• 제목/요약/키워드: light-frame

검색결과 430건 처리시간 0.033초

소규모 기업에 있어서 지식소싱 전략이 기업성과에 미치는 영향 고찰 (An Examination of Knowledge Sourcing Strategies Effects on Corporate Performance in Small Enterprises)

  • 최병구
    • Asia pacific journal of information systems
    • /
    • 제18권4호
    • /
    • pp.57-81
    • /
    • 2008
  • Knowledge is an essential strategic weapon for sustaining competitive advantage and is the key determinant for organizational growth. When knowledge is shared and disseminated throughout the organization, it increases an organization's value by providing the ability to respond to new and unusual situations. The growing importance of knowledge as a critical resource has forced executives to pay attention to their organizational knowledge. Organizations are increasingly undertaking knowledge management initiatives and making significant investments. Knowledge sourcing is considered as the first important step in effective knowledge management. Most firms continue to make an effort to realize the benefits of knowledge management by using various knowledge sources effectively. Appropriate knowledge sourcing strategies enable organizations to create, acquire, and access knowledge in a timely manner by reducing search and transfer costs, which result in better firm performance. In response, the knowledge management literature has devoted substantial attention to the analysis of knowledge sourcing strategies. Many studies have categorized knowledge sourcing strategies into intemal- and external-oriented. Internal-oriented sourcing strategy attempts to increase firm performance by integrating knowledge within the boundary of the firm. On the contrary, external-oriented strategy attempts to bring knowledge in from outside sources via either acquisition or imitation, and then to transfer that knowledge across to the organization. However, the extant literature on knowledge sourcing strategies focuses primarily on large organizations. Although many studies have clearly highlighted major differences between large and small firms and the need to adopt different strategies for different firm sizes, scant attention has been given to analyzing how knowledge sourcing strategies affect firm performance in small firms and what are the differences between small and large firms in the patterns of knowledge sourcing strategies adoption. This study attempts to advance the current literature by examining the impact of knowledge sourcing strategies on small firm performance from a holistic perspective. By drawing on knowledge based theory from organization science and complementarity theory from the economics literature, this paper is motivated by the following questions: (1) what are the adoption patterns of different knowledge sourcing strategies in small firms (i,e., what sourcing strategies should be adopted and which sourcing strategies work well together in small firms)?; and (2) what are the performance implications of these adoption patterns? In order to answer the questions, this study developed three hypotheses. First hypothesis based on knowledge based theory is that internal-oriented knowledge sourcing is positively associated with small firm performance. Second hypothesis developed on the basis of knowledge based theory is that external-oriented knowledge sourcing is positively associated with small firm performance. The third one based on complementarity theory is that pursuing both internal- and external-oriented knowledge sourcing simultaneously is negatively or less positively associated with small firm performance. As a sampling frame, 700 firms were identified from the Annual Corporation Report in Korea. Survey questionnaires were mailed to owners or executives who were most erudite about the firm s knowledge sourcing strategies and performance. A total of 188 companies replied, yielding a response rate of 26.8%. Due to incomplete data, 12 responses were eliminated, leaving 176 responses for the final analysis. Since all independent variables were measured using continuous variables, supermodularity function was used to test the hypotheses based on the cross partial derivative of payoff function. The results indicated no significant impact of internal-oriented sourcing strategies while positive impact of external-oriented sourcing strategy on small firm performance. This intriguing result could be explained on the basis of various resource and capital constraints of small firms. Small firms typically have restricted financial and human resources. They do not have enough assets to always develop knowledge internally. Another possible explanation is competency traps or core rigidities. Building up a knowledge base based on internal knowledge creates core competences, but at the same time, excessive internal focused knowledge exploration leads to behaviors blind to other knowledge. Interestingly, this study found that Internal- and external-oriented knowledge sourcing strategies had a substitutive relationship, which was inconsistent with previous studies that suggested complementary relationship between them. This result might be explained using organizational identification theory. Internal organizational members may perceive external knowledge as a threat, and tend to ignore knowledge from external sources because they prefer to maintain their own knowledge, legitimacy, and homogeneous attitudes. Therefore, integrating knowledge from internal and external sources might not be effective, resulting in failure of improvements of firm performance. Another possible explanation is small firms resource and capital constraints and lack of management expertise and absorptive capacity. Although the integration of different knowledge sources is critical, high levels of knowledge sourcing in many areas are quite expensive and so are often unrealistic for small enterprises. This study provides several implications for research as well as practice. First this study extends the existing knowledge by examining the substitutability (and complementarity) of knowledge sourcing strategies. Most prior studies have tended to investigate the independent effects of these strategies on performance without considering their combined impacts. Furthermore, this study tests complementarity based on the productivity approach that has been considered as a definitive test method for complementarity. Second, this study sheds new light on knowledge management research by identifying the relationship between knowledge sourcing strategies and small firm performance. Most current literature has insisted complementary relationship between knowledge sourcing strategies on the basis of data from large firms. Contrary to the conventional wisdom, this study identifies substitutive relationship between knowledge sourcing strategies using data from small firms. Third, implications for practice highlight that managers of small firms should focus on knowledge sourcing from external-oriented strategies. Moreover, adoption of both sourcing strategies simultaneousiy impedes small firm performance.

