• Title/Summary/Keyword: lightning

Search Result 910, Processing Time 0.024 seconds

Pspice Simulation for Nonlinear Components and Surge Suppression Circuits (비선형 소자 및 서지억제회로의 Pspice 시뮬레이션)

  • Lee, Bok-Hui;Gong, Yeong-Eun;Choe, Won-Gyu;Jeon, Deok-Gyu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.8
    • /
    • pp.477-486
    • /
    • 2000
  • This paper presents Pspice modeling methods for spark gaps and ZnO varistors and describes the application for the two-stage surge suppression circuit which was composed of the nonlinear components. The simulation modelings of nonlinear components were conducted on the basis of the voltage and current curves measured by the impulse current with the time-to-crest of $1~50 \mus$ and the impulse voltage with the rate of the time-to-crest of 10, 100 and 1000 V/\mus$. The firing voltages of the spark gap increased with increasing the rate of the time-to-crest of impulse voltage and the measured data were in good agreement with the simulated data. The I-V curves of the ZnO varistor were measured by applying the impulse currents of which time-to-crests range from 1 to $50 \mus$ and peak amplitudes from 10 A to 2 kA. The simulation modeling was based on the I-V curves replotted by taking away the inductive effects of the test circuit and leads. The meximum difference between the measured and calculated data was of the order of 3%. Also the two-stage surge suppression circuit made of the spark gap and the ZnO varistor was investigated with the impulse voltage of $10/1000\mus$$mutextrm{s}$ wave shape. The overall agreement between the theoretical and experimental results seems to be acceptable. As a consequence, it was known that the proposed simulation techniques could effectively be used to design the surge suppression circuits combined with nonlinear components.

  • PDF

A Study on the microstructure and Surge Characteristics of ZnO varistors for distribution Arrester (배전급 피뢰기용 ZnO 바리스터 소자의 미세구조 및 서지 특성에 관한 연구)

  • 김석수;조한구;박태곤;박춘현;정세영;김병규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.2
    • /
    • pp.190-197
    • /
    • 2002
  • In this thesis, ZnO varistors with various formulation, such as A∼E, were fabricated according to ceramic fabrication method. The microstructure, electrical properties, and surge characteristics of ZnO varistors were investigated according to ZnO varistors with various formulation. In the microstructure, A∼E\`s ZnO varistor ceramics sintered at 1130$\^{C}$ was consisted of ZnO grain(ZnO), spinel phase (Zn$\_$2.33/Sb$\_$0.67/O$\_$4/), Bi-rich phase(Bi$_2$O$_3$) and intergranuler phase, wholly. Lightning impulse residual voltage of A, B, C and E\`s ZnO varistors suited standard characteristics, below 12kV at current of 5kA. On the contrary, D\`s ZnO varistor exhibited high residual voltage as high reference voltage. In the accelerated aging test, leakage current and watt loss of B, C and D\`s ZnO varistors increases abruptly with stress time under the first a.c. stress(115$\^{C}$/3.213kV/300h). Consequently, C varistor exhibited a thermal run away. On the contrary, leakage current and watt loss of A and C\`s ZnO varistors which show low initial leakage current exhibited constant characteristics. After high current impulse test, A\`s ZnO varistor has broken the side of varistor but impulse current flowed. On the contrary, E\`s ZnO Varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After long duration impulse current test, E\`s ZnO varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After high current impulse test and long duration impulse current test, E\`s ZnO varistor exhibited very good characteristics which variation rate of residual voltage is 1.4% before and after test.

Evaluation of Electrical Characteristics of Metal Oxide Varistors for Surge Arresters (초고압용 피뢰기 산화아연소자의 전기적 특성 평가)

  • Cho, Han-Goo;Yoon, Han-Soo;Kim, Suk-Soo;Han, Se-won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.46-49
    • /
    • 2005
  • This paper presents the electrical characteristics of metal oxide varistors for lightning surge arresters. ZnO varistors were fabricated with typical ceramic production methods and two types of varistors were also prepared to be compared. The nominal discharge current and line discharge class of those varistors are $10kA(8/20{\mu}s)$ and class 3, respectively. The diameter of varistors manufactured and prepared were in the range of 61.6~65.0mm and the thickness of those were in the range of 27~42.52mm. The reference and residual voltage were tested and reference and residual voltage per 1mm and the ratio of reference and residual voltage were calculated. The reference voltage per 1mm of varistors manufactured was about 175V/mm but that of A's and B's varistors was nearly 200V/mm. The residual voltage exhibited the same trends as the reference voltage, so the reference and residual voltage per 1mm of domestic varistors should be increased. According to the results of tests, it is thought that if the reference and residual voltage per 1mm were increased to 200V/mm and 330V/mm, domestic ZnO varistors would be possible to apply to the station class arresters in the near future.

