• Title/Summary/Keyword: line impedance

검색결과 935건 처리시간 0.028초

옥내 전력선 통신 채널 임피던스 측정 장치 설계 (Design of Channel Impedance Measurement Equipment for Indoor Power Line Communications)

  • 허윤석
    • 정보학연구
    • /
    • 제8권3호
    • /
    • pp.25-33
    • /
    • 2005
  • This paper describe a method for measuring line impedance as a function of frequency for an energized powerline in normal operation. A small sinusoidal signal of a powerline communication utility frequency 30khz$\sim$1Mhz band is continuously injected into the line, and a implemented impedance analyzer calculates the indoor powerline channel impedance from the measured magnitude and phase of resulting voltage and current. The impedance measurement is executed over a range of frequencies to produce a wideband impedance versus frequency characteristic. Implemented impedance analyzer can analysis powerline communication environments measuring line impedance due to load caused in indoor. And measured analysis information through the database can use to evaluate performance of modem and to decide test environment standard.

  • PDF

웨이브렛을 이용한 혼합송전선로에서의 거리계전 알고리즘 개선 (Improvement of Digital Distance Relaying Algorithm Using Wavelet Transform in Combined Transmission Line)

  • 정채균;김경호;하체웅;이종범;윤양웅
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권10호
    • /
    • pp.593-601
    • /
    • 2003
  • Distance realy is tripped by the line impedance calculated at the relay point. Accordingly the accurate operation depends on the precise calculation of line impedance. Impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding resistance, and sheath voltage limiters(SVLs). There are also several grounding systems in cable systems. Therefore, if there is a fault in cable systems, these terms will severely be caused much error to calculation of impedance. Accordingly the proper compensation should be developed for the correct operation of the distance relay. This paper presents the distance calculating algorithm in combined transmission line with power cable using wavelet transform. In order to achieve such purpose, judgement method to discriminate the fault section in both sections was proposed using D1 coefficient summation in db4. And also, error compensation value was proposed for correct calculation of impedance in power cables section.

mechanism of Equivalent Power Distribution in Parallel Connected ICP for Large Area Processing

  • 이진원;배인식;안상혁;장홍영;유신재
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.510-510
    • /
    • 2012
  • 반도체, 디스플레이, 태양광 등의 공정에서 사용되는 웨이퍼의 크기가 증가하고, 생산률이 플라즈마의 밀도에 비례한다는 연구 결과가 발표되면서 대면적 고밀도 플라즈마 소스 개발에 대한 연구가 활발히 진행되고 있다. 특히, ECR, ICP, Helicon plasma 등 고밀도 플라즈마 소스에 대한 관심이 높아지고 있다. 이에 따라, 여러 개의 ICP를 결합한 multiple ICP를 이용해 대면적 고밀도 플라즈마 소스 개발을 진행했다. Multiple ICP의 경우 각 ICP 소스에 같은 power (current)를 공급해야만 균일한 플라즈마 방전이 발생되어 균일도를 확보 할 수 있다. Current controller 같은 추가적인 장비를 설치하지 않고, power를 분배하는 transmission line을 coaxial 형태로 설계하고 같은 길이로 병렬 연결함으로써 각각의 ICP소스에서 균일한 플라즈마를 방전시킬 수 있었다. Power generator에서 보는 각 ICP의 total impedance는 각 ICP 소스의 impedance와 coaxial 형태의 transmission line의 characteristic impedance, frequency, 길이의 함수로 구할 수 있고, 이 total impedance가 일정하기 때문에 current가 균등하게 분배되어 각 ICP소스에 균등한 power 분배가 가능한 것이다. 실질적으로 ICP 소스의 impedance는 플라즈마 방전 유무에 따라 변화하기 때문에 일정하게 유지하는 것은 어렵다. Transmission line의 characteristic을 사용함으로써 ICP의 impedance의 변화에 상관없이 Total impedance를 일정하게 유지시킴으로써 균등한 power 분배가 가능하다는 것을 연구했다. Frequency는 13,56MHz, characteristic impedance를 $50{\Omega}$ (coaxial cable)으로 고정하고, ICP 소스의 플라즈마 방전 유무/antenna turn/소스 위치에 따른 total impedance를 transmission line의 길이에 따라 측정하고, 이를 이론값, 그래프와 비교하였다. 특정 length에서 플라즈마 방전 유무(ICP의 impedance 변화)와 상관없이 비교적 일정한 total impedance를 유지하는 것을 확인 했다. 이것은 특정 길이를 갖는 coaxial형태의 transmission line를 연결하면, total impedance는 플라즈마 방전 유무로 발생하는 ICP의 impedance 변화와 상관없이 일정하게 유지되어 각 ICP소스에 균등한 파워 분배가 가능하다는 것을 보여준 결과이다. 이것을 토대로 frequency에 따라(또는 characteristic impedance에 따라) 균등한 파워 분배가 가능한 coaxial 형태 transmission line의 특정 길이를 구할 수 있고, 대면적 소스에서 균등한 파워 분배를 위한 병렬연결에 적용할 수 있을 것이다.

