• 제목/요약/키워드: light curing

검색결과 464건 처리시간 0.025초

건조수축에 따른 균열 억제를 위한 규사 혼입 CLC의 특성 (Properties of CLC using Silica to Suppress Cracking due to Drying Shrinkage)

  • 이창우;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.125-126
    • /
    • 2021
  • In order to improve the housing culture, construction changes for the utilization of diverse and multifunctional spaces are appearing in response to the increasing diverse needs of consumers. Cellular Light-weight Concrete (CLC) is being developed for use in fire-resistant heat-insulating walls and non-bearing walls. However, manufacturing non-uniformity has become a problem as a drawback due to the use of foamed bubbles and normal temperature curing, and additional research is required. Therefore, in order to suppress cracks due to drying shrinkage, silica sand is mixed with CLC to try to understand its characteristics. In the experiment, the compressive strength from 7 to 28 days of age was measured via a constant temperature and humidity chamber, and the drying shrinkage was analyzed according to each condition using a strain gauge. The compressive strength of matrix tends to decrease as the substitution rate of silica sand increases. This is judged by the result derived from the fact that the specific surface area of silica sand is smaller than that of slag. Based on KS F 2701 (ALC block), the compressive strength of 0.6 products is 4.9 MPa or more as a guide, so the maximum replacement rate of silica sand that satisfies this can be seen at 60%. Looking at the change in drying shrinkage for just 7 days, the shrinkage due to temperature change and drying is 0.7 mm, and the possibility of cracking due to shrinkage can be seen, and it seems that continuous improvement and supplementation are needed in the future.

  • PDF

중합조건에 따른 dual cured resin cement의 열분석적 연구 (THERMAL ANALYSIS OF THE DUAL CURED RESIN CEMENTS ACCORDING TO CURING CONDITION)

  • 이인복;정관희;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.265-285
    • /
    • 1999
  • The purposes of this investigation were to observe the reaction kinetics of five commercial dual cured resin cements (Bistite, Dual, Scotchbond, Duolink and Duo) when cured under varying thicknesses of porcelain inlays by chemical or light activation and to evaluate the effect of the porcelain disc on the rate of polymerization of dual cured resin cement during light exposure by using thermal analysis. Thermogravimetric analysis(TGA) was used to evaluate the weight change as a function of temperature during a thermal program from $25{\sim}800^{\circ}C$ at rate of $10^{\circ}C$/min and to measure inorganic filler weight %. Differential scanning calorimetry(DSC) was used to evaluate the heat of cure(${\Delta}H$), maximum rate of heat output and peak heat flow time in dual cured resin cement systems when the polymerization reaction occured by chemical cure only or by light exposure through 0mm, 1mm, 2mm and 4mm thickness of porcelain discs. In 4mm thickness of porcelain disc, the exposure time was varied from 40s to 60s to investigate the effect of the exposure time on polymerization reaction. To investigate the effect on the setting of dual cured resin cements of absorption of polymerizing light by porcelain materials used as inlays and onlays, the change of the intensity of the light attenuated by 1mm, 2mm and 4mm thickness of porcelain discs was measured using curing radiometer. The results were as follows 1. The heat of cure of resin cements was 34~60J/gm and significant differences were observed between brands (P<0.001). Inverse relationship was present between the heat of reaction and filler weight % the heat of cure decreased with increasing filler content (R=-0.967). The heat of reaction by light cure was greater than by chemical cure in Bistite, Scotchbond and Duolink(P<0.05), but there was no statistically significant difference in Dual and Duo(P>0.05). 2. The polymerization rate of chemical cure and light cure of five commercially available dual cured resin cements was found to vary greatly with brand. Setting time based on peak heat flow time was shortest in Duo during chemical cure, and shortest in Dual during light cure. Cure speed by light exposure was 5~20 times faster than by chemical cure in dual cured resin cements. The dual cured resin cements differed markedly in the ratio of light and chemical activated catalysts. 3. The peak heat flow time increased by 1.51, 1.87, and 3.24 times as light cure was done through 1mm, 2mm and 4mm thick porcelain discs. Exposure times recommended by the manufacturers were insufficient to compensate for the attenuation of light by the 4mm thick porcelain disc. 4. A strong inverse relationship was observed between peak heat flow and peak time in chemical cure(R=0.951), and a strong positive correlations hip was observed between peak heat flow and the heat of cure in light cure(R=0.928). There was no correlationship present between filler weight % or heat of cure and peak time. 5. The thermal decomposition of resin cements occured primarily between $300^{\circ}C$ and $480^{\circ}C$ with maximum decomposition rates at $335^{\circ}C$ and $440^{\circ}C$.

