• Title/Summary/Keyword: light curing

Search Result 464, Processing Time 0.027 seconds

UV 경화가 비닐에스터와 불포화폴리에스터 블랜드 시스템의 물성 특성에 미치는 영향 (Effect of Radiation Intensity on Mechanical Properties of UV-cured Vinylester/Unsaturated Polyester Blend System)

  • Lee, Jae-Rock;Kim, Young-Mi;Park, Soo-Jin
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 추계학술발표대회 논문집
    • /
    • pp.269-272
    • /
    • 2002
  • UV curing technology becomes important in various sectors of applications due to the high efficiency, environmental protection, and saving of energy. The effect of different proportion of vinylester (VE) and unsaturated polyester (UP) for VE/UP blend system was investigated in context of mechanical properties. The compositions of VE/UP blend were varied within 0:100, 20:80, 40:60, 60:40, 80:20, and 100:0 by weight percent. 1 wt% 1-hydroxy-cyclohexyl-phenyl-ketone was used as photoinitiator. The used intensity of UV light was in the range of $40~70 mW/\textrm{cm}^2$. The flexural strength of vinylester was not sensitive to the intensity of UV light. But the unsaturated polyester was very sensitive to the intensity of UV light. The flexural strength of vinylester was always superior to that of unsaturated polyester. The addition of the vinylester increased the flexural strength of blend system.

  • PDF

LCD 와 가시광선 LED 기반의 광조형 시스템을 위한 수지의 경화 특성 (Curing Characteristics for Projection Stereolithography based on LCD and Visible LED)

  • 김가영;하영명;박인백;김민섭;조광호;이석희
    • 한국정밀공학회지
    • /
    • 제30권8호
    • /
    • pp.878-884
    • /
    • 2013
  • Stereolithography can be classified into two main categories according to the cross-sectional shape: scanning type and projection type. Projection stereolithography has significant advantages when making a layer using a single patterned beam, and results in improved speed and accuracy. To implement relatively low-cost projection stereolithography, we developed a system using a commercially available resin, which cures on exposure to visible light. The optimum photoinitiator was investigated, as well as the mixing ratio. The viscosity, shrinkage, curing depth and tensile strength were evaluated through several experiments on fabricated three-dimensional structures, and thus an optimal resin selection system was developed.

온성방법과 단면형태가 수종의 의치상 수리레진의 결합강도에 미치는 영향 (THE EFFECT OF PROCESSING METHOD AND SURFACE DESIGN ON THE TRANSVERSE STRENGTH OF REPAIRED DENTURE BASE RESIN)

  • 김강남;배태성;한중석
    • 대한치과보철학회지
    • /
    • 제34권4호
    • /
    • pp.665-674
    • /
    • 1996
  • This study was designed to evaluate the effect of processing method and surface design on the transverse strength of repaired denture base resin. Three heat-cured denture base resins(Vertex, Lucitone, Lang), one cold-cured resin(Lang), and one light-cured resin(Dentacolor gingiva material) were used for repair purpose. The specimens for 3-point flexure test were fabricated by five processing methods such as self-curing, pressure pot, boiling water, processing, and light curing. Finally to evaluate the effect of surface designs for repaired resin, three surface designs(butt, bevel, inverse bevel) were tested. Within the limit of this study, following conclusions were drawn. 1. Lucitone denture base material showed highest flexural strength of $131.37{\pm}2.15MPa$, and there were significant differences in stength between Lucitone and other resins. 2. Between two different self curing methods, self curing repair resin, Lang, cured by pressure pot method showed highest flexural strength, $58.49{\pm}4.89MPa$. 3. Among the heat cured repair resins, maximum transverse strength value of $88.69{\pm}16.60MPa$ was recorded in Lucitone group cured by processing method. 4. Inverse bevel joint design showed significantly higher bond strength than butt joint group, Maximum bond strength was $59.36{\pm}1.33MPa$ in inverse bevel joint design group.

