• 제목/요약/키워드: line bundle

검색결과 81건 처리시간 0.027초

풍소음 저감용 특수 다중도체 방식의 3차원 전계해석 (3-Dimensional Analysis on Electric Field of Special Conductor Bundle for Reducing Aeolian Noise)

  • 민석원;송기현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.254-258
    • /
    • 2001
  • In this paper, 3-dimensional charge simulation method was developed to analyze electric field distributions of special conductor bundles equipped with spiral rods for reducing aeolian noise. When we applied this method to 765 kV double circuit transmission line, we found calculation error of this method was within a reasonable boundary of 1%.

  • PDF

Development of On -Line Work Roll Surface Monitoring System At Hot Strip Mill

  • Moon, Bae-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.53.4-53
    • /
    • 2001
  • This paper described about the system which can be inspect work roll surface for deciding a milling schedule and roll changing at hot strip mill in POSCO. Developed system consists of CCD camera, Xenon lamp with fiber bundle and mechanical control part. The water probe build up water pole between head of probe and roll surface to acquisite a good image from a work roll surface under the bad environment with steam, cooling water and high temperature. This system is possible to monitor a work roll surface of about 12${\times}$9mm. We have shown the validation of the developed system which can monitor the evolution of degradation on work roll surface.

  • PDF

자탈형 콤바인 탈곡부 설계요인(設計要因)의 적정화(適正化)를 위한 연구(I) -급동축(扱胴軸) 토오크 파형의 추정(推定)- (Optimizing the design factors of the head-fed type combine(I) -Estimation of the threshing drum torque curve-)

  • 남상일;정창주;호소카와 아키라
    • Journal of Biosystems Engineering
    • /
    • 제12권3호
    • /
    • pp.42-49
    • /
    • 1987
  • The threshing action of the head-fed type threshing unit occurs mainly by the impact between threshing tooth and grains. It may be therefore the most fundamental step to calculate the time and order of the occurrance of impact by the tooth for predicting the performance of threshing unit. The threshing teeth arrangement was defined by length and diameter of threshing dram, number of spiral arrays, number of threshing teeth by kind per one spiral array, number of windings of spiral array around the threshing drum, delay angle of impact line. The linear equations for locus of left and right margin of paddy bundle, spiral array, impact line on the development figure of the threshing drum were expressed by fastors of the threshing teeth arrangement. In the computer program, the teeth which inflict impact were searched successively along the impact line. Searching range and impact condition were defined by the relation between four linear equations. If the impacting tooth was found, time and the kind of threshing tooth was derived from the coordinate of the threshing tooth. At this time the unit torque curve was accumulated on the array of computer memory. At last the completed torque curve of threshing drum shaft was described on the computer screen. Remarkably the peack valae and fluctuation of torque curve was decreased by adopting the delay angle of impact line.

  • PDF

차기 초고압 송전선로의 도체방식 선정을 위한 환경설계 연구 (An Environmental Design Study for selecting Conductor Configurations of the next Extra High Voltage Transmission Line)

  • 박동욱;안희성;양광호;김정부;정상진;민석원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.197-200
    • /
    • 1989
  • The corona interference of extra high voltage (EHV) transmission lines has to be considered as an important design factor for establishing an electrical environmental countermeasure at a basic line design stage. This paper describes the conductor selection procedure through both corona performance test result in corona cage and its evaluation by the design criterion. It is known that three conductor configurations including $6{\times}810mm^2$ (spacing: 40 cm) are the suitable conductor bundle for the environmental preservation around both 2-circuits and 1-circuit T/L.

  • PDF

ENDOMORPHISMS OF PROJECTIVE BUNDLES OVER A CERTAIN CLASS OF VARIETIES

  • Amerik, Ekaterina;Kuznetsova, Alexandra
    • 대한수학회보
    • /
    • 제54권5호
    • /
    • pp.1743-1755
    • /
    • 2017
  • Let B be a simply-connected projective variety such that the first cohomology groups of all line bundles on B are zero. Let E be a vector bundle over B and $X={\mathbb{P}}(E)$. It is easily seen that a power of any endomorphism of X takes fibers to fibers. We prove that if X admits an endomorphism which is of degree greater than one on the fibers, then E splits into a direct sum of line bundles.

