• Title/Summary/Keyword: light rays

검색결과 255건 처리시간 0.042초

Internet-Based Measuring/Monitoring System that Measures Drifted Snow Using Visual Image

  • Ko, Deok-Hyeon;Kim, Moo-Seong;Lee, Soon-Geul;Kim, Jin-Hyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.173.2-173
    • /
    • 2001
  • In this paper, an Internet-based monitoring system is studied which analyzes visual image of drifted snow and measures the amount of snowing. The system is composed with reference ruler where LED's are attached, a camera, and PC with a controller. The length of the ruler is 1.5m and the interval of the LED's is 1cm. The controller synchronizes the on-off control of each LED with the image frame of the camera. When the snow is accumulated along the ruler, the corresponding LED is blocked and the lowest position of the lighted LED is estimated with this captured image of the camera. Because of week intensity of LED light and light rays of outdoors, it is hard to discriminate which LED is blocked due to snow. Image processing method is used to obtain proper resolution and good accuracy. This system ...

  • PDF

광파이버를 이용한 관절각 센서의 개발 (The development of joint angle sensor using optical fiber)

  • 이현희;임승관;정호춘;이태호;진달복
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 B
    • /
    • pp.593-596
    • /
    • 1997
  • The main purpose of this paper is to develop sensing device of joint angle using loss of opfical fiber. The source of light to optical fiber is infrared rays diode, and receiver is a photo transistor. The bent angle of optical fiber is measured with rotary encoder, and The change of voltage due to the loss of light is measured with micro computer PIC16C74. The sensing device may be used to Functional Electrical stimulation(FES) System for Rehabilitation patient.

  • PDF

Real-time X-ray Scattering as a Nanostructure Probe for Organic Photovoltaic Thin Films

  • 이현휘;김효정;김장주
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.181-181
    • /
    • 2013
  • Recently, nanostructure and the molecular orientation of organic thin films have been largely paid attention due to its importance in organic electronics such as organic thin film transistors (OTFTs), organic light emitting diodes (OLEDs), and organic photovoltaics (OPVs). Among various methods, the diffraction and scattering techniques based on synchrotron x-rays have shown powerful results in organic thin film systems. In this work, we introduce the in-situ annealing system installed at PLS-II (Pohang Light Source II) for organic thin films by simultaneously conducting various x-ray scattering measurements of x-ray reflectivity, conventional x-ray scattering, grazing incidence wide angle x-ray scattering (GI-WAXS) and so on. Using the in-situ measurement, we could obtain real time variation of nanostructure as well as molecular orientation during thermal annealing in metal-phthalocyanine thin films. The variation of surface and interface also could be simultaneously investigated by the x-ray reflectivity measurement.

  • PDF

PSD센서를 이용한 실시간 3차원 위치의 복원 (Restoration of Realtime Three-Dimension Positions Using PSD Sensor)

  • 최훈일;조용준;유영기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.507-510
    • /
    • 2003
  • In this paper, optical sensor system using PSD(Position Sensitive Detection) is proposed to obtain the three dimensional position of moving markers attached to human body. To find the coordinates of an moving marrer with stereo vision system, two different sight rays of an moving marker are required. Usually, those are acquired with two optical sensors synchronized at the same time. PSD sensor is used to measure the position of an incidence light in real-time. To get the three-dimension position of light source on moving markers, a conventional camera calibration method are used. In this research, we realized a low cost motion capture system. The proposed system shows high three-dimension measurement accuracy and fast sampling frequency.

