• 제목/요약/키워드: line center

검색결과 4,368건 처리시간 0.035초

열연 공정에서의 영상을 이용한 캠버 및 최적 절단선 검출 알고리즘 (Vision-Based Camber and Optimal Cutting Line Detection Algorithm for Hot-Rolling Process)

  • 공남웅;문정혜;박부견
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.155-156
    • /
    • 2007
  • This paper presents the vision-based camber and optimal cutting line detection algorithm for hot-rolling process. It is important to measure the camber of head and tail part of strips because many problems are caused by the camber in the hot-rolling process. The hot-rolling process has time constraints. The camber detection algorithm of head and tail parts requires fast and less complex for satisfying time constraints. The proposed algorithm consists of two parts: measurement of the camber in the head and tail part of strips and decision part of the optimal cutting line of hot-rolled strip. First, we obtain the camber value of the strip from the difference between the real center line and the center line of head, tail part. Second, the head and tail part of strips isn't suitable for strips connections. Therefore, the cutting process is needed in the hot-rolling process. The optimal cutting line is determined by the head and tail images obtained from cameras. The algorithm is applied into the vision system with two area cameras, Matrox image processing board and host PC for verification.

  • PDF

Investigating the accretion disk properties of young radio galaxies using the narrow-emission line diagnostics

  • 손동훈;우종학;;;;;김상철
    • 천문학회보
    • /
    • 제36권1호
    • /
    • pp.49.2-49.2
    • /
    • 2011
  • To investigate whether radio galaxies have systematically different accretion disk compared to radio-quiet AGN, we obtained high quality optical spectra for a sample of 22 young radio galaxies, using the KAST Double Spectrograph at the Lick 3-m telescope. Young radio galaxies are particularly useful since the age of the radio phenomena is comparable to that of accretion disk. Based on the optical emission-line diagnostics of narrow line region, which is thought to be photoionized by the nuclear radiation, we constrain the states of the accretion disk. In addition to strong emission lines, i.e., [O I], [O II], [O III], and [Ne III], we use the [Ar III] line to break the degeneracy between the ionization parameter and the SED shape. We find that young radio galaxies show systematically different emission line ratios compared to radio-quiet Type II AGN, suggesting that young radio galaxies probably have the power-law SED without a strong big blue bump. We will present the main results of the emission-line diagnostics.

  • PDF

STUDY OF M82 USING SPECTRA FROM THE INFRARED SPACE OBSERVATORY

  • SOHN JUNGJOO;ANN H. B.;PAK SOOJONG;LEE H. M.
    • 천문학회지
    • /
    • 제34권1호
    • /
    • pp.17-24
    • /
    • 2001
  • We have studied the central parts of M82, which is a well-known infrared luminous, starburst galaxy, by analyzing archival data from the Infrared Space Observatory (ISO). M82 was observed at 11 positions covering $\pm$45" from the center along the major axis. We analyzed 4 emission lines, [ArIII] 8.99 ${\mu}m$, $H_2$ 17.034 ${\mu}m$, [FeII] 25,98 ${\mu}m$, and [SiII] 34,815 ${\mu}m$ from $SWSO_2$ data. The integrated flux distributions of these lines are quite different. The $H_2$ line shows symmetric twin peaks at $\~$18" from the center, which is a general characteristic of molecular lines in starburst or barred galaxies. This line appears to be associated with the rotating molecular ring at around $\~$200 pc just outside the inner spiral arm. The relative depletion of the $H_2$ line at the center may be due to the active star formation activity which dissociates the $H_2$ molecules. The other lines have peaks at the center and the distributions are nearly symmetric. The line profiles are deconvolved assuming that both intrinsic and instrumental profiles are Gaussian. The velocity dispersion outside the core is found to be $\~50 km s^{-1}$. The central velocity dispersion is much higher than $50 km s^{-1}$, and different lines give different values. The large central velocity dispersion ($\sigma$) is mostly due to the rotation, but there is also evidence for a high $\sigma$ for [ArIII] line. We also generated position-velocity maps for these four lines. We found very diverse features from these maps.