  • PDF

Antibacterial effect of self-etching adhesive systems on Streptococcus mutans

  • Kim, Seung-Ryong;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • 제39권1호
    • /
    • pp.32-38
    • /
    • 2014
  • Objectives: In this study, we evaluated the antibacterial activity of self-etching adhesive systems against Streptococcus mutans using the agar diffusion method. Materials and Methods: Three 2-step systems, Clearfil SE Bond (SE, Kuraray), Contax (CT, DMG), and Unifil Bond (UnB, GC), and three 1-step systems, Easy Bond (EB, 3M ESPE), U-Bond (UB, Vericom), and All Bond SE (AB, BISCO) were used. 0.12% chlorhexidine (CHX, Bukwang) and 37% phosphoric acid gel (PA, Vericom) were used as positive controls. Results: The antibacterial activity of CHX and PA was stronger than that of the other groups, except SE. After light activation, the inhibition zone was reduced in the case of all 2-step systems except CT. However, all 1-step systems did not exhibit any inhibition zone upon the light activation. Conclusions: SE may be better than CT or UnB among the 2-step systems with respect to antibacterial activity, however, 1-step systems do not exhibit any antibacterial activity after light curing.

포토마스크가 필요 없는 스크린 제판 기술 개발(II) (A Development on the Non-Photomask Plate Making Technology for Screen Printing (II))

  • 박경진;강효진;김성빈;남수용;안병현
    • 한국인쇄학회지
    • /
    • 제26권2호
    • /
    • pp.45-54
    • /
    • 2008
  • We have manufactured a photoresist which has excellent dispersity and good applying property due to 330 cps of viscosity for environment-friendly and economical maskless screen plate making. And the photoresist applied on the screen stretched was exposed with mask by UV-LED light source so we could manufacture the photoresist which proper for the UV light source. And it was developed by air spray with $1.7\;kgf/cm^2$ of injection pressure. Because of the excellence of power and resolution of the UV-LED light sourse, the pencil hardness and solvent resistance of curing photoresist film were excellent as those of conventional photoresist film. Moreover the $100{\mu}m$-width stripe image which has sharp edges was formed. So we confirmed a possibility of dry development process by air spray method.

  • PDF

포토마스크가 필요 없는 스크린 제판 기술 개발(III) (A Development on the Non-Photomask Plate Making Technology for Screen Printing (III))

  • 강효진;박경진;김성빈;남수용;안병현
    • 한국인쇄학회지
    • /
    • 제26권2호
    • /
    • pp.55-64
    • /
    • 2008
  • We designed a UV-LED exposure system which has 365nm dominant wavelength due to the environment-friendly and economical maskless screen plate making. And the photoresist applied on the screen stretched was exposed without mask by beam projector with UV-LED light source. Then it was developed by air spray with $1.7\;kgf/cm^2$ of injection pressure. The pencil hardness and solvent resistance of curing photoresist film were excellent as those of conventional photoresist film and the maximum resolution of line image formed by maskless screen plate making. was $100{\mu}m$, so we could establish the possibility of environment-friendly maskless screen plate making technology. But the sharpness of the patterns were ${\pm}40{\mu}m$ since the exposure system for maskless plate making has weak light intensity and the diffusion of light.

  • PDF

진공 프린팅 성형 인쇄법(VPES)을 이용한 R.G.B.Y(Red, Green, Blue, Yellow) LED 광원 연구 (A Study on RGBY LED Light using a Vacuum Printing Encapsulation Systems Method)

  • 장민석;김영우;신기해;박정욱;홍진표;송상빈;김재필
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.10-18
    • /
    • 2011
  • In order to develop highly-integrated RGBY(Red, Green, Blue, Yellow) LED light, a high thermal radiation ceramic package was manufactured, and the encapsulation process was applied with a vacuum printing encapsulation system(VPES). After the completion of vacuum printing, the shape of the encapsulation layer could be controlled by heat treatment during the curing process, and the optical power became highly increased as the encapsulation layer approached a dome shape. The optical characteristics involved in a Correlated Color Temperature(CCT), a Color Rendering Index (CRI), and the efficiency of RGBY LED light were able to be identified by the experimental designing method. Regarding the characteristics of the white light of RGBY LED light, which were measured on the basis of the aforementioned optical characteristics, CRI posted 88, CCT recorded 5,720[$^{\circ}K$], and efficiency exhibited 52[lm/W]. The chip temperature of RGBY LEDs was below 55[$^{\circ}C$] when the consumption power of LED chips was 0.1[W] for the red, 0.3[W] for the green, 0.08[W] for the blue, and 0.24[W] for the yellow. Also, the thermal resistance of the highly-integrated RGBY LED light measured by T3Ster was 2.3[K/W].

