• Title/Summary/Keyword: light sensitivity

Search Result 613, Processing Time 0.024 seconds

Sensitivity Improvement of the Web Patterned Si Photodiode (Web-패턴 Si 광다이오드의 감도특성 개선)

  • Jang, Ji-Geun;Lee, Sang-Yeol;Kim, Jang-Gi
    • Korean Journal of Materials Research
    • /
    • v.11 no.4
    • /
    • pp.247-250
    • /
    • 2001
  • We have fabricated and evaluated a new Si pin photodiode for red light detection with the web patterned $p^{+}$ -shallow diffused region in the light absorbing area. From the measurements of electro-optical characteristics under the bias of -5V, the junction capacitance of 4pF and the dark current of 235pA were obtained. When the 1.6㎼ optical power with peak wavelength of 670nm was incident on the device, the optical signal current of 0.48$\mu\textrm{A}$ and the responsivity of 0.30A/W were obtained. The fabricated device showed the improved sensitivity compared to the conventional circular type device and the maximum spectral response in a spectrum of 670~700nm. The web-patterned Si photodiode can be expected to have the good discrimination characteristics between digital signals in the application of red light optics.

  • PDF

Optical Analysis of Film Colored Overlay for people with Scotopic Sensitivity Syndrome (광과민성증후군자를 위한 필름 색 오버레이의 광학적 특성 분석)

  • Jang, Young-Gun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.425-433
    • /
    • 2012
  • Purpose: Basic design of virtual colored overlay, film overlay, colored lenses and colored glasses for people with Scotopic Sensitivity Syndrome. Methods: I calculated sRGB and RGB values of the overlays from measured data. I evaluated the relationship between the combinational chromaticities composed of Galaxy Tab white background and film overlays and the chromaticities of pure film overlays. Results: Implementable sRGB and RGB values of the overlays is calculated. The chromaticities of film overlays are different from them with white paper background and them with Galaxy Tab's white background, but showed a certain relationship between them. Light transmittances of Intuitive Overlay are the most (59%-79%) among them and average light reflectance of Reading Ruler is least(8%). Conclusions: The sRGB values and the RGB values are directly applicable to implement assistive tools and the light transmittances are used to calculate ${\alpha}$, transparency of virtual overlay in IT devices. It is recommended to consider the chromaticity of white color in implementing virtual colored overlay in the case which the chromaticity is considerably different to theoretical chromaticity of white color.

Recent Trends of Light-enhanced Metal Oxide Gas Sensors: Review

  • Cho, Minkyu;Park, Inkyu
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.103-109
    • /
    • 2016
  • Recent light-enhanced metal oxide gas sensors are reviewed in this article. The basic mechanisms of a light-enhanced metal oxide gas sensor are discussed. Many literatures reveal that the standalone sensitivity and the response/recovery time enhancements enabled by the exposing light are not as high as the performance enhancement provided by external heating. Therefore, both optimal amount of external heating and exposed light intensity are necessary to increase the performance of these light-enhanced gas sensors. The development of highly light sensitive materials and structures is important to lower the overall power consumptions of the sensors.

2.2 “ QVGA LTPS LCD Panel integrated with Ambient light Sensor

  • Weng, Chien-Sen;Chao, Chih-Wei;Tseng, Hung Wei;Peng, Chia-Tien;Lin, Kun-Chih;Gan, Feng-Yuan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1319-1322
    • /
    • 2007
  • Planar PIN photodiode is compatible with LTPS process, and its fabrication requires no additional manufacturing process. In this study we design the optimum dimension of PIN diodes with two nitride layers to improve the efficiency of PIN diodes. The PIN photo sensor shows very good sensitivity to ambient light illuminance.

  • PDF

Inorganic Nanoparticles for Near-infrared-II Fluorescence Imaging (근적외선-II 형광 이미징을 위한 무기 나노입자)

  • Park, Yong Il
    • Applied Chemistry for Engineering
    • /
    • v.33 no.1
    • /
    • pp.17-27
    • /
    • 2022
  • Fluorescence imaging is widely used to image cells or small animals due to its high temporal and spatial resolution. Because conventional fluorescence imaging uses visible light, the penetration depth of light within the tissue is low, phototoxicity may occur due to visible light, and the detection sensitivity is lowered due to interference by background autofluorescence. In order to overcome this limitation, long-wavelength light should be used, and fluorescence imaging using near-infrared-I (NIR-I) in the region of 700~900 nm has been developed. To further improve imaging quality, researchers are interested in using a longer wavelength light, near-infrared-II (NIR-II) ranging from 1000 to 1700 nm. In the NIR-II region, light scattering is further minimized, and the penetration depth of light in the tissue is improved up to about 10 mm, and autofluorescence of the tissue is reduced, enabling high sensitivity and resolution fluorescence imaging. In this review, among various NIR-II fluorescence imaging probes, inorganic nanoparticle-based probes with excellent photostability and easily tunable emission wavelength were described, focusing on single-walled carbon nanotubes, quantum dots, and lanthanide nanoparticles.

