• Title/Summary/Keyword: lighting design

Search Result 1,063, Processing Time 0.023 seconds

An Development of Landscape Lighting Power Control System with Solar Cell Generator Equipment for Energy Saving (에너지절감을 위한 태양광발전설비 연계형 경관조명 전력제어시스템의 개발)

  • Kim, Dong-Wan;Park, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.364-371
    • /
    • 2010
  • In this paper, we propose the landscape lighting power control system with solar sell generator equipment for energy saving, and also which is included the landscape lighting power transformation device. The power transformation device can check inverse current in the power of the solar cell module and control the power of the battery. And we present the design of landscape lighting power control system. The power control system uses microprocessor with charging system and power transformation device. And also it can control the power of loads under consideration intensity of illumination. The landscape lighting loads are composed of LED(Lighting Emitting Diode) and HID(High Intensity Discharge)lamps. To evaluate property, we installed the solar cell array which generate three kilo watt power. Experimental results show that the proposed system can have stability and energy saving on the mixed configuration of electric loads with DC and AC lamps.

Study on Simulation Design of Light Emitting Diode Luminaires for 100 W Safety Street Lighting

  • Shin, Ik-Tae;Lee, Se-Il;Yang, Jong-Kyoung;Park, Dae-Hee;Lee, Dong-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.3
    • /
    • pp.138-144
    • /
    • 2010
  • Optical analysis is necessary to optimize light emitting diode (LED) safety street lighting. In this study, optical analysis was conducted for 100 W LED safety street lighting. Experimental research on such a single LED was the first undertaken. Simulation modeling based on the optical properties of the single LED has compared between average road illuminances and has them analyzed with Korean Industrial Standards for LED safety street lighting (KS C7658:2009). The simulation results demonstrated that the illumination performance (average road illuminance) was 75.3 lx at a height of 4 m and an area of $32\;m^2$, 45.25 lx at a height of 5 m and an area of $72\;m^2$, and 30.05 lx at a height of 6 m and an area of $128\;m^2$. 100 W safety street lighting (model CE180-ST-OS) designed by simulation was also compared between product and 100 W simulation modeling, and error rates averaged 5.6%. The 100 W LED safety street lighting base designed in simulation modeling was proven by comparison experiments. Through the simulations and the corresponding analysis, it was found that the tested 100 W LED safety street lamp had reasonable performance. The design method for LED safety street lamps has been summarized based on the optical analysis.

Design and Implementation of LED Lighting System with Adjustable Brightness and Color Capability (색상 및 밝기 조절이 가능한 LED 조명 기구의 설계 및 구현)

  • Kwak, Seong-Woo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.5
    • /
    • pp.579-586
    • /
    • 2015
  • In this paper, we design and implement a lighting system which has a capability of adjusting brightness and colors of LED module. The lighting systems is consisted of RGB and white LEDs controlled by a micro-processor. All colors in nature can be synthesized in our lighting system by controlling brightness of 4 color LEDs individually. The current flowing to LED is limited to a maximum set value to extend the LED life time using PWM current control. The control module also includes the function that it can save and load brightness and color data set by the user. The implemented lighting system passed the electromagnetic compatibility(EMC) test such that it can be used as a commercial product.

Residents Attitude Survey of Landscape Lighting of Dongdaegu in Daegu (대구시 동대구로의 경관조명에 관한 주민의식 조사 - 동대구로 경관조명의 디자인 특성에 관한 연구 -)

  • An, Ok-Hee;Lee, In-Hyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • In this study, students in twenties of fill people who has been living in Daegu were surveyed to landscape lighting on Dongdaeguro to investigate the awareness of residents. As a result, the factor that most influenced to the night landscape lighting is the 69.2[%] to the highest and the image of Daegu city is education and culture were the highest. Need to focus on the Daegu landscape design is 'nature harmony' is the highest. The greatest and the poorest effect in the night scenery is 'lighting' and lighting conditions and brightness were negative.

The research for colorific lighting initiate movie spatiality (색조명이 창조하는 영상적공간성에 관한 연구)

  • Yuan, Fangchi;Kim, Dong Hyun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.988-992
    • /
    • 2009
  • The combination of colors and lighting is one of the most significant techniques to display the spatial artistic effects in movies. The aesthetic perception created by colors and lighting is extremely expressive and infectious. It has become an essential technique to render the atmosphere for the scenes in current movies. Through researching the principles of spatial lighting and the stage lighting colors' application, while comparing and analyzing the movies directed by Kar-wai Wong and Baz Luhrmann, this thesis mainly aims at further clarifying the application technique of colors and lighting in the space of movies.