CEM BIO Film 피복시설의 환경특성과 풋고추 생육 (Greenhouse Environment and Growth of Green Pepper (Capsicum annuum L.) in Greenhouse Covered with CEM BIO Film)

  • 전희;김경제;권영삼;김현환;이시영
    • 생물환경조절학회지
    • /
    • 제9권3호
    • /
    • pp.161-165
    • /
    • 2000
  • CEM BIO P.E.필름으로 피복된 시설에서 300~1,100nm 사이의 분광투과율은 일반 P.E. 필름으로 피복된 시설보다 높았다. 전반적으로 시설내 광투과율은 이중피복, 골조, 기타시설물 때문에 노지에 비하여 절반 수준을 나타냈다. 순복사량은 CEM BIO P.E. 필름 피복시설이 5,424.5W.m$^{-2}$ 로서 일반 P.E.필름 피복시설보다 2.9% 낮았고, 광합성유효복사 투과율은 CEM BIO P.E.필름 피복시설이 3,861.2W.n$^{-2}$ 로서 일반 P.E. 필름 피복시설보다 3.8% 높았으며, 무가온기의 적산최저온도는 CEM BIO P.E. 필름 피복시설이 일반 P.E. 필름 피복시설보다 1일 평균 0.35$^{\circ}C$ 높았다. 정식후 30일의 풋고추 생육은 CEM BIO P.E. 필름 피복시설에서 초장, 경경, 엽면적, 생체중, 건물중 및 군락생산구조가 우수하였고, 과실은 과중이 11.28g으로 일반 P.E. 필름 피복시설 보다 1.25g 무거웠으며, 상품율은 2.7% 높았다. 1997년 11월 19일부터 1998년 3월 3일 사이의 수량은 CEM BIO P.E. 필름피복시설에서 7.4% 많았으나 전체적인 수량은 차이를 보이지 않았다.

  • PDF

전산화단층촬영 주사시간(Scan Time)이 폐종양운동의 재현성에 미치는 영향 분석 (Impact of the Planning CT Scan Time on the Reflection of the Lung Tumor Motion)