Fabrication of Patchable Organic Lasing Sheets via Soft Lithography

  • Kim, Ju-Hyung
    • 청정기술
    • /
    • 제22권3호
    • /
    • pp.203-207
    • /
    • 2016
  • Here, we report a novel fabrication technique for patchable organic lasing sheet based on non-volatile liquid organic semiconductors and freestanding polymeric film with high flexibility and patchability. For this work, we have fabricated the second-order DFB grating structure, which leads to surface emission, embedded in the freestanding polymeric film. Using an ultra-violet (UV) curable polyurethaneacrylate (PUA) mixture, the periodic DFB grating structure can be easily prepared on the freestanding polymeric film via a simple UV curing process. Due to unsaturated acrylate remained in the PUA mixture after UV curing, the freestanding PUA film provides adhesive properties, which enable mounting of the patchable organic lasing sheet onto non-flat surfaces with conformal contact. To achieve laser actions in the freestanding resonator structure, a composite material of liquid 9-(2-ethylhexyl)carbazole (EHCz) and organic laser dyes was used as the laser medium. Since the degraded active materials can be easily refreshed by a simple injection of the liquid composite, such a non-volatile liquid organic semiconducting medium has degradation-free and recyclable characteristics in addition to other strong advantages including tunable optoelectronic responses, solvent-free processing, and ultimate mechanical flexibility and uniformity. Lasing properties of the patchable organic lasing sheet were also investigated after mounting onto non-flat surfaces, showing a mechanical tunability of laser emission under variable surface curvature. It is anticipated that these results will be applied to the development of various patchable optoelectronic applications for light-emitting displays, sensors and data communications.

침장용 PLA 섬유에 대한 저온 경화유제에 관한 연구 (Study on Low Temperature Curing Emulsion of PLA Fiber for Bedding)

  • 안영무
    • 패션비즈니스
    • /
    • 제16권1호
    • /
    • pp.41-51
    • /
    • 2012
  • Polyester is mainly used as a bedding filler material. PLA fiber as an eco-friendly material for substituting polyester has a low melting temperature and therefore a hardening process is impossible. This study is to develop the oil for feather touch that can treat at the melting temperature of PLA. The slippery and soft aminosilicone emulsion, and the bulky epoxysilicone emulsion were used. They had proper viscosity and particle size for flexibility and elasticity. When using methoxy aminosilane [$H_2NSi(OCH_3)_3$] as an aminosilane and [$Zn(OCOCH_3)_2$] as a catalyst, the hardening reaction was fast and effective. Feather touch process were treated by 2 steps. At first step, aminosilicone emulsion, epoxysilicone emulsion and methylaminosilane were mixed and homogenized, and at second step, 5% blened solution of the first step, Zn catalyst 1%, distilled water 94% were treated at PLA fiber. After treatment the static friction coefficient and dynamic friction coefficient were reduced to 23.5-60.8% and 30.0-61.3% respectively, and the laundry and sun light fastnesses have not shown any decrease.

도재 및 레진 브라켓에 대한 광중합 접착제의 전단 접착 강도 (Shear bond strength of ceramic and resin brackets used with visible light-cured adhesives)