  • PDF

Bale Location Effects on Nutritive Value and Fermentation Characteristics of Annual Ryegrass Bale Stored in In-line Wrapping Silage

  • Han, K.J.;McCormick, M.E.;Derouen, S.M.;Blouin, D.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제27권9호
    • /
    • pp.1276-1284
    • /
    • 2014
  • In southeastern regions of the US, herbage systems are primarily based on grazing or hay feeding with low nutritive value warm-season perennial grasses. Nutritious herbage such as annual ryegrass (Lolium multiflorum Lam.) may be more suitable for preserving as baleage for winter feeding even with more intensive production inputs. Emerging in-line wrapped baleage storage systems featuring rapid wrapping and low polyethylene film requirements need to be tested for consistency of storing nutritive value of a range of annual ryegrass herbage. A ryegrass storage trial was conducted with 24-h wilted 'Marshall' annual ryegrass harvested at booting, heading and anthesis stages using three replicated in-line wrapped tubes containing ten round bales per tube. After a six-month storage period, nutritive value changes and fermentation end products differed significantly by harvest stage but not by bale location. Although wilted annual ryegrass exhibited a restricted fermentation across harvest stages characterized by high pH and low fermentation end product concentrations, butyric acid concentrations were less than 1 g/kg dry matter, and lactic acid was the major organic acid in the bales. Mold coverage and bale aroma did not differ substantially with harvest stage or bale location. Booting and heading stage-harvested ryegrass baleage were superior in nutritive value to anthesis stage-harvested herbage. Based on the investigated nutritive value and fermentation characteristics, individual bale location within in-line tubes did not significantly affect preservation quality of ryegrass round bale silages.

MS-HEMs: An On-line Management System for High-Energy Molecules at ADD and BMDRC in Korea

  • Lee, Sung-Kwang;Cho, Soo-Gyeong;Park, Jae-Sung;Kim, Kwang-Yeon;No, Kyoung-Tae
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권3호
    • /
    • pp.855-861
    • /
    • 2012
  • A pioneering version of an on-line management system for high-energy molecules (MS-HEMs) was developed by the ADD and BMDRC in Korea. The current system can manage the physicochemical and explosive properties of virtual and existing HEMs. The on-line MS-HEMs consist of three main routines: management, calculation, and search. The management routine contains a user-friendly interface to store and manage molecular structures and other properties of the new HEMs. The calculation routine automatically calculates a number of compositional and topological molecular descriptors when a new HEM is stored in the MS-HEMs. Physical properties, such as the heat of formation and density, can also be calculated using group additivity methods. In addition, the calculation routine for the impact sensitivity can be used to obtain the safety nature of new HEMs. The impact sensitivity was estimated in a knowledge-based manner using in-house neural network code. The search routine enables general users to find an exact HEM and its properties by sketching a 2D chemical structure, or to retrieve HEMs and their properties by giving a range of properties. These on-line MS-HEMs are expected be powerful tool for deriving novel promising HEMs.

A Coupled Line Impedance Transformer for High Termination Impedance with a Bandpass Filtering Response

  • Kim, Phirun;Jeong, Yongchae
    • Journal of electromagnetic engineering and science
    • /
    • 제18권1호
    • /
    • pp.41-45
    • /
    • 2018
  • In this study, a short-ended coupled line with a short-circuit stub transmission line bandpass filtering impedance transformer is presented. The general designed equations are derived on the basis of circuit theory. The design curves are provided to examine the characteristic of the proposed impedance transformer. The proposed circuit is suitable for high termination impedance. To validate the design formulas, a $400-50{\Omega}$ impedance transformer is designed and fabricated at the operating center frequency ($f_0$) of 2.6 GHz. The measured results show a good agreement with the simulation. The measured insertion and return losses are 0.6 dB and 22.5 dB at $f_0$, respectively. The measured return loss is higher than 20 dB within the passband frequency of 2.51-2.7 GHz. Moreover, the stopband attenuation is higher than 25 dB from DC to 1.64 GHz of the lower stopband and from 3.12 GHz to 6.4 GHz of the higher stopband.

Development of Defect Inspection System for PDP ITO Patterned Glass

  • Song Jun-Yeob;Park Hwa-Young;Kim Hyun-Jong;Jung Yeon-Wook
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제7권3호
    • /
    • pp.18-23
    • /
    • 2006
  • The formation degree of sustain (ITO pattern) determines the quality of a PDP (Plasma Display Panel). Thus, in the present study, we attempt to detect 100% of the defects that are larger than $30{\mu}m$. Currently, the inspection method in the PDP manufacturing process is dependent upon the naked eye or a microscope in off-line mode. In this study, a prototype inspection system for PDP ITO patterned glass is developed. The developed system, which is based on a line-scan mechanism, obtains information on the defects and sorts the defects by type automatically. The developed inspection system adopts a multi-vision method using slit-beam formation for minimum inspection time and the detection algorithm is embodied in the detection ability. Characteristic defects such as pin holes, substances, and protrusions are extracted using the blob analysis method. Defects such as open, short, spots and others are distinguished by the line type inspection algorithm. It was experimentally verified that the developed inspection system can detect defects with reliability of up to 95% in about 60 seconds for the 42-inch PDP panel.