  • PDF

광중합 복합레진의 중합초기 동적 점탄성의 변화 (THE CHANGE OF THE INITIAL DYNAMIC VISCO-ELASTIC MODULUS OF COMPOSITE RESINS DURING LIGHT POLYMERIZATION)

  • 김민호;이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제34권5호
    • /
    • pp.450-459
    • /
    • 2009
  • 본 연구의 목적은 새로 개발한 점탄성 측정기를 사용하여 수종의 광중합 복합레진의 초기 동적 점탄성 변화를측정하는 것이다. 본 연구에 사용된 점탄성 측정기는 세 부분으로 구성되었다. 첫째, 시편이 놓여지는 parallel plates; 둘째, DC 모터와 크랭크로 이루어진 회전진동전단변형 (Oscillatory shear strain)을 발생시키는 부분; 셋째, 전자기적 토크센서를 이용한 응력 측정 부분으로 구성되었다. 본 점탄성 측정기는 최대 2 Ncm의 토크를 측정할 수 있으며, 광중합기의 스위치는 컴퓨터와 연동하여 데이터 획득을 시작할 때 동시에 켜지도록 하였다. 본 연구에서는 시판 중인 6종의 광중합 복합레진 [Z-100 (Z1), Z-250 (Z2), Z-350 (Z3), DenFil (DF), Tetric Ceram (TC), Clearfil AP-X (CF)]을 사용하였다. 점탄성 측정기를 사용하여 동적 회전전단실험을 시행하였다. 직경 3 mm인 유리막대로 구성된 parallel plates 사이에 $14.2\;mm^3$의 복합레진을 적용시켰으며, 6 Hz의 진동수와 0.00579 rad의 진폭으로 변형을 가하고 발생된 응력을 측정하였다. 광중합이 시작됨과 동시에 측정이 시작되었으며, 광중합 후 10초 동안 점탄성의 변화를 관찰하였다. 각 복합레진에 대해 5 회 반복하여 측정하였고, 실험은 $25{\pm}0.5^{\circ}C$에서 진행되었다. 측정된 변형-응력 곡선으로부터 복소전단탄성계수 G*, 저장전단탄성 계수 G', 손실전단탄성 계수 G"를 구하였고 G*가 10 MPa에 이르는 시간을 구하였다. 각 재료의 복소전단탄성계수 G*와 10 MPa에 이르는 시간에 대해 일원분산분석 (One-way ANOVA)과 사후검정 (Tukey 검정)을 시행하였다 (${\alpha}$= 0.05). 결과는 다음과 같다. 1.본 연구를 위해 제작한 점탄성 측정기는 광중합 복합레진의 중합 초기 10초 동안의 동적 점탄성 변화를 신뢰성 있게 측정 할 수 있었다. 2. 모든 복합레진은 광조사 개시 후 $1{\sim}2$초의 불응기를 지난 다음 급격한 전단탄성계수의 증가를 보였다. 3. 모든 복합레진은 광중합 10 초간 손실전단탄성계수보다 저장전단탄성계수의 높은 증가를 보였다. 4. 광중합 초기 10초 후 복소전단탄성계수 값은 $150.3{\sim}563.7\;MPa$로, Z-100이 가장 높았고, 그 다음 Clearfil, Z-250, Z-350, Tetric Ceram, DenFil의 순이었다. 5. 복소전단탄성계수가 10 MPa에 이르는 시간은 Z-100이 2.55초로 가장 빨랐고, DenFil이 4.06초로 가장 느렸다.

광원의 유형에 따른 광중합 수복재의 중합양상 (A STUDY ON THE MODE OF POLYMERIZATION OF LIGHT-CURED RESTORATIVE MATERIALS CURED WITH THREE DIFFERENT LIGHT SOURCES)

  • 권민석;정태성;김신
    • 대한소아치과학회지
    • /
    • 제30권2호
    • /
    • pp.229-237
    • /
    • 2003
  • 본 연구는 기존의 할로겐광(XL 3000, 3M, U.S.A.)과 비교하여 새로운 중합광원인 플라즈마광(Flipo, LOKKI, France)과 Light Emitting Diode(이하 LED, Elipar Free light, 3M, U.S.A.)광의 효율성을 평가할 목적으로 시도되었다. 이에 본 연구에서는 첫째, 일정 광도 하에서 플라즈마광과 LED광의 중합시간에 따른 중합도의 변화를 검토하여 할로겐광의 미세경도와 유사한 광조사 시간을 알아보고, 둘째, 중합반경에 따라 균일한 중합이 이루어지는지를 보기 위해 광조사 부위의 중심부와 외측 변연부에서의 중합도의 차이를 비교하였다. 2mm 두께의 복합레진 시편의 상면과 하면의 미세경도의 측정을 통해 중합도를 평가, 비교해 본 결과 다음과 같은 결론을 얻었다. 1. Z-100의 미세경도 측정치 비교에서, 대조군인 할로겐광을 40초 적용한 경우는, 플라즈마광 6-9초, LED광 40-60초를 적용한 경우와 유사하였다(P>0.05). 2. Tetric Flow의 미세경도에서는 대조군인 할로겐광을 40초 적용한 경우, 플라즈마광 9초, LED광 40-60초를 적용한 경우와 유사하였다(P>0.05). 3. Dyract AP의 경우, 할로겐광 40초를 조사한 것은, 플라즈마광 6-9초, LED광 20-40초를 적용한 경우와 유사하게 나타났다(P>0.05). 4. Fuji II LC에서는 할로겐광을 40초 적용한 경우가, 플라즈마광 9초, LED광 20-60초를 적용한 경우와 유사하게 나타났다(P>0.05). 5. Fuji II LC를 제외한 모든 시료에서 할로겐, 플라즈마, LED광 모두 시편의 중앙에서 외측으로 갈수록 미세경도는 유의하게 감소되었다(p<0.05).