  • PDF

저손실 광대역 동작 특성을 가지는 동축 선로 임피던스 변환기 제작 (The fabrication of a coaxial line impedance transformer with low transmission loss and wideband operation range)

  • 박웅희
    • 한국정보통신학회논문지
    • /
    • 제21권12호
    • /
    • pp.2241-2248
    • /
    • 2017
  • 동축 선로 임피던스 변환기는 동일 길이의 두 개 또는 그 이상의 동축 선로 결합을 이용하여 임피던스 변환을 만드는 회로로서 높은 동작 전력, 광대역 동작 특성, 쉬운 제작 등 다양한 장점에 의해 상대적으로 낮은 주파수 영역의 임피던스 정합을 위해 자주 사용된다. 본 논문에서는 두 개의 100mm 동축 선로를 이용한 4:1 임피던스 변환기를 사용하여 동축 선로의 위상 및 세기 특성을 측정하였다. 이를 통해 보조 동축 선로의 길이가 주 동축 선로보다 약 5mm 짧게 하는 것이 보다 저손실의 동축 선로 임피던스 변환기 구현에 효과적임을 알 수 있었다. 또한 4:1 임피던스 변환기와 1:4 임피던스 변환기를 직접 연결하여 측정한 동축 선로 임피던스 변환기의 전달 특성 실험을 통해 접지면과 주 동축선로 외곽 도체 입력부에 약 1pF 캐페시터를 연결하는 것이 보다 광대역 동작 범위 및 대역 내 특성 개선에 도움이 됨을 알 수 있었다.

고압전력선 통신을 위한 임피던스 측정 및 정합 방안 연구 (Impedance Measurement and Matching Technique for Medium-Voltage Powerline Communication)

  • 이재조;유정훈;홍충선;이대영
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권5호
    • /
    • pp.345-352
    • /
    • 2004
  • Currently, high data rate PLC(Power Line Communications), up to 100 Mbps, which use frequency bandwidth between 2 MHz and 30 MHz is investigated very hard, and commercial PLC modem for low voltage powerline network (indoor) is coming soon into communication market. For the purpose of developing a fit communication system which has little distortion of signal and attenuation, it is surely necessary to know about channel environments of powerline. Especially, the impedance measurement of the powerline and impedance matching are very important. As is known, since medium-voltage powerline (22.9 ㎸) is still working, it is not so simple to measure the powerline impedance. In our study, a portable impedance measurement equipment is developed. It consists of coupling capacitor, a drain coil and impedance matching transformer. The equipment is easily connected to medium voltage line and impedance of power line is measured using a network analyzer. Also, measurement results are used for impedance matching of PLC signal. In fact, matching transformer with several different impedances are used. The matching transformer is connected between coupling capacitor and signal port. In this paper, the developed portable impedance measurement equipment and impedance measurement results are presented. Also impedance matching technique using matching transformers will be explained. We showed the result of the improved performance by the impedance matching.

DGS를 이용한 가변 임피던스 선로 특성에 관한 연구 (A Study on the Characteristic of Variable Impedance Line using DGS)

  • 김영주;정명섭;박준석;조홍구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권1호
    • /
    • pp.35-40
    • /
    • 2005
  • In this paper, we designed and fabricated the variable impedance line by using the DGS(Defected Ground Structure) which is useful in mounting the external lumped elements. Also we used a varactor diode as Control device stuff at the proposed variable impedance line. We are able to change the impedance of transmission line as varied the capacitance of varactor diode by adjusting DC bias. The impedance variation of the proposed DGS line is about maximum 70 Ω. We will study about the application of DAM(Direct antenna modulation) in the future work.