진동둘레선 설계를 위한 진동체표변화에 관한 연구 (Body Surface Changes at Armhole Area for the Pattern of Armhole Line)

  • 이정란;임원자
    • 한국의류학회지
    • /
    • 제20권5호
    • /
    • pp.930-942
    • /
    • 1996
  • This study was done to provide the characteristics of body surface changes at armhole area. Experiments were carried out at upper arm and upper body inchuding 67 items, 74 segments by the stanard posture and arm movements. The subjects were 15 females of twenty aged. The major conclusions of this study are; 1. On the circumference items of upper arm, armhole circumference was decreased by all arm movement, especially high contracted on front armhole line. The most contracted segments of armhole circumference were from the shonlder point to front and back interscye breadth point. Axillary circumference was increased 5 cm to the utmost, so the function of sleeve pattern would be decided by axillary circumference. 2. The lengths of upper arm were decreased near center line, sleeve cap length was contracted 3∼4 cm. Posterior armpit point area was increased both length and breadth. According to the rates of expansion and contraction, the diagram of expansion and contraction of upper arm was suggested. 3. On upper body, back side chest breadth was increased exceedingly and shoulder length was decreased most. It was apparent that surface changes of upper body were greatly larger as far away from center front and center back line. The rates of expansion and contraction of upper body were also represented as a diagram of surface changes.

  • PDF

생물공정 모니터링을 위한 광섬유 포도당 및 젖산 센서의 개발 (Development of Optical Fiber Glucose and Lactate Biosensors for Bioprocess Monitoring)

  • 정창환;손옥재;이종일
    • KSBB Journal
    • /
    • 제32권1호
    • /
    • pp.35-45
    • /
    • 2017
  • In this work the optical fiber glucose and lactate biosensors were developed by using fluorescent dye and enzyme immobilized on the end tip of an optical fiber. 3-Glycidyloxypropyl)methyldiethoxysilane (GPTMS), (3-Aminopropyl) trimethoxysilane (APTMS) and Methyltrimethoxysilane (MTMS) were used to immobilize glucose oxidase (GOD), lactate oxidase (LOD) and ruthenium(II) complex (tris(4,7-diphenyl-1,10-phenanthroline) ruthenium(II), $Ru(dpp)_3^{2+}$) as oxygen sensitive fluorescent dye. MTMS sol-gel was an excellent supporting material for the immobilization of $Ru(dpp)_3^{2+}$, GOD, and LOD on the optical fiber. Storage stability of the optical fiber glucose sensor was kept constant over 20 days, while the optical fiber lactate sensor had constant storage stability over 17 days. The optical fiber glucose and lactate biosensors also maintained good operational stability for 20 hours and 14 hours, respectively. The activities of the immobilized enzymes were most excellent at pH 7 and at $25^{\circ}C$. On-line monitoring of glucose and lactate in a simulated process was performed with the optical fiber glucose and lactate biosensors. On-line monitoring results were agreed with those of off-line data measured with high performance liquid chromatography (HPLC).

EFFECTS OF COLLISIONAL DE-EXCITATION ON THE RESONANCE DOUBLET FLUX RATIOS IN SYMBIOTIC STARS AND PLANETARY NEBULAE

  • Kang, Eun-Ha;Lee, Hee-Won
    • 천문학회지
    • /
    • 제41권3호
    • /
    • pp.49-58
    • /
    • 2008
  • Resonance doublets including O VI 1032, 1038, NV 1239, 1243 and C IV 1548, 1551 constitute prominent emission lines in symbiotic stars and planetary nebulae. Spectroscopic studies of symbiotic stars and planetary nebulae from UV space telescopes show various line ratios of these doublets deviating from the theoretical ratio of 2:1. Using a Monte Carlo technique, we investigate the collisional de-excitation effect in these emission nebulae. We consider an emission nebula around the hot component of a symbiotic star characterized by the collisional de-excitation probability $p_{coll}\;{\sim}\;10^{-3}\;-\;10^{-4}$ per each resonance scattering, and the line center optical depths for major resonance doublets in the range ${\tau}_0\;{\sim}\;10^2\;-\;10^5$. We find that various line ratios are obtained when the product $p_{coll}{\tau}_0$ is of order unity. Our Monte Carlo calculations show that the flux ratio can be approximately fitted by a linear function of ${\log}{\tau}_0$ when ${\tau}_0p_{coll}\;{\sim}\;1$. It is briefly discussed that this corresponds to the range relevant to the emission nebulae of symbiotic stars.