  • 김수산;하성환;최은경;이병용
    • Radiation Oncology Journal
    • /
    • 제22권1호
    • /
    • pp.55-63
    • /
    • 2004
  • 목적 : 방사선치료계획용 전산화단층활영(computerized tomography, 이하 CT) 시 주사시간이 종양부피의 재현성에 미치는 영향을 살펴보고자 하였다. 대상 및 방법 : 인공호흡기의 환기작용에 의해 세로방향의 왕복 운동을 하는 N자형 모형을 제작하였고, 호흡주기를 T로 하였을 때 주사시간을 상대적으로 각각 0.33, 0.50, 0.67, 0.75, 1.00, 1.33, 그리고 1.53 T로 설정하고 CT촬영을 시행하였다. 또한 2002년 3월 19일부터 2002년 5월 21일까지 서울아산병원 방사선종양학과에서 정위방사선수술(stereotactic radiosurgery)을 시행받은 비소세포성 폐암 환자 3명을 대상으로, 주사시간이 빠른 CT (LightSpeed, GE Medical Systems, 주사시간 0.8초)와 느린 CT (IQ Premier, Picker, 주사시간 2.0초)를 각각 $1\~4$회 시행하였다. 각각의 slice에서, N자형 모형의 왕복 운동이 CT 영상에 반영된 좌우방향 선분의 길이를 측정하여 치료계획용 CT 촬영이 모형의 움직임을 반영하는 정도를 측정하였다. 환자를 대상으로 한 연구에서는 정위적 체부 고정틀을 이용하여, 빠른 CT 및 느린 CT의 종양을 하나의 CT 영상조합에서 재구성하여 종양의 체적과 장경을 측정하여 비교하였다. 결과 : 모형실험에서 주사시간에 비례하여, 세로방향 운동을 CT 촬영에서 반영하는 정도는 증가하였으며 1.00 T 이상에서는 일정한 양상을 보였다 주사시간 1.00 T 이상에서 얻어진 결과를 기준으로, 1.00 T 미만의 주사시간을 가지는 CT촬영에서 모형운동을 반영하지 못하는 비율이 각각 $0.33\;T:\;30\%,\;0.50\;T:\;27\%,\;0.67\;T:\;20\%,\;0.75\;T:\;7.0\%$로 측정되었다. 또한 투시검사로 측정한 종양의 세로 방향 움직임이 각각 3 mm, 5 mm, 10 mm이었던 각각의 환자에서 느린 CT에서 얻어진 종양의 세로방향 장경이 빠른 CT에 비해 $5.3\%\;17\%,\;23\%$ 증가하였다. 결론 : 주사시간을 환자의 호흡주기 이상으로 하는 경우 setup margin만을 고려하여 계획용표적체적(planning target volume, PTV)을 정의할 수 있으므로 정상 폐조직에 조사되는 방사선량을 줄여 치료효율을 향상시킬 수 있을 것으로 생각된다.

디지털 애니메이션 체현에 관한 매체미학적 고찰 (Embodiment in Digital Animation in Relation to Media Aesthetics)