전기철도에서 급전선로의 line impedance 계산에 관한 연구 (A study on the Line impedance calculation method in electrified railway system)

  • 이춘배;이종우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1308-1312
    • /
    • 2004
  • Transmission line impedance calculation has been tried for obtaining exact value. The method proposed by Carson contains indefinite complex integral. Although the Carson solution is proposed with power series, the solution is limited and valid at special range of frequency. In this paper, we proposed a simplified Carson solution by analytical method using ground transmission line return current. This method calculate the transmission line impedance easily.

  • PDF

옥내 전력선 통신 채널 임피던스 특성 측정 (Measurement of Channel Impedance Characteristics for Indoor Power Line Communications)

  • 허윤석;김철;홍봉화;이대영;전계석
    • 대한전자공학회논문지TC
    • /
    • 제42권11호
    • /
    • pp.79-86
    • /
    • 2005
  • 본 논문에서는 정상적으로 전기가 공급되고 있는 전력선상에서 주파수의 함수로 표현되는 임피던스 측정 방법을 기술한다. 측정방법으로 전력선 통신사용 주파수 $30Khz\~1Mhz$ 대역의 미소 신호를 연속적으로 전력선에 주입하고, 구현한 임피던스 측정 장치는 측정된 전압과 전류의 크기와 위상으로부터 옥내 채널 임피던스를 계산한다. 임피던스 측정에 있어 광대역 주파수 범위의 임피던스 대 주파수 특성을 수행한다. 구현된 임피던스 측정 장치는 옥내에서 발생하는 부하에 의해 변화하는 전력선 임피던스를 측정하여 전력선 통신 환경을 분석할 수 있는 장비이다. 측정된 데이터는 데이터베이스화 하여 전력선 통신 모뎀의 통신성능 평가 및 테스트 환경 기준 설정에 유용하게 사용될 수 있을 것이다.

A Coupled-Line Type Waveguide Bandpass Filter using Normalized Impedance Concept

  • Park, Jun-Seok;Kim, Young-Tae;Kim, Sun-Hyeong;Lim, Jae-Bong;Cho, Hong-Goo
    • Journal of electromagnetic engineering and science
    • /
    • 제3권2호
    • /
    • pp.126-132
    • /
    • 2003
  • In this paper, a coupled-line type waveguide bandpass filter is newly proposed. The proposed bandpass filter configuration consists of magnetically coupled waveguide cavities. In order to show the background of the proposed waveguide bandpass filter, the general coupled line TEM bandpass filter theory, which means the coupled line filter with arbitrary coupled line length and impedance level, will be briefly introduced. Calculations for the even- and odd-mode wave impedance of a coupled line waveguide structure are achieved based on the normalized impedance concept for a broad-side coupled waveguides by using vector finite element method(VFEM) calculation. Measured result of an implemented coupled-line type waveguide filter is presented.

임피던스 변환회로의 신호 전달특성(S21) 측정 방법 (Measurement method of the signal transfer characteristic(S21) of the impedance transformer)

  • 박웅희
    • 한국정보통신학회논문지
    • /
    • 제23권10호
    • /
    • pp.1282-1289
    • /
    • 2019
  • 임피던스 변환회로의 신호 전달특성(S21)을 측정하기 위해서는 두 개의 임피던스 변환회로를 대칭 연결하여야 한다. 하지만 두 개의 임피던스 변환회로를 대칭 연결한 회로의 신호 전달특성은 중간 연결 선로의 길이에 의해 영향을 받는다. 본 논문에서는 임피던스 변화회로의 정확한 신호 전달특성을 얻기 위한 중간 연결 선로의 길이를 수식으로 유도하였다. 수식을 이용하여 계산하면 4:1(50-Ω:12.5-Ω) 임피던스 변환회로의 정확한 신호 전달특성을 얻기 위한 중간 연결 선로의 전기적 길이는 약 45°이다. 계산된 연결 선로의 길이를 적용하여 1GHz에서 λ/4-마이크로스트립 임피던스 변환회로를 제작하여 신호 전달특성을 측정하였다. 제작된 대칭 연결된 임피던스 변환회로의 신호 반사 특성(S11)은 0.980GHz에서 -40.64dB, 신호 전달 특성(S21)은 -0.154dB였다. 이는 제작 회로에 대해 이론적으로 살펴본 중심 주파수의 987MHz 변화, 마이크로스트립 선로의 신호 손실 -0.15dB 값과 거의 동일한 값이다.