  • PDF

Experimental Techniques for Surface Science with Synchrotron Radiation

  • Jonhnson, R.L.;Bunk, O.;Falkenberg, G.;Kosuch, R.;Zeysing, J.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1998년도 제14회 학술발표회 논문개요집
    • /
    • pp.17-17
    • /
    • 1998
  • Synchrotron radiation is produced when charged particles moving with relativistic velocities a are accelerated - for example, deflected by the bending magnets which guide the electron or p positrons in circular accelerators or storage rings. By using special focusing magnetic lattices i in the particle accelerators it is possible to make the dimensions of the particle beam very small with a hi맹 charge density which results in a light source with high b디lIiance. Synchrotron light h has important properties which make it ideal for a wide range of investigations in surface s science. The fact that the spectrum of electromagnetic radiation emitted in a bending magnet e extends in a continuum from the 얹r infra red region to hard x-rays means that it is id않I for a v variety of spectroscopic studies. Since there are no convenient lasers, or other really bright l light sources, in the vacuum ultraviolet and soft x-ray re.밍ons the development of synchrotron r radiation has enabled enormous advances to be made in this di펌C비t spectr따 re밍on. P Polarization-dependent measurements, for ex없nple ellipsometry or circular dichroism studies a are possible because the radiation has a well-defined polarization - linear in the plane of orbit w with additional right-circular, or left-circular, components for emission an생es above, or below, t the horizontal, respectively. Since the synchrotron light is emitted from a bunch of charge c circulating in a ring the light is emitted with a well-defined time structure with a short flash of l light every time a bunch passes an exit port. The time structure depends on the size of the ring a and the number and sequence of filling of the bunches. A pulsed light source enables time¬r resolved studies to be performed which provide direct information on the lifetimes and decay m modes of excited states and in addition opens up the possibility of using time of flight t techniques for spectroscopic studies. The fact that synchrotron radiation is produced in a clean u ultrahi야 vacuum environment is of gr않t importance for surce science studies. The current t비rd generation synchrotron light sources provide exceptionally high baliance and stability a and open up possibilities for experiments which would have been inconceivable only a short time ago.

  • PDF

Simultaneous imaging and radiometric performance simulation for computer generated GOCI optical system with measured characteristics

  • Jeong, Soo-Min;Jeong, Yu-Kyeong;Ryu, Dong-Ok;Yoo, Jin-Hee;Kim, Seong-Hui;Cho, Seong-Ick;Ham, Sun-Jeong;Youn, Heong-Sik;Woo, Sun-Hee;Kim, Sug-Whan
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2008년도 한국우주과학회보 제17권2호
    • /
    • pp.27.3-28
    • /
    • 2008
  • In this study, we report a new Monte Carlo ray tracing technique for estimating GOCI (Geostationary Ocean Color Instrument) radiative transfer characteristics and imaging performance simultaneously. First, a full scale GOCI optical model was constructed with measured characteristics at the component level and placed in the geostationary orbit. An optical model of approximated GOCI target area centered at the Korean penninsular was then built using the USGS coastal line data and representative land and sea surface reflectivity data. The light rays launched from a simulated sun model travel to the Earth surface, where they are reflected and scattered. Some of the light rays that are headed to the GOCI model in the orbit were selected and traced, as they have entered into the GOCI aperture. As they pass through each GOCI optical part, the ray path and intensity are adjusted according to the measured characteristics for reflection, transmission, refractive index and surface scattering. The ray-traced imaging and radiative transfer performance indicators confirm that the computer generated GOCI optical system with measured characteristics can be used for in-orbit operation simulation following the designed measurement sequence. The computational technique and its implications as a operation support tool are discussed.

  • PDF

저가형 열영상 시스템을 위한 실리콘 윈도우 제작 (Fabrication of Silicon Window for Low-price Thermal Imaging System)

  • 성병목;정동건;방순재;백선민;공성호
    • 센서학회지
    • /
    • 제24권4호
    • /
    • pp.264-269
    • /
    • 2015
  • An infrared (IR) bolometer measures the change of resistance by absorbing incident IR radiation and generates a signal as a function of the radiation intensity. Since a bolometer requires temperature stabilization and light filtering except for the infrared rays, it is essential for the device to be packaged meeting conditions that above mentioned. Minimization of heat loss is needed in order to stabilize temperature of bolometer. Heat loss by conduction or convection requires a medium, so the heat loss will be minimized if the medium is a vacuum. Therefore, vacuum packaging for bolometer is necessary. Another important element in bolometer packaging is germanium (Ge) window, which transmits IR radiation to heat the bolometer. To ensure a complete transmittance of IR light, anti-reflection (AR) coatings are deposited on both sides of the window. Although the transmittance of Ge window is high for IR rays, it is difficult to use frequently in low-price IR bolometer because of its high price. In this paper, we fabricated IR window by utilizing silicon (Si) substrate instead of Ge in order to reduce the cost of bolometer packaging. To enhance the IR transmittance through Si substrate, it is textured using Reactive Ion Etching (RIE). The texturing process of Si substrate is performed along with the change of experimental conditions such as gas ratio, pressure, etching time and RF power.