  • 전혜현
    • 만화애니메이션 연구
    • /
    • 통권41호
    • /
    • pp.533-552
    • /
    • 2015
  • 가상현실 기반의 디지털 애니메이션에서는 이미지와 이미지 수용자 간의 긴밀한 상호작용을 촉발시키기 위해 모니터나 스크린 중심의 고정된 물리적 공간을 탈피하는 환경이 모색된다. 그 과정에서 인터페이스를 매개로 수용자와 이미지 사이의 경계가 사라지거나 혹은 융합되는 양상이 벌어지며, 이는 특히 수용자의 신체와 이미지가 직접 연계되는 바이오-피드백 장치들이 결부될 경우에 더욱 강화된다. 이제 이미지 수용자는 이미지 공간 내부에서 자신과 이미지 사이의 상호침투적인 상호작용을 경험하는 가운데 가상의 이미지 세계, 즉 가상현실에 깊이 연루된다. 따라서 이미지와 거리를 두고 이미지를 바라보는 구조, 그리고 그에 따라 이미지와 수용자가 분리되어 수용자가 이미지 해석에 주력하게 되는 기존의 방식과 달리, 이미지와 수용자가 유기적으로 결합하는 이미지 공간 내부에서의 수용 방식에 대해 접근할 필요가 있다. 이에 본 논문은 기술 장치에 의해 매개되는 애니메이션 이미지와 수용자의 통합적인 양상을 매체미학적 관점에서 고찰하였다. 이성적 관념 중심의 전통미학과 달리, 매체미학은 기술 매체의 매개와 그에 따른 이미지 수용자의 감각적 지각작용에 주목한다는 점에서 가상현실 기반의 애니메이션 수용 과정을 분석하는 데에 매우 유효하다. 이미지와 수용자의 상호작용을 도모하는 가상현실의 애니메이션에서는 수용자가 이미지 속에서 자신의 신체 전체를 개입시켜 온몸으로 몰입하는 체현적 몰입이 발생하게 된다. 이 체현적 몰입은 이미지와 수용자를 한데 융합하는 인터페이스에 의해 매개되는 현상으로, 그로 인해 이미지를 지각하는 매순간마다 이미지 체현은 달라질 수밖에 없다. 따라서 이는 애니메이션에 대한 해석이 아닌, 애니메이션의 체현을 통해 그 의미를 수용자가 직접 구성해나간다는 점에서, 체현적 몰입자로서 수용자 중심의 새로운 애니메이션 구조가 열리는 것으로 파악할 수 있다. 즉 애니메이션에 대한 매체미학적 고찰은 애니메이션을 감상이나 해석 차원으로부터 나아가 감각적 지각에 의한 참여의 차원으로 접근하는 것이다.

소아청소년정신과영역의 새로운 항우울제 (NEW ANTIDEPRESSANTS IN CHILD AND ADOLESCENT PSYCHIATRY)