  • PDF

A study on the design and performance of a stand-alone photovoltaic lighting system (독립형 태양광 조명 시스템의 설계 및 성능 평가 연구)

  • Kwon, Oh-Sang;Seo, Yu-Jin;Huh, Chang-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.1-10
    • /
    • 2004
  • In view of global environmental problems and resource exhaustion, we must develop new energy resources that are abundant and provide substitutes for fossil fuels. Renewable energies, such as solar, are ideal because they are clean, inexhaustible, and available everywhere in the world. Photovoltaic(PV) system, in general, are operated as a stand-alone, grid-tied, or hybrid system. Many of the stand-alone PV systems are installed. Although the pre-installation cost of PV system is high, it poorly has been operated due to the absence of optimal management standards. Therefore a study on the performance of PV system is important for the system design and maintenance. In this paper a photovoltaic lighting system was resigned according to load consumption. Then a PV lighting system which used electrodeless lamp as a load was installed. In order to investigate the system operating characteristics we've added a monitoring system to the PV lighting system. The monitoring system using the LabVIEW program regularly checks the operation of the PV lighting system and records the system data. According to the system data, the stability and availability of the PV lighting system were evaluated.

A Study on the Calculation of Maintenance Factor(MF) of Tunnel Lighting in Expressway Considering the Actual Installation and Maintenance Conditions (실제 설치 및 유지보수 조건을 고려한 고속도로 터널조명 보수율 산정 연구)

  • Lee, Min-Wook;Park, Kwang-Yong;Kim, Pil-Young;Park, Yong-Jin;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.7-15
    • /
    • 2013
  • In lighting design, the calculation of maintenance factor is performed by calculation considering light source, characteristics of luminaire and environmental factors. The method to calculate the current maintenance factor applied to tunnel lighting design takes into consideration only pollution factors in tunnels. In addition, the calculation method should be change in response to changes of tunnel conditions and used light sources. In this study, the calculated factor of the maintenance factor in tunnel is determine by four calculation factors generally applied to the calculation of maintenance factor. This study examined the method of calculating the maintenance factor of tunnel lighting that can be applied according to the installation conditions in designing tunnel lighting by applying the actual installation data of luminaire.

A Study on the Characteristics of Each Type of LED Digital Landscape Lighting in Expressway Tunnel (고속도로 터널 내 LED Digital 경관조명 디자인의 유형별 특징 비교 연구)

  • Hwang, Ye-Jin
    • Journal of Digital Convergence
    • /
    • v.19 no.12
    • /
    • pp.457-462
    • /
    • 2021
  • As South Korea is a mountainous topography, installation of tunnel is essential for construction of expressway in straight lines. According to "2019 Road Bridge and Tunnel Status Report", there are 2,682 tunnels in Korea with total length of 2,077km. Tunnels take up 1.9% of total road length and the number of tunnel increased by 94% with 1,300 newly constructed tunnels over the 10 years. According to domestic and foreign researches, a long tunnel over 1km in expressway has dark lightings and monotonous wall design which decrease driver's concentration and make the driver feel bored. This leads to feeling fatigue and drowsiness more easily. In response, Korea Expressway Corporation installed design lighting that increases attentiveness on 10 tunnels with total length over 3km by 2020. To reduce the risks of accident that may happen inside the tunnel, this study conducted a comparative analysis on characteristics of each type of LED landscape lighting installed inside the expressway tunnel. The study aimed on providing the basic material for effective installation of LED landscape lighting for securing driving stability, reducing fatigue, and lowering the risk of drowsiness.

Analysis of User Preference about the Color Rendering Index, Correlated Color Temperature and Illuminance of LED Lighting in Merchandising Spaces (상업공간에서의 사용자 선호 LED 조명 연색지수와 상관색온도, 조도의 분석)

  • Lee, Su-Jung;Yoon, Hea-Kyung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.1
    • /
    • pp.99-106
    • /
    • 2019
  • This study aims to recommend the proper Color rendering index (CRI), the Correlated Color Temperature (CCT), and illuminance levels of Light-Emitting Diode (LED) lighting based on the analysis of the criteria of the current CRI, the CCT, and illuminance levels in merchandising spaces with LED lighting conditions. It would be a basic material to apply in line with user preference for LED merchandising lighting. To this end, it examines relevant literature review on the experiments designed to test whether lighting characteristics affect brightness perception, color appearance, and pleasantness. Highly saturated colors appear brighter than low saturated colors. Two lighting applications - grocery and clothing shop - were created in elaborating the effect of LED lighting characteristics of CRI on color appearance and the CCT and illuminance on pleasantness. The findings show that the criteria of CIE Ra<80 are appropriate to provide better color appearance of illuminated products in terms of LED lighting that can enhance color saturation, particularly for the red color. Furthermore, 2700 K and less than 500 lux for grocery, 4000 K and more than 500 lux for clothing shop are found to be the proper the CCT and illuminance levels respectively to bring better preference under LED lighting.

The Comparison of the Economical Efficiency of Light Sources for a Tunnel Lighting (터널조명용 광원의 경제성 비교)

  • Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.32-42
    • /
    • 2011
  • In this paper to compare the economical efficiency of light sources for a tunnel lighting, we define a model tunnel and design tunnel lighting. And to examine economical efficiency of various tunnel lightings we compare the lighting expenses of tunnels. The results shows high pressure sodium lamps are more economical than fluorescent lamps.