  • 황유선;노준;황충주
    • 대한치과교정학회지
    • /
    • 제26권2호
    • /
    • pp.233-244
    • /
    • 1996
  • 성인 환자의 증가와 심미적인 장치에 대한 요구가 증가하면서 도재나 레진 브라켓의 사용이 증가되고 있다. 이러한 브라켓에서의 광중합 접착제의 사용은 짧은 광조사 시간에서도 광중합 접착제의 많은 장점을 얻을 수 있다. 이에 본 연구에서는 심미적으로 우수한 수 종의 도재 및 레진 브라켓을 수 종의 광중합 접착제로 접착시켜 전단 접착 강도와 접착 파절 양상을 관찰하였다. 교정 치료를 위해 발거한 140개의 소구치를 협측면이 노출되도록 자가중합 레진으로 매몰하고 소구치 협측면에 Plastlc bracket, Transcend 6000, Signature 및 Starfire TMB 브라켓을 Orthobond, Light Bond 및 Transbond로 제조자 지시에 따라 접착시켜 열변환기 로 1800회 온도 변화를 준 후 전단 접착 강도를 만능시험기로 측정하고 접착 파절 양상을 입체현미경으로 관찰하였고 10초와 20초의 광조사 시간과 두가지 광원에 대해 전단 접착 강도를 비교하여 다음의 결과를 얻었다. 1. 동일한 브라켓을 Orthobond, Light Bond와 Transbond로 접착시켰을 때 이들간의 전단 접착 강도는 Plastic bracket을 제외하고는 통계학적 유의차가 없었다(p<0.05). 2. 동일한 접착제로 Plastic bracket, Transcend 6000, Signature, Starfire TMB를 접착시켰을 때 이들간의 전단 접착강도는 통계학적 유의차를 보였다(p<0.05). Starfire TMB에서 가장 큰 전단 접착강도를 보였고 이는 Transcend 6000과 통계학적 유의차가 없었으나 Singnature와는 통계학적 유의차를 보였다(p<0.05). 3. 접착 파절은 전체 군에서 잔류 접착제가 반 이상 또는 모두 치아면에 남은 경우가 $72.1\%$로 대개 브라켓과 접착제 사이에서 파절이 일어났다. 4. 접착제 중합을 위한 광조사 시간은 10초와 20초에서 전단 접착 강도에 통계학적 유의차를 보이지 않았으며 $400mW/cm^2$ 이상의 광도에서는 서로 다른 광원을 사용해도 전단 접착 강도에 통계학적 유의차를 나타내지 않았다(p<0.05). 이상의 결과로 보아 도재 브라켓의 전단 접착강도는 브라켓 조성과 브라켓 접착면의 유지형태 차이에 의해 영향을 받고 광중합 접착제 종류에 따른 접착 강도의 차이는 나타나지 않았으며 임상에서 브라켓이나 접착제 선택시 이를 고려해야 할 것으로 사료된다.

  • PDF

수종 상아질 접착제의 결합강도와 중합률에 관한 연구 (A STUDY ON BONE STRENGTH AND THE DEGREE OF CONVERSION OF DENTIN BONDING AGENTS)

  • 김병현;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.68-93
    • /
    • 1998
  • The physical properties of polymer are greatly influenced by the extent to which a resin cures. The presence of un reacted monomer can, have a plasticizing effect on the polymer, thereby altering the physical and mechanical properties of dentin bonding agent (DBA). If the DBA does not polymerize sufficiently, it will leave a weak bonding layer and lead to lower bond strength. The purpose of this study was to evaluate the shear bond strengths(SBS) and the degree of conversion (DC) of 4 commercialy avilable dentin bonding systems which are composed of 2 multi-bottle systems [Scotchbond Multi-Purpose (SMP), AeliteBond(AB)] and 2 onebottle systems [SingleBond(SB), One-Step(OS)]. For shear bond strength measurement, labial surfaces of freshly extracted bovine incisors were ground with # 600 grit SiC paper to expose dentin. Four different groups of samples were formed, with 10 samples. being made for each of the 4 commercial DBA in each group according to the curing sequences of DBA and overlayer thickness of composites: Group I (standard cure and 1mm thick composites) : The DBA was light cured and the composites of 1mm thickness was applied ; Group II (standard cure and 2mm thick composites) : The DBA was light cured and the composites of 2mm thickness was applied; Group III (simultaneous cure and 1mm thick composites) : The DBA was not light-cured and simultaneously cured with composites of 1mm thickness; Group N (simultaneous cure and 2mm thick composites) : The DBA was. not light-cured and simultaneously cured with composites of 2mm thickness. The SBS was measured immediately after the composites was bonded to the bovine dentin using an Instron machine. The DC of the DBA was examined in a thin film under simulated conditions of the experimental groups according to the curing sequences and overlayer thickness of composites in the SBS test. using a Fourier transform Infrared(FTIR) spectrometer. The following results were obtained from SBS tests and DC measurements 1. In SBS tests, the multi-bottle DBA(SMP, AB) had a generally higher bond strength values than the one bottle DBA(SB, OS). In DC measurements, the one bottle DBA(SB, OS) had a significantly higher DC than the multi-bottle DBA(SMP, AB). 2. In all DBAs except OS, there was no significant difference between the bond strength of group I (standard cure and 1mm thick composites) and that of group III (simultaneous cure and 1mm thick composites). SMP, SB in Group I had a significantly higher DC than those in group III, but AB, OS in group I had a significantly lower DC than those in group III 3. All DBAs in Goup II (standard cure and 2mm thick composites) had significantly higher bond strength and DC than those in Group N (simultaneous cure and 2mm thick composites). 4. In all DBAs, there was no significantly different SBS and DC between Group I and Group II, but all DBAs in Group III had significantly higher SBS and DC than those in Group IV.

  • PDF