  • 이수정
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • 제14권1호
    • /
    • pp.12-25
    • /
    • 2003
  • 새로운 항우울제가 다량 개발되어 임상에 도입되면서 항우울제의 약리 작용에 대한 이해도 넓어졌다. 그에 따라 얻어진 새로운 정보와 이론을 소아청소년기 우울증 치료에 반영할 필요가 있다. 소아청소년기 최신지견에 따라 합리적인 우울증 치료 지침 마련을 위하여 고려하여야 할 주요 사항들과 새로운 항우울제의 특징들을 살펴보고자 하였다. 전자문헌 데이터베이스 검색 도구를 사용하여'new', 'antidepressant', 'children'의 검색어로 얻어진 97개 고찰 문헌 가운데 특히 치료 지침과 새로운 항우울제의 정신약리작용에 관한 것을 선별하여 중점적으로 고찰하였다. 아울러 새로운 항우울제 각 약물에 대한 치료 효과에 대한 문헌을 추가로 선택 참고하였다. 또 약물상호 작용과 안전성에 관하여 미국 식품보건국과 보건후생부의 공식사이트에서 제공되는 문헌을 참고하였다. 1) 우울 장애의 임상 경과, 치료 기간, 및 치료 효과는 성인기 치료 지침에서 제시된 바를 채택한 경우가 많았다. 2) 소아청소년기 우울증에 대한 항우울제의 효과에 대한 연구 결과는 TCA가 효과와 부작용에서 SSRI보다 뒤져서 소아청소년 우울장애의 일차 치료제로 권장 된다. 3) 새로운 항우울제는 아직 소아청소년에게 치료 경험과 임상 연구 결과가 부족하다. 4) SSRI와 새로운 항우울제들은 두 개 이상을 병용할 때 약동학적 및 약력학적인 상호작용이 있을 수 있다. 5) 소아청소년기 항우울제의 임상적 효과가 성인기와 다른 것은 발달적 측면에서 설명할 수 있겠으나 직접적인 증거가 좀더 쌓일 필요가 있다. 소아청소년기 우울증의 약물 치료 지침은 임상 연구 소견과 임상적 경험을 종합하여 세울 수 있다. 그러나 약물 치료 지침은 임상가가 합리적인 판단을 내릴 수 있도록 하는 참고 자료이며 그 목적을 다하기 위하여 새로운 연구 결과가 있을 때 마다 새로 개정 되어야 할 것이다. 중 외톨이-왕따에 해당되는 청소년의 어머니는 비외톨이 청소년의 어머니보다 자녀들의 사고 문제 및 우울/불안 등의 정서적 문제를 더 높게 평가하였다. 그러나, 자녀들에 대한 양육 태도에 대해서는 차이를 두지 않는 것으로 보인다. 향후 보다 많은 환자들을 대상으로 한 추가 연구가 필요할 것이다. 강압적인 양육행동을 변화시키기 위해서는 주의력결핍과잉행동장애 아동 부모의 양육 스트레스, 아동에 대한 역기능적 사고 및 양육 효능감을 다루어야 할 뿐 아니라, 부모의 우울감을 치료 시 고려해야 할 것이다.순차처리항목과 계산능력에서 유의하게 높았고(p<.05), KEDI-WISC를 이용한 평가에서는 ADHD- HI형은 대상수가 소수여서 비교할 수 없었으며, ADHD-C형과 ADHD-Ⅰ형 사이에 유의한 차이는 보이지 않았다. CPT, WCST, SST를 이용한 신경심리학적 실행기능의 비교에서 아형간 계량적인 차이는 있었으나 통계적으로 유의한 차이는 보이지 않았다. 결 론:결론적으로 ADHD 세 아형은 임상적으로 뚜렷한 차이를 보였지만, 실행기능상 유의한 차이를 발견할 수 없었다. 향후 보다 잘 고안 된 연구와 발달중인 아동에 적절한 신경심리 평가 도구의 개발을 통해 결과를 보완해야 할 것으로 사료된다.었으나, 주의력에서는 전두엽의 실행능력(executive function)과 관련되는 검사들에서 산소흡입이 특이한 효과를 보여준다는 것이 확인되었고, 기억능력에서는 단기기억능력 평가에서 산소흡입군이 대조군보다 유의한 효과를 보여주는 것으로 평가되었다. 이러한 연구결과는 산소흡입이 전두엽과 관련된 수행능력, 작동기억능력 향상에 도움이 될 가능성이 있음을 시사하는 결과라고 생각된다.증 1명(5%)이었다. 모든 대상 아동이 주 진단 이외의 2∼6개 이상의 다양한 공존진단을 보였다. 공존진단에는 주의력결핍-과잉운동장애, 우울병, 경계선지능 및 정신지체, 학습장애,

  • PDF

영화 <이다>에 나타난 의미적 맥락의 시각화 (A The Visualization of Semantic Context in the Film )

  • 김태규;김규남
    • 한국엔터테인먼트산업학회논문지
    • /
    • 제15권8호
    • /
    • pp.145-159
    • /
    • 2021
  • 영화 <이다>(Ida, 2013)는 서사와 인물의 심리적 동기를 모호하게 하고, 선형적 시간성을 파괴하며, 다양한 기법을 통해 디지털 이미지의 조작 가능성을 상기시키는 현대의 실험적 영화라 볼 수 있다. 인간의 주체와 자아인식 변화 과정이 사회적 트라우마와 연결된다는 점에서 다른 국가나 사회의 역사적 맥락을 대비시켜 추론할 수 있다. 영화 <이다>는 화면 밖의 공간, 부재하는 공간, 여백과 프레임 안에 내포된 의미를 중심으로, 보이는 공간의 정보와 화면 밖 공간과의 정보를 나눔으로써 관객으로 하여금 제시되지 않은 정보에 대해서 추론하게 하는 능동적 인지과정을 불러일으키고 있다. 시대적 배경을 자세히 기술하지 않으면서도 역사적 의미를 시각화했고, 초월적 존재인 신과 한계적 존재인 인간 사이의 갈등과 고민의 문제를 인간과 인간의 갈등 구조 안에서 표현하고자 했다. 아울러 상실과 부재의 슬픔을 공간적 미학으로 풀어내고자 시도했으며 인물의 대비와 대조, 빛과 어둠의 대비를 통해 상황의 전개를 나타냈다. 본고에서는 영화 <이다>가 함축하고 있는 개인(인물)의 이야기와 사회, 역사적 배경과 종교적 영역을 아우르는 해석을 시도하고, 의미적 맥락의 시각화를 다루고자 한다. 또한 정체성과 역사적 사건의 재구성, 종교적 가치를 다룬 영화 <이다>의 시퀀스 장면 분석을 통해 그 의미와 특징을 살펴보고, 영화가 추구한 총체적 의미를 구체적으로 분석할 것이다. 이는 영화 <이다>가 내포하고 있는 트라우마의 재현과 해석 차원으로 개인과 지역, 국가적 트라우마를 안고 있는 문제를 다루었다는 측면에서 한국적 상황에 주는 함의를 고려해 볼 수 있다. 나아가 과하게 표현하지 않으면서도 인간과 사회적 성장, 고민을 잔잔하게 다루는 모습을 통해 새로운 영상기술과 독창적 시각화 기법의 영화를 창조하려는 흐름에 또 다른 영감을 주는 연구가 될 것이다.