  • PDF

방진효과에 미치는 가류고무의 기계적성질에 관한 연구 (STUDIES ON THE MECHANICAL PROPERTIES OF THE CURING GUM IN THE PREVENTION OF VIBRATION)

  • 김동기
    • 한국수산과학회지
    • /
    • 제9권1호
    • /
    • pp.8-12
    • /
    • 1976
  • 1. 진동방지에는 $W/W_n<\sqrt{2}$일 때는 $C/_cC$가 큰 유화고무$(1\~2\%,\;4\~5\%)$가 좋다. 2. $W/W_n<\sqrt{2}$ 일때는 $C/_cC$가 작은 유화고무$(2.5\%\~3.5\%)$가 좋다. 3. 대수감쇠율의 값을 크게 하려면 저유화 고무가 좋다. 4. $\phi$ 및 R, $C/_cC$를 감안해서 $2.5\%\~3.5\%$의 유화 고무가 좋다. 5. $5\%이상$의 유화고무는 과유화관계상 좋지 못하다.

  • PDF

광중합 시 수종의 심미적 수복재와 이장재의 사용에 따른 치수내 온도변화 (TEMPERATURE CHANGES IN THE PULP ACCORDING TO VARIOUS ESTHETIC RESTORATIVE MATERIALS AND BASES DURING CURING PROCEDURE)

  • 장혜란;이형일;이광원;이세준
    • Restorative Dentistry and Endodontics
    • /
    • 제26권5호
    • /
    • pp.393-398
    • /
    • 2001
  • Polymerization of light-activated restorations results in temperature increase caused by both the exothermic reaction process and the energy absorbed during irradiation. Within composite resin, temperature increases up to 2$0^{\circ}C$ or more during polymerization. But, insulation of hard tissue of tooth lowers this temperature increase in pulp. However, many clinicians are concerned about intrapulpal temperature injury. The purpose of this study was to evaluate temperature changes in the pulp according to various restorative materials and bases during curing procedure. Caries and restoration-free mandibular molars extracted within three months were prepared Class I cavity of 3$\times$6mm with high speed handpiece fissure bur. 1mm depth of dentin was evaluated with micrometer in mesial and distal pulp horns. Pulp chambers were filled with 37.0$\pm$0.1$^{\circ}C$ water to CEJ. Chromium-alumina thermocouple was placed in pulp horn below restorative materials for evaluating of temperature changes. This thermocouple was connected to temperature-recording device(Multiplication analyzer MX, 6.000, JAPAN). Temperature changes was evaluated from initial 37.$0^{\circ}C$ after temperature changes to 37.$0^{\circ}C$. Tip of curing unit was placed in the center of prepared cavity separated 1mm from restorative materials. Curing time was 40s. The restorative materials were used with Z 100, Fuji II LC, Compoglass flow and bases were used with Vitrebond, Dycal. Resrorative materials were placed in 2mm. The depth of bases were formed in 1mm and in this upper portion, resin of 2mm depth was placed. This procedure was performed 10 times. The results were as follows. 1. All the groups showed that the temperature in pulp increased as curing time increased 2. The temperature increase of glass ionomer was significantly higher than that of Resin and Compomer during curing procedure (P<0.05). 3. The temperature increase in glass ionomer base was significantly higher than that of Calcium hydroxide base during Resin curing procedure (P<0.05).

  • PDF

유리섬유 보강재로 제작한 레진의치의 온성 전·후에 따른 정확성 평가 (Accuracy evaluation of resin complete denture made with glass fiber mesh reinforcement before and after curing)

  • 김동연;정일도;박진영;강신영;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.25-33
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate accuracy of glass fiber mesh complete denture of before and after curing. Methods: Edentulous model was selected as the master model. Ten study models were made by Type IV stone. Wax complete dentures were produced by the denture base and artificial teeth. CD and GD groups were measured six measurement distance before curing. The wax complete denture was investment after measurement is completed. Using a heat polymerization resin was injected resin. After injecting the resin it was curing. A complete denture was re-measured after curing. The measured data was verified by paired t-test. Results: Overall CD group was larger the value of the measured length. In the CD group, A-D point was larger. The smallest point was the B-D point. However, there was no statistically significant difference only C-D point(p>0.05). In the GD group, A-B point was larger. but B-D point was the smallest. A-D and B-C statistically points showed significant differences(p<0.05). Conclusion: Glass fiber mesh resin complete denture can be clinically applied to the edentulous patient.