  • PDF

극소형 MEMS 우주망원경 탑재체 개발 및 탑재

  • Lee, Jik;Kim, Ji-Eun;Na, Go-Un;Nam, Sin-U;Nam, Ji-U;Park, Il-Heung;Seo, Jeong-Eun;Lee, Hye-Yeong;Jeon, Jin-A;Jeong, Su-Min;Jeong, Ae-Ra;Park, Jae-Hyeong;Lee, Chang-Hwan;Park, Yong-Seon;Yu, Hyeong-Jun;Kim, Min-Su;Kim, Yong-Gwon;Yu, Byeong-Uk;Lee, Gyeong-Geon;Jin, Ju-Yeong;G., Garipov;B., Khrenov;P., Klimov
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.47.4-47.4
    • /
    • 2009
  • 초소형전기기계시스템(MEMS: Micro-Electro-Mechanical Systems) 기술로 제작된 마이크로미러 어레이를 장착한 MEMS 우주망원경은 특유의 광시야각 감시, 목표 확인, 확대 및 고속 추적 기능을 가지며 고층대기에서의 초대형 방전현상과 같이 넓은 영역에서 드물게 임의로 일어나는 섬광현상을 관측하기에 최적이다. 러시아 과학위성 Tatiana-2의 주 탑재체로 선정된 극소형 MEMS 우주망원경 MTEL(MEMS Telescope for Extreme Lightning)은 광시야각 감시와 목표 확인을 위한 트리거망원경, 목표 확대와 고속추적을 위한 확대망원경 및 섬광현상의 분광측정을 위한 분광계로 구성되어 있다. 1년간의 개발 및 성능 검증 후 MTEL은 위성탑재를 위한 모든 우주인증 시험을 성공적으로 마쳤다. 현재 MTEL은 Tatiana-2 위성에 탑재되어 있으며, 9월 18일에 우주로 발사되어 1-3년간 800km 궤도를 비행하며 지구 대기에서 발생하는 섬광현상을 관측할 예정이다. 이 발표에서는 MTEL 탑재체의 설계, 제작, 성능 측정 및 calibration 결과를 보고하고, 위성탑재를 위한 진동 및 충격, 열, 진공 및 전자기파 적합성 등의 우주인증 시험 결과 또한 보고한다. 또한 발사 후 과학위성 및 MTEL의 이 발표 때까지의 우주에서의 상황을 보고한다.

  • PDF

Pilot Study on the Statistical Characteristics of a Railroad Weather-Related Accidents and Incidents in Korea (철도기상사고의 통계적 특성)

  • Park, Jong-Kil;Jung, Woo-Sik;Lee, Man-Ki;Kim, Hi-Man;Lee, Jae-Su
    • Journal of Environmental Science International
    • /
    • v.19 no.7
    • /
    • pp.917-929
    • /
    • 2010
  • This paper aims to find out the statistical characteristics of the weather related railroad accidents and incidents. Data from Korea Railroad Operation Information System(KROIS) and Korea Railroad Accidents reports during 1996-2008 were used to investigate the occurrence frequency of railroad accidents and operation obstacles and their association with weather phenomena. The results are as follows; The occurrence frequency of railroad accidents and operation obstacles decrease gradually, and most of railroad accidents is a railroad traffic accidents. The amount of damages by a railroad weather-related accidents is higher than those of the railroad accidents and operation obstacles. It was also found that weather events influencing the railroad weather-related accidents and incidents are rainfall, snowfall, lightning, winds. And they caused a railroad weather-related accidents and incidents, such as railway obstruction, signal failure, and power supply failure. Therefore we need research about threshold review and a quantitative and qualitative analysis of a railroad weather-related accidents and incidents according to climate change.