EU의 우주행동강령의 의미와 평가 (EU's Space Code of Conduct: Right Step Forward)

  • 박원화
    • 항공우주정책ㆍ법학회지
    • /
    • 제27권2호
    • /
    • pp.211-241
    • /
    • 2012
  • 유럽연합(European Union: EU)이 2012년 6월 유엔의 우주의평화적이용위원회(COPUOS) 제 55차 회기에서 공식 제기한 우주활동의 국제 행동규범안(Draft International Code of Conduct for Outer Space Activities)은 그간 우주에서의 국가 활동 규범에 대한 미비한 요소들을 제시한 내용으로서 국제사회의 관심을 끌기에 충분한 내용이다. 현재 우주에서의 미비한 질서는 군비경쟁 금지, 우주쓰레기 경감 등을 통한 우주의 안전과 안보를 위한 지침, 그리고 우주활동의 정보를 참여 국가 간 교환하는 것이라고 할 수 있는 바, EU의 상기 제안은 여사한 문제들에 대한 행동 강령을 정한 것으로서 주목되는 내용이다. 2008년 말부터 시작된 EU의 제안 활동은 그간 일부 우주활동 국가들, 특히 미국과의 비공식 접촉을 통하여 접촉대상국들의 의견도 반영한 가운데 2013년 채택을 목표로 하는 자발적 이행 규범으로서 강제력을 가지고 있지는 않지만 미국은 우주에서의 군축 관련 규범 제정의 필요성에 탄력을 제공하는 계기가 될 가능성에 우려하는 가운데 현재는 방관하고 있는 입장으로 보인다. 이러한 미국의 입장은 우주에서 전략적 우위를 점하고 있다는 자국의 이익이 군축에 관한 규범의 제정으로 손상될 수 있다는 판단을 근거로 하고 있다. 이에 따라 미국은 유엔 총회에서 우주에서의 군비경쟁 방지(PAROS)에 관한 결의에 반대하고 군축회의(Conference on Disarmament: CD)에서 오랫동안 논의되어 왔던 우주에서의 군축을 촉구하는 논의의 장을 마련하는 것에 반대하여 왔다. 중국과 러시아는 2008년 우주에서의 군축에 관한 PPWT (Treaty on Prevention of the Placement of Weapons in Outer Space and of the Threat or Use of Force against Outer Space Objects)채택을 제안하였는 바, EU의 제안은 자신들이 제안한 PPWT의 추력을 저상시키는 내용이 되기 때문에 불편한 심정으로서 역시 소극적인 입장이다. 한편, 미국이 상기 입장의 연장선 상에서 PPWT에 반대 입장을 취하는 것은 이해하기 어렵지 않다. EU의 행동규범안은 주요 우주대국의 군사전략적 측면에서의 이해관계 때문에 그 장래가 명확치 않으나 우주쓰레기의 경감을 위하여 노력하고 우주활동의 정보를 상호교환하면서 우주에서의 안전과 안보를 보장을 통하여 가능한 우주의 평화적 이용과 탐사라는 기본 명제를 극대화 시키는 효과를 가져오는 것으로서 매우 바람직한 조치로 간주된다. 단, 동 규범안은 참여 국가들간의 협조와 연락업무를 수행하기 위하여 상설기구를 설치하도록 되어있지만 이는 기존 조직인 유엔외기권사무소(UN Office for Outer Space Affairs)가 담당하도록 할 경우 효율과 경제를 도모할 수 있을 것이다. 동 규범안에 대한 추후 구체 협상 시 여사한 내용도 논의될 것으로 보지만 EU의 우주활동의 안전과 안보에 관한 조치는 환경문제에서와 같이 국제사회를 이끌어가는 또 하나의 의미있는 기여로 평가받아야 한다.