수종의 이장재가 복합레진의 중합수축에 미치는 영향 (EFFECT OF VARIOUS LINERS ON THE POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN)

  • 최지원;이상호;이난영
    • 대한소아치과학회지
    • /
    • 제33권4호
    • /
    • pp.606-614
    • /
    • 2006
  • 이 연구의 목적은 이장재의 종류에 따른 광중합형 복합레진 충전 후 중합수축을 비교함으로써 중합수축 감소를 보이는 좀 더 우수한 재료의 조합을 모색하고자 시행되었다. 이장재로는 유동형 레진, 컴포머, 광중합 글래스아이오노머를 사용하였고 수축응력을 측정하기 위해 스트레인 게이지를 사용하였다. 표본은 광원의 종류, 이장재의 종류에 따라 8개의 군으로 나눠졌다. 스트레인 게이지를 아크릴릭 링에 부착하고 strainmeter에 연결한 후 각 군에 따라 이장재 적용 후 광중합 하고 이장재 중합 후 750초간 수축응력을 측정하였다. 결과는 Repeated measures ANOVA와 Tukey test를 이용해 통계학적으로 분석하였다. 이상의 실험을 통해 얻은 결과는 다음과 같다. 1. 이장재를 사용하지 않은 군보다 이장재를 사용한 군의 중합수축이 적었으나 Ionosit을 사용한 군에서는 유의한 차이는 없었다(p>0.05). 2, Tetric flow 또는 Vitrebond를 이장재로 사용하는 것이 Ionosit을 사용하는 것보다 중합 수축이 적었다(p<0.05). 3. Tetric flow 이장재를 한 군은 광원에 따른 수축력의 차이가 적었고 Vitrebond와 Ionosit 이장재를 한 군은 할로겐 광원보다 LED 광원에서 수축응력이 컸으나 유의한 차이는 없었다(p>0.05).

  • PDF

Manufacture of Cement-Bonded Particleboards from Korean Pine and Larch by Curing of Supercritical CO2 Fluid

  • Suh, Jin-Suk;Hermawan, Dede;Kawai, Shuichi
    • Journal of the Korean Wood Science and Technology
    • /
    • 제28권4호
    • /
    • pp.41-50
    • /
    • 2000
  • Cement-bonded particleboard is being used as outdoor siding material all over the world, because this composite particularly bears a light weight, high resistance against fire, decay, and crack by cyclic freezing and thawing, anti-shock property, and strength enhancement. Construction systems are currently changing into a frame-building style and wooden houses are being constructed with prefabrication type. Therefore, they require a more durability at outdoor-exposed sides. In this study, the cement hydration property for Korean pine particle, Japanese larch particle and face- and middle layer particles (designated as PB particle below) used in Korean particleboard-manufacturing company was investigated, and the rapid manufacturing characteristics of cement-bonded particleboard by supercritical $CO_2$ curing was evaluated. Korean pine flour showed a good hydration property, however, larch flour showed a bad one. PB particle had a better hydration property than larch flour. The addition of $Na_2SiO_3$ indicated a negative effect on hydration, however, $MgCl_2$ had a positive one. Curing by supercritical $CO_2$ fluid gave a conspicuous enhancement in the performances of cement-bonded particleboards compared to conventional curing. $MgCl_2$ 3%-added PB particle had the highest properties, and $MgCl_2$ 1%-added Korean pine particle had the second class with the conditions of cement/wood ratio of 2.7, a small fraction-screened particle and supercritical curing. On the contrary, the composition of non-hammermilled or large fraction-screened particle at cement/wood ratio of 2.2 was poorer. Also, the feasibility for actual use of 3%-added, small PB particle-screened fraction was greatest of all the conventional curing treatments. Relative superiority of supercritical curing vs. conventional curing at dimensional stability was not so apparent as in strength properties. Through the thermogravimetric analysis, it was ascertained that the peak of a component $CaCO_3$ was highest, and the two weak peaks of calcium silicate hydrate and ettringite and $Ca(OH)_2$ were present in supercritical treatment. Accordingly, it was inferred that the increased formation of carbonates in board contributes to strength enhancement.

  • PDF