Dielectric Characteristics of N2 Gas under Impulse Voltage in a Quasi-Uniform Electric Field (준평등전계에서 임펄스전압에 대한 N2가스의 절연파괴특성)

  • Lee, Bok-Hee;Kim, Dong-Kyu;Li, Feng
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.126-132
    • /
    • 2010
  • This paper presents dielectric characteristics of $N_2$ gas under impulse voltages in a quasi-uniform electric field gap. The experiments were carried out at the test gap applied by the 1.2/50[${\mu}s$] lightning impulse voltage, 180/2500[${\mu}s$] switching impulse voltage, 500[ns]/1[MHz] very fast transient overvoltage(VFTO). The gap separation of sphere-to-plane electrodes was 14[mm] and the electric field utilization factor was about 71.2[%]. The gas pressure ranges from 0.2 to 0.6[MPa]. As a result, the electrical breakdowns are occurred by streamer discharge. Breakdown voltages are linearly increased with the gas pressure and the highest breakdown voltage is appeared under the VFTOs having fast rising time. Breakdown voltages under the positive impulse voltages were higher than those under the negative ones, and also the time to breakdown in the positive polarity is longer than that in the negative polarity.

A Study on the Improvement of Technical Regulation for Overvoltage Performance of Telecommunication Protector in Customer Premises (구내 통신용 보호기의 과전압 제한 성능 기준 개선 연구)

  • Ko, Hong-nam;Choi, Mun-Hwan;Cho, Pyung-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.823-826
    • /
    • 2013
  • Subscriber Protector is installed in a point of connection between main wire and in-plant cable to protect telecommunication facilities and service users from overvoltage or overcurrent due to the lightning or induction. In Korea, there are regulations for obligation of installation and performance criteria of protectors, but these regulations in force can not cope with diversification of services because it stands on the basis of PSTN service only. In earlier paper, we suggested the improvement way of technical regulation for subscriber protector in customer premises. and in this paper, we propose revised criteria for overvoltage performance of protector in customer premises, and make feasibility of revised criteria through inspection tests.

  • PDF

Module Design and Performance Evaluation of Surge Arrester for Loading In Railway Rolling Stock (전철 탑재형 피뢰기의 모듈설계 및 성능평가기술)

  • Cho, H.G.;Kim, S.S.;Han, S.W.;Lee, U.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2038-2040
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and subway are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrestor and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise. etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF

An Investigation on Surface Flashover Characteristics of FRP in Several Insulation Gases for the Spacer of Cryogenic Bushing

  • Hwang, Jae-Sang;Shin, Woo-Ju;Seong, Jae-Kyu;Lee, Jong-Geon;Lee, Bang-Wook
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.4
    • /
    • pp.20-23
    • /
    • 2012
  • Superconducting equipment has been actively investigated for securing the environment and energy technology (ET) in various parts of the world. Despite these movements, a high voltage cryogenic bushing, which plays an important role of interconnection between the electric power systems and superconducting devices, has not been fully developed due to severe insulation requirements. A gas insulated cryogenic bushing has been investigated as one of our projects since 2010. As a basic step to obtain the design parameters for cryogenic bushing, we focused on the surface flashover characteristics of glass fiber reinforced plastic (FRP) in several insulation gases. For the surface flashover tests, several insulation gases including $SF_6$, $CF_4$ and $N_2$ gas were prepared. Various length of FRP specimens were fabricated in order to obtain the fundamental data for creepage distance of FRP. The first specimen group was from 2 mm to 10 mm with 2 mm intervals and the second specimen group was from 20 mm to 100 mm with 20 mm intervals. And the gas pressure was varied from 1 bar to 4 bar. An AC overvoltage test and a lightning impulse test were performed. Then the experimental results of surface flashover were obtained and analyzed. Based on these results, it would be possible to design the optimum creepage distance of FRP in a cryogenic bushing.

Surge Protection Method of the Underground Distribution System in Korea (국내 지중배전시스템의 서어지 보호방안)

  • Lee, Jae-Bong;Jung, Yeon-Ha;Park, Chul-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.84-88
    • /
    • 2008
  • This paper deals with the part of the surge protection method of the underground distribution system in Korea using arrestors by simulating with ATP-EMTP(Electro-Magnetic Transient Program) based on the "A Study on the Surge Propagation Property of Underground Distribution Cables by Field Tests" which was published in 2007. Although domestic underground distribution system is protected by arrester which installed at a riser pole, we need to additional protection method because lightning surge can be doubled and affect underground distribution facilities when it is injected into the mixed distribution line of overhead and underground through a riser pole. In this paper, it is proposed that scout method that arresters are attached to the sides of a riser pole is better than developing of a elbow arrester on a viewpoint of economics and maintenance, because of the situation of the domestic underground distribution system.