가공송전선로의 소도체 구성방식에 따른 전기적 특성 해석 (An Analysis of Electrical Characteristics for Bundled Conductor Configurations in Overhead Transmission Lines.)

  • 정연호;손홍관;이형권;조연규;신복덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.245-247
    • /
    • 1998
  • Compacting of Overhead power transmission lines can be helpful in solving many problems, such as reduction of land and forest losses. decrease of the line's environmental impact zones, improvement of its electrical performance. And in overhead transmission lines, regular polygon configuration of bundled conductors are considered and adopted. This papers are compared to subconductor surface charges and electric field gradients, line parameters, natural capacities for regular polygon and modified configurations in 345kV 4 bundle 2 circuits horizontal type transmission lines.

  • PDF

765kV 시험선로를 이용한 전기환경장해 특성연구 (Study on Electrical Environmental Obstacle Using a 765kV Double Circuit Test Line)

  • 김정부;조성배;신구용;이동일;양광호;안희성;배정효;구자윤;민원석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1517-1519
    • /
    • 1994
  • This paper describes electrical environmental study of a 765kV double circuit test line. Corona performance on several candidate conductor bundles has been investigated in the corona cage (single phase simulation facility) since 1984. We have known that six RAIL conductor bundle is the most suitable for the 765kV transmission Line, [3] To investigate electrical environmental impact of the future commerciale line, we build a full sacle 765kV test line in 1993. The test results of Audible Noise, Radio Interference, TV Interference from August, 1993 to Jan. 1994 were measured as $48.7[dBA](L_{50})$. $57.4[dB{\mu}V/m]$(Fair weather, $L_{50})$. $14.5[dB${\mu}$V/m]$(Fair weather, $L_{50}$). We have found that the Audible Noise data were very close to the predicted(48.5 [dBA]) by BPA Corona and Field Effects Computer program, however, the RI and TVI data were much higher than predicted(42 [dBmV/m], $7.9[dB{\mu}V/m)$ by the BPA program. We have investigating the reason of the difference. In the constructing of full scale test line, we developed the tubular tower, 765kV test transformer and hardwares of 765kV transmission line insulator strings. Also we will investigate the effects of plants under the 765kV test Line.

  • PDF

765kV 송전선로용 저풍소음 복도체 방식의 코로나 특성 모의실험 (Simulation on the Corona Characteristics of Low Aeolian Noise Conductor Bundles for 765 kV Transmission Line)

  • 주문노;양광호;신구용;이동일;민석원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.131-133
    • /
    • 2000
  • Single phase simulations were carried out in order to determine a solutive conductor to the aeolian noise which will be locally applied to 765 kV transmission lines Basic solutive conductors have already been proposed including conductors equipped with spiral rod. low noise conductor of a special shape and others. A low aeolian noise conductor, however, should have excellent corona characteristics in addition to aeolian noise reduction function. In this paper, we compared the performances of the audible noises and radio interferences of 6 candidate conductor bundles by using corona cage. We also developed two programs to need for evaluating environmental effects of each conductor bundle. Those are a program to calculate the conductor surface gradient of various special bundles and a conversion program of single phase data to the model of transmission line. The future determination on the final low aeolian noise conductor will be made through a long-term test to verify environmental impacts at the full-scale Kochang 765 kV test line.

  • PDF

자동클램핑 장치형 Spacer Damper 설계 (Design of the Spacer Damper with Automatic Clamping Device for Transmission Line)

  • 박종범;안용호;윤기갑;김광우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1790-1795
    • /
    • 2000
  • 송전선로에 새로운 Spacer damper를 설계하는데 이 논문의 목적이며, 이 설계되는 새로운 Spacer damper는 매우 중요한 특징과 장점을 가지고 있다. 또한, 최근 Spacer damper의 문제가 프랑스, 일본 등 다른 나라에서도 자동화 시스템과 함께 많이 발전되어 왔다. 개발된 Spacer damper외 설치는 특별한 기기없이 설치가능하며, 최근 자동 클램핑 장치 이용한 Spacer damper가 도입되어 피로 파괴와 미풍진동에 매우 효과적임이 입증되었고 보수유지가 거의 필요없으므로 경제성도 높으나 고가의 수입가격으로 인해 국산화의 필요성이 절실하다.

  • PDF