;박귀태;유지윤;안호균
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.4
    • /
    • pp.369-378
    • /
    • 1992
  • This paper proposes a utility parallel processing inverter system, which consists of a voltage source PWM inverter, isolation transformer and a reactor linking the inverter to utility line. This system realizes following functions : (1) voltage phase frequency and amplitude synchronization between inverter and utility line at stand-alone mode. (2) current phase synchronization between inverter and load at parallel mode. Therefore, despite sudden increase in load current over setting point at stand-alone mode, inverter system can be transferred into parallel mode immediately without transient current. Furthermore, high frequency(18KHz) PWM control and sinusoidal filtering improve the inverter output waveform by eliminating high order harmonic components as well as low order. As a switching device, IGBT is used for high frequency switching and large current capacity.

  • PDF

A Study on the Transient Characteristics in 765kV Untransposed Transmission Systems (765kV 비연가 송전계통 과도 특성에 관한 고찰)

  • 안용진;강상희
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.7
    • /
    • pp.397-404
    • /
    • 2004
  • This paper describes a study of transient characteristics in 765kV untransposed transmission lines. As the 765(kV) system can carry bulk power, some severe fault on the system nay cause large system disturbance. The large shunt capacitance and small resistance of 765kv transmission line make various difficulties for its protection. These problems including current difference between sending and receiving terminals on normal power flow, low order harmonic current component in fault current and current transformer saturation due to the long DC time constant of the circuit etc. must be investigated and solved. The analysis of transient characteristics at sending terminal has been carried out for the single phase to ground fault and 3-phase short fault, etc. The load current, charging current in normal condition and line flows, fault current, THD(Total Harmonic Distortion) of harmonics, time constants have been analysed for the 765kV untransposed transmission line systems.

The On-Line Economic Load Dispatch Program of Kwangyang Steel Works (광양제철소의 실시간 경제운용 프로그램 개발)

  • Kim, Jae-Chul;Baek, Young-Sik;Lee, Hee-Choon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.7
    • /
    • pp.318-323
    • /
    • 2001
  • This paper proposes an efficient method of On-Line Economic Load Dispatch(ELD) using Evolutionary Programming(EP) technique at KwangYang steel works. The economic operation of steel works is done by experienced engineer. So far, there is no formulation and algorithm of economic operation of steel works. In this paper, we propose the formulation and On-Line algorithm of economic operation of steel works. The EP technique is the kind of Evolutionary Computation(EC), which has become a candidate for many optimization applications due to its flexibility and efficiency. Based on the EP technique, the proposed algorithm is capable of not only solving the economic problem, but also obtaining the global optimal solutions within reasonable execution time. To validate our proposed approach, the algorithm is demonstrated on many sample systems and compared to actual values of steel works.

  • PDF

The On-Line Economic Load Dispatch Program of Kwangyang Steel Works (광양제철소의 실시간 경제운용 프로그램 개발)

  • Kim, Jae-Chul;Baek, Young-Sik;Lee, Hee-Choon
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.116-118
    • /
    • 2000
  • This paper proposes an efficient method of On-Line Economic Load Dispatch(ELD) using Evolutionary Programming(EP) technique at Kwangyang steel works. The economic operation of steel works is done by experienced engineer. So far, there is no formulation and algorithm of economic operation of steel works. In this paper, we propose the formulation and On-Line algorithm of economic operation of steel works. The EP technique is the kind of Evolutionary Computation(EC) which has become a candidate for many optimization applications due to its flexibility and efficiency. Based on the EP technique, the proposed algorithm is capable of not only solving the economic problem, but also obtaining the global optimal solutions within reasonable execution time. To validate our proposed approach, the algorithm is demonstrated on many sample systems and compared to actual values of steel works.

  • PDF

Dual-band L-section Impedance Transformer (이중 대역 L형 임피던스 변환기)

  • Park, Myun-Joo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.5
    • /
    • pp.67-71
    • /
    • 2010
  • This paper proposes new dual-band impedance transformers based on the L-section circuit topology. The proposed circuits consist of a transmission line section with a stub line either at the source or at the load end. The dual-band operating conditions are analyzed in detail and simple design equations are derived in terms of the line lengths and impedances for the different circuit topologies and load conditions. The dual-band operation is confirmed through the design, fabrication and measurement in microstrip circuits based on the proposed method.

Analysis of Line and Circular Contact Elastohydrodynamic Lubrication with Multigrid Multilevel Method (다중 격자 다중 차원법을 이용한 선접촉 또는 점접촉 탄성 유체 윤활 해석)

  • 장시열
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.323-330
    • /
    • 1999
  • The conventional analysis for the numerical computation of fluid film thickness with elastic deformation of contact region. is performed by Newton-Rephson method for its 18st convergence characteristics. However, both high load and relatively low sliding velocity frequently make it impossible for Newton-Rahpson method to get both converged and stable solutions. In particular, this method cannot provide converged Solution under the condition of high load above 1.0 GPa which frequently occurs in line contact of EHL problem. Multigird multi-level method for the solver of non-linear partial differential equation including solid deformation is preferred to Newton-Rshpson method for better convergence and stability and is applied to line contact EHL behavior in this study.

  • PDF

Application of SHE PWM Scheme for Reducing The Source Harmonic Components of Converter (콘버어터의 전원 고조파분을 저감시키기 위한 SHE PWM 방식의 적응)

  • Chung, Dong-Hwa
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.9
    • /
    • pp.1427-1435
    • /
    • 1990
  • This paper proposes the Selected Harmonic Elimination Pluse Width Modulation (SHE PW) scheme toreduce the ahrmonic components of source line current. To eliminate the low order harmonics which affects the source dominatly, we apply the Fourier series analysis to line current waveforms and then find out the switching patterns using the SHE PWM scheme. In addition to the analysis of harmonic effects, the three phase filter circuit is used to reduce high order harmonics. For the experimental realization, the converter circuit with power Transistor(PTR) is designed and the Pulse Time Control(PTC) is applied. The line current and the load voltage are measured under the condition of three phase application, highly inductive load.

  • PDF

Analysis of Voltage Stability in Electric Railway Feeding System (전기철도 급전계통의 집전전압 안정도 해석)

  • Lee Chang-Mu;Lee Han-Min;Han Moon-Seob;Kim Joo-Rak;Jung Ho-Seong
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1384-1389
    • /
    • 2004
  • The primary objective of this paper is to examine the capacity of electrical transmission in electric railway feeding system. Although supply capacity of railway substation are sufficient and there is no accident, due to the electrical transmission limit of feeding line the voltage breakdown may occur when large capacity of electric load at feeding line exist. So, using multi-port analysis model, we draw P-V curve due to the length of feeding line, load, location and power factor of electric locomotive. And through case study, compare measurement result and simulation result

  • PDF

Multi-Step Commutation and Control Policies for Matrix Converters

  • Hofmann, Wilfried;Ziegler, Marcus
    • Journal of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.24-32
    • /
    • 2003
  • The commutation and control in matrix converters is more complicated as in voltage source converters. Natural freewheeling paths do not exist and the theoretic absent storage elements result in a direct coupled system of load and line currents as well as voltages. The paper offers an overview about staggered commutation and control policies in matrix converters. Based on the knowledge about load current direction and the signs of the line to line input voltages different multi-step commutation policies were derived. This paper examines the application of that policies in the case of space vector modulation and direct control methods with the focus on the resulting effects to the reference output voltage deviation.