Photoinhibition and Recovery of Anacystis nidulans Adapted in Blue-Green Light

  • Young-Nam Hong
    • Journal of Plant Biology
    • /
    • v.38 no.1
    • /
    • pp.1-10
    • /
    • 1995
  • Photoinhibition and its recovery of spectrally adapted Anacystis nidulans were studied. Phycocyanin and Chl content and phycocyanin/Chl ratio were increased in cells grown under blue-green light compared with those grown in white light. Photosynthetic activities of white light and blue-green light grown cells were reduced by 50% after 15 min and 10 min of photoinhibitory light treatment (1.2 mmol·m-2s-1), respectively, largely due to the decline of PSII activities. However, their activities were recovered fully after 30 min incubation under weak light. Treatment of rifampicin and chloramphenicol magnified the photoinhibitory effects and suppressed the recovery with disappearance of susceptibility to photoinhibition and delayed the recovery process, indicating no significant differences in phosphorylation, dephosphorylation and protease activity between two cells. Therefore, it is suggested that the increased sensitivity of blue-green adapted cells might be attributed to the decline of protein synthesis, and phosphorylation-dephosphorylation of protein and protease activity might be involved in the recovery process.

  • PDF

An Evaluation of the Tolerance of the Static Characteristics for Light Weight Torpedoes (경어뢰의 정특성 허용오차 산정)

  • 나영인
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.149-158
    • /
    • 2002
  • Static Characteristics of the system, such as weight, center of gravity etc., are inspected and regulated through the whole design process of a light weight torpedo system, and the nominal condition of the characteristics is prescribed for standardization of manufacturing and fabrication. It is possible that a real system or assembled system has different static characteristics from that of the nominal condition. It is required to evaluate the tolerance of the static characteristics within which the performance of the system should not be contaminated by the static characteristics. In this paper, an evaluation method of the tolerance is described for light weight torpedo systems. The method is to check on the performance and related critical parameters of light weight torpedoes. The checking items are composed of general conditions of underwater mobile systems such as stability and dynamic sensitivity and specified performance requirements for light weight torpedoes.

Optical Sensitivity of TL Glow Peaks Separated Using Computerized Glow Curve Deconvolution for RTL Quartz

  • Kim, Myung-Jin;Kim, Ki-Bum;Hong, Duk-Geun
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.3
    • /
    • pp.114-119
    • /
    • 2018
  • Background: The retrospective dosimetry using RTL quartz can be improved by information for an optical sensitivity of sample connected with the equivalent dose determination. Materials and Methods: The quartz sample from a volcanic rock of Japan was used. After correcting the thermal quenching effect, RTL peaks of quartz were separated by the CGCD method cooperated with the general order kinetics. The number of overlapped glow peaks were ascertained by the $T_m-T_{stop}$ method. The optical sensitivity was examined by comparing the change of intensity on RTL glow peaks measured after exposure to light from a solar simulator with various illumination times. Results and Discussion: Seven glow peaks appeared to be overlapped on the RTL glow curve. The general order kinetics model was appropriate to separate glow peaks. After exposure to light from a solar simulator from a few minutes to 416 hr, the signals for peaks P4 and P5 decayed following the form of $f(t)=a_1e^{-{\lambda}1t}$, while the signals for peaks P6 and P7 decayed by the form of $f(t) = a_1e^{-{\lambda}1t}+a_2e^{-{\lambda}2t}+a_3e^{-{\lambda}3t}$. Conclusion: For dosimetric peaks, the times taken to reduce the RTL signal to half of its initial value were 70 sec for the peak P4, 54 s for the peak P5, 9,840 sec for the peak P6 and 26,580 sec for the peak P7, respectively. We conclude that the optical sensitivity of peaks P4, and P5 gives much higher than that of peaks P6 and P7.

UV Sensitivity of Korean Skin and The Effects of Factors affecting SPF Determination (한국인 피부의 자외선 감수성과 SPF 측정치에 미치는 인자의 영향)

  • 이병곤
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.17 no.1
    • /
    • pp.1-17
    • /
    • 1991
  • Multiport-600 Solar SimulatorR is one of the most recent and convenient in-strument for evaluation of sun protection factor(SPF). In this study, we examined the practicability of the SPF determining system using Multiport -600 and the effects of several factors-light sources, seasons and experimental animals-on the minimal erythema dose(MED) and SPF. We also tested the UV sensitivity according to the sites of Korean people, And the ultraviolet radiation reaching the earth's surface In Seoul have been observed for one year. As a result of this study, the determinig system for SPF using Multiport-600 was proved to be a good system in accuracy and time-saving. The biological activity of fluorescence UV lamp of PUVA-800R was significantly higher than natural light or solar simulator with Xe arc lamp, and the determined MED became lower in inverse proportion to room temperature rise. Skin sensitivity by ultraviolet adiation was hights. in order \circled1 back \circled2 inns, upper arm \circled3 outer upper arm \circled4 foream. We also observed that UV radiation intensity was highest at noon in july and 1 sun burn unit(MED) was 28 minutes at that time.

  • PDF

Design and Implementation of Optimal LED Emotional-Lighting Control System (최적의 LED 감성조명 제어 시스템 설계 및 구현)

  • Yun, Su-Jeong;Lin, Chi-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.8
    • /
    • pp.1637-1642
    • /
    • 2015
  • Next-generation applications using technology IT fused to biological signals from the emotional state to extract a lot of research has been, and the sensitivity of the human sensory functions influences the physiological condition known to be the fact that. In this paper, Propose an Emotional-lighting control algorithm using bio-signals. LED lighting for Emotion light is environmentally friendly and has a high efficiency and long life. In particular, LED lights are different colors represent the possible single light sphere advantages. And, Human sensitivity for determining a more accurate biological signals using EEG was collected using EEG equipment sensitivity was determined to analyze the EEG.