가시광선과 원적외선 듀얼카메라의 영상 정합도 향상을 위한 동축광학계 설계 및 분석 (Design and Analysis of Coaxial Optical System for Improvement of Image Fusion of Visible and Far-infrared Dual Cameras)

  • 강규리;김영일;손병수;박진영
    • 한국광학회지
    • /
    • 제34권3호
    • /
    • pp.106-116
    • /
    • 2023
  • 본 논문에서는 가시광선과 원적외선 전반의 파장대역에 걸쳐 사용 가능한 동축 듀얼카메라를 설계 및 분석하였다. 광학계는 빔 스플리터를 이용한 동축광학계 시스템으로 설계되었으며, 가시광선 광학계에서 적외선으로 인한 열 전달을 최소화하기 위해 hot mirror 타입의 빔 스플리터를 사용하였다. 원적외선 카메라는 비냉각형 검출기로 640×480의 센서 배열을 가지고, 가시광선은 1,945×1,097의 센서를 사용한다. 최적화 과정을 거친 후 최종 설계된 광학계의 정합도는 90% 이상이며, 기존에 존재하던 듀얼카메라에 비해 정합도가 향상된 효율적인 설계 결과를 얻었고, 테스트를 통해 향상된 정합도를 확인하였다.

제주도에서 출현한 농어목 어류의 3 미기록종 (New Record of Three Percoids (Pisces: Perciformes) from Cheju Island, Korea)

  • 윤창호
    • 한국어류학회지
    • /
    • 제10권2호
    • /
    • pp.260-267
    • /
    • 1998
  • 1996년부터 1998년까지 매년 7월에 1주일 동안 제주도 주변에서 출현하는 어류를 채집, 동정한 결과, 농어목 어류의 한국산 3미기록종이 출현하였다. 실꼬리돔과의 Nemipterus bathybius Snyder, 1911(국명신칭: 긴실꼬리돔)는 뒷지느러미 연조가 7개이며, 꼬리지느러미의 최상단 연조가 사상으로 길게 뻗은 특징으로 구분된다. Family Cirrhitidae(국명신청: 황붉돔과)의 Cirrhitichthys aureus (Temminck et Schlegel, 1842)(국명신청: 황붉돔)는 체 측상단부에 5~6개의 연한 흑색 반점들이 산재되어있고, 둥지느러미 연조가 12개인 점 및 등지느러미에 반점이나 반문이 없는 특징으로 구분된다. 또한 양동미리과의 Parapercis aurantiaca Doderlein, 1884(국명신칭 : 황쌍동가리)는 결각없이 등지느러미의 극조부와 연조부가 연결된 점과 체측부에 눈 크기와 비슷한 짙은 황색반문이 5~6개 있는 특징에 의하여 구분된다.

  • PDF

Study on bubble detection sensor for safe sap and blood injection

  • Yun, Young Gi;Lee, Hoo Young;Park, Koo Rack
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권9호
    • /
    • pp.149-154
    • /
    • 2017
  • The infusion of fluid and blood is necessary in the ward, operating room, recovery room, neonatal room, etc. for nutrition and blood supply to the patient, but air bubbles generated during infusion of fluid and blood circulate along the artery or vein. Serious illnesses occur and there is also a risk of death. In this paper, we propose a medical bubble detection system, a bubble detection system, a bubble detection alarm system, and a communication method in order to develop a safer fluid and blood injection system in the existing system, which is detected by a medical staff monitoring system or an ultrasonic bubble detection sensor In this study, infrared rays are transmitted to a tube through a tube for injecting fluid or blood into a patient, infrared rays transmitted by an infrared ray emitting section are received, and the amount of light is measured in real time. Based on the data, we study how to detect and analyze the presence of bubbles in fluid and blood.