  • PDF

퇴계(退溪)의 천관(天觀) 연구(硏究) (A Study of Perspective on Cheon Gwan(天觀) of Toegye)

  • 황상희
    • 동양고전연구
    • /
    • 제56호
    • /
    • pp.147-170
    • /
    • 2014
  • 천(天)의 개념을 살펴보자면 송대(宋代)이전은 종교적(상제(上帝)) 천(天)이라면 송대(宋代)이후는 합리적(천(天)理) 천(天)이다. 주자는 종교성을 잃어버렸고 퇴계는 회복했다. 이 논문은 퇴계와 주자가 말하는 천(天)의 속성이 다르다는 것을 기반으로 리(理)의 종교성까지 밝히는 것이 목적이다. "서명"은 '이일분수(理一分殊)'의 논리로 설명되어진다. 주자와 퇴계는 이일(理一)이란 측면에서는 사천(事天)이란 해야한다고 말하지만 분수(分殊)의 측면에서 살펴보면 주자는 천리(天理)의 이법을 따라야 한다고 하고 퇴계는 사친(事親)의 효(孝)를 행해야 한다고 한다. 이와 같이 퇴계와 주자는 천(天)의 속성 다르기 때문에 방법에 있어서도 차이가 생긴다. 이러한 차이는 리(理)의 속성에까지 영향을 미친다. 주자(朱子)는 소이연(所以然)은 리(理), 소당연(所當然)은 사(事)라고 구분해서 말한다. 퇴계(退溪)는 소당연(所當然)이야 말로 리(理)라고 말한다. 본질과 실존의 논의로 보자면 퇴계에게는 실존이 본질보다 먼저인 것이다. 리(理)라는 형이상학적 논의 속으로 실존의 문제를 이야기 할 수 있게 되었다. 퇴계(退溪)에게서 주자(朱子)와 다르게 주목되는 이론은 '이자도(理自到)'설 이다. '이자도(理自到)'는 나라는 주체가 타자에게 지극히 하면 타자가 나에게로 와서 나를 통해 발현된다는 것이다. 이 논의는 '물격(物格)'에 토를 넣는 문제에서 시작한다. 퇴계는 '물리(物理)'가 이르는 것이 아니라 '중리(衆理)'가 이르는 것이라고 말한다. 이는 '상대적 리(理)'와 '절대적 리(理)'를 명확하게 구분하기 위한 논의이다. 존재는 비존재를 존재로 한 존재이기 때문에 상대적 리(理)이지만 존재와 비존재를 뛰어 넘으면 절대적 리(理)이다. 이는 분수(分殊)의 리(理)와 이일(理一)의 리(理)에 대한 차이이다. 즉 절대적 리(理)가 나에게로 이르러 내 삶에서 드러나는 공효가 물격(物格)이다. 퇴계는 천(天)=리(理)=상제(上帝)를 동일시하는 종교적인 태도를 강하게